HICOMDATA 2.5GbE Managed Switch User Manual
Model: HK-S207CW-91TSM
1. Introduction
This manual provides comprehensive instructions for the installation, configuration, operation, and maintenance of your HICOMDATA 2.5GbE Managed Switch. It is intended for network administrators and users familiar with basic networking concepts.
The HICOMDATA 2.5GbE Managed Switch is a high-performance L2-management Ethernet switch designed for home labs and small to medium-sized networks. It features 8 RJ45 ports supporting 10M/100M/1G/2.5G adaptive speeds and 1 SFP+ slot supporting 1G/2.5G/10Gbps adaptive speeds, offering flexible and high-speed connectivity.
Video: HICOMDATA 2.5GbE Managed Switch Product Overview. This video demonstrates the switch in various environments, highlighting its compact design and connectivity options.
2. Package Contents
Please verify that all items are present and in good condition upon opening the package. If any items are missing or damaged, please contact your vendor.
- 1 x HICOMDATA 2.5GbE Managed Switch (Model: HK-S207CW-91TSM)
- 1 x Power Adapter (DC 12V 1A)
- 1 x User Manual (this document)
- 1 x Certificate
3. Setup
3.1 Physical Installation
- **Placement**: Place the switch on a stable, flat surface. Ensure adequate ventilation around the device. The fanless design and heat dissipation holes allow for quiet operation and efficient cooling. The switch is designed to operate in environments between 0°C and 40°C.
- **Power Connection**: Connect the provided DC 12V 1A power adapter to the DC 12V port on the rear of the switch. Plug the adapter into a standard power outlet.
- **Network Connections**: Connect your network devices (e.g., computers, routers, NAS servers, WiFi 6 APs) to the 8 RJ45 ports on the front panel. These ports support 10M/100M/1G/2.5G adaptive speeds.
- **Uplink Connection**: For high-speed uplink to your core network or server, insert a compatible SFP+ module (1G/2.5G/10Gbps adaptive) into the 10G SFP+ slot on the front panel and connect it to your fiber optic network.
- **Grounding (Optional)**: If required by your installation environment, connect a grounding wire to the grounding screws on the rear panel of the switch.
Image: The switch connected to various high-performance 2.5G devices such as NAS servers, WiFi 6 APs, AC Managers, WiFi 6 Routers, and computers, demonstrating its applicability.
Image: Port Description diagram showing the front panel with 8x 2.5Gbps RJ45 Ports and 1x 10G SFP+ Optical Port, and the rear panel with Grounding screws and DC12V1A Power Supply.
3.2 Initial Web Management Access
- **Connect PC**: Connect your management PC directly to any of the switch's RJ45 ports using an Ethernet cable.
- **Configure PC IP**: Set your PC's IP address to be in the same network segment as the switch, but with a different IP address. For example, if the switch's default IP is
192.168.2.1, set your PC's IP to192.168.2.X(where1 < X ≤ 254). The subnet mask should be255.255.255.0. - **Open Web Browser**: Launch a web browser (e.g., Internet Explorer 9.0+, Google Chrome 23.0+, Mozilla Firefox 20.0+).
- **Access Switch**: In the browser's address bar, type the default IP address of the switch:
http://192.168.2.1and press Enter. - **Login**: A login window will appear. Enter the default username
adminand passwordadmin. Click "Log in" to access the switch's web management interface.
Image: Screenshots of the Web Management Login interface, showing the login page and various configuration screens for system information, port VLAN, and port settings.
4. Operation
The web management interface provides various menus for configuring and monitoring the switch. The main menu items are System, Configuration, Security, Monitoring, and Tools.
4.1 System Settings
- **Information**: Displays device model, MAC address, IP address, netmask, gateway, firmware version, firmware date, and hardware version.
- **IP Setting**: Allows you to change the management IP address of the switch.
- **User Account**: Enables modification of the default username and password for web access.
- **Port Setting**: Provides options to query and configure individual Ethernet ports, including their state (enable/disable), speed/duplex settings (e.g., 10M/Half, 2500M/Full), and flow control.
4.2 VLAN Configuration
VLANs (Virtual Local Area Networks) segment a physical LAN into logical broadcast domains, enhancing network efficiency and security.
- **802.1Q VLAN**: Configure and manage VLANs. You can create VLANs with IDs ranging from 1 to 4094. Note that VLAN 1 is the default system VLAN and cannot be deleted.
- **802.1Q VID**: Set the Port VLAN ID (PVID) and accepted frame type for each port.
Image: A diagram illustrating 802.1Q VLANs, showing how a network can be segmented into VLAN A and VLAN B across multiple switches and devices to prevent network storms.
4.3 Quality of Service (QoS)
QoS allows you to prioritize network traffic, ensuring critical applications receive sufficient bandwidth and low latency.
- **Port to Queue**: Assign data frames from specific ports to different queues (1-8) based on their priority.
- **Queue Weight**: Configure the scheduling algorithm for queues. Options include Strict Priority (SP) or Weighted Round Robin (WRR) with configurable weights (1-15).
4.4 Loop Management
The switch provides mechanisms to detect and prevent network loops, which can cause network instability.
- **Loop Detection/Prevention**: The device sends loop detection packets to identify loops. If a loop is detected, the corresponding port LED blinks, and the loop can be blocked if loop avoidance is enabled.
- **STP (Spanning Tree Protocol)**: The switch supports RSTP (Rapid Spanning Tree Protocol) to eliminate physical loops in the data link layer, discover and generate an optimal tree topology, and recover from topology failures. Configure global STP settings and per-port parameters like Path Cost, Priority, P2P, and Edge.
4.5 Trunk Group Setting (Link Aggregation)
Link Aggregation (LAG) bundles multiple physical Ethernet interfaces into a single logical interface to increase bandwidth and reliability.
- **Static Mode**: Manually configure an Eth Trunk by adding member interfaces. This mode is suitable when connected devices do not support LACP.
- **LACP Mode**: Dynamically aggregates and disaggregates links based on IEEE 802.3ad. LACP exchanges information with opposite network devices to form trunk groups, providing redundant backup and load sharing.
4.6 Port-based Mirroring
Port Mirroring copies traffic from a specified source port to a destination port, allowing network administrators to monitor network traffic for analysis and troubleshooting.
4.7 Port Isolation
Port Isolation prevents direct communication between specified ports, even if they are in the same VLAN. This helps to contain broadcast, multicast, and unicast floods.
4.8 Bandwidth Control
This feature allows you to set rate limits on both ingress (incoming) and egress (outgoing) traffic for each port. For ports 1-8, the range is 0 to 25000000 Kbit/s, and for port 9 (SFP+), it's 0 to 10000000 Kbit/s.
4.9 Jumbo Frame
Configure the Maximum Transmission Unit (MTU) for ports, supporting up to 16383 bytes for efficient transmission of large data packets.
4.10 MAC Address Management
- **MAC Search**: View dynamically learned MAC address entries in the switch's forwarding table.
- **Static MAC**: Manually configure static MAC address entries, which do not age out.
- **MAC Constraint**: Limit the number of MAC addresses that can be learned on a specific port.
4.11 Storm Control
This feature prevents network storms caused by excessive broadcast, unknown multicast, or unknown unicast traffic. You can configure thresholds to suppress these types of packets.
4.12 Energy Efficient Ethernet (EEE)
Configure the Energy Efficient Ethernet function to reduce power consumption during periods of low network activity.
5. Maintenance
5.1 Monitoring
- **Port Statistics**: View real-time statistics for each port, including link status, transmitted good packets (TxGoodPkt), transmitted bad packets (TxBadPkt), received good packets (RxGoodPkt), and received bad packets (RxBadPkt).
5.2 Tools
- **Firmware Upgrade**: Allows you to update the switch's firmware. Ensure a stable power supply during the upgrade process and do not power off the device until the upgrade is complete.
- **Configuration Backup**: Backup the current switch configuration to your local machine or restore a previously saved configuration.
- **Reset**: Restore the switch to its factory default settings. This will erase all custom configurations.
- **Save**: Save the current running configuration to the switch's non-volatile memory. This is crucial to retain your settings after a reboot.
- **Reboot**: Restart the switch.
- **Logout**: Exit the web management interface.
6. Troubleshooting
This section provides guidance for common issues you might encounter.
- **Cannot Access Web Interface**:
- Ensure your PC's IP address is in the same subnet as the switch (e.g., 192.168.2.x for default 192.168.2.1).
- Verify the Ethernet cable connection between your PC and the switch.
- Confirm the switch is powered on.
- Try clearing your browser's cache or using a different browser.
- Use the default credentials (admin/admin) for initial login.
- **Network Connectivity Issues**:
- Check the link status LEDs on the switch ports.
- Verify cable integrity and ensure they are properly connected.
- Review port settings (Speed/Duplex) to ensure they match connected devices.
- If using VLANs, ensure devices are in the correct VLANs and inter-VLAN routing is configured if necessary.
- **Network Performance Degradation**:
- Check for network loops using the Loop Detection feature.
- Monitor port statistics for high error rates (TxBadPkt, RxBadPkt).
- Review Storm Control settings to prevent excessive broadcast/multicast traffic.
- Consider configuring QoS to prioritize critical traffic.
- **Configuration Errors**:
- Improper operations can lead to data loss or equipment damage. Always exercise caution when making changes.
- If a configuration change causes issues, consider restoring a previous configuration backup or performing a factory reset.
7. Specifications
Image: Front view of the 8-Port 2.5G Managed Switch with 1*10G Uplink, showing its dimensions (168mm x 94mm x 32mm) and key specifications like port rates, bandwidth, and input power.
| Feature | Description |
|---|---|
| Product Name | 9-Port 10G Uplink 2.5G Web Managed Ethernet Switch |
| Model | HK-S207CW-91TSM |
| Port Definition | 8*10/100/1000/2500Mbps RJ45 Ports, 1*1000M/2.5G/10Gbps SFP+ Slot |
| Supply Voltage | Adapter input voltage: AC 100-240 V, Switch input voltage: DC 12V 1A |
| Performance | Backplane Bandwidth: 60Gbps (non-blocking) Packet Forwarding Rate: 44.64Mpps MAC Address Table: 4K Jumbo Frame: 12KBytes Package Cache: 8Mbit |
| Network Protocol | IEEE802.3, IEEE802.3ab, IEEE802.3ae, IEEE802.3U, IEEE802.3z, IEEE802.3x, IEEE802.3bz |
| Network Medium | 10BASE-T: UTP category 5e, 5 cable (≤100m) 100BASE-TX: UTP category 5e, 5 cable (≤100m) 1000BASE-X: UTP category 5e, 5 cable (≤100m) 2.5GBASE-X: UTP category 5e, 5 cable (≤100m) 10GBASE-X: MMF, SMF 10GBASE-SR: OM1/OM2/OM3 or above MMF (2m~300m) 10GBASE-LR: IEC's B1.1 and B1.3 SMF (2m~10000m) |
| Work Environment | Operating Temperature: 0℃ ~ 40℃ Storage Temperature: -40℃ ~ 70℃ Operating Humidity: 10% ~ 90% non-condensing Storage Humidity: 5% ~ 90% non-condensing |
| Structure Size | Dimensions (L*W*H): 168mm * 94mm * 32mm |
| Function | LACP, QoS, VLAN Support |
| Certification | CE, FCC, RoHS, WEEE |
8. Warranty and Support
The HICOMDATA 2.5GbE Managed Switch is designed and manufactured to high-quality standards. It complies with various international certifications including CE, FCC, RoHS, and WEEE.
For detailed warranty information, technical support, or to report any issues, please refer to the official HICOMDATA website or contact your authorized reseller. You can also find the full user manual in PDF format for download: User Manual (PDF).
9. User Tips
- **Initial Login**: Always ensure your PC's IP address is configured within the same subnet as the switch (e.g., 192.168.2.x) for the first web management login.
- **VLAN 1**: Remember that VLAN 1 is a system-reserved default VLAN and cannot be deleted. Plan your custom VLAN IDs accordingly.
- **Eth-Trunk Configuration**: Before making changes to an Eth-Trunk's work pattern, ensure that no member interfaces are actively transmitting or receiving data to prevent configuration failures.
- **Firmware Upgrade**: During a firmware upgrade, maintain a stable power supply and avoid interrupting the process. Wait for the switch to fully complete the upgrade and reboot.
- **Configuration Management**: Regularly save your switch configuration after making changes and create backups to easily restore your settings if needed.
- **Quiet Operation**: The fanless design ensures quiet operation, making it suitable for environments where noise is a concern, such as home labs or offices.
- **Lightning Protection**: The switch features 6KV lightning protection, enhancing system security and stable operation in environments prone to electrical surges.