1. Introduction
This manual describes the assembly, installation, operation, and troubleshooting of the Daxtromn 3.8KW 3800W Hybrid Solar Inverter. Please read this manual carefully before installation and operation. Keep this manual for future reference.
This is a multi-function inverter/charger, combining functions of an inverter, MPPT solar charger, and battery charger to offer uninterruptible power support with a portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
Features
- Pure sine wave inverter
- Programmable supply priority for PV, battery, or Grid
- High PV input voltage range (55~450VDC)
- Built-in Max 80A MPPT solar charge
- Compatible with lithium-ion battery
- Support BMS communication with Lithium battery
- Smart battery charge design to optimize battery life
- Overload, high temperature, inverter output short circuit protection
- Cold start function
- Intelligent fan speed adjustment
- WIFI (Optional, not included)
Basic System Architecture
The following illustration shows a basic application for this inverter/charger. It can power various appliances in home or office environments, including motor-type appliances such as tube lights, fans, refrigerators, and air conditioners.
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION – To reduce risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION – Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for the details.
- GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
- NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
3. Installation
3.1 Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items:
- The unit x 1
- User manual x 1
3.2 Preparation
Before connecting all wirings, please take off the bottom cover by removing two screws.
3.3 Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level in order to allow the LCD display to be read at all times.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces as shown in the right diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two screws into the wall.
3.4 Battery Connection
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. Please refer to the table below for typical amperage as required fuse or breaker size.
WARNING! All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable and terminal size as below.
| Model | Wire Size | Cable mm² | Ring Terminal D (mm) | Ring Terminal L (mm) | Torque Value |
|---|---|---|---|---|---|
| 3.8KW 24V / 6.2KW 48V | 1*2AWG | 22 | 6.4 | 33.2 | 2 Nm |
| 3.8KW 48V | 1*4AWG | 22 | 6.4 | 33.2 | 2 Nm |
Please follow below steps to implement battery connection:
- Assemble battery ring terminal based on recommended battery cable and terminal size.
- Connect all battery packs as units require.
- Insert the ring terminal of the battery cable flatly into the battery connector of the inverter and make sure the bolts are tightened with a torque of 2-3 Nm. Make sure polarity at both the battery and the inverter/charger is correctly connected and ring terminals are tightly screwed to the battery terminals.
WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.
CAUTION!! Do not place anything between the flat part of the inverter terminal and the ring terminal. Otherwise, overheating may occur.
CAUTION!! Do not apply anti-oxidant substance on the terminals before terminals are connected tightly.
CAUTION!! Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).
3.5 AC Input/Output Connection
CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between the inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is for 32A for 3.8KW, 50A for 6.2KW.
CAUTION!! There are two terminal blocks with "IN" and "OUT" markings. Please do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.
| Model | Gauge | Torque Value |
|---|---|---|
| 3.8KW | 12 AWG | 1.2~1.6 Nm |
| 6.2KW | 8 AWG | 1.4~1.6 Nm |
Please follow below steps to implement AC input/output connection:
- Before making AC input/output connection, be sure to open DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. And shorten phase L and neutral conductor N 3 mm.
- Insert AC input wires according to polarities indicated on the terminal block and tighten the terminal screws. Be sure to connect PE protective conductor (yellow-green) first.
- Then, insert AC output wires according to polarities indicated on the terminal block and tighten terminal screws. Be sure to connect PE protective conductor (yellow-green) first.
- Make sure the wires are securely connected.
WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
CAUTION: Important Be sure to connect AC wires with correct polarity. If L and N wires are connected reversely, it may cause utility short-circuited when these inverters are worked in parallel operation.
CAUTION: Appliances such as air conditioners are required at least 2~3 minutes to restart because it's required to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check the manufacturer of the air conditioner if it's equipped with a time-delay function before installation. Otherwise, this inverter/charger will trigger an overload fault and cut off output to protect your appliance, but sometimes it still causes internal damage to the air conditioner.
3.6 PV Connection
CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between the inverter and PV modules.
WARNING! All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.8KW/6.2KW | 1 x 12AWG | 4 | 1.2 Nm |
PV Module Selection
When selecting proper PV modules, please be sure to consider below parameters:
- Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
| INVERTER MODEL | 3.8KW | 6.2KW |
|---|---|---|
| Max. PV Array Open Circuit Voltage | 450Vdc | |
| PV Array MPPT Voltage Range | 55Vdc~450Vdc | |
Please follow below steps to implement PV module connection:
- Remove insulation sleeve 10 mm for positive and negative conductors.
- Check correct polarity of connection cable from PV modules and PV input connectors. Then, connect positive pole (+) of connection cable to positive pole (+) of PV input connector. Connect negative pole (-) of connection cable to negative pole (-) of PV input connector.
- Make sure the wires are securely connected.
3.7 Final Assembly
After connecting all wirings, please put the bottom cover back by screwing two screws.
4. Operation
4.1 Power ON/OFF
Once the unit has been properly installed and the batteries are connected well, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.
4.2 Operation and Display Panel
The operation and display panel, shown below, is on the front panel of the inverter. It includes three indicators, four function keys, and an LCD display, indicating the operating status and input/output power information.
LED Indicator Messages
| LED Indicator | Color | Status | Messages |
|---|---|---|---|
| AC/INV | Green | Solid On | Output is powered by utility in Line mode. |
| Flashing | Output is powered by battery or PV in battery mode. | ||
| CHG | Green | Solid On | Battery is fully charged. |
| Flashing | Battery is charging. | ||
| FAULT | Red | Solid On | Fault occurs in the inverter. |
| Flashing | Warning condition occurs in the inverter. |
Function Keys
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4.3 LCD Display Icons
The LCD display provides various icons to indicate the inverter's status, input/output information, and configuration settings. Refer to pages 13-14 of the PDF manual for a detailed explanation of each icon, including input source information, configuration program and fault information, output information, battery information, load information, and mode operation information.
4.4 LCD Setting
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use the "UP" or "DOWN" button to select setting programs, then press "ENTER" to confirm or "ESC" to exit. Detailed settings are available on pages 15-21 of the PDF manual, covering:
- Output source priority (PV, battery, or Grid)
- Maximum charging current (solar and utility chargers)
- AC input voltage range (Appliances or UPS)
- Power saving mode enable/disable
- Battery type (AGM, Flooded, User-Defined)
- Auto restart settings for overload and over temperature
- Output voltage and frequency
- Maximum utility charging current
- Setting voltage point back to utility source when selecting "SBU priority"
- Battery equalization settings (enable/disable, voltage, time, interval)
- Solar power balance adjustment
4.5 Display Setting
The LCD display information can be switched by pressing the "UP" or "DOWN" key. The selectable information includes input voltage, input frequency, PV voltage, MPPT charging current, MPPT charging power, battery voltage, output voltage, output frequency, load percentage, load in VA, load in Watt, DC discharging current, main CPU Version, and second CPU Version. Refer to pages 22-23 of the PDF manual for detailed display screens.
4.6 Operating Mode Description
The inverter operates in various modes depending on power availability and settings:
- Standby mode / Power saving mode: No output is supplied by the unit, but it can still charge batteries.
- Fault mode: Errors caused by internal circuit issues or external reasons (e.g., over temperature, output short circuit). PV energy and utility can charge batteries.
- Line Mode: The unit provides output power from the mains and charges the battery.
- Battery Mode: The unit provides output power from battery and PV power.
Detailed descriptions and LCD displays for each mode are available on pages 24-25 of the PDF manual.
4.7 Battery Equalization
Equalization function is added into the charge controller to reverse the buildup of negative chemical effects like stratification and to remove sulfate crystals, which can reduce battery capacity. It's recommended to equalize the battery periodically.
To apply equalization, enable the function in LCD setting program 33. Then, set the equalization interval in program 34 or activate it immediately in program 39. The controller will enter the Equalize stage when the set interval is reached or activated immediately. Refer to pages 26-27 of the PDF manual for detailed information on equalization charging time and timeout.
5. Troubleshooting
This section provides guidance for common issues. For persistent errors, contact a qualified service person or the service center.
| Problem | LCD/LED/Buzzer | Explanation / Possible cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD/LEDs and buzzer will be active for 3 seconds and then complete off. | The battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. The battery voltage is far too low. (<1.4V/Cell) 2. Battery polarity is connected reversed. | 1. Check if batteries and the wiring are connected well. 2. Re-charge battery. 3. Replace battery. |
| Input voltage is displayed as 0 on the LCD and green LED is flashing. | Input protector is tripped | Check if AC breaker is tripped and AC wiring is connected well. | |
| Mains exist but the unit works in battery mode. | Green LED is flashing. | Insufficient quality of AC power. (Shore or Generator) | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct. (UPS→Appliance) |
| Green LED is flashing. | Set "Solar First" as the priority of output source. | Change output source priority to Utility first. | |
| When the unit is turned on, internal relay is switched on and off repeatedly. | LCD display and LEDs are flashing | Battery is disconnected. | Check if battery wires are connected well. |
| Buzzer beeps continuously and red LED lights up. | Fault code 07 | Overload error. The inverter is overload 110% and time is up. | Reduce the connected load by switching off some equipment. |
| Fault code 05 | Output short circuited. | Check if wiring is connected well and remove abnormal load. | |
| Fault code 02 | Temperature of internal converter component is over 120°C. / Internal temperature of inverter component is over 100°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. | |
| Fault code 03 | Battery is over-charged. / The battery voltage is too high. | Return to repair center. / Check if spec and quantity of batteries meet requirements. | |
| Fault code 01 | Fan fault | Replace the fan. | |
| Fault code 06/58 | Output abnormal (Inverter voltage below than 190Vac or is higher than 260Vac) | 1. Reduce the connected load. 2. Return to repair center. | |
| Fault code 08/09/53/57 | Internal components failed. | Return to repair center. | |
| Fault code 51 | Over current or surge. | Restart the unit, if the error happens again, please return to repair center. | |
| Fault code 52 | Bus voltage is too low. | If the battery is connected well, please return to repair center. | |
| Fault code 55 | Output voltage is unbalanced. | ||
| Fault code 56 | Battery is not connected well or fuse is burnt. |
For a complete list of Fault Reference Codes and Warning Indicators, please refer to pages 28-29 of the PDF manual.
6. Specifications
6.1 Line Mode Specifications (Table 1)
| INVERTER MODEL | 3.8KW 24V | 3.8KW 48V | 6.2KW 48V |
|---|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | ||
| Nominal Input Voltage | 230Vac | ||
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) | ||
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) | ||
| High Loss Voltage | 280Vac±7V | ||
| High Loss Return Voltage | 270Vac±7V | ||
| Max AC Input Voltage | 300Vac | ||
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | ||
| Low Loss Frequency | 40±1Hz | ||
| Low Loss Return Frequency | 42±1Hz | ||
| High Loss Frequency | 65±1Hz | ||
| High Loss Return Frequency | 63±1Hz | ||
| Output Short Circuit Protection | Line mode: Circuit Breaker; Battery mode: Electronic Circuits | ||
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | ||
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | ||
| Output power derating: When AC input voltage drops to 95V or 170V depending on models, the output power will be derated. | ![]() | ||
6.2 Inverter Mode Specifications (Table 2)
| INVERTER MODEL | 3.8KW 24V | 3.8KW 48V | 6.2KW 48V |
|---|---|---|---|
| Rated Output Power | 4.2KVA/3.8KW | 7.0KVA/6.2KW | |
| Output Voltage Waveform | Pure Sine Wave | ||
| Output Voltage Regulation | 230Vac±5% | ||
| Output Frequency | 60Hz or 50Hz | ||
| Peak Efficiency | 94% | ||
| Overload Protection | 5s@≥150% load; 10s@110%~150% load | ||
| Surge Capacity | 2* rated power for 5 seconds | ||
| Nominal DC Input Voltage | 24Vdc | 48Vdc | |
| Cold Start Voltage | 23.0Vdc | 46.0Vdc | |
| Low DC Warning Voltage @load < 20% | 22.0Vdc | 44.0Vdc | |
| Low DC Warning Voltage @20% ≤ load < 50% | 21.4Vdc | 42.8Vdc | |
| Low DC Warning Voltage @load ≥ 50% | 20.2Vdc | 40.4Vdc | |
| Low DC Warning Return Voltage @load < 20% | 23.0Vdc | 46.0Vdc | |
| Low DC Warning Return Voltage @20% ≤ load < 50% | 22.4Vdc | 44.8Vdc | |
| Low DC Warning Return Voltage @load ≥ 50% | 21.2Vdc | 42.4Vdc | |
| Low DC Cut-off Voltage @load < 20% | 21.0Vdc | 42.0Vdc | |
| Low DC Cut-off Voltage @20% ≤ load < 50% | 20.4Vdc | 40.8Vdc | |
| Low DC Cut-off Voltage @load ≥ 50% | 19.2Vdc | 38.4Vdc | |
| High DC Recovery Voltage | 29Vdc | 58Vdc | |
| High DC Cut-off Voltage | 31Vdc | 62Vdc | |
| No Load Power Consumption | <25W | <50W | |
| Saving Mode Power Consumption | <10W | <15W | |
6.3 Charge Mode Specifications (Table 3)
| INVERTER MODEL | 3.8KW 24V | 3.8KW 48V | 6.2KW 48V |
|---|---|---|---|
| Utility Charging Mode | |||
| Charging Current (UPS) @Nominal Input Voltage | 80A | 60A | 80A |
| Bulk Charging Voltage Flooded Battery | 29.2 | 58.4 | |
| Bulk Charging Voltage AGM / Gel Battery | 28.2 | 56.4 | |
| Floating Charging Voltage | 27Vdc | 54Vdc | |
| Charging Algorithm | 3-Step | ||
| Solar Charging Mode | |||
| Rated Power | 6000W | ||
| PV Charge Current | 110A | 80A | 110A |
| Efficiency | 98.0% max. | ||
| Max. PV Array Open Circuit Voltage | 450Vdc | ||
| PV Array MPPT Voltage Range | 55-450Vdc | ||
| Min battery voltage for PV charge | 2W | ||
| Standby Power Consumption | +/-0.3% | ||
| Battery Voltage Accuracy | +/-2V | ||
| PV Voltage Accuracy | 3-Step | ||
| Charging Algorithm | |||
6.4 General Specifications (Table 4)
| INVERTER MODEL | 3.8KW 24V | 3.8KW 48V | 6.2KW 48V |
|---|---|---|---|
| Safety Certification | CE | ||
| Operating Temperature Range | 0°C to 55°C | ||
| Storage Temperature | -15°C~60°C | ||
| Dimension (D*W*H), mm | 423*290*100(mm) | 423*290*105(mm) | |
| Net Weight, kg | 6.8KG | 6.9KG | 7.5KG |
7. User Tips
- This inverter requires batteries to operate; it cannot function without them.
- This is an off-grid inverter and does not support parallel connection or grid connection.
- For optimal performance, ensure proper ventilation around the unit as indicated in the mounting instructions.
- Always use the recommended cable sizes for battery, AC, and PV connections to ensure safety and efficiency.
8. Warranty and Support
The Daxtromn 3.8KW 3800W Hybrid Solar Inverter comes with a 1-year warranty.
For detailed guides and further information, you can refer to the official user manual PDF: User Manual (PDF).
If you encounter any issues not covered in the troubleshooting section or require service, please contact your local dealer or the service center for maintenance.