1. Important Safety Instructions
Please save these instructions for future use. Read all instructions and cautions in this manual before beginning installation.
- Installation and wiring must comply with Local and National Electric Codes (NEC) and be performed by a certified technician.
- Do NOT disassemble or attempt to repair the inverter. There are no serviceable parts.
- Do NOT parallel this device with other AC input sources to avoid damage.
- Do NOT touch the unit while operating as temperatures will be very hot. Do not open the terminal cover while the unit is in operation.
- Ensure all connections to and from the inverter are tight. Avoid flammable materials or gases near installation due to potential sparks.
- Installing breakers or fuses outside the unit is recommended.
- After installation, check that all line connections are tight and secured.
- Do NOT let the positive (+) and negative (-) terminals of the battery touch each other. Use Lithium, deep cycle Sealed Lead Acid, Flooded, Gel, or AGM batteries.
- Explosive battery gases may be present while charging. Ensure adequate ventilation.
- Wear eye protection and have fresh water available when working with large lead acid batteries.
- Review specific battery requirements to avoid damage from over-charging or excessive gas precipitation.
2. Product Overview
The PowMr POW-SunSmart series is an all-in-one solar charge inverter designed for solar energy storage, utility charging, and AC sine wave output. It features DSP control for high response speed, reliability, and industrial standards.
2.1 Key Features
- Supports lead-acid and Li-ion battery connections.
- Dual activation function for dormant Li-ion batteries (mains/photovoltaic power supply).
- Supports split-phase and single-phase pure sine wave output.
- Supports multiple output voltage levels: 100Vac, 105Vac, 110Vac, 115Vac, 120Vac, and 127Vac per phase.
- Two solar inputs with simultaneous tracking of two maximum power points (Dual MPPT) for charging/carrying functions.
- Dual MPPT with 99.9% efficiency and maximum 22A current per circuit, optimized for high power modules.
- Available charging modes: solar only, and mixed mains/PV charging.
- Time-slot charging and discharging settings for optimized energy use.
- Energy saving mode to reduce no-load energy losses.
- Two output modes: utility bypass and inverter output, with uninterrupted power supply.
- Large LCD screen with dynamic flow diagram for system data and operation status.
- 360° protection: short circuit, over current, over/under voltage, overload, backfill protection.
- Supports CAN, USB, and RS485 communication.
2.2 Product Components
The inverter features a touch screen, dual MPPT, 500Vdc Max PV Array Voltage, MPPT 200A Solar Charge, and DC 48V Battery Voltage.

Image Description: A detailed diagram of the PowMr Hybrid Inverter, showing its front, side, and bottom views with dimensions (133.0 mm width, 620.0 mm height, 445.0 mm depth) and numbered components. Key components include: 1. LCD Screen, 2. LED Indicators, 3. Touchable key, 4. ON/OFF Rocker Switch, 5. PV INPUT (1/1), 6. BAT INPUT (+), 7. BAT INPUT (-), 8. Dry contact, 9. CAN/RS485 port, 10. WIFI Port, 11. USB-B port, 12. Grounding Screw, 13. AC OUT (L1+L2+N), 14. AC IN (L1+L2+N), 15. AC INPUT breaker, 16. Parallel Communication Port.
The product package includes the solar inverter, an instruction manual, and cable lugs and screws.

Image Description: An image illustrating the contents of the product box, which includes the main solar inverter unit, a printed instruction manual, and a set of cable lugs and screws for installation.
3. Setup and Installation
3.1 Mounting the Inverter
The POW-SunSmart series is designed for INDOOR USE ONLY (IP20).
- Choose a solid wall for installation.
- Mount the inverter at eye level.
- Ensure adequate heat dissipation space around the inverter.
- The ambient temperature should be between -10~55°C (14~131°F) for optimal operation.
DANGER:
- Do not install the inverter near highly flammable materials or in potential explosive areas.
- Do not install the inverter with lead-acid batteries in a confined space.
CAUTION:
- Do not install the inverter in direct sunlight or a humid environment.
Make 4 mounting holes in the wall according to the specified dimensions (500mm width, 618mm height, 230mm depth). Insert 2 expansion screws above and fix the inverter with 2 M5 screws below.
3.2 Removing the Terminal Cover and Insect Screen
Use a screwdriver to remove the terminal protection cover and insect screen.
NOTICE:
When using the device in areas with poor air quality, regularly dismantle and clean the dust screen to prevent blockage, which can affect internal airflow and trigger over-temperature protection faults (19/20 fault).
3.3 Connection Overview
The system consists of PV modules, utility grid/generator, battery, home loads, and the inverter. The actual wiring method depends on the application scenario.

Image Description: A diagram illustrating the overall system connection. It shows PV panels connected to the inverter, which is then connected to external battery packs, a utility grid or generator, and various home appliances (loads). The diagram highlights the flow of energy between these components.
Split-phase Mode (Default)
Output Voltage Range (L-N): 100~120Vac (120Vac default)
Output Voltage Range (L-L): 200~240Vac (240Vac default)

Image Description: A wiring diagram for the inverter in split-phase mode. It shows the connection of PV panels to the inverter (Split-Phase L1+L2+N+PE), the inverter's output to a home load, and a battery pack (48V) connected to the inverter. A notice warns that the open circuit voltage of the PV panel in series connection must be below 500V to prevent damage and voiding warranty.
Single-phase Mode
Output Voltage Range (L-N): 100~120Vac (120Vac default)

Image Description: A wiring diagram for the inverter in single-phase mode. It shows the connection of PV panels to the inverter (Single-Phase L1+N+PE), the inverter's output to a home load, and a battery pack (48V) connected to the inverter. A notice warns that the open circuit voltage of the PV panel in series connection must be below 500V to prevent damage and voiding warranty.
3.4 Cable & Circuit Breaker Requirements
Ensure correct cable diameters and circuit breaker specifications for PV input, AC input, and battery connections.
| Model | Cable Diameter | Max. PV Input Current | Circuit Breaker Spec |
|---|---|---|---|
| 8KW Model | 5mm² / 10 AWG | 22A | 2P-25A |
| 10KW Model | 5mm² / 10 AWG | 22A | 2P-25A |
| Model | Output Mode | Max. Input Current | Cable Diameter | Circuit Breaker Spec |
|---|---|---|---|---|
| 8KW Model | Split-phase | 63A (L1/L2/N) | 13mm² / 6AWG (L1/L2/N) | 3P-63A |
| Single-phase | 63A (L1/L2), 126A (N) | 13mm² / 6AWG (L1/L2), 26mm² / 3AWG (N) | 2P-125A | |
| 10KW Model | Split-phase | 63A (L1/L2/N) | 13mm² / 6AWG (L1/L2/N) | 3P-63A |
| Single-phase | 63A (L1/L2), 126A (N) | 13mm² / 6AWG (L1/L2), 26mm² / 3AWG (N) | 2P-125A |
| Model | Cable Diameter | Max. Battery Current | Circuit Breaker Spec |
|---|---|---|---|
| 8KW Model | 34mm² / 2 AWG | 180A | 2P-200A |
| 10KW Model | 42mm² / 1 AWG | 220A | 2P-250A |
NOTICE:
The wire diameter is for reference only. If the distance between the PV array and the inverter or between the inverter and the battery is long, using a thicker wire will reduce voltage drop and improve system performance.
3.5 AC Input & Output Connection
Connect the live, neutral, and ground wires according to the diagram. Torque: 1.5NM.

Image Description: A diagram illustrating the AC input and output connections of the inverter. It shows the wiring terminals for AC IN and AC OUT, with live, neutral, and ground wires connected. The diagram emphasizes the correct position and order of cables.
DANGER:
- Before connecting AC inputs/outputs, open the circuit breaker to avoid electric shock. Do not operate with electricity.
- Ensure cable thickness is sufficient for requirements; too thin or poor quality cables are a serious safety hazard.
3.6 Battery Connection
Connect the positive and negative battery cables according to the diagram. Torque: 3NM.

Image Description: A diagram showing the battery connection terminals on the inverter. It clearly labels the BAT+ and BAT- terminals and illustrates how to connect the positive and negative cables from the battery.
DANGER:
- Before connecting the battery, open the circuit breaker to avoid electric shock. Do not operate with electricity.
- Ensure positive and negative terminals are connected correctly; reversed polarity can damage the inverter.
- Ensure cable thickness is sufficient for requirements; too thin or poor quality cables are a serious safety hazard.
3.7 PV Connection
Connect the positive and negative wires of the two PV strings according to the diagram. Torque: 1.2NM.

Image Description: A diagram detailing the PV (photovoltaic) connections to the inverter. It shows terminals for PV1+ PV1- and PV2+ PV2-, indicating how to connect two strings of PV modules. The diagram also includes a warning about maximum open circuit voltage.
DANGER:
- Before connecting PV, open the circuit breaker to avoid electric shock. Do not operate with electricity.
- Ensure the open circuit voltage of PV modules in series does not exceed the Max. Open Circuit Voltage of the inverter (500V for POW-SunSmart series), otherwise the inverter may be damaged.
3.8 Dry Contact Connection
Use a small screwdriver to push back the direction indicated by the arrow, then insert the communication cable (0.2~1.5mm²) into the dry junction port.

Image Description: A diagram showing the dry contact connection port on the inverter. It indicates where to insert the communication cable and highlights the various terminals for dry contact, parallel connection, and battery connections.
3.9 Grounding Connection
Ensure the grounding terminal is connected to the Grounding Busbar. Torque: 2NM.

Image Description: A diagram illustrating the grounding connection point on the inverter. It shows the grounding terminal and its location relative to other connections like AC IN, AC OUT, and battery terminals.
NOTICE:
The grounding cable should have a diameter of not less than 4mm² and be as close as possible to the grounding point.
3.10 Inverter Start-up Procedure
- After confirming reliable wiring and correct wiring sequence, restore the terminal cover.
- Close the circuit breaker of the battery.
- Press the rocker switch at the bottom of the inverter; the screen and indicator will light up, indicating the inverter is enabled.
- Close the circuit breakers for PV input, AC input, and AC output in sequence.
- Start loads one by one in order of power from small to large.
3.11 Parallel Connection
The inverter supports parallel operation for up to six units. Detailed wiring diagrams for single-phase, two-phase, and three-phase parallel connections are available in the full user manual (Appendix 10). Ensure all communication cables are securely connected and all inverters are connected to the same battery bank with correct polarity and cable sizing. The AC output wiring must also be consistent across all parallel inverters.
WARNING:
- For parallel connection, the PV array of each inverter must be independent.
- All solar storage inverters must be connected to the same battery bank.
- Ensure correct AC OUT wiring (L-to-L, N-to-N, PE-to-PE) and consistent AC source input.
- Use the provided DB15 standard computer cable for parallel communication.
- Before and after connecting the system, carefully refer to the system wiring diagrams to ensure all wiring is correct and reliable before power on.
- If adding a new inverter to an existing parallel system, disconnect battery input, PV input, AC input, and AC output, and power off all inverters before reconnecting.
4. Operation
4.1 Operation and Display Panel
The inverter features an LCD screen, LED indicators, and touchable keys for operation and monitoring.

Image Description: A close-up view of the inverter's circular display panel, highlighting the LCD screen, LED indicators (FAULT, CHARGE, AC/INV), and four touchable keys for navigation and selection. The diagram also shows a simplified flow of power from PV, AC IN, Battery, and to Load.
Touchable Keys:
- Enter/Exit: Enter/exit the setting menu.
- Up/Down Arrows: Navigate selections.
- Confirm/Enter: Confirm/enter selection in setting menu.
LED Indicators:
- AC/INV (Yellow): Steady on for utility grid bypass output, Flash for inverter output.
- CHARGE (Green): Steady on for charging complete, Flash for charging.
- FAULT (Red): Steady on for level-1 fault, Flash for level-2 fault, Off for level-3 or level-4 fault.
4.2 View Real-time Data
From the main screen, press the UP/DOWN keys to view real-time data such as voltage, current, power, and temperature from PV, battery, AC input, and load sides.
Video Description: A short video demonstrating how to navigate the inverter's display panel to view real-time data. It shows the screen cycling through various parameters like real-time voltage, real-time current, today's kWh, temperature, rated voltage, and rated current for PV, battery, AC IN, and LOAD sides.
4.3 Settings
The inverter offers extensive settings to customize its operation. Access the setup menu using the touchable keys. Parameters include AC output source priority, AC frequency, AC input voltage range, battery to mains voltage threshold, battery charging mode, max charging current, battery type, boost/float charging voltages and durations, discharge voltages, equalization settings, power saving mode, overload auto restart, buzzer alarm, and parallel mode settings.
For a complete list of parameters and their detailed descriptions, please refer to pages 26-37 of the full user manual (PDF).
AC Output Mode (Parameter 01)
- UTI (Utility Priority Output): Utility is first priority. Utility and solar power the load simultaneously when solar is available. Battery powers load only when utility is unavailable. (Priority: utility > solar > battery)
- SUB (Solar and Utility Hybrid Output - Default): Solar energy priority charging. If solar is insufficient, grid energy and solar energy hybrid charge. Battery discharges when off-grid.
- SOL (Solar Priority Output): Solar powers loads first. If solar is insufficient, utility supplements. Maximizes solar energy use, suitable for stable grids. (Priority: solar > utility > battery)
Battery Charging Mode (Parameter 06)
- SNU (Hybrid Charging - Default): Solar and utility charge the battery simultaneously. Solar is first priority, utility supplements when solar is insufficient. Fastest charging, suitable for areas with low power supply. (Source priority: solar > utility)
- OSO (Only Solar Charging): Solar charging only, no mains charging. Most energy-efficient, used in areas with good radiation.
Time-slot Charging/Discharging Function
The inverter allows setting specific time periods for mains charging and battery discharging based on local peak and valley tariffs. This optimizes energy usage and can reduce electricity costs. This function can be enabled/disabled via parameters 46 and 53, with charging/discharging slots set in parameters 40-45 and 47-52.
Battery Parameters
The inverter supports various battery types including Sealed Lead-Acid (SLd), Gel (GEL), Flooded (FLd), and User-defined (USER), as well as Li-ion batteries (N13, N14, L16, L15, L14). Each battery type has specific default and settable parameters for over-voltage cut-off, equalization charging, bulk charging, float charging, under-voltage alarm, discharge limits, and over-discharge delay. For detailed tables of these parameters, refer to pages 41-42 of the full user manual (PDF).
5. Communication
The inverter supports various communication interfaces for monitoring and control.
5.1 USB-B Port
Used to connect to a computer for reading and modifying device parameters via upper computer software. Software can be downloaded from the PowMr official website or by contacting support.
5.2 WIFI Port
Used to connect to a Wi-Fi/GPRS data acquisition module (purchased separately). This allows users to view operation status and parameters via a mobile APP. Scan the QR code in the manual to download the APP.
5.3 RS485/CAN Port
Used to connect to the BMS (Battery Management System) of Li-ion batteries. If communication is needed, contact PowMr for protocol information or software upgrades.
5.4 Dry Contact Port
This port has two functions: battery temperature sampling (reserved) and remote generator start/stop. For remote generator start/stop, ensure the generator has an ATS and supports this function.
6. Maintenance
To ensure optimum and long-lasting performance, we recommend checking the following items twice a year:
- Ensure airflow around the inverter is not blocked and remove any dirt or debris from the radiator.
- Check all exposed conductors for damage (sunlight, friction, dry rot, insect/rodent damage). Repair or replace as necessary.
- Verify indications and displays are consistent with equipment operation. Take corrective action for any faults or incorrect displays.
- Check all terminals for signs of corrosion, insulation damage, high temperatures, or burning/discoloration. Tighten terminal screws.
- Check for dirt, nesting insects, and corrosion. Clean the insect screen regularly.
- If the lightning arrester has failed, replace it promptly to prevent lightning damage.
DANGER:
Before any inspection or operation, ensure the inverter is disconnected from all power sources and the capacitor is fully discharged to avoid electric shock.
7. Troubleshooting
This section provides common fault codes, their causes, and remedies.
| Fault Code | Meaning | Causality | Remedy |
|---|---|---|---|
| / | No screen display | No power input, or device switch is off. | Check battery/PV air-switch, ensure switch is ON, press any button to exit sleep mode. |
| 01 | Battery under-voltage | Battery voltage is lower than parameter [14] value. | Charge battery until voltage is higher than parameter [14] value. |
| 03 | Disconnected battery | Battery not connected, or Li-ion BMS in discharge protection. | Check battery connection, circuit breaker, and BMS communication. |
| 04 | Battery over-discharge | Battery voltage is lower than parameter [12] value. | Manual reset: Power off and restart. Automatic reset: charge battery until voltage is higher than parameter [35] value. |
| 06 | Battery over-voltage when charging | Battery in overvoltage state. | Discharge battery until voltage is below over-voltage recovery point. |
| 13 | Bypass over-load (software detection) | Bypass output power or current overload for a period. | Reduce load power and restart device. Refer to item 11 of protection features. |
| 19 | Heat sink of PV input over-temperature | PV input heat sink temperature exceeds 90°C for 3s. | Resume normal charge and discharge when heat sink cools below over-temperature recovery. |
| 21 | Fan failure | Fan failure detected by hardware for 3s. | Manually toggle fan after switching off to check for blockage. |
| 28 | Utility input phase fault | AC input phase does not coincide with AC output phase. | Ensure AC input phase is same as AC output phase (e.g., in split-phase mode). |
NOTICE:
If you encounter product faults that cannot be solved by the methods listed above, please contact our after-sales service department for technical support. Do not disassemble the device yourself.
8. Protection Functions
The inverter incorporates multiple protection features to ensure safe and reliable operation.
| No. | Protection Feature | Instruction |
|---|---|---|
| 1 | PV current-limiting protection | If PV array current or power exceeds rated values, charging occurs at rated current/power. |
| 2 | PV input over-voltage | If PV voltage exceeds max allowed, a fault is reported, and PV boost stops. |
| 3 | PV night reverse current protection | Prevents battery discharge through PV module at night. |
| 4 | AC input over-voltage protection | If AC input voltage exceeds 140V, mains charging stops, and switches to inverter mode. |
| 5 | AC input under-voltage protection | If AC input voltage drops below 90V, utility charging stops, and switches to inverter mode. |
| 6 | Battery over-voltage protection | When battery voltage reaches over-voltage cut-off point, PV and utility charging stop. |
| 7 | Battery under-voltage protection | When battery voltage reaches under-voltage cut-off point, inverter stops battery discharge. |
| 8 | Battery over-current protection | If battery current exceeds allowed hardware limit, output switches off, and battery discharge stops. |
| 9 | AC output short-circuit protection | If short-circuit occurs, AC output immediately turns off. Normal operation restores after manual power-on. |
| 10 | Heat sink over-temperature protection | If internal temperature is too high, charging/discharging stops. Resumes when temperature returns to normal. |
| 11 | Inverter over-load protection | Resumes output after 3 minutes for overloads. Multiple consecutive overloads will switch off output until restart. |
| 12 | AC output reverse | Prevents AC backflow from battery inverter to bypass AC input. |
| 13 | Bypass over-current protection | Built-in AC input over-current protection circuit breaker. |
| 14 | Bypass phase inconsistency protection | If bypass input and inverter split phases don't match, inverter disables switching to bypass output. |
9. Technical Specifications
The following table outlines the key technical specifications for the PowMr POW-SunSmart 8KP and 10KP models.

Image Description: A comprehensive table detailing the technical specifications of the PowMr POW-SunSmart 8KP and 10KP models. It covers INVERTER OUTPUT (Rated Output Power, Max. Peak Power, Rated Output Voltage, Rated AC Frequency, Waveform, Switch Time, Parallel Number, Overload Protection), BATTERY (Battery Type, Rated Battery Voltage, Voltage Range, Max. MPPT Charging Current, Max. Mains/Generator Charging Current, Max. Hybrid Charging Current), PV INPUT (Num. of MPP Trackers, Max. PV array power, Max. Input current, Max. Voltage of Open Circuit, MPPT Voltage Range), MAINS/GENERATOR INPUT (Input Voltage Range, Frequency Range, Bypass Overload Current), EFFICIENCY (MPPT Tracking Efficiency, Max. Battery Inverter Efficiency), GENERAL (Dimensions, Weight, Protection Level, Operating Temperature Range, Noise, Cooling Method), COMMUNICATION (Embedded Interfaces, External Modules), and CERTIFICATION (Safety, EMC, RoHS).
For detailed specifications, please refer to pages 54-55 of the full user manual (PDF).
10. User Tips
Based on general best practices for hybrid inverters:
- Regular Monitoring: Utilize the SmartESS App and the inverter's display panel to regularly monitor system performance, battery status, and energy flow. This helps in early detection of any anomalies.
- Optimize Settings: Experiment with the different AC Output Modes (UTI, SUB, SOL) and Battery Charging Modes (SNU, OSO) to find the most efficient configuration for your specific energy needs and local electricity tariffs. The time-slot charging/discharging function can be particularly useful for cost savings.
- Battery Health: Pay close attention to battery parameters and ensure they are correctly configured for your battery type (Lead-acid, Li-ion). Proper charging and discharging settings are crucial for extending battery lifespan.
- Cleanliness: As noted in the manual, regularly clean the insect screen and ensure adequate airflow to prevent overheating, especially in dusty environments.
11. Warranty and Support
The PowMr POW-SunSmart 10KP Hybrid Inverter comes with an 18-month warranty.
For technical support, troubleshooting assistance, or warranty claims, please contact PowMr customer service. You can find contact details on the last page of the official user manual PDF.
Official User Manual (PDF): For detailed instructions, wiring diagrams, and comprehensive parameter tables, please refer to the complete user manual available at: View User Manual (PDF)