1. Introduction
This is a multi-function inverter/charger, combining functions of inverter, solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
1.1 Features
- Pure sine wave inverter
- Configurable input voltage range for home appliances and personal computers via LCD setting
- Configurable battery charging current based on applications via LCD setting
- Configurable AC/Solar Charger priority via LCD setting
- Compatible to mains voltage or generator power
- Auto restart while AC is recovering
- Overload/Over temperature/short circuit protection
- Smart battery charger design for optimized battery performance
- Cold start function
- RS485 is used to communicate with BMS and adjust the charging current of inverter according to battery demand
- It can work with or without batteries
- Intelligent fan speed adjustment, which adjusts the fan speed according to temperature, load and charging current
- Built-in MPPT, operating voltage range 55V~450V open circuit voltage 500Voc
- RGB lamp, which displays different colors according to inverter status
- WIFI remote monitoring (optional)
- Offline upgrade function, firmware can be upgraded through COM port
- Grid-connected
- Built-in anti-dust kit for harsh environment
- In battery-free mode, PV systems deliver a better user experience when powering loads
- Equipped with lithium battery activation function
- Dual output
1.2 Basic System Architecture
The following illustration shows basic application for this inverter/charger. It also includes following devices to have a complete running system: Generator or Utility, and PV modules.
This inverter can power all kinds of appliances in home or office environment, including motor-type appliances such as tube light, fan, refrigerator and air conditioner.

2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries and all appropriate sections of this manual.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION - Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries and other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to INSTALLATION section of this manual for the details.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS -This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulation to install this inverter.
- NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
3. Installation (Setup)
3.1 Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside of package: The unit x 1, User manual x 1.
3.2 Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level in order to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approx. 20 cm to the side and approx. 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Make sure that other objects and surfaces are left with enough space from the machine to ensure adequate heat dissipation and that there is enough room to remove the wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two M6 screws.
3.3 Wiring Guide Video
3.4 Battery Connection
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed. Please refer to typical amperage in below table as required fuse or breaker size.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable as below.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 4.2KW/6.2KW | 1 x 2AWG | 25 | 2 Nm |
Please follow below steps to implement battery connection:
- Remove insulation sleeve 18 mm for positive and negative conductors.
- Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Connect all battery packs as shown in the wiring guide video.
- Insert the battery wires flatly into battery connectors of inverter and make sure the bolts are tightened with torque of 2 Nm in clockwise direction. Make sure polarity at both the battery and the inverter/charge is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.
WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage in series.
CAUTION!! Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).
3.5 AC Input/Output Connection
CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is 32A for 4.2KW and 50A for 6.2KW.
CAUTION!! There are two terminal blocks with "IN" and "OUT" markings. Please do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 4.2KW | 12 AWG | 4 | 1.2 Nm |
| 6.2KW | 10 AWG | 6 | 1.2 Nm |
Please follow below steps to implement AC input/output connection:
- Before making AC input/output connection, be sure to open DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. And shorten phase L and neutral conductor N 3 mm.
- Insert AC input wires according to polarities indicated on terminal block (L→LINE (brown or black), N→Neutral (blue)) and tighten the terminal screws.
WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
- Then, insert AC output wires according to polarities indicated on terminal block (L→LINE (brown or black), N→Neutral (blue)) and tighten terminal screws.
- Make sure the wires are securely connected.
CAUTION: Appliances such as air conditioner are required at least 2~3 minutes to restart because it's required to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check manufacturer of air conditioner if it's equipped with time-delay function before installation. Otherwise, this inverter/charger will trig overload fault and cut off output to protect your appliance but sometimes it still causes internal damage to the air conditioner.
3.6 PV Connection
CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between inverter and PV modules.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 4.2KW/6.2KW | 1 x 12AWG | 4 | 1.2 Nm |
PV Module Selection:
When selecting proper PV modules, please be sure to consider below parameters:
- Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter (500Vdc).
- Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
| INVERTER MODEL | 4.2KW | 6.2KW |
|---|---|---|
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| PV Array MPPT Voltage Range | 60Vdc~450Vdc | |
| IMax.PV | 27A | |
PV Module Wire Connection:
Please follow below steps to implement PV module connection:
- Remove insulation sleeve 10 mm for positive and negative conductors.
- Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Check correct polarity of wire connection from PV modules and PV input connectors. Then, connect positive pole (+) of connection wire to positive pole (+) of PV input connector. Connect negative pole (-) of connection wire to negative pole (-) of PV input connector. Recommended tool: 4mm blade screwdriver.
3.7 Final Assembly
After connecting all wirings, please put bottom cover back by screwing two screws.
3.8 Communication Connection
Wi-Fi cloud communication (optional):
Please use supplied communication cable to connect to inverter and Wi-Fi module. Download APP and installed from APP store, and Refer to "Wi-Fi Plug Quick Installation Guideline" to set up network and registering. The inverter status would be shown by mobile phone APP or webpage of computer.
GPRS cloud communication (optional):
Please use supplied communication cable to connect to inverter and GPRS module, and then applied external power to GPRS module. Download APP and installed from APP store, and Refer to "GPRS RTU Quick Installation Guideline" to set up network and registering. The inverter status would be shown by mobile phone APP or webpage of computer.
Battery communication
The communication between the battery and the inverter can be realized through the battery communication interface, so that the inverter and the lithium battery can exchange information (Baud rate: 9600).
Lithium battery and inverter connection:
If choosing lithium battery for the inverter, only lithium batteries that have been matched with BMS communication protocol are allowed.
- Connect the battery according to the recommended battery cable specifications.
- Insert the ring terminal of the battery cable into the battery connector of the inverter flatly, and ensure that the bolts are tightened with a torque of 2-3 Nm. Make sure that the polarities of the battery and inverter are connected correctly, and that the ring terminal is tightened with the battery terminal.
- Connect one side of RJ45 cable to the BMS communication port of inverter.
- Insert the other side of RJ45 cable into RS485 communication port on lithium battery.
NOTE: If you choose a lithium battery, please make sure to connect the battery and inverter with BMS communication cable, and select the battery type as "LIB-485" mode.
Communication And Setting Of Lithium Battery
Connect the RJ45 communication cable between inverter and battery. Please confirm that the lithium battery BMS port's PIN is correspond with the inverter BMS communication port. The inverter BMS port'PIN definition as below:
Pin number Port definitions 1 RS485B 2 RS485A 3 NG 4 NG 5 NG 6 NG 7 RS485A 8 RS485B In order to communicate with the lithium battery BMS, you should press the "ENTER" button for a long time, and set the battery type as "LIB-485" in program 05. Then select the matching battery protocol in Program 43.
CAUTION: When the battery type is set to "LIB-485", the setting items 12, 13 and 29 are displayed in percentage.
4. Operation
4.1 Power ON/OFF
Once the unit has been properly installed and the batteries are connected well, simply press On/Off switch (located on the button of the case) to turn on the unit.
4.2 Operation and Display Panel
The operation and display panel, shown in below chart, is on the front panel of the inverter. It includes three indicators, four function keys and a LCD display, indicating the operating status and input/output power information.
| LED Indicator | Messages |
|---|---|
| INV/AC (Green Solid On) | Output is powered by utility in Line mode. |
| INV/AC (Green Flashing) | Output is powered by battery or PV in battery mode. |
| CHG (Green Solid On) | Battery is fully charged. |
| CHG (Green Flashing) | Battery is charging. |
| FAULT (Red Solid On) | Fault occurs in the inverter. |
| FAULT (Red Flashing) | Warning condition occurs in the inverter. |
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4.3 LCD Display Icons
The LCD display provides various icons to indicate the system status. Here are some key icons and their descriptions:
| Icon | Function description |
|---|---|
| Input Source Information | |
| AC Input Icon | Indicates the AC input. |
| PV Input Icon | Indicates the PV input. |
| 8.8.8 KW A | Indicates input voltage, input frequency, PV voltage, charger current (if PV in charging for 3.6KW models), charger power, battery voltage. |
| Configuration Program and Fault Information | |
| 8.8.8 (Program Number) | Indicates the setting programs. |
| 8.8.8 (Warning/Fault Code) | Indicates the warning and fault codes. |
| 8.8.8 (Flashing) | Warning: Flashing with warning code. |
| 8.8.8 (Solid) | Fault: Lighting with fault code. |
| Output Information | |
| 8.8.8 KW VA % | Indicates output voltage, output frequency, load percent, load in VA, load in Watt and discharging current. |
| Battery Information | |
| Battery Icon | Indicates battery status. |
| Load Information | |
| OVER LOAD | Indicates overload. |
| House Icon | Indicates connected loads. |
| Mode Operation Information | |
| Mains Connection Icon | Indicates unit connects to the mains. |
| PV Panel Connection Icon | Indicates unit connects to the PV panel. |
| AC BYPASS | Indicates load is supplied by utility power. |
| Utility Charger Circuit Icon | Indicates the utility charger circuit is working. |
| DC/AC Inverter Circuit Icon | Indicates the DC/AC inverter circuit is working. |
| Mute Operation | |
| Speaker with X Icon | Indicates unit alarm is disabled. |
4.4 LCD Setting
After pressing and holding ENTER button for 3 seconds, the unit will enter setting mode. Press "UP" or "DOWN" button to select setting programs. And then, press "ENTER" button to confirm the selection or ESC button to exit.
Key settings include:
- Output source priority (Program 01): Configure how the inverter prioritizes power sources (Utility first, Solar first, SBU priority, MKS priority).
- Maximum charging current (Program 02): Set the total charging current for solar and utility chargers.
- AC input voltage range (Program 03): Select voltage range for appliances or UPS.
- Power saving mode enable/disable (Program 04): Enable to turn off inverter output when connected load is low.
- Battery type (Program 05): Select battery type (AGM, Flooded, User-Defined, LIB-485).
- Auto restart (Program 06, 07): Enable/disable auto restart on overload or over temperature.
- Output frequency (Program 09): Set output frequency (50Hz/60Hz).
- Output voltage (Program 10): Set output voltage (220V/230V/240V).
- Setting voltage point back to utility source (Program 12): For SBU priority or Solar first modes, set the battery voltage point to switch back to utility.
- Setting voltage point back to battery mode (Program 13): For SBU priority or Solar first modes, set the battery voltage point to switch back to battery.
- Lithium battery protocol (Program 43): Select the matching battery protocol for LIB-485 mode (PYLON, PACE).
- Dual output functional voltage point (Program 42): Enter the functional voltage point for dual output.
4.5 Operating Mode Description
The inverter operates in various modes depending on power availability and settings:
- Standby Mode: The inverter is not actively supplying output but can charge the battery.
- Line Mode: The unit provides output power from the mains and can charge the battery.
- Grid-Tie Operation: The inverter operates in hybrid mode, supplying loads and charging the battery, with excess energy fed to the grid.
- Battery Mode: The unit provides output power from the battery and solar.
4.6 RGB Light (option)
The inverter features an RGB lamp to indicate its status:
- Green Light: Inverter state.
- Blue Light: Utility state.
- Red Light: Failure state.
4.7 Battery Equalization Description
Battery equalization is a function to reverse the buildup of negative chemical effects like stratification and remove sulfate crystals, which can reduce battery capacity. It is recommended to equalize batteries periodically.
How to Apply Equalization Function
You must enable battery equalization function in monitoring LCD setting program 30 first. Then, you may apply this function in device by either one of following methods:
- Setting equalization interval in program 35.
- Active equalization immediately in program 36.
When to Equalize
In float stage, when the setting equalization interval (battery equalization cycle) is arrived, or equalization is active immediately, the controller will start to enter Equalize stage.
Equalize charging time and timeout
In Equalize stage, the controller will supply power to charge battery as much as possible until battery voltage raises to battery equalization voltage. Then, constant-voltage regulation is applied to maintain battery voltage at the battery equalization voltage. The battery will remain in the Equalize stage until setting battery equalized time is arrived. If battery equalized time is expired and battery voltage doesn't rise to battery equalization voltage point, the charge controller will extend the battery equalized time until battery voltage achieves battery equalization voltage. If battery voltage is still lower than battery equalization voltage when battery equalized timeout setting is over, the charge controller will stop equalization and return to float stage.
4.8 Mains and Lithium Battery Activation Function
- After 90s of mains power connection to the inverter, the machine is connected to the mains and starts to work.
- The inverter is in lithium battery mode (item 05 is Llb or Llb-485). After the mains is connected, the battery is not connected, and the mains activation function is automatically enabled.
5. Maintenance
5.1 Clearance and Maintenance for Anti-Dust Kit
Overview
Every inverter is already installed with an anti-dust kit from the factory. The inverter will automatically detect this kit and activate an internal thermal sensor to adjust internal temperature. This kit also keeps dust from your inverter and increases product reliability in harsh environments.
Clearance and Maintenance Steps
- Please loosen the screw in counterclockwise direction on the top of the inverter.
- Then, the dustproof case can be removed, and the air filter foam taken out.
- Clean the air filter foam and dustproof case. After clearance, re-assemble the dust-kit back to the inverter.
NOTICE: The anti-dust kit should be cleaned from dust every one month.
6. Troubleshooting
6.1 Fault Reference Code
| Fault Code | Fault Event | What to do |
|---|---|---|
| 01 | Fan is locked when inverter is off. | Return to repair center. |
| 02 | Over temperature | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. |
| 03 | Battery voltage is too high | Check if spec and quantity of batteries are meet requirements. |
| 04 | Battery voltage is too low | 1. Re-charge battery. 2. Replace battery. |
| 05 | Output short circuited or over temperature is detected by internal converter components. | Check if wiring is connected well and remove abnormal load. |
| 06 | Output voltage is too high. | 1. Reduce the connected load. 2. Return to repair center. |
| 07 | Overload time out | Reduce the connected load by switching off some equipment. |
| 08 | Bus voltage is too high | Restart the unit, if the error happens again, please return to repair center. |
| 09 | Bus soft start failed | Restart the unit, if the error happens again, please return to repair center. |
| 51 | Over current or surge | Restart the unit, if the error happens again, please return to repair center. |
| 52 | Bus voltage is too low | Restart the unit, if the error happens again, please return to repair center. |
| 53 | Inverter soft start failed | Restart the unit, if the error happens again, please return to repair center. |
| 55 | Over DC voltage in AC output | Restart the unit, if the error happens again, please return to repair center. |
| 57 | Current sensor failed | Restart the unit, if the error happens again, please return to repair center. |
| 58 | Output voltage is too low | Restart the unit, if the error happens again, please return to repair center. |
| 59 | PV voltage is over limitation | Restart the unit, if the error happens again, please return to repair center. |
6.2 Warning Indicator
| Warning Code | Warning Event | Audible Alarm |
|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second |
| 03 | Battery is over-charged | Beep once every second |
| 04 | Low battery | Beep once every second |
| 07 | Overload | Beep once every 0.5 second |
| 10 | Output power derating | Beep twice every 3 seconds |
| 15 | PV energy is low. | Beep twice every 3 seconds |
| 16 | AC voltage is over limitation | Beep twice every 3 seconds |
| E9 | Battery equalization | None |
| 6P | Battery is not connected | None |
7. Specifications
7.1 Line Mode Specifications
| INVERTER MODEL | 4.2KW | 6.2KW |
|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | |
| Nominal Input Voltage | 230Vac | |
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) | |
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) | |
| High Loss Voltage | 280Vac±7V | |
| High Loss Return Voltage | 270Vac±7V | |
| Max AC Input Voltage | 300Vac | |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | |
| Low Loss Frequency | 40±1Hz | |
| Low Loss Return Frequency | 42±1Hz | |
| High Loss Frequency | 65±1Hz | |
| High Loss Return Frequency | 63±1Hz | |
| Output Short Circuit Protection | Circuit Breaker | |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | |
7.2 Inverter Mode Specifications
| INVERTER MODEL | 4.2KW | 6.2KW |
|---|---|---|
| Rated Output Power | 4.2KW | 6.2KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230Vac±5% | |
| Output Frequency | 50Hz | |
| Peak Efficiency | 93% | |
| Overload Protection | 3s@≥150% load; 30s@101%~150% load | |
| Surge Capacity | 2* rated power for 3 seconds | |
| Nominal DC Input Voltage | 24Vdc | 48Vdc |
| Cold Start Voltage | 23.0Vdc | 46.0Vdc |
| No Load Power Consumption | 25W | 50W |
7.3 Two Load Output Power
| INVERTER MODEL | 4.2KW | 6.2KW |
|---|---|---|
| Full Load | 4200W | 6200W |
| Maximum Main Load | 4200W | 6200W |
| Second Load Range | 840W~2940W | 1240W~4340W |
| Main Load Cut Off Voltage | 26VDC | 52VDC |
| Main Load Return Voltage | 27VDC | 54VDC |
7.4 Charge Mode Specifications
| INVERTER MODEL | 4.2KW | 6.2KW |
|---|---|---|
| Charging Algorithm | 3-Step | |
| AC Charging Current (Max) | 100Amp (@VI/P=230Vac) | |
| Bulk Charging Flooded Battery | 29.2 | 58.4 |
| AGM / Gel Battery Voltage | 28.2 | 56.4 |
| Floating Charging Voltage | 27Vdc | 54Vdc |
| Max. PV Array Power | 6200W | 8000W |
| Nominal PV Voltage | 240Vdc | 360Vdc |
| PV Array MPPT Voltage Range | 60Vdc~450Vdc | |
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| Max Charging Current (AC charger plus solar charger) | 120Amp | |
7.5 General Specifications
| INVERTER MODEL | 4.2KW | 6.2KW |
|---|---|---|
| Safety Certification | CE | |
| Operating Temperature Range | -10°C to 50°C | |
| Storage temperature | -15°C~60°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Dimension (D*W*H), mm | 423×344×112 | |
| Net Weight, kg | 7.2 | 8.2 |
7.6 Appendix: Approximate Back-up Time Table
| Model | Load (W) | Backup Time @ 24Vdc 100Ah (min) | Backup Time @ 24Vdc 200Ah (min) |
|---|---|---|---|
| 4.2KW | 300 | 449 | 1100 |
| 600 | 222 | 525 | |
| 900 | 124 | 303 | |
| 1200 | 95 | 227 | |
| 1500 | 68 | 164 | |
| 1800 | 56 | 126 | |
| 2100 | 48 | 108 | |
| 2400 | 35 | 94 | |
| 2700 | 31 | 74 | |
| 3200 | 28 | 67 | |
| 3600 | 25 | 60 | |
| 4200 | 22 | 53 | |
| 6.2KW | 500 | 613 | 1288 |
| 1000 | 268 | 613 | |
| 1500 | 158 | 402 | |
| 2000 | 111 | 271 | |
| 2500 | 90 | 215 | |
| 3200 | 76 | 182 | |
| 3500 | 65 | 141 | |
| 4000 | 50 | 112 | |
| 4500 | 44 | 100 | |
| 5000 | 40 | 90 | |
| 6200 | 36 | 80 |
Note:
- Backup time depends on the quality of the battery, age of battery and type of battery. Specifications of batteries may vary depending on different manufacturers.
- The final interpretation right of this product belongs to the company.
8. User Tips
- Battery Compatibility: The inverter offers various battery type options (GEL, Sealed Lead Acid, Flooded Lead Acid, Lithium, User Defined). Ensure you select the correct battery type in the settings (Program 05) for optimal performance and charging.
- Intelligent Cooling: The inverter features intelligent fan speed adjustment. During mains operation, cooling fans activate only when necessary due to heating, contributing to quieter operation and energy efficiency.
- Power Saving Mode: Consider enabling the power saving mode (Program 04) to conserve energy. This mode will turn off the inverter output when connected loads are very low or not detected.