1. Introduction and Overview
The COMPTYCO KP600 is a state-of-the-art Optical Time Domain Reflectometer (OTDR) designed for comprehensive fiber optic network testing and maintenance. This versatile device integrates multiple essential functions, including an Optical Power Meter (OPM), Visual Fault Locator (VFL), Stable Light Source (LS), LED illumination, and RJ45 network testing, all accessible via a responsive 3.5-inch touch screen. With its automatic measurement and analysis capabilities, the KP600 simplifies complex tasks, making it an ideal tool for technicians in the field.
2. Product Features
- All-in-One Functionality: Integrates OTDR, Event Map, OPM, VFL, Stable Light Source (LS), Network Testing, Loss Test, and LED functions.
- Intuitive Touch Screen: Features a 3.5-inch multi-touch, fast, and sensitive LCD screen with a colorful soft light and high-definition display.
- Automatic Measurement: One-click test for automatic analysis, requiring minimal user operations.
- Active Fiber Test: Optional support for testing active fibers.
- Visual Fault Locator (VFL): Built-in VFL with a range exceeding 10km for quick fault identification.
- Optical Power Meter (OPM): Supports 9 wavelengths, self-calibration, and large capacity storage.
- Stable Light Source (LS): Output wavelength consistent with OTDR, supporting CW, 270Hz, 330Hz, 1000Hz, and 2000Hz modes.
- RJ45 Network Test: Connects to a remote module to test line sequence and length of network cables.
- Long Battery Life: Equipped with a 4000mAh lithium battery, rechargeable via a Type-C interface.
- Compact Design: Single machine weight approximately 360g, with dimensions of 17.3cm x 8cm x 3.8cm.
- Interchangeable Connectors: Supports replaceable SC and FC interfaces.
3. Package Contents
Upon opening the packaging box, please verify that all the following items are included:
- KP600 OTDR Host Unit
- Testing Report
- User Manual (this document)
- Charging Head
- Data Cable (Type-C)
- SC Converter Head
- Portable Bag
- Packaging Box
- FC Converter Head (pre-installed on the machine)
- RJ45 Receiver
- RJ45 Remote Adapter (pre-installed on the machine)
4. Specifications
| Category | Parameter | Value |
|---|---|---|
| OTDR | Model | KP600 |
| Wavelength | 1310/1550 ± 20nm (Standard), 1310nm, 1550nm, 1610nm, 1625nm, 1650nm | |
| Dynamic range | 24/22dB (Standard), 24dB, 22dB, 22dB, 22dB, 22dB | |
| Fiber type | G.652D | |
| Event blind area | 2.5m | |
| Attenuation blind zone | 8m | |
| Measuring range | 100m/500m/1km/2km/5km/10km/20km/40km/60km/100km | |
| Pulse width | 5ns/10ns/20ns/50ns/100ns/275ns/500ns/1us/2us/5us/10us | |
| Measurement accuracy | ± (1m + sampling interval + 0.005% X measurement range) | |
| Linearity | ± 0.2dB/dB | |
| Number of sampling points | Maximum 20000 | |
| Sampling resolution | 25cm-8m | |
| General | Loss resolution | 0.001dB |
| Range resolution | 0.001m | |
| Refractive index | 1.0000-2.0000 | |
| Reflection accuracy | ± 3dB | |
| File format | Standard SOR file format | |
| Laser safety level | Class 3B | |
| Environmental | Working environment temperature | -10 ℃ ~ 50 ℃ |
| Storage environment temperature | -40 ℃ ~ 70 ℃ | |
| Humidity | 0-90% Non-condensing | |
| Physical | Size | 173mm x 80mm x 38mm |
| Weight | 360g (including battery) | |
| OPM | Calibration wavelength | 850/1270/1300/1310/1490/1550/1577/1625/1650nm |
| Measurement range | -50~+26dBm | |
| Frequency identification | 270Hz/330Hz/1KHz/2KHz | |
| Uncertainty | ±5% | |
| Optical connector | Universal Head FC/SC/ST | |
| LS | Wavelength | Same OTDR output wavelength |
| Laser type | FP-LD | |
| Output power | -5dBm ±2dB (adjustable) | |
| Uncertainty | ±5% | |
| Optical connector | FC/SC (Interchangeable) | |
| Other | VFL | ≥10mW |
| Network cable test | Line sequence/line finding | |
| Battery | 4000mAh H/3.7V | |
| Charger | Type C charging | |
| Save | Internal ≥10000, external support SD card |
5. Setup
5.1 Initial Charging
Before first use, fully charge the KP600 OTDR. Connect the provided Type-C data cable to the device's charging port and the charging head to a power outlet. The device features a 4000mAh lithium battery for long operational life.
5.2 Optical Interface Connection
The KP600 OTDR supports interchangeable SC and FC interfaces. To connect a fiber, gently insert the appropriate connector into the optical port. Ensure the connection is clean and secure to prevent inaccurate readings.
5.3 RJ45 Network Test Setup
For RJ45 network testing, locate the remote module (often stored within the main unit). Eject the remote module by pressing the designated button. Connect one end of the RJ45 cable to the main unit and the other end to the remote module. Then, connect the network cable to be tested between the main unit and the remote module.
6. Operating Instructions
6.1 Power On/Off and Navigation
- Power On: Press and hold the red power button (
) until the screen illuminates. - Power Off: Press and hold the red power button until the shutdown prompt appears, then confirm.
- Navigation: Use the 3.5-inch touch screen for direct interaction with icons. Alternatively, use the directional buttons (up, down, left, right) and the 'OK' button for selection, and 'ESC' to go back.
6.2 OTDR Measurement
- From the main menu, tap the 'OTDR' icon.
- Ensure the fiber is properly connected to the OTDR port.
- Select desired test parameters (e.g., wavelength, pulse width, range) if not using default auto settings.
- Tap 'Start' to initiate the measurement. The device will perform automatic analysis and display the trace and event map.
6.3 Optical Power Meter (OPM)
- From the main menu, tap the 'OPM' icon.
- Connect the fiber to the OPM port.
- Select the appropriate calibration wavelength.
- The measured optical power will be displayed on the screen.
6.4 Visual Fault Locator (VFL)
- From the main menu, tap the 'VFL' icon.
- Connect the fiber to the VFL port.
- Activate the VFL. A red laser light will be emitted. Observe the fiber for any visible light leakage, indicating a fault.
6.5 Stable Light Source (LS)
- From the main menu, tap the 'LS' icon.
- Connect the fiber to the LS port.
- Select the desired output mode (CW, 270Hz, 330Hz, 1000Hz, or 2000Hz).
- The device will emit a stable light source at the selected wavelength.
6.6 RJ45 Network Test
- Ensure the RJ45 remote module is connected as described in Section 5.3.
- From the main menu, tap the 'RJ45 Test' icon.
- The device will automatically test the line sequence and length of the connected network cable.
6.7 Saving Test Results
After completing a test, tap the 'Save' icon on the screen. You can save test results to the internal storage (up to 10,000 records) or to an external SD card (not included).
7. Maintenance
- Cleaning Optical Ports: Regularly clean all optical ports (OTDR, OPM, VFL, LS) using appropriate fiber optic cleaning tools to ensure accurate measurements and prevent damage.
- Screen Care: Use a soft, lint-free cloth to clean the touch screen. Avoid abrasive materials or harsh chemicals.
- Battery Management: Charge the device regularly. Avoid completely draining the battery or leaving it uncharged for extended periods. For long-term storage, charge the battery to approximately 50%.
- Storage: Store the KP600 OTDR in its portable bag in a cool, dry place, away from direct sunlight and extreme temperatures. Refer to the specifications for recommended storage temperature and humidity ranges.
- Software Updates: Check the manufacturer's website periodically for any available firmware updates to ensure optimal performance and access to new features.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on | Low battery; Power button not pressed long enough | Charge the device fully; Press and hold the power button for 3-5 seconds. |
| Inaccurate optical measurements | Dirty optical connectors; Incorrect wavelength selected; Damaged fiber | Clean connectors thoroughly; Verify correct wavelength for OPM/LS; Inspect fiber for damage. |
| RJ45 test fails or shows incorrect results | Remote module not connected; Faulty RJ45 cable; Remote module battery low | Ensure remote module is properly connected; Test with a known good cable; Check remote module power. |
| Touch screen unresponsive | Software glitch; Screen protector interference; Extreme temperature | Restart the device; Ensure screen protector is properly applied; Operate within specified environmental temperatures. |
| Cannot save test data | Internal storage full; SD card not inserted or full; SD card error | Delete old data; Insert a formatted SD card; Replace SD card if faulty. |
9. User Tips
No specific user tips were available from provided reviews or Q&A content.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact details provided by your retailer or the official COMPTYCO support channels. Keep your purchase receipt as proof of purchase for any warranty claims.