1. Product Overview
The PowMr POW-LVM Series Hybrid Solar Inverter is an advanced solution integrating solar energy storage, AC charging, and pure sine wave output functions. Designed with DSP control and advanced algorithms, it offers fast response, high reliability, and compliance with industrial standards. This inverter is suitable for various applications, including RV systems, trailers, boats, outdoor camping, and solar home systems.
It features four charging modes and two output modes to meet diverse application requirements. The inverter is compatible with both 24V/48V lithium-ion and lead-acid batteries, with user-definable settings. It supports a maximum PV charging current of 80A, a maximum AC charging current of 40A, and a maximum hybrid charging current of 80A. The AC input voltage range is 90-140Vac, and the PV operating voltage range is 120-450Vdc.






2. Package Contents
Upon opening the package, you should find the following items:
- 1 x LVM Series Inverter
- 1 x Installation Manual
- 1 x Installation Guide Card
- 1 x Warranty Card
- 2 x Battery Terminals
- 2 x Battery Terminal Screws
- 4 x Spare Screws
3. Safety Information
Before installation, ensure the safety and reliability of the installation environment. It is recommended to install the inverter in a dry, temperature-appropriate, and well-ventilated room. Leave a gap of about 20cm on both sides of the inverter and about 50cm at the top and bottom to ensure air circulation around the equipment and sufficient heat dissipation.
Always disconnect all power sources before performing any wiring or maintenance. Use appropriate personal protective equipment (PPE) during installation. Ensure all connections are firm and secure to prevent electrical hazards.
4. Installation
The inverter is designed for wall mounting. After confirming the installation location, fix the equipment to the wall using the recommended M5 screws. For demonstration purposes, zip ties are used to secure the inverter to an installation board.
Ensure the mounting surface is sturdy enough to support the inverter's weight (8KG for 3KW, 13KG for 5KW).
5. Wiring
Before starting the wiring, prepare cables and circuit breakers that meet the specifications. The cable AWG (American Wire Gauge) and circuit breaker specifications are determined by the maximum current the cable needs to bear. The instruction manual provides the matching wire AWG and circuit breaker specifications.
For connecting the battery, use 2 AWG wires. For AC input and output, use 10 AWG wires. Note that the AC input terminal requires a grounding connection, so prepare three 10 AWG cables for the AC input side (Live, Neutral, Ground). For PV input, use 12 AWG wires. It is highly recommended to use different colored wires (e.g., red for positive, black for negative, yellow/green for ground) to distinguish between positive, negative, live, neutral, and ground wires to reduce the risk of reverse connection and other potential errors.
Additionally, include four two-pole circuit breakers in your setup: two DC circuit breakers rated at 25A and 160A respectively, and two 40A AC circuit breakers. It's crucial to have a separate circuit breaker for each input and output line to improve safety and simplify maintenance.

Wiring Steps:
- Prepare Wires: Ensure all wires are correctly sized and stripped.
- Remove Port Cover: Unscrew the two screws on the port cover at the bottom of the inverter and remove it.
- Connect Battery Cables: Match positive terminals with positive cables (red) and negative terminals with negative cables (black). Securely tighten the connections.
- Connect Solar Panel (PV) Cables: Connect the PV input cables (12 AWG) to the designated PV terminals. Ensure correct polarity.
- Connect AC Input and Output Cables: Connect the AC input cables (10 AWG, including ground) and AC output cables (10 AWG) to their respective terminals.
- Grounding: Properly ground the inverter using the grounding port on the unit. Try to keep the grounding point as close as possible to the inverter for maximum effectiveness.
- Double-Check Connections: After completing all wiring steps, double-check all connections for any reversals or loose connections.
- Reattach Port Cover: Once verified, reattach the bottom cover of the inverter using the provided screws.
6. Operation
To power on the inverter, flip the boat-shaped switch located at the bottom of the unit to the 'ON' position. Closely monitor the indicator lights on the LCD screen. A flashing "AC/INV" indicator light signifies that the inverter is functioning correctly. Next, close the circuit breakers at both the PV input and AC input terminals. Lastly, close the circuit breaker at the AC output terminal. If both indicator lights continue to flash normally and the fault indicator light remains inactive, it indicates that the inverter has successfully entered its normal operating state.
7. Specifications

| Model | POW-LVM3K-24V | POW-LVM5K-48V |
|---|---|---|
| AC Mode | ||
| Rated input voltage | 110/120Vac | |
| Input voltage range | (90Vac-140Vac) | |
| Frequency | 50Hz/ 60Hz (auto-sensing) | 50Hz/ 60Hz (auto-sensing) |
| Overload/short-circuit protection | Circuit breaker | |
| Efficiency | >95% | |
| Maximum bypass overload current | 40A | 63A |
| Inverting Mode | ||
| Output voltage waveform | Pure sine wave | |
| Rated output power (VA) | 3000 | 5000 |
| Rated output power (W) | 3000 | 5000 |
| Rated output voltage (Vac) | 120Vac | 120Vac |
| Maximum Efficiency | >92% | >90% |
| Peak power | 6000VA | 10000VA |
| Loaded motor capability | 2HP | 4HP |
| Rated battery input voltage | 24V (Minimum starting voltage 22V) | 48V (minimum start voltage 44V) |
| Power saving mode | Load ≤50W | |
| AC Charging | ||
| Battery type | Lead acid or lithium battery | |
| Maximum charge current (can be set) | 0-40A | |
| Charge voltage range | 20–33Vdc | 40-60Vdc |
| Breaker specification | 40A | 63A |
| Solar Charging | ||
| Maximum PV open-circuit voltage | 450Vdc | 500Vdc |
| PV operating voltage range | 120~450Vdc | 120-500Vdc |
| Battery voltage range | 20~33Vdc | 40-60Vdc |
| Maximum input power | 4000W | 5500W |
| Charge current range of solar energy (settable) | 0-80A | |
| Authentication Specification | ||
| EMC authentication grade | EN61000 | |
| Noise | ≤60dB | |
| Communication interface | USB/RS485 (WiFi/GPRS)/dry node control | |
| Dimension (L*W*D) | 378mm*280mm*103mm | 426mm*322mm*126mm |
| Weight (kg) | 8 | 13 |
8. User Tips
- **Cable Sizing:** Always ensure that the cable AWG and circuit breaker specifications are correctly matched to the maximum current the cables will bear, as detailed in the instruction manual. This is crucial for safety and optimal performance.
- **Clearance for Cooling:** Maintain adequate clearance (20cm on sides, 50cm top/bottom) around the inverter to ensure proper air circulation and prevent overheating.
- **Grounding:** Always properly ground the inverter. Keep the grounding point as close as possible to the inverter for maximum effectiveness.
- **Color-Coded Wiring:** Use distinct colors for positive, negative, live, neutral, and ground wires to minimize wiring errors and enhance safety during installation and future maintenance.
9. Troubleshooting
If the inverter does not operate as expected after installation, check the following:
- Indicator Lights: Observe the AC/INV, CHARGE, and FAULT indicator lights on the LCD screen. A flashing AC/INV light indicates normal operation. If the FAULT light is on, consult the full user manual for specific error codes and solutions.
- Connections: Verify all battery, PV, AC input, AC output, and grounding connections are secure and correctly polarized. Loose or incorrect connections are common causes of issues.
- Circuit Breakers: Ensure all associated circuit breakers (DC and AC) are in the 'ON' position and have not tripped.
- Battery Voltage: Check the battery voltage to ensure it is within the specified operating range for your inverter model (24V or 48V).
- PV Input: Confirm that the solar panels are receiving adequate sunlight and that the PV operating voltage is within the inverter's acceptable range.
For persistent issues, refer to the complete user manual or contact PowMr customer support.
10. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your PowMr Hybrid Solar Inverter:
- Cleanliness: Keep the inverter clean and free from dust and debris. Ensure cooling fans are not obstructed.
- Connections: Periodically check all electrical connections for tightness and signs of corrosion.
- Environment: Ensure the installation environment remains dry, well-ventilated, and within the recommended temperature range.
- Battery Health: Monitor battery health and charge levels. Follow battery manufacturer guidelines for maintenance.
- Firmware Updates: Check the manufacturer's website for any available firmware updates for your inverter model.
11. Warranty and Support
This product comes with a warranty as detailed in the included Warranty Card. Please retain your proof of purchase for warranty claims. For technical support, troubleshooting assistance, or warranty inquiries, please contact PowMr customer service through their official channels. Refer to the Warranty Card for specific terms and conditions.