ANENJI ANJ-HHP-II-6.2KP-WIFI

Contents

ANENJI 6.2KW Off-Grid Solar Inverter

Model: ANJ-HHP-II-6.2KP-WIFI

1. Introduction

This is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

Key Features

  • Pure Sine Wave Output: Provides stable pure sine wave output, suitable for various sensitive devices.
  • Inverter Running Without Battery: Functions normally even without a battery, providing continuous power supply.
  • Built-in MPPT Solar Controller: Maximizes the efficiency of solar panels with a 120A Maximum Power Point Tracking (MPPT) controller.
  • Configurable Settings: Input voltage range, battery charging current, and AC/Solar Charger priority are user-configurable via LCD.
  • Power Compatibility: Compatible with mains voltage or generator power.
  • Automatic Restart: Auto restart function when AC power recovers.
  • Comprehensive Protection: Includes overload, over temperature, and short circuit protection.
  • Smart Battery Charger: Designed for optimized battery performance.
  • Cold Start Function: Allows the inverter to start without AC input.
  • Parallel Operation: Supports parallel operation of up to 12 units in single-phase or three-phase systems.
  • WiFi Connectivity: Direct Plug WiFi Dongle supported for easy remote monitoring.
  • High PV Input: Max PV Input 500Vdc.
  • Durable Design: Detachable dust cover suitable for harsh environments.
  • Battery Optimization: EQ Function to optimize battery performance and extend lifecycle.

Basic System Architecture

The inverter/charger integrates into a complete system typically including a power source (Generator or Utility), PV modules (optional), the inverter itself, external battery packs, and various home appliances. This inverter can power all kinds of appliances in home or office environments, including motor-type appliances.

Diagram showing solar inverter system architecture with and without battery

Figure 1: Operation with and without battery connected, showing PV array, power grid, inverter, battery, and household appliances.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries and all appropriate sections of this manual.
  2. CAUTION: To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION: Only qualified personnel can install this device with battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to INSTALLATION section of this manual for the details.
  10. Fuse is provided as over-current protection for the battery supply.
  11. GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulation to install this inverter.
  12. NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
  13. Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.

3. Product Overview

The ANENJI 6.2KW Off-Grid Solar Inverter features a user-friendly interface and clearly labeled connection points for easy installation and operation.

Diagram of inverter showing front and bottom panel components

Figure 2: Front and bottom view of the inverter with labeled components.

Component Identification

  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function buttons
  6. Power on/off switch
  7. AC input
  8. AC output
  9. PV input
  10. Battery input
  11. RS232 communication port
  12. Parallel communication port (only for parallel model)
  13. RS485 communication port
  14. Grounding
  15. WiFi module avoidance hole (Only use WiFi module models to remove)
  16. RS485 communication line outlet
  17. Battery positive outlet hole
  18. Battery negative outlet hole

4. Installation and Setup

4.1 Unpacking and Inspection

Before installation, inspect the unit. Ensure nothing inside the package is damaged. The package should contain: The unit x 1, User manual x 1.

4.2 Preparation

Before connecting all wirings, remove the bottom cover by unscrewing two screws.

4.3 Mounting the Unit

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install at eye level for LCD display readability.
  • Ambient temperature should be between 0°C and 55°C for optimal operation.
  • Recommended installation position is vertically adhered to the wall.
  • Ensure sufficient heat dissipation and space for wiring by maintaining clearances: 20cm on sides, 50cm above and below.

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

4.4 Battery Connection

CAUTION: For safety and regulation compliance, install a separate DC over-current protector or disconnect device between battery and inverter.

WARNING! All wiring must be performed by qualified personnel. Use appropriate cable for battery connection to reduce risk of injury.

ModelMax. AmperageBattery CapacityWire SizeCable mm²Torque Value
6.2KVA137A200AH2AWG382~3 Nm

Steps: 1. Prepare positive and negative cables. 2. Connect all battery packs. 3. Insert cables into inverter connector and tighten bolts (2-3Nm). Ensure correct polarity.

4.5 AC Input/Output Connection

CAUTION!! Install a separate AC breaker (recommended 50A) between inverter and AC input source. Do NOT mis-connect input and output connectors.

WARNING! All wiring must be performed by qualified personnel. Use appropriate cable size.

ModelGaugeTorque Value
6.2KVA8 AWG1.4~1.6Nm

Steps: 1. Open DC protector/disconnector. 2. Remove 10mm insulation. 3. Insert AC input wires (Ground, Line, Neutral) and tighten. 4. Insert AC output wires (Ground, Line, Neutral) and tighten. 5. Ensure secure connections.

4.6 PV Connection

CAUTION: Install a DC circuit breaker between inverter and PV modules.

WARNING! All wiring must be performed by qualified personnel. Use appropriate cable size.

ModelTypical AmperageCable SizeTorque
6.2KVA27A10 AWG1.4~1.6 Nm

PV Module Selection: Consider max. PV array open circuit voltage (500VDC) and MPPT voltage range (60VDC~500VDC).

Steps: 1. Remove 10mm insulation. 2. Check polarity and connect positive (+) and negative (-) PV cables to the respective PV input connectors. 3. Ensure secure connections.

4.7 Parallel Installation Guide

This inverter supports parallel operation with up to 12 units in single-phase or three-phase configurations.

  • Mounting: Maintain 20cm side clearance and 50cm top/bottom clearance between units.
  • Wiring: Ensure all battery cables are of the same length. Use appropriate cable sizes for AC input/output and battery connections, scaled by the number of parallel units.
  • Communication: Use the provided parallel communication cable to link units. For battery BMS communication in parallel systems, connect one inverter via RJ45 to the Lithium battery and set its battery type to 'Li 2' in LCD program 5; other inverters should remain at default 'AGM'.

5. Operation

5.1 Power ON/OFF

Once properly installed and batteries connected, press the On/Off switch (located on the bottom of the case) to turn on the unit.

5.2 Operation and Display Panel

The front panel features three indicators, four function keys, and an LCD display.

LED IndicatorColorStatusMessage
AC / INVGreenSolid OnOutput powered by utility (Line mode)
FlashingOutput powered by battery or PV (Battery mode)
CHGGreenSolid OnBattery fully charged
FlashingBattery is charging
FAULTRedSolid OnFault occurs in inverter
FlashingWarning condition occurs in inverter
Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm selection or enter setting mode

5.3 LCD Display Icons

The LCD displays various icons indicating input source, configuration, fault information, output status, battery level, load level, and operational modes (e.g., AC input, PV input, charging, bypass, inverter circuit working, alarm disabled).

5.4 LCD Setting

Press and hold ENTER for 3 seconds to enter setting mode. Use UP/DOWN to select programs and ENTER to confirm. Key configurable settings include:

  • Output Source Priority: Solar first, Utility first, SBU (Solar-Battery-Utility), SUB (Solar-Utility-Battery).
  • Maximum Charging Current: Total charging current for solar and utility chargers.
  • AC Input Voltage Range: For appliances, UPS, or generator.
  • Power Saving Mode: Enable/disable.
  • Battery Type: AGM, Flooded, User-Defined.
  • Output Voltage & Frequency: Set desired AC output voltage and frequency.
  • Low DC Cut-off Voltage: Configurable battery discharge cut-off point.

5.5 Operating Mode Description

  • Standby Mode: Inverter is off, but can charge batteries.
  • Fault Mode: Indicates internal circuit errors or external issues (over temperature, short circuit).
  • Line Mode: Output powered by mains, also charges battery.
  • Battery Mode: Output powered by battery and/or PV.

6. Battery Equalization

Equalization reverses negative chemical effects like stratification and removes sulfate crystals, extending battery life. It's recommended to equalize batteries periodically.

  • How to Apply: Enable equalization in LCD setting program 33. Then, set equalization interval (program 37) or activate immediately (program 39).
  • When to Equalize: The controller enters Equalize stage when the set interval is reached or activated immediately.
  • Process: The controller charges the battery until it reaches the equalization voltage, then maintains this voltage until the set equalized time is reached.

7. Setting for Lithium Battery

If using lithium batteries, ensure proper connection and communication with the inverter.

  • Connection: Connect the RS485 port of the battery's BMS to the inverter's RS485 communication port.
  • Communication: The BMS communication cable delivers information (charging voltage, current, discharge cut-off) and signals to start/stop charging.
  • LCD Settings: After connecting, configure battery type (e.g., 'Li 2' for PYLON US2000 or 'User-Defined'), set max charging voltage (C.V voltage), floating charging voltage, low DC cut-off voltage, and max charging current according to the battery's BMS specifications.

8. Specifications

Detailed electrical and physical specifications for the ANENJI 6.2KW Off-Grid Solar Inverter.

General Specifications

  • Model Number: ANJ-HHP-II-6.2KP-WIFI
  • Brand Name: ANENJI
  • Capacity: 6.2KW / 6.2KVA
  • Output Current: 120A
  • Dimensions (DxWxH): 450x300x130 mm (45x30x13cm)
  • Net Weight: 9.6 kg (11kg packaged)
  • Parallel Function: Yes, up to 12 Units
  • Safety Certification: CE
  • Operating Temperature: -10°C to 55°C
  • Storage Temperature: -15°C to 60°C
  • Humidity: 5% to 95% Relative Humidity (Non-condensing)

Input & Output Specifications

  • Input Nominal Voltage: 230VAC
  • Input Acceptable Voltage Range: 170-280VAC (PC); 90-280VAC (Home Appliances)
  • Input Frequency: 50/60 Hz (Auto sensing)
  • Output Nominal Voltage: 220/230VAC ±5%
  • Output Frequency: 50/60Hz
  • Waveform: Pure Sine Wave
  • Transfer Time: 10ms (PC); 20ms (Home Appliances)
  • Peak Efficiency: 94%

Solar Charger & AC Charger Specifications

  • Solar Charger Type: MPPT
  • Max. PV Array Power: 6500W
  • Max. PV Array Open Circuit Voltage: 500VDC
  • PV Array MPPT Voltage Range: 60VDC~500VDC
  • Max. Charge Current: 120A
  • Max. Solar Input Current: 27A
  • Battery Voltage: 48VDC
  • Floating Charge Voltage: 54VDC
  • Over Charge Protection: 63VDC

For complete detailed specifications, please refer to the tables in the full PDF manual.

9. Troubleshooting

This section provides solutions for common issues encountered during operation.

ProblemExplanation / Possible CauseWhat to do
Unit shuts down automatically during startupBattery voltage is too low1. Re-charge battery. 2. Replace battery.
No response after power on1. Battery voltage is too low. 2. Battery polarity reversed.1. Check batteries/wiring. 2. Re-charge battery. 3. Replace battery.
Mains exist but unit works in battery modeInsufficient quality of AC power.1. Check AC wires. 2. Check generator. 3. Check input voltage range setting.
Fault code 07Overload error.Reduce connected load.
Fault code 02Internal temperature > 100°C.Check air flow, ambient temperature.
Fault code 03Battery is over-charged or voltage too high.Return to repair center. Check battery specs.
Fault code 13, 14, 16Over current/surge, Bus voltage low, Output voltage unbalanced.Restart unit. If error persists, return to repair center.

For a complete list of fault codes and warnings, refer to the full PDF manual.

10. User Tips

This section is omitted due to the lack of specific user review or Q&A data.

11. Warranty & Support

For warranty information and technical support, please contact your authorized dealer or the manufacturer directly. Keep your purchase receipt for warranty claims.

A detailed user manual in PDF format is available for download from the product's official support page or via the provided link: ANENJI 6.2KW Off-Grid Solar Inverter User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.