Estardyn HW-465 Series UPS Power Supply Module

Contents

Estardyn Type-C 15W 3A Fast Charge UPS Power Supply / 18650 Lithium Battery Charger Module

Model: HW-465 Series (5V, 9V, 12V Variants)

1. Introduction

This manual provides detailed instructions for the safe and efficient use of your Estardyn Type-C 15W 3A Fast Charge UPS Power Supply and 18650 Lithium Battery Charger Module. This versatile module acts as a DC-DC step-up booster converter, offering uninterrupted power supply (UPS) functionality for various applications. It is available in 5V, 9V, and 12V output versions.

Estardyn UPS Power Supply Module with 18650 battery holder
Overview of the Estardyn UPS Power Supply Module and 18650 battery holder.

2. Specifications

ParameterValue
Input VoltageDC5V or USB Type-C
Output Voltage (HW-465A)5V / 3A
Output Voltage (HW-465B)9V / 1.6A
Output Voltage (HW-465C)12V / 1.2A
Rated Maximum Output Power15W
Charging Cut-off Voltage4.2V ± 1%
Battery Over-discharge Protection Voltage2.5V
Static Power ConsumptionApproximately 10mA
TypeVoltage Regulator
Is CustomizedYes
High-concerned chemicalNone

3. Product Features

  • Automatic charging during incoming calls, uninterrupted switching during power outages, and startup.
  • Onboard LED indicators for charging, full charge, and output status.
  • Integrated lithium battery protection functions including overcharge, over-discharge, overcurrent, and over-temperature.
  • Available in three output voltage versions: 5V, 9V, and 12V.
  • Battery holder supports parallel connection of multiple 18650 cells for stable and sufficient charging and discharging.
  • Flexible power input via USB Type-C or DC5V interface.

4. Safety Precautions

Please read and adhere to the following safety guidelines to prevent damage to the module or connected devices, and to ensure safe operation:

  1. Correct Wiring: Always pay close attention to the wiring diagram and ensure all connections are made correctly. Incorrect wiring can cause damage to the module or connected components.
  2. Battery Polarity: Ensure the positive (+) and negative (-) terminals of the 18650 lithium battery are inserted into the battery holder with the correct polarity. Reversing polarity will damage the module.
  3. Heat Dissipation: If the module is charging and discharging simultaneously, or if it generates excessive heat during operation, ensure adequate heat dissipation. This may involve providing airflow or using a heatsink if necessary.
  4. Protection Activation: If the module stops outputting due to incorrect wiring or accidental contact, troubleshoot the issue. After resolving the problem, connect a USB 5V power supply to the input to reactivate the output.
Bottom view of the 18650 battery holder showing polarity markings
Ensure correct battery polarity as indicated on the holder.

5. Setup and Installation

Follow these steps to set up your UPS power supply module:

  1. Install Battery: Insert one or more 18650 lithium batteries into the battery holder, ensuring correct polarity. The battery holder can accommodate multiple batteries connected in parallel.
  2. Connect Input Power: Connect a DC5V power source or a USB Type-C cable from a compatible charger to the module's input interface.
  3. Connect Load: Connect your load device (e.g., router, switch, infrared alarm) to the UPS+ and UPS- terminals on the module. Ensure the load's voltage requirements match the module's output version (5V, 9V, or 12V).
Top view of the UPS module with input, output, and battery connection points labeled
Detailed view of the module's connection points.
Wiring diagram for connecting battery, 5V input, and load to the UPS module
Wiring diagram illustrating battery, input power, and load connections.

6. Operation

Once the module is set up, its operation is largely automatic:

  • Initial Power-On: After connecting the battery, the onboard red output indicator light will illuminate.
  • Charging: When a phone charger and data cable are plugged into the Type-C interface (or DC5V input), the battery charging indicator light will show the charging status (charging or full).
  • UPS Functionality: When the input power supply is active, the module simultaneously charges the battery and powers the load (ensure input power provides 3A or more). If the external power supply is disconnected, the module automatically switches to battery power without interruption.
  • Protection Modes:
    • If the battery voltage drops below 2.5V, the output voltage protection will activate, reducing the output.
    • In cases of overheating or overload, the output red light will flash, indicating protection is active.

7. Maintenance

To ensure the longevity and optimal performance of your Estardyn UPS module:

  • Keep the module clean and free from dust and debris.
  • Avoid exposing the module to extreme temperatures or humidity.
  • Regularly check battery connections for secure contact.
  • Ensure proper ventilation, especially when operating under heavy load or in warm environments.

8. Troubleshooting

If you encounter issues with your module, refer to the following common problems and solutions:

ProblemPossible Cause / Solution
No output after setup
  • Incorrect wiring: Double-check all connections against the wiring diagram.
  • Incorrect battery polarity: Ensure 18650 batteries are inserted correctly.
  • Protection activated: If the module entered a protection state (e.g., due to incorrect wiring or accidental short), disconnect and reconnect a USB 5V power supply to reactivate the output.
Module is overheating
  • Simultaneous charging and discharging under heavy load: Ensure adequate heat dissipation (e.g., improved airflow, heatsink).
  • Overload: Reduce the load connected to the module.
Output red light flashingIndicates overheating or overload protection is active. Reduce load or improve heat dissipation.
Battery not charging
  • Input power issue: Verify the 5V or Type-C input power source is functional and providing sufficient current.
  • Battery issue: Check the 18650 battery for damage or proper insertion.

9. User Tips

  • For optimal performance and extended battery life, use high-quality 18650 lithium batteries.
  • When using multiple 18650 batteries, ensure they are of the same type and charge level for balanced operation.
  • Consider the power requirements of your load device and select the appropriate output voltage version (5V, 9V, or 12V) of the module.
  • Always test connections with a multimeter before applying full power to sensitive equipment.

10. Warranty and Support

For any issues not covered in this manual or for further assistance, please contact Estardyn customer support. Keep your purchase receipt for warranty claims.