1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of JIKONG BMS accessories, including various LCD displays (2.0-inch, 3.2-inch, 4.3-inch), RS485 communication modules, and switch buttons. These accessories are designed to enhance the functionality and user experience of your JIKONG Battery Management System (BMS) by providing comprehensive monitoring and control capabilities.
The JIKONG BMS accessories are compatible with all JIKONG BMS models and are essential for real-time battery status monitoring and system interaction. Please read this manual thoroughly before installation and operation to ensure safe and optimal performance.
2. Product Features
The JIKONG BMS accessories offer a range of features to provide comprehensive battery management and user interaction:
- Wide Power Supply Range: Supports a working voltage range of 9-36V (default).
- Detailed Display Content: Shows battery total voltage, battery power, and single series voltage display.
- TTL Level Support: Supports TTL level communication with a default baud rate of 115200bps.
- Multi-language Support: Chinese, English, Thai, and Vietnamese language switchover is supported.
- Customizable Display Interface: Allows for language, logo, and interface customization.
- RS485/CAN Interface: Enables communication with other devices in the battery management system for data transmission and sharing.
- Switch Button: Used to activate and control JKBMS models, providing convenient system power management.

3. Specifications
3.1. General Parameters
| Parameter | Data |
|---|---|
| Display Category | TFT |
| Display Size | 4.3-inch (also available in 2.0-inch, 3.2-inch) |
| Resolution | 480*272 (for 4.3-inch) |
| Backlight Type/Brightness | LED/300nit |
| Viewing Angle L/R/U/D | 85°/85°/85°/85° |
3.2. Power Supply
| Parameter | Min | Max |
|---|---|---|
| Supply Voltage (with reverse protection) | 9V | 36V |
| Power Dissipation | 1.32W (12V@110mA) | |
3.3. Pin Definition (Display End Interface)
The display end interface adopts HY2.0 mm-6P vertical mount.
| Number | Name | Definition |
|---|---|---|
| 1 | K- | Activation signal negative electrode |
| 2 | K+ | Activate the positive signal |
| 3 | GND | Negative terminal (Power supply) |
| 4 | TTL-RX | UART RX, 5V |
| 5 | TTL-TX | UART TX, 5V |
| 6 | VCC | Display power output |

3.4. Operating Environment and Reliability Parameters
| Parameter | Test Environment | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Operating Temperature | At 12V, 60% humidity | -20 | - | 70 | °C |
| Storage Temperature | - | -30 | - | 80 | °C |
| Operating Humidity | 25°C | 10% | 60% | 90% | RH |
4. Setup and Installation
Proper installation is crucial for the correct functioning of your JIKONG BMS accessories. Follow these guidelines for connecting the various components.
4.1. Connecting Displays (2.0, 3.2, 4.3 inch LCD)
- Identify Cables: Each display comes with specific cables (e.g., Cable A, Cable B, Cable C for 2.5-inch display). Refer to the pin definition table (Section 3.3) for correct connections.
- Power Connection: Connect the power supply cables (VCC and GND) from the display to your BMS or a compatible power source within the 9-36V range. Ensure correct polarity to prevent damage.
- Signal Connection: Connect the TTL-RX and TTL-TX pins of the display to the corresponding UART communication ports on your JIKONG BMS.
- Mounting: Secure the display in your desired location. For bracket base displays, use the provided screws. For ring handle style displays, integrate them into the handle.



4.2. Connecting RS485 Modules
- Identify RS485 Cables: The RS485 adapter typically has Yellow (A), White (B), and Black (GND) cables.
- Connect to BMS: Connect these cables to the corresponding RS485 CAN interface on your JIKONG BMS.
- USB Connection (if applicable): For USB to RS485 adapters, connect the USB end to a computer for configuration or data logging.


4.3. Connecting Switch Buttons
- Identify Switch Cables: The switch button typically has a cable with a connector.
- Connect to BMS: Connect the switch button cable to the dedicated "Key extension interface" on your JIKONG BMS. This interface is used to control BMS startup and shutdown.


5. Operation Instructions
5.1. APP Operation Instructions
To configure your JIKONG BMS and its accessories via the APP:
- Open the JIKONG BMS APP on your mobile device (supports iOS, Android, and HarmonyOS).
- Navigate to the "Parameter Setting" page within the APP.
- Change the "Serial port 3 protocol" to "015-JK BMS PBxx SERIES LCD Protocol V1.0" to ensure proper communication with the LCD displays.

5.2. Display Interface Operation
5.2.1. Battery Interface
The battery interface on the display shows real-time information about your battery system:
- Battery Total Voltage: Current overall voltage of the battery string.
- Battery Power: Current power output/input.
- Single Series Voltage: Voltage of individual cells.
- Online Battery Pack Count: Number of connected battery packs.
- Charge/Discharge Status: Indicates if the battery is charging (CHG: ON) or discharging (DCH: ON).
- Cell Temperature: Highest and lowest cell temperatures.

5.2.2. Battery Pack Interface (Parallel Mode)
In parallel mode, you can select individual battery packs to view their specific details:
- Design Capacity: Original design capacity of the selected battery pack.
- Remaining Capacity: Current remaining capacity.
- Charge/Discharge Status: Status of the individual pack.
- Cell Voltages: Voltages of each cell within the pack.
Up to 16 battery packs can be displayed and monitored.

5.2.3. Protocol Selection Interface
The display allows you to select the appropriate communication protocol (RS485 or CAN) to match your BMS configuration.
- Navigate to the "Settings" or "Protocol Selection" menu on the display.
- Choose the correct RS485 Protocol Number (e.g., "015-JK BMS PBxx SERIES LCD Protocol V1.0").
- If using CAN communication, select the appropriate CAN Protocol Number (e.g., "000 - JK BMS CAN Protocol (250K) V2.0").

6. Maintenance
- Cleaning: Use a soft, dry cloth to clean the display screen. Avoid abrasive cleaners or solvents that may damage the surface.
- Environmental Conditions: Ensure the accessories are operated within the specified temperature and humidity ranges (refer to Section 3.4).
- Cable Integrity: Regularly inspect all cables for signs of wear, damage, or loose connections. Replace damaged cables immediately.
- Firmware Updates: Check the JIKONG official website or APP for any available firmware updates for your BMS and accessories to ensure optimal performance and new features.
7. Troubleshooting
- Display Not Turning On:
- Check power connections (9-36V).
- Ensure the switch button (if used) is properly connected and activated.
- Verify the display cable is securely connected to the BMS.
- No Data on Display:
- Confirm the TTL-RX/TX connections are correct.
- Check the APP's "Serial port 3 protocol" setting (should be "015-JK BMS PBxx SERIES LCD Protocol V1.0").
- Ensure the correct RS485 or CAN protocol is selected on the display interface.
- Verify the baud rate setting matches the BMS.
- Inaccurate Readings:
- Ensure all balance wires and main power cables are correctly connected to the BMS.
- Perform a calibration if available through the BMS APP.
8. User Tips
- Quality Assurance: JIKONG products are known for their high quality and performance. Ensure all connections are secure and follow the instructions carefully for reliable operation.
- Optimal Performance: For the best experience, always ensure your BMS and accessories are running the latest firmware.
- Professional Installation: If you are unsure about any installation steps, it is recommended to seek assistance from a qualified professional.
9. Product Dimensions
Detailed dimensions for the 4.3-inch display and standard cable lengths are provided below. Dimensions for other display sizes are available in the setup section.

Standard Cable Length: The standard cable length for connections is 0.5 meters (500mm). Custom lengths may be available.

10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the official JIKONG website or contact your authorized dealer. You can also find additional guides and documents, including the user manual in PDF format, at the following link:
JIKONG is committed to providing high-quality products and excellent customer service. For any issues not covered in this manual, please reach out to our support team.
11. Unboxing Video
Watch this video to see the unboxing and contents of the JIKONG BMS accessories package.