1. Introduction
The ZOYI ZT-81 is a battery-powered, true-RMS, auto-ranging digital multimeter featuring a 4000-count LCD display with backlight. It is designed for precise and rapid response measurements, making it suitable for electricians and repair tasks.

Figure 1: ZOYI ZT-81 Mini Digital Multimeter
2. Safety Information
WARNING: To avoid possible electrical shock, fire, or personal injury, please read all safety information carefully before using the product.
- Do NOT exceed the "maximum value" indicated in the Specifications.
- Examine the connection of the test leads and the insulation of the product before measuring voltage higher than 36V DC or 25V AC.
- Disconnect the test leads from the circuit before changing the mode.
- Misuse of mode or range can lead to hazards. "OL" will be shown on the display when the input is out of range.
- Do NOT input voltage exceeding 36V DC or 25V AC when measuring current.
Safety Symbols:
- ⚠ Hazardous Voltage
- ⚡ Earth
- ⚠ Double Insulated
- ⚡ Low Battery
- ⚠ Risk of Danger. Check the User Manual.
3. Setup
3.1. Battery Installation
When the low battery symbol (⚡) is shown on the display, batteries shall be replaced:
- Loosen the screw and remove the battery cover.
- Replace the used batteries with new batteries of the same type (1.5V AAA Battery * 2).
- Place the battery cover back and fasten the screw.
3.2. Probe Connection
The multimeter has three input terminals:
- 10A current input terminal: For measuring high currents.
- VmAμA Hz Input terminal: For voltage, resistance, capacitance, frequency, current (mA/μA), continuity, diode, and duty cycle measurements.
- COM: Common terminal for all measurements.
Always ensure correct probe connection for the desired measurement to prevent damage to the device or personal injury.

Figure 2: Multimeter Layout and Terminal Instructions
4. Operating Instructions
4.1. Basic Functions Overview
The ZT-81 offers a range of functionalities for various electrical measurements:

Figure 3: Basic Functions of ZOYI ZT-81
- Auto Identification: Automatically recognizes AC/DC voltage, resistance, and continuity.
- Overload Protection: Ensures safety during measurements.
- Backlight Display: For clear readings in dimly lit environments.
- Auto-Off: Conserves battery life.
- AC/DC Voltage (V): Measures alternating and direct current voltage.
- AC/DC Current (A): Measures alternating and direct current.
- Resistance (Ω): Measures electrical resistance.
- Low Battery Indicator: Alerts when battery replacement is needed.
- Capacitance: Measures electrical capacitance.
- Diode & Continuity: Tests diodes and circuit continuity.
- Frequency (Hz): Measures electrical frequency.
- 3/S Sampling Rate: Provides rapid measurement updates.
4.2. Smart Measurement Mode (AUTO)
The ZT-81 features an intelligent AUTO mode that automatically identifies the measurement type (AC/DC voltage, resistance, continuity) without manual range selection. When the screen displays "AUTO," the device is in Smart Mode.

Figure 4: Auto-Identification Feature
4.3. Button Functions
- HOLD/✪ (Backlight Key): Press once to hold the current reading (display shows "HOLD"). Press again to cancel. Long-press for more than 2 seconds to turn on/off the backlight.
- SEL/REL (Conversion Key): Toggles between AC/DC, Diode/Capacitance/Continuity, or °C/°F modes.
- Rotary Switch: Used to change the measurement mode or range.
4.4. Specific Measurement Procedures
Before any measurement, ensure the test leads are correctly connected and the rotary switch is set to the appropriate mode.
4.4.1. Measuring AC/DC Voltage
- Connect the black test lead to the COM Terminal and the red test lead to the VmAμA Hz Terminal.
- Turn the rotary switch to the desired voltage range (e.g., 400mV~600V range) or AUTO mode.
- Touch the probes to the correct test points of the circuit to measure the voltage.
- Read the measured voltage on the display.

Figure 5: AC Voltage Measurement

Figure 6: DC Voltage Measurement
4.4.2. Measuring Resistance
- Connect the black test lead to the COM Terminal and the red test lead to the VmAμA Hz Terminal.
- Turn the rotary switch to the desired resistance range (e.g., 400Ω~40MΩ) or AUTO mode. The display will show "OL" if out of range.
- Touch the probes to the desired test points of the circuit to measure the resistance.
- Read the measured resistance on the display.
Caution:
- Disconnect circuit power and discharge all capacitors before testing resistance.
- Do not input voltage at the Resistance Mode.

Figure 7: Resistance Measurement
4.4.3. Measuring Continuity
- Connect the black test lead to the COM Terminal and the red test lead to the VmAμA Hz Terminal.
- Turn the rotary switch to the continuity mode or AUTO mode.
- Touch the probes to the desired test points of the circuit.
- The built-in beeper will sound when the resistance is lower than 50Ω, indicating a short circuit.
Caution: Do not input voltage at the Continuity Mode.

Figure 8: Continuity Measurement
4.4.4. Measuring Diode
- Connect the black test lead to the COM Terminal and the red test lead to the VmAμA Hz Terminal.
- Turn the rotary switch to the diode Mode.
- Connect the red probe to the anode side and the black probe to the cathode side of the diode being tested.
- Read the forward bias voltage value on the display. If the polarity is reversed or the diode is broken, the display shows "OL".
Caution: Do not input voltage at the Diode Mode.
4.4.5. Measuring Capacitance
- Connect the black test lead to the COM Terminal and the red test lead to the VmAμA Hz Terminal.
- Turn the rotary switch to the capacitance mode.
- Connect the red probe to the anode side and the black probe to the cathode side of the capacitor being tested.
- Read the measured capacitance value on the display once the reading is stabilized.
Caution: Disconnect circuit power and discharge all capacitors before testing capacitance.

Figure 9: Capacitance Measurement
4.4.6. Measuring Frequency
- Connect the black test lead to the COM Terminal and the red test lead to the VmAμA Hz Terminal.
- Turn the rotary switch to the Frequency Mode.
- Touch the probes to the desired test points of the circuit.
- Read the measured frequency value on the display.
Caution: The Frequency Mode only applies to measure high frequency with low voltage.

Figure 10: Frequency Measurement
4.4.7. Measuring NCV (Non-Contact Voltage)
- Turn the rotary switch to NCV Mode.
- Hold the product and move it around. The built-in beeper will sound when the inner sensor detects AC voltage nearby. The stronger the voltage, the quicker the beeper sounds.
- Place the red probe into the VmAμA Hz terminal, then use the black probe to touch the Live line and Neutral line of the Main supply. You can judge the L-line or N-line by the beeps. If you can hear strong beeps, this is the L-line, or it's a N-line.
4.5. Auto Power Off
- The product automatically powers off after 15 minutes of inactivity.
- The built-in beeper beeps 5 times 1 minute before power off.
- To restart the product, press the SELECT button.
- To disable the Auto Power Off function, hold down the SELECT button when turning on the product. You will hear five beeps if you have successfully disabled the function.
Video 1: ZOYI ZT-81 Multimeter demonstration of intelligent measurement and accuracy.
5. Specifications
The following table details the electrical and general specifications of the ZOYI ZT-81 Multimeter.

Figure 11: Electrical Specifications
| Function | Range | Resolution | Accuracy | MAX. Value | Other |
|---|---|---|---|---|---|
| DC Voltage (V) | 4.000V/40.00V/400.0V | 0.001V/0.01V/0.1V | ±(0.5%+3) | 600V | |
| 600V | 1V | ||||
| DC Voltage (mV) | 400.0mV | 0.1mV | ±(0.5%+3) | 400.0mV | |
| AC Voltage (V) | 4.000V/40.00V/400.0V | 0.001V/0.01V/0.1V | ±(1.0%+3) | 600V | |
| 600V | 1V | ||||
| AC Voltage (mV) | 400.0mV | 0.1mV | ±(1.0%+3) | 400.0mV | |
| DC Current (A) | 10.00A | 0.01A | ±(1.2%+3) | 10.00A | |
| DC Current (mA) | 40.00mA/400.0mA | 0.01mA/0.1mA | ±(1.2%+3) | 400.0mA | MAX. Current: 10A (no more than 15 seconds) |
| DC Current (μA) | 400.0μA | 0.1μA | ±(1.2%+3) | 400.0μA | |
| AC Current (A) | 10.00A | 0.01A | ±(1.5%+3) | 10.00A | Frequency Response(AC): 40Hz-1kHz |
| AC Current (mA) | 40.00mA/400.0mA | 0.01mA/0.1mA | ±(1.5%+3) | 400.0mA | |
| AC Current (μA) | 400.0μA | 0.1μA | ±(1.5%+3) | 400.0μA | |
| Resistance | 400.0Ω/4.000kΩ/40.00kΩ/400.0kΩ/4.000MΩ | 0.1Ω/0.001kΩ/0.01kΩ/0.1kΩ/0.001MΩ | ±(0.5%+3) | 40.00MΩ | No Voltage input at this mode |
| 40.00MΩ | 0.01MΩ | ±(1.5%+3) | |||
| Capacitance | 4.000nF | 0.001nF | ±(5.0%+20) | 4.000mF | No Voltage input at this mode |
| 40.00nF/400.0nF/4.000μF/40.00μF/400.0μF | 0.01nF/0.1nF/0.001μF/0.01μF/0.1μF | ±(2.0%+5) | |||
| 4.000mF | 0.001mF | ±(5.0%+5) | |||
| Frequency | 40.00Hz/400.0Hz/4.000kHz/40.00kHz/400.0kHz | 0.01Hz/0.1Hz/0.001kHz/0.01kHz/0.1kHz | ±(0.1%+2) | 4.000MHz | |
| 4.000MHz | 0.001MHz | ||||
| Diode | V (DC forward current is 5mA, voltage is 3V) | No Voltage input at this mode | |||
| Continuity | V (no more than 50Ω) | No Voltage input at this mode |
| General Specifications | Mechanical Specifications | ||
|---|---|---|---|
| Display (LCD) | 4000 counts | Dimension | 130*65*32mm |
| Ranging | Manual | Weight | 114g/128g (w/batteries) |
| Material | ABS | Battery Type | 1.5V AAA Battery * 2 |
| Update Rate | 3 times/second | Warranty | One year |
| True RMS | ✓ | Environmental Specifications | |
| Data Hold | ✓ | Operating Temperature | 0~40°C |
| Backlight | ✓ | Operating Humidity | <75% |
| Low Battery Alert | ✓ | Storage Temperature | -20~60°C |
| Auto Power Off | ✓ | Storage Humidity | <80% |
6. Maintenance
Beyond replacing batteries and fuses, do not attempt to repair or service the product unless you are qualified to do so and have the relevant calibration, performance test, and service instructions.
- Do not operate the product around hot, wet, flammable, explosive or magnetic environments.
- Clean the product with a damp cloth and mild detergent; do not use abrasives or solvents.
- Remove the input signals before cleaning the product.
- Remove the batteries if you will not use the product for a long time to prevent possible battery leak.
- Replace fuses as above steps. Use only fuses of the same type as the original ones.
7. Troubleshooting
If your product does not function as normal, the following steps may help you. If the problem still cannot be solved, please contact your dealer.
| Problem | Possible Reason |
|---|---|
| Display Malfunction | Low battery; replace batteries |
| Symbol | Replace batteries |
| No current input | Replace fuse |
8. Warranty and Support
Customers enjoy a one-year warranty from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.
All rights reserved. Specifications are subject to change without notice.
For further assistance, you may refer to the official user manual PDF: ZOYI ZT-81 User Manual (PDF)
9. User Tips
- Always double-check your probe connections and rotary switch settings before taking any measurements to avoid damage to the multimeter or the circuit.
- Utilize the AUTO mode for general measurements to simplify operation, but switch to specific ranges for more precise control or when dealing with unknown values.
- The backlight feature is very useful in low-light conditions, but remember to turn it off when not needed to conserve battery life.
- For continuity tests, ensure the circuit is de-energized to prevent false readings or damage.
- Keep the multimeter clean and store it in a dry, safe place to prolong its lifespan.