1. Introduction
The Yieryi BLE-3188-P is a high-precision electrode probe designed for comprehensive water quality analysis. When connected to a compatible BLE-3188 main unit (sold separately or as part of a kit), it integrates advanced detection capabilities for various parameters with Bluetooth connectivity for wireless data transmission. This durable, waterproof probe is ideal for monitoring water quality in diverse applications such as aquariums, hydroponic systems, swimming pools, and industrial settings.
This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your BLE-3188-P electrode probe.
2. Product Overview
The BLE-3188-P electrode probe is a versatile component of the Yieryi water quality testing system. It features a robust, black cylindrical housing that is both waterproof and corrosion-resistant, ensuring longevity and reliability in various aquatic environments. The probe connects to the main unit via a waterproof aviation connector, providing a stable and secure signal transmission.

When paired with a compatible BLE-3188 main unit, this electrode can measure up to seven kinds of values, including pH, ORP, EC (Electrical Conductivity), PPM (Parts Per Million), CF (Conductivity Factor), Humidity, and Temperature. The main unit typically features a digital display with backlight and supports Bluetooth connectivity for seamless integration with a mobile application, allowing users to view current and historical data, set alarms, and manage measurements remotely.

3. Specifications
| Feature | Detail |
|---|---|
| Model | BLE-3188-P (Electrode Probe) |
| Brand | Yieryi |
| Detection Parameters | pH, ORP, EC, TDS, PPM, CF, Humidity, Temperature (requires compatible main unit) |
| Connectivity | BLE Bluetooth (for wireless data transmission via main unit) |
| Interface | Waterproof Aviation Connector |
| Probe Material | Black Cylindrical Housing (Waterproof & Corrosion-Resistant) |
| Cable Length | 112 cm |
| Probe Dimensions | 120mm (Length) x 30mm (Diameter) |
| Application | Aquarium, Hydroponics, Pool, Industrial Water Quality Testing |
| Certification | CE |
| Origin | Mainland China |
4. Package Contents
The BLE-3188-P electrode probe is available in two main configurations:
4.1. BLE-3188-P Electrode Probe (Base Model)

- 1 × BLE-3188-P Electrode Probe
4.2. BLE-3188-PD Electrode Probe + Liquid-Powder Set (Kit Model)

- 1 × BLE-3188-P Electrode Probe
- 3 × pH Buffer Powder (pH4.01/pH6.86/pH9.18)
- 1 × ORP Buffer Powder (256mV)
- 3 × pH Buffer Solution (pH4.01/pH6.86/pH9.18)
- 1 × EC Solution (1413uS/cm)
- 1 × TDS Solution (1382ppm)
- 1 × ORP Solution (256mV)

5. Setup
- **Unpack**: Carefully remove the BLE-3188-P electrode probe and any included accessories from its packaging.
- **Inspect**: Check the probe for any visible damage. Ensure the cable and aviation connector are intact.
- **Connect to Main Unit**: Align the waterproof aviation connector of the BLE-3188-P probe with the corresponding port on your BLE-3188 main unit. Gently push and twist the connector until it is securely fastened. Ensure a tight seal to prevent water ingress.
- **Initial Rinse**: Before first use, rinse the probe tip with distilled or deionized water to remove any storage solution or residue.
- **Power On**: Power on your BLE-3188 main unit according to its specific instructions.
Note: The BLE-3188-P is an electrode probe and requires a compatible BLE-3188 main unit for operation, display, and Bluetooth functionality. Refer to the main unit's manual for detailed instructions on its specific features and controls.
6. Operation
- **Preparation**: Ensure the probe is clean and properly connected to the BLE-3188 main unit.
- **Immersion**: Carefully immerse the tip of the BLE-3188-P electrode probe into the water sample you wish to test. Ensure the liquid level is above the sensing elements but below the connector to avoid damage.
- **Stabilization**: Allow a few moments for the readings on the main unit's display to stabilize. This typically takes a few seconds.
- **Reading Data**:
- **Directly from Main Unit**: Read the pH, ORP, EC, TDS, RH%, CF, and Temperature values directly from the digital display of the BLE-3188 main unit.
- **Via Mobile App**: If your main unit supports Bluetooth, download and connect to the official Yieryi mobile application (e.g., Tuya Smart app, as shown in Figure 2). The app allows you to view real-time data, historical trends, and set high/low data alarms.
- **Removal**: After measurement, remove the probe from the sample and rinse thoroughly with distilled or deionized water.

7. Calibration
Regular calibration is crucial for maintaining the accuracy of your BLE-3188-P electrode probe. The BLE-3188-PD kit includes various calibration solutions and powders for pH, ORP, EC, and TDS. Always refer to your BLE-3188 main unit's specific manual for detailed, step-by-step calibration procedures, as these can vary slightly depending on the main unit's firmware and interface.
General Calibration Guidelines:
- **pH Calibration**: Typically involves a 2-point or 3-point calibration using standard pH buffer solutions (e.g., pH 4.01, 6.86, 9.18).
- **ORP Calibration**: Usually performed with a standard ORP solution (e.g., 256mV).
- **EC/TDS Calibration**: Requires standard conductivity/TDS solutions (e.g., 1413uS/cm for EC, 1382ppm for TDS).
Always use fresh calibration solutions and follow the main unit's instructions precisely for optimal accuracy.
8. Maintenance
- **Cleaning the Probe**: After each use, rinse the electrode probe thoroughly with distilled or deionized water to prevent contamination and buildup of residues. For stubborn deposits, a soft brush or a mild cleaning solution recommended for pH/ORP electrodes may be used, followed by a thorough rinse.
- **Storage**:
- **pH/ORP Electrodes**: These electrodes should ideally be stored in a storage solution or a pH 4 buffer solution to keep the glass bulb hydrated. Never store a pH electrode dry.
- **EC/TDS Electrodes**: Can generally be stored dry after thorough rinsing.
- **Calibration Solutions**: Store calibration solutions in a cool, dark place. Discard expired or contaminated solutions.
- **Cable and Connector**: Keep the cable free from kinks and damage. Ensure the aviation connector is clean and dry before connecting or disconnecting.
9. Troubleshooting
If you encounter issues with your BLE-3188-P electrode probe, consider the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Inaccurate Readings |
|
|
| No Reading / Unstable Reading |
|
|
| Bluetooth Connectivity Issues (Main Unit) |
|
|
For further troubleshooting, consult the comprehensive user manual for your BLE-3188 main unit or contact Yieryi customer support.
10. User Tips
- **Regular Calibration**: To ensure the highest accuracy, especially for pH and ORP measurements, calibrate your probe regularly. The frequency depends on usage and desired precision, but weekly or bi-weekly calibration is often recommended for critical applications.
- **Proper Storage**: Always store pH/ORP electrodes in their designated storage solution or a pH 4 buffer. Allowing them to dry out can significantly shorten their lifespan and affect accuracy.
- **Cleanliness is Key**: A clean probe provides more accurate and stable readings. Always rinse the probe thoroughly with distilled water before and after each measurement.
- **Stable Readings**: Allow sufficient time for the readings to stabilize after immersing the probe in a new solution. Rushing the measurement can lead to inaccurate results.
- **Temperature Compensation**: Be aware of temperature effects on pH and conductivity readings. While the BLE-3188 system likely has automatic temperature compensation, understanding its impact can help interpret results.
11. Warranty and Support
For specific warranty information, please refer to the documentation provided with your purchase or contact the seller directly. Yieryi is committed to providing high-quality precision measurement tools.
A detailed user manual in PDF format is available for download. You can access it via the following link: Yieryi BLE-3188 User Manual (PDF).
For technical support or inquiries, please contact your retailer or visit the official Yieryi website.
12. Certifications
The Yieryi BLE-3188-P electrode probe, along with its compatible main units, complies with relevant international standards.
CE Certification
This product has received CE certification, indicating conformity with health, safety, and environmental protection standards for products sold within the European Economic Area (EEA).
Verification of Conformity:
- Standard: EU - Electromagnetic Compatibility (EMC)
- No.: CTB231221043EX-ZS
- Test Standards: EN IEC 61326-1:2021
- Applicant/Manufacturer: Jinan Huiquan Electronic Co., Ltd.
- Product: Water Quality Tester
- Date of Issue: Dec. 23, 2023
This certification confirms that the product meets the essential requirements of Directive 2014/30/EU relating to Electrical Equipment designed for use within Electromagnetic Compatibility.