1. Introduction
The KUAIQU SPPS-K305 is a professional DC power supply designed for precision applications requiring low ripple and micro-current measurement capabilities. Featuring a hyperbolic display and embedded development support, this adjustable power supply is ideal for electronic R&D, industrial testing, automotive applications, and laboratory use. It offers high accuracy with a 5-digit display, multiple protection features, and convenient storage for frequently used settings.
2. Product Features
The SPPS-K305 power supply incorporates a range of advanced features for precise and safe operation:
- Five-digit Display: High-precision display with 0.001V voltage resolution and 0.01mA current resolution.
- Hyperbolic Display (Curve Graph): Real-time output voltage and current curves for detailed analysis.
- Four Groups of Storage (M1-M4): Quickly recall preset voltage and current values.
- Automatic mA Conversion: Automatically switches to 0.01mA display for currents below 0.1A.
- Load Short Circuit Alarm: Stops output and sounds an alarm upon detecting a short circuit.
- Output Switch: Allows direct setting of voltage and current before activating output.
- Panel Lock: Locks all keys and knobs to prevent accidental changes during operation.
- OCP (Over Current Protection): Limits current and powers off if exceeded, with alarm.
- OVP (Over Voltage Protection): Limits voltage and powers off if exceeded, with alarm.
- Temperature Control Protection: Activates a cooling fan when the internal temperature reaches 50°C.
- Automatic Constant Pressure and Constant Current (CC/CV): Automatically switches modes based on load changes.
- Dual Quick Charging Ports: Includes USB-A (5V/2A) and USB-C (5V/2A) for charging external devices.
3. Setup
3.1 Unpacking and Contents
Before use, carefully unpack the power supply and verify all components are present:
- 1x KUAIQU DC Power Supply
- 1x Power Cord
- 2x Output Load Lines
- 1x User Manual (PDF available online, see section 8)
3.2 Power Connection
- Ensure the power supply is placed on a stable, well-ventilated surface.
- Connect the provided power cord to the power input on the rear of the unit and then to a suitable AC power outlet (110V ±10% 60Hz or 220V ±10% 50Hz, depending on your model).
- Connect the output load lines to the positive (+) and negative (-) output ports on the front panel, and the ground wire to the GND port, as required by your application.
4. Operating Instructions
4.1 Power On/Off
Press the POWER switch on the front panel to turn the unit on or off.
4.2 Setting Voltage and Current
- Rotate the VOLTAGE encoder knob to adjust the output voltage.
- Rotate the CURRENT encoder knob to adjust the output current.
- Press the respective knob to toggle the digit position for fine adjustment.
4.3 Activating Output
After setting the desired voltage and current, press the OUTPUT button to activate the power supply output. The button will light up when the output is active. Press it again to turn off the output.
4.4 Hyperbolic Display (Curve Graph Function)
Press the CURVE button to enter the curve graph screen. Connect your load and turn on the output switch to observe real-time output voltage (blue curve) and current (orange curve) graphs. This feature is useful for monitoring power consumption and transient behavior of electronic products.
4.5 Memory Function (M1-M4)
The power supply allows storing four groups of voltage and current settings (M1-M4) for quick recall. Temporarily set values are stored in M0.
- Press the Memory button to enter the list interface.
- Rotate the VOLTAGE knob to select the desired setting group (M1-M4).
- Press the VOLTAGE knob to enter the setting mode for the selected group.
- Adjust the voltage and current using their respective knobs.
- Lightly press the VOLTAGE knob to save the settings to the selected memory group.
4.6 Panel Lock Function
Press the LOCK button to activate the panel lock. This will prevent any accidental changes to the settings by disabling the knobs and buttons. The lock indicator will light up. Press the LOCK button again to unlock the panel.
4.7 Adjusting Key Tone
Press and hold the LOCK button for approximately 5 seconds to turn the buzzer key tone on or off. This is useful for quiet environments.
4.8 Dual Fast Charging Ports
The front panel includes USB-A (5V/2A) and USB-C (5V/2A) ports for charging mobile phones and other electronic devices. Note that when both ports are used simultaneously, they operate in normal charging mode; for fast charging, use one port at a time.
5. Protection Features
5.1 OCP (Over Current Protection)
To enable OCP, long press the OCP button to enter the setting interface. Adjust the current limit value and press the knob to confirm. When enabled, if the output current exceeds the set limit, the power supply will alarm and cut off the output to protect the load. Press OCP again to clear the alarm and terminate OCP, or press OUTPUT to clear the alarm while keeping OCP active.
5.2 OVP (Over Voltage Protection)
To enable OVP, long press the OVP button to enter the setting interface. Adjust the voltage limit value and press the knob to confirm. When enabled, if the output voltage exceeds the set limit, the power supply will alarm and cut off the output. Press OVP again to clear the alarm and terminate OVP, or press OUTPUT to clear the alarm while keeping OVP active.
5.3 Load Short Circuit Alarm
The device detects short circuits in the load. Upon detection, it stops output and triggers a buzzer alarm, protecting the external load. This is distinct from OCP/OVP which are user-settable limits.
5.4 Temperature Control Protection
An intelligent cooling fan automatically activates when the power supply's internal temperature reaches 50°C, ensuring stable operation and preventing overheating.
6. Specifications
The following table details the technical specifications of the KUAIQU SPPS-K series DC Power Supplies:
| Parameter | SPPS-K305 | SPPS-K3010 | SPPS-K605 | SPPS-K1203 |
|---|---|---|---|---|
| Rated Value (0°C~40°C) | 0-30V, 0-5A, 150W | 0-30V, 0-10A, 300W | 0-60V, 0-5A, 300W | 0-120V, 0-3A, 360W |
| USB/Type-C Output | 5V/2A | |||
| Load Regulation (Voltage) | ≤0.01%+10 mV | ≤0.01%+15 mV | ||
| Load Regulation (Current) | ≤0.1%+5 mA | ≤0.1%+10 mA | ||
| Line Regulation (Voltage) | ≤0.01%+2.5 mV | |||
| Line Regulation (Current) | ≤0.1%+2.5 mA | ≤0.1%+3 mA | ||
| Setting Resolution (Voltage) | 1mV | |||
| Setting Resolution (Current) | 1mA | |||
| Readback Resolution (Voltage) | 1mV | |||
| Readback Resolution (Current) | <20mA: 10 uA, ≥20mA: 1mA | |||
| Setting Accuracy (Voltage) | 0.05%+10 mV | 0.05%+15 mV | ||
| Setting Accuracy (Current) | 0.1%+10 mA | |||
| Readback Accuracy (Voltage) | 0.05%+10 mV | 0.05%+15 mV | ||
| Readback Accuracy (Current) | <20mA: 0.1%+60uA, 20mA~10A: 0.1%+10mA | <20mA: 0.1%+60uA, 20mA~10A: 0.1%+10mA | <20mA: 0.1%+100uA, 20mA~10A: 0.1%+10mA | <20mA: 0.1%+100uA, 20mA~10A: 0.1%+10mA |
| Ripple (20Hz~20MHz) Voltage | ≤100 mVp-p, 15 mVrms | ≤120 mVp-p, ≤20 mVrms | ||
| Ripple (20Hz~20MHz) Current | ≤15 mArms | ≤10mArms | ||
| Rise Time (No Load) | ≤200mS | |||
| Rise Time (Full Load) | ≤300mS | |||
| Fall Time (No Load) | ≤3S | |||
| Fall Time (Full Load) | ≤200mS | |||
| Input Voltage/Current | AC 220V (AC110V optional) | |||
| Size (L*W*H) | Approx. 19.5*9*14.5cm | |||
| Net Weight | Approx. 1.17KG | |||
| Package Size/Weight | Single unit: 29.5*13*21cm, 1.58KG (8pcs/Carton) | |||
Operating temperature: 0 ℃-40℃; Relative humidity: <80%RH
Storage temperature: -10℃-70℃; Relative humidity: <70%RH
7. Maintenance
- Keep the power supply clean and free from dust. Use a soft, dry cloth for cleaning.
- Ensure proper ventilation around the unit to prevent overheating. Do not block the ventilation openings.
- Avoid exposing the device to moisture or extreme temperatures.
- If the device requires service, contact customer support. Do not attempt to repair it yourself.
8. Troubleshooting
- No Output: Check if the OUTPUT button is pressed and illuminated. Ensure the power cord is securely connected and the unit is powered on.
- Short Circuit Alarm: If the short circuit alarm sounds, immediately disconnect the load. Check the load for any faults or short circuits. The power supply will stop output to protect the load.
- OVP/OCP Alarm: If an OVP or OCP alarm is triggered, the output will be cut off. Check your voltage and current settings against the load requirements. Adjust the OVP/OCP limits if necessary, or resolve the external condition causing the over-limit.
- Unresponsive Controls: If the knobs or buttons are not responding, check if the LOCK function is active (lock indicator illuminated). Press the LOCK button to disable it.
- Fan Running Constantly: This is normal if the internal temperature exceeds 50°C. Ensure adequate ventilation around the unit.
9. User Tips
- Utilize the four memory groups (M1-M4) to save frequently used voltage and current settings for quick access in different projects.
- The hyperbolic display (CURVE function) is excellent for observing transient responses and power consumption patterns of circuits, especially during startup of electronic devices.
- Always set your OCP and OVP limits slightly above your expected operating values to provide a safety margin without unnecessary tripping.
- For precise micro-current measurements, take advantage of the automatic mA conversion feature, which provides higher resolution below 0.1A.
10. Warranty and Support
10.1 Warranty Information
Our store provides free replacement of orders within 30 days from the delivery date. For orders from 1 to 12 months, a partial payment of the order value may be required for replacement. For orders over 12 months, a small discount may be offered.
10.2 Customer Support
For any questions or support needs, please contact customer service. Our working hours are from 9:00 am to 6:30 pm, Monday to Friday, Beijing time. We aim to respond to inquiries within 10 minutes during working hours and resolve problems within 24 hours.
For a detailed user manual in PDF format, please refer to the following links:
- English: User Manual (English)
- German: User Manual (German)
- French: User Manual (French)
- Spanish: User Manual (Spanish)
- Italian: User Manual (Italian)