1. Introduction
The MYAMi ES Series Hybrid Solar Inverter is a versatile, integrated inverter-controller machine designed to provide uninterrupted power support for photovoltaic solar power generation systems. It converts direct current into alternating current and features a compact, portable design.
These hybrid inverters offer unique advantages by reducing the need for separate solar controllers, minimizing external installation space, and simplifying wiring. The dual LCD display intuitively shows operational data for both the solar controller and inverter.
Available in 3KW, 5KW, and 6KW power options (MY-ES3000B, MY-ES5000B, MY-ES6000B), all models include a built-in 60A MPPT solar controller for efficient tracking and conversion. They support a wide range of battery types, including lead-acid, gel, AGM, and lithium iron phosphate, with voltage compatibility up to 96V. Users can also customize battery settings and charging currents to suit various applications.
Hybrid inverters are increasingly preferred for off-grid power generation systems, enabling autonomous electricity generation and consumption, free from grid constraints.
2. Safety Instructions
Please read and adhere to the following safety guidelines to ensure safe operation and prevent injury or damage:
- Before using the device, read all instructions and warning labels on the device, batteries, and this manual.
- To reduce the risk of injury, only charge deep cycle lead-acid rechargeable batteries. Other battery types may burst, causing personal injury and damage.
- Do not attempt to disassemble the equipment. For service or repair, send it to a qualified service center. Incorrect reassembly may lead to electric shock or fire.
- To reduce the risk of electric shock, disconnect all wiring before performing any maintenance or cleaning. Turning off the equipment alone does not eliminate this risk.
- Only qualified personnel should install equipment with batteries.
- Never charge a frozen battery.
- Select the appropriate cable size according to regulations to optimize the inverter/charger's performance.
- Exercise extreme caution when using metal tools on or near the battery. Dropping a tool may cause sparks or short circuits, potentially leading to an explosion.
- Strictly follow the installation procedures detailed in the 'Installation' section of this manual.
- Provide a 150A fuse for the battery power supply for overcurrent protection.
- This inverter/charger must be connected to a permanently grounded cabling system. Ensure compliance with local requirements and regulations during installation.
- Do not short circuit the AC output and DC input. Do not connect the power supply if the DC input is short-circuited.
- Only qualified maintenance personnel should repair the equipment. If troubleshooting does not resolve an issue, return the inverter/charger to the local dealer or service center for repair.
3. Setup and Installation
3.1 Installation Environment
Before selecting the installation location, consider the following points:
- Do not install the inverter on flammable building materials.
- Mount the inverter on a solid surface.
- Install the inverter at eye level to easily read the LCD display.
- To ensure proper air circulation for heat dissipation, leave a gap of approximately 20 cm behind the unit and 50 cm on each side.
- The ambient temperature should be between 0°C and 55°C for optimal operation.
- It is recommended to install the unit vertically on a wall.
- Ensure sufficient clearance from other objects and surfaces for heat dissipation and easy wiring access.
3.2 Connection Method
The correct wiring sequence for the solar energy controller is crucial:
- First, connect the positive (+) and negative (-) electrodes of the battery.
- Next, connect the positive (+) and negative (-) poles of the DC load.
- Finally, connect the positive (+) and negative (-) electrodes of the solar panel.
Important: The input voltage of the battery and the inverter must be consistent. The maximum voltage input of the solar panel is 230V.

Figure 3.1: System Connection Diagram

Figure 3.2: Inverter Rear Panel Connections
The upgraded design of the rear panel connections (as shown in Figure 3.3) makes installation and operation more convenient.

Figure 3.3: Rear Panel Upgrade for Easier Installation
4. Operation
4.1 LCD Display and Indicators
The inverter features a dual LCD display and various indicators to provide real-time operational status:

Figure 4.1: Dual LCD Display Overview
- PV Panel Indicator Light: Indicates status of photovoltaic input.
- Charging Indicator Light: Shows battery charging status.
- DC Load Indicator Light: Indicates status of DC loads.
- Warning Indicator Light: Alerts to system warnings or faults.
- Input Voltage Display: Shows the current input voltage (e.g., DC 58.9V).
- Output Power Display: Shows the current output power (e.g., 0W AC).
- Output Voltage Display: Shows the current output voltage (e.g., 228V 50Hz).
- Battery Display: Visual representation of battery charge level.
- Power Display: Numerical display of power.
- Auto-switching Display: Automatically switches between frequency and temperature.
- Solar Input Voltage: Displays the voltage from solar panels (e.g., 166.13V).
- Controller Power Generation Wattage: Shows total power generated by the controller (e.g., 226.7W).
- Controller Charging Current: Displays the current charging the battery (e.g., 4.6A).
- Battery Voltage: Shows the current battery voltage (e.g., 49.39V).
- Daily Electricity Generation: Records daily power output (e.g., 0.722kWh).
- Total Electricity Generation: Records cumulative power output (e.g., 209.486kWh).
4.2 Push-Button Operating Instructions
The inverter features several buttons for navigation and settings:
- Set up/Back Button: Used to enter setup menus or go back.
- Flip Up Button: Used to navigate up or increase values.
- Flip Down Button: Used to navigate down or decrease values.
- OK Button: Used to confirm selections or enter submenus.
4.3 Parameter Setting Operation Procedure
To access and modify settings:
- From the default main interface, press the SET button to enter the main menu.
- Use the DOWN or UP buttons to navigate through the submenus.
- Press the OK button to select a menu item and enter its settings.
Available settings include:
- Battery Type Setting: Choose from 4 built-in battery types (Lead Acid, Gel, LifePo4, Li-ion) or set a custom user type. After selecting, click Enter to set the required voltage.
- Charging Current Setting: Adjust the charging current. The available range varies by product model.
- DC Output Setting: Toggle the DC load ON or OFF.
- Language Setting: Select between Chinese (中文) and English.
- Reset Total: Clear all recorded data.
- Restore Factory Settings: Reset all settings to their default values.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your MYAMi Hybrid Solar Inverter.
- Power Disconnection: Always disconnect all power sources (solar panels, battery, AC input) before performing any maintenance or cleaning to prevent electric shock.
- Cleaning: Keep the inverter's exterior clean and free from dust and debris. Ensure that the cooling vents are unobstructed to allow for proper airflow. The inverter features smart fan cooling to manage internal temperatures.
- Inspections: Periodically check all wiring connections for tightness and signs of corrosion. Ensure that the fuse for the battery power supply is intact.
- Professional Service: Any internal repairs or complex maintenance should only be performed by qualified service personnel. Do not attempt to open the inverter casing yourself, as this may void the warranty and pose safety risks.
6. Troubleshooting
The inverter's LCD display provides error codes to help identify and resolve issues:
| Error Code | Designation |
|---|---|
| E01 | Short circuit function fault |
| E02 | Power supply input undervoltage fault prompt |
| E03 | High temperature protection tips |
| E04 | Overload protection tips |
| E05 | Overvoltage protection prompt |
| E06 | Front-stage power overload prompt |
If you encounter any of these error codes, refer to the specific troubleshooting steps in the detailed user manual. If the issue persists after attempting troubleshooting, please contact a qualified service center or your local dealer for assistance.
7. Specifications
The MYAMi Hybrid Solar Inverter is available in several models with varying power outputs and input voltages:
| Attribute | MY-ES3000B | MY-ES5000B |
|---|---|---|
| Power | 3000W | 5000W |
| Controller Current | 60A | 60A |
| Input Voltage | 12V/24V/48V/60V/72V/96V | 24V/48V/60V/72V/96V |
| Size (L*W*H) | 39.3*33*10.5cm | 39.3*39*10.5cm |
| Weight | 7.3kg | 9.18kg |
For the MY-ES6000B model:
| Attribute | MY-ES6000B |
|---|---|
| Rated Power | 6000W |
| MPPT Charging Current | 60A |
| Battery Input Voltage | DC 24V/48V/60V/72V |
| Size (L*W*H) | 39.3*39*10.5cm |
| Weight | 9.18kg |
General Specifications:
- Brand Name: MYAMi
- Output Type: SINGLE
- EU LVD Voltage: High voltage: Above 50Vac or 75Vdc
- Origin: Mainland China
- Is Smart Device: Yes
- Product Name: Hybrid Solar Inverter
- Application: Home appliances/solar energy systems/residential use
- Inverter type: MPPT Hybrid Power Inverter
- Battery type: Lead-acid/GEL/AGM/Lithium iron phosphate
- MPPT Efficiency: 97%-99%
- Protection: Short circuit, overload, overvoltage, overtemperature
- Display screen: Dual LCD Displays
- Cooling: Smart fan cooling
8. User Tips
8.1 Determining Battery Needs for a 3000W Inverter
To size batteries for a 3000W inverter, estimate your daily electricity consumption and follow these steps:
- Calculate Daily Power Consumption: Sum the power consumption of all electrical devices. Multiply each device's rated power by its daily usage hours. For example, a 3000W appliance used for 1 hour equals 3000Wh per day.
- Determine Backup Days: Multiply the daily power consumption by the number of backup days required.
- Account for Depth of Discharge (DOD): Divide the result from step 2 by the maximum DOD (e.g., if DOD is 50%, divide by 0.5).
- Consider Temperature Efficiency: Batteries are less efficient at lower temperatures. Factor this into your calculation.
- Match System Voltage: Connect batteries to achieve the desired system voltage (12V, 24V, or 48V). Divide the result from step 4 by the required battery voltage.
- Calculate Number of Batteries: If you need a 1050Ah battery pack with 12V105Ah batteries, you would need 10 batteries (1050Ah / 105Ah = 10 pieces).
For complex calculations or personalized assistance, contact MYAMi directly for customized battery capacity and quantity recommendations. Our Solar Inverters support 12V, 24V, 48V, 60V, 72V, and 96V battery systems.
8.2 What a 3000 Watt Solar Inverter Can Run
A 3000-watt inverter can power many devices, provided their total power demand does not exceed 3000 watts. Always check the rated power of your appliances, usually found on their labels.
Typically, large inverters can handle a 15-20% overload for short periods. Following this guideline, a 3000W inverter is suitable for operating loads of approximately 2400-2500 watts continuously.
A 3000-watt inverter can comfortably power common household items such as lighting loads, refrigerators, microwaves, and coffee machines. It can also charge mobile phones and laptops. Always verify specific equipment power ratings as they can vary.
9. Warranty and Support
9.1 Quality Assurance and Warranty
Each MYAMi Hybrid Solar Inverter undergoes strict quality checks before leaving the factory to ensure high quality, good performance, and complete parts.
The product comes with a one-year free warranty from the date of purchase. During this period, if any damage or failure occurs, the machine will be repaired free of charge, and necessary parts will be replaced. Damaged parts must be returned to the company.
9.2 Warranty Exclusions
The warranty will automatically expire under the following circumstances:
- Changes to the company trademark.
- Damage caused by faulty operation, negligent use, or force majeure events.
- Repairs, modifications, alterations, removal of machine numbers, or seals performed by technical personnel not authorized by the company.
- Failure to install the product according to the installation instructions provided by the original factory.
Please retain your purchase receipt (invoice) and this manual as proof of purchase for warranty claims.
9.3 Additional Resources
A detailed user manual with further instructions and diagrams is available in PDF format. You can access it here.
10. Frequently Asked Questions (FAQ)
- Q1: Who is MYAMi?
- A: MYAMi is a solution supplier for power supply, inverter, controller, and communication systems. We are dedicated to the research, development, design, production, and sales of power supply and communication products. We cooperate with relevant technical colleges for the transformation between research and industrialization.
- Q2: Can MYAMi produce customized products?
- A: Yes. We offer OEM & ODM services. We can produce items according to your specific design and ideas.
- Q3: What products does MYAMi offer?
- A: We offer DC Power Supplies, Variable DC Power Supplies, Switching Power Supplies, Programmable Power Supplies, AC Power Supplies, Cabinet Type Power Supplies, Solar Power Pure Sine Wave Inverters, Car Inverters, Solar Hybrid Inverters, and Solar Charge Controllers.
- Q4: Why should I choose MYAMi?
- A: We have a professional R&D team and extensive production experience, enabling us to effectively solve your problems and provide professional pre-sales and after-sales service. Our collaborations with universities ensure continuous innovation and industrialization of research.
- Q5: What is your delivery time?
- A: Delivery time depends on the quantity of your order. Regular products are typically in stock and can be arranged for shipment within 24 hours.