1. Product Overview

The JUNCTEK PLS500 Pulse Signal Generator is a high-precision, multi-functional signal generation device featuring a wide frequency range (1 Hz–500 kHz) and fine step adjustment. It supports dual-channel independent or synchronized operation and is widely applicable in precision testing, motor control, pulse modulation, and related fields.

The device is capable of flexibly generating pulse signals with adjustable frequency, duty cycle, phase, and dead time, providing stable and reliable performance for demanding applications. It features a 1.8-inch color screen with encoder operation for easy and fast adjustment, and supports on-load mode. It offers high-frequency precise control with low-frequency stability, with a 1Hz step suitable for frequency scanning and fine tuning. The duty cycle is arbitrarily settable from 0-100% with a 0.1% step, maintaining waveform integrity. Dual-channel phase-shift testing is made more convenient, allowing simulation of industrial control and servo synchronization signals. Its super-fast 10ns rising edge is suitable for testing driving and switching devices, maintaining clean, sharp waveforms even at high frequencies.

Applications of PLS500 Pulse Signal Generator
Wider range of applications for the PLS500, including engineering R&D, automation systems, teaching experiments, and electronics DIY.

2. Package Contents

Upon unpacking your PLS500 Pulse Signal Generator, please verify that all items listed below are present and in good condition:

  • PLS500 Main Unit × 1
  • Quick Start Guide × 1
  • 2-pin Green Terminal × 1
  • 3-pin Green Terminal × 1
PLS500 Pulse Signal Generator Package List
Contents of the PLS500 Pulse Signal Generator package.

3. Product Specifications

Parameter ItemSpecifications
Output ChannelCH1 + CH2
Operating VoltageDC 5-24V
Frequency Range1Hz-500kHz
Step Size1Hz
Frequency Accuracy1kHz-10kHz: ±0.2%
10kHz-50kHz: ±0.4%
50kHz-500kHz: ±2%
Duty Cycle Range0% - 100% (0.1% step)
Phase Range0° – 359° (1° step)
Rise Time10ns
T0 Delay Output Time00.000s-60.000s (minimum step 0.001s)
T1 Positive Pulse Width00.000s-60.000s (minimum step 0.001s)
T2 Negative Pulse Width00.000s-60.000s (minimum step 0.001s)
Pulse Count1 – 60000 or ∞ (continuous)
Dead Time0–91 ns (7 ns step); 0.1–20.0 µs (0.1 µs step)
PWM ModeConventional/Complementary (with dead zone)
Operation ModeEncoder + button
Display1.8-inch color screen
Product Dimensions108 × 63 × 24mm
Cut-out Dimensions100 × 56mm
Product Specifications Table for PLS500
Detailed product specifications for the PLS500 Pulse Signal Generator.

4. Safety Precautions

  • Power Supply Requirement: Ensure the input voltage remains within DC 5–25 V. Exceeding this range may damage the device.
  • Parameter Adjustment: Always observe parameter limits to avoid improper settings that could affect performance or cause damage.
  • Operating Environment: Avoid use in humid environments, high temperatures, or areas with strong electromagnetic interference.
  • Output Protection: Do not short-circuit the output terminals, as this may cause malfunction or safety hazards.
  • Input Wiring: Do not reverse the input polarity when the power supply is disconnected, as this may damage internal circuitry.

5. Setup

5.1. Wiring Diagram

Connect the PLS500 according to the following diagram. Ensure correct polarity for the DC 5V~25V input.

PLS500 Wiring Diagram
Wiring connections for the PLS500 Pulse Signal Generator, showing input and output terminals.

5.2. Output Capabilities

The PLS500 supports both no-load and load modes:

  • No-load mode: Input DC voltage 5-25V, output voltage 5-24V continuously adjustable. Features an integrated buck-boost module.
  • Load mode (real-drive operation): Input DC voltage range 5-25V. Output voltage is approximately 0.4V lower than the input voltage. Capable of directly driving small load devices such as optocoupler/MOS driver boards and small relays.
PLS500 Output Capabilities Diagram
Diagram illustrating no-load and load mode output capabilities of the PLS500.

6. Operating Instructions

6.1. Key and Control Description

The PLS500 features an intuitive control panel with an encoder and buttons for easy operation.

PLS500 Control Panel Layout
Front view of the PLS500 control panel with buttons and encoder.
  • Rotary Encoder (with push function): Used to adjust values, select parameters, and confirm settings.
  • M Key: Short press to recall parameters; short press again to save parameters.
  • UP (↑) / DOWN (↓) Keys: Move up or down to select the parameter to be adjusted.
  • SET Key: Enter the system settings menu.
  • LEFT (←) / RIGHT (→) Keys: Move the cursor left or right to select the digit position.
  • MOD Key: Switch between interfaces: PWM Interface → PWM Sync Interface (Normal/Complementary) → CH1 Pulse Interface → CH2 Pulse Interface.
  • OUT Key: Turn output ON or OFF. Long press to lock the keypad.

6.2. PWM Interface

This interface allows for independent control of CH1 and CH2 PWM signals.

PLS500 PWM Interface Screenshot
Screenshot of the PLS500 PWM Interface showing frequency, duty cycle, and voltage settings.
  • CH1 Frequency Setting: Short press the rotary encoder to select the parameter. Use the UP/DOWN keys to select CH1 frequency, LEFT/RIGHT keys to position the cursor, rotate the encoder to adjust the value, then short press again to confirm.
  • CH1 Duty Cycle Setting: Follow the same operation procedure to adjust CH1 duty cycle.
  • CH2 Frequency Setting: Select and adjust the CH2 frequency using the same method.
  • CH2 Duty Cycle Setting: Select and adjust the CH2 duty cycle using the same method.
  • Output Voltage Adjustment (Internal Power Mode): Select the output voltage parameter and adjust the voltage value using the rotary encoder.
  • Output Control: Short press the OUT key to enable or disable signal output. 'ON' indicates output enabled; 'OFF' indicates output disabled.
  • Unit Switching: Short press the LEFT or RIGHT key to switch frequency units between Hz and kHz.
PWM Waveform Example on Oscilloscope
Example of PWM waveforms displayed on an oscilloscope.

6.3. PWM Synchronization Interface

Short press the MOD key repeatedly to switch to the PWM synchronization interface. In this interface, CH1 and CH2 operate synchronously with identical frequency and duty cycle. Both Normal Mode and Complementary Mode are supported and can be switched using the LEFT/RIGHT keys.

6.3.1. PWM Sync – Normal Mode

PLS500 PWM Sync Normal Mode Screenshot
Screenshot of the PLS500 PWM Synchronization Interface in Normal Mode.
  • Frequency Setting: Adjust frequency using the rotary encoder and navigation keys.
  • Duty Cycle Setting: Adjust duty cycle using the same procedure.
  • Output Voltage Adjustment (Internal Power Mode): Adjust output voltage as required.
  • Phase Setting: Adjust the phase angle using the rotary encoder.
  • Output Control: Use the OUT key to turn output ON or OFF.

6.3.2. PWM Sync – Complementary Mode

PLS500 PWM Sync Complementary Mode Screenshot
Screenshot of the PLS500 PWM Synchronization Interface in Complementary Mode.
  • Frequency Setting: Adjust frequency as described above.
  • Duty Cycle Setting: Adjust duty cycle as described above.
  • Output Voltage Adjustment (Internal Power Mode): Adjust output voltage as required.
  • Dead Time Setting: Select the dead time parameter and adjust using the rotary encoder. Dead time range: 0–91 ns (7 ns step); 0.1–20.0 µs (0.1 µs step).
  • Output Control: Use the OUT key to turn output ON or OFF.

6.4. CH1 Pulse Interface

This interface allows for precise control over individual pulse parameters for Channel 1.

PLS500 CH1 Pulse Interface Screenshot
Screenshot of the PLS500 CH1 Pulse Interface showing T0, T1, T2, and pulse count settings.
  • T0 Delay Time Setting: Defines the delay from the initial idle state to the first valid pulse output.
  • T1 Positive Pulse Width Setting: Controls the duration of the high-level state.
  • T2 Negative Pulse Width Setting: Controls the duration of the low-level state.
  • Pulse Count (Num) Setting: Set the number of output pulses (1–60,000) or ∞ for continuous output.
  • Output Voltage Adjustment (Internal Power Mode): Adjust output voltage as required.
  • Output Control: Short press the OUT key to enable or disable output.

Note: For non-continuous output mode, after setting the pulse count, short press the rotary encoder to remove the cursor. Rotating the encoder will then trigger pulse output.

Pulse Waveform Example with T0, T1, T2
Diagram illustrating T0 (Delay Time), T1 (Positive Pulse Width), and T2 (Negative Pulse Width) in a pulse waveform.

6.5. CH2 Pulse Interface

The operation and parameters for the CH2 Pulse Interface are identical to the CH1 Pulse Interface, including:

  • T0 Delay Time
  • T1 Positive Pulse Width
  • T2 Negative Pulse Width
  • Pulse Count (1–60,000 or ∞)
  • Output Voltage Adjustment
  • Output Control

Pulse triggering behavior is the same as CH1.

6.6. System Settings Menu

Access the system settings by pressing the SET key. Here you can configure various device parameters.

PLS500 System Settings Menu Screenshot
Screenshot of the PLS500 System Settings Menu.
  • 01. Language: Chinese / English selectable.
  • 02. Brightness: Adjustable from 1% to 100%.
  • 03. Auto Screen OFF: Disable or set 1–60 seconds of inactivity before the screen turns off.
  • 04. Vout Power Supply:
    • Internal Power Supply: Output voltage adjustable from 5–24 V. Signal output only, no load-driving capability.
    • External Power Supply: Output voltage follows input voltage (approximately 0.4 V lower) and provides limited load capability.
  • 05. PWM Mode: Normal Mode / Complementary Mode.
  • 06. Lower Frequency: Adjustable within 0–500 kHz.
  • 07. Upper Frequency: Adjustable within 0–500 kHz.
  • 08. Lower Duty: Adjustable within 0%–100%.
  • 09. Upper Duty: Adjustable within 0%–100%.
  • 10. Restore Defaults: Select Yes / No to reset all parameters to factory defaults.

7. Maintenance

The PLS500 Pulse Signal Generator is designed for durability and reliable performance. To ensure its longevity, keep the device clean and free from dust. Avoid exposing it to extreme temperatures or humidity. Do not attempt to disassemble the unit, as this will void any potential warranty and may cause damage.

8. Troubleshooting

If you encounter any issues with your PLS500, please refer to the operating instructions to ensure all settings are correct. Verify power connections and input voltage. If problems persist, contact customer support for assistance. A user manual PDF is available for more detailed guidance: PLS500 User Manual (PDF).

9. Warranty and Support

JUNCTEK products are manufactured to high-quality standards. For warranty information and technical support, please refer to the documentation provided with your purchase or contact the seller directly. Keep your purchase receipt as proof of purchase.

10. Product Demonstration Video

Watch this video for a visual demonstration of the PLS500 Pulse Signal Generator's features and operation.

Product demonstration of the PLS500 Pulse Signal Generator.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.