SONGGER VMV1S-2

Contents

SONGGER VMV1S-2 Smart Vacuum Gauge

Digital Pressure Meter User Manual

1. Introduction

The SONGGER VMV1S-2 Smart Vacuum Gauge is a high-precision digital instrument designed for accurate vacuum measurement in various professional applications. It features a reliable Pirani sensor, Bluetooth connectivity for remote monitoring via the HiVALUE App, and integrated audible and visual alarms for leak detection. This manual provides essential information for the safe and effective use of your device.

VMV1S-2 Smart Vacuum Gauge with accessories and key features listed
Figure 1: VMV1S-2 Smart Vacuum Gauge and included components.

2. Package Contents

  • VMV1S-2 Smart Vacuum Gauge
  • USB Charging Cable
  • Protective Carrying Case
  • User Manual (this document and a PDF version is available)
VMV1S-2 Smart Vacuum Gauge with its carrying case and USB charging cable
Figure 2: VMV1S-2 Smart Vacuum Gauge with accessories.

3. Specifications

Parameter Specification
ModelVMV1S-2
Measuring Range0.1–3333.3 Pa
Resolution0.01 Pa (0.1–10 Pa), 0.1 Pa (10–3333 Pa)
Accuracy±25% (0.1–6.7 Pa)
Max Overpressure3.4 bar
Sensor TypePirani Sensor
Display UnitsPa, mBar, mmHg, microns
Power Supply2000 mAh lithium battery (rechargeable)
Operating Temperature0–45°C
Weight175g
Bluetooth FunctionHiVALUE App for real-time data monitoring
Table of technical specifications for the VMV1S-2
Figure 3: Detailed technical specifications.

4. Setup

  1. Charge the Battery: Before initial use, ensure the built-in 2000 mAh lithium battery is adequately charged using the provided USB cable and a standard USB power source.
  2. Install HiVALUE App: If remote monitoring via Bluetooth is desired, download and install the HiVALUE App on your compatible mobile device (Android or iOS).
  3. Connect the Gauge: Securely connect the VMV1S-2 vacuum gauge to your vacuum system or refrigerant line. Ensure connections are tight to prevent leaks.
VMV1S-2 Smart Vacuum Gauge highlighting Bluetooth, Pirani Sensor, Vacuum Timing, and Overpressure Protection
Figure 4: Key features for setup and operation.

5. Operating Instructions

  1. Power On: Press the power button to turn on the device. The backlit digital display will illuminate.
  2. Select Pressure Unit: Use the 'SET' button or arrow keys to cycle through and select your desired pressure unit (Pa, mBar, mmHg, microns).
  3. Start Vacuum Process: Initiate your vacuum process. The gauge will begin displaying real-time vacuum readings.
  4. Monitor Readings: Observe the vacuum level, timing data, and leakage status directly on the gauge's display. For remote monitoring, open the HiVALUE App on your mobile device and connect via Bluetooth.
  5. Leak Detection: If a vacuum leak is detected or preset alarm conditions are reached, the device will activate an audible alarm (beeping) and the backlight will flash rapidly.
  6. Power Off: Press and hold the power button to turn off the device after use.
VMV1S-2 Smart Vacuum Gauge showing Large Backlit Digital Display, Beep Alarm, and High-Precision Vacuum Sensor
Figure 5: Display and alarm features.

Video 1: SONGGER company and product manufacturing overview.

6. Maintenance

  • Storage: Store the device in a dry, clean, and well-ventilated environment when not in use. Use the protective carrying case to prevent damage.
  • Cleaning: Clean the exterior of the gauge with a soft, dry cloth. Do not use solvents, abrasive cleaners, or harsh chemicals, as these can damage the device.
  • Battery Care: For long-term storage, recharge the battery at least once every three months to maintain optimal battery performance and lifespan.

7. Troubleshooting

  • No Display/Device Not Turning On: Ensure the battery is sufficiently charged. Connect the USB charging cable and allow it to charge for at least 30 minutes before attempting to power on again.
  • Inaccurate Readings: Verify that the gauge is securely connected to the vacuum system and that there are no external leaks affecting the measurement. Ensure the sensor port is clean and free from debris.
  • Bluetooth Connectivity Issues: Make sure Bluetooth is enabled on your mobile device and the HiVALUE App is updated to the latest version. Ensure the gauge is within range of your mobile device.
  • Leak Alarm Activation: If the audible alarm and flashing backlight activate, it indicates a detected vacuum leak or that a preset alarm threshold has been met. Inspect your vacuum system for leaks.

8. User Tips

  • For HVAC vacuum testing, users have found the readings to be stable and easy to read, contributing to efficient work.
  • Regularly check for firmware updates for the HiVALUE App to ensure optimal performance and new features.
  • Always ensure the gauge is at the same ambient temperature as the system being measured for the most accurate readings.

9. Safety Precautions

  • Use the instrument only within the specified measuring range and operating temperature (0–45°C).
  • Do not exceed the maximum overpressure limit of 3.4 bar. Connecting to systems exceeding this pressure can cause injury or equipment damage.
  • Avoid mechanical shock, strong vibration, and exposure to corrosive or flammable gases.
  • Recharge the battery using standard USB power sources only. Do not use unapproved chargers.
  • This product is intended for low-pressure vacuum measurement applications only.
  • Keep out of reach of children.
  • Dispose of the product in accordance with local regulations for electronic waste (WEEE directives where applicable).

10. Warranty and Support

For warranty information, please refer to your purchase documentation or contact your seller directly. For technical support or inquiries, please use the contact information below:

  • WhatsApp: +86-13311678550
  • Email: miazhao008@gmail.com
Contact information for technical support
Figure 6: Contact details for support.

© 2024 SONGGER. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.