1. Introduction
The JIKONG JK-BD6A20S10P Smart Battery Management System (BMS) is an intelligent protection board designed for large-capacity series lithium battery packs. It is compatible with 8S-20S Li-ion, LiFePO4, and LTO batteries. This BMS offers comprehensive features including voltage acquisition, high-current active balancing, overcharge/over-discharge/overcurrent/over-temperature protection, coulomb meter, Bluetooth communication, and optional GPS remote functionality.
The protection board utilizes energy transfer active balancing technology, providing a continuous balancing current of up to 0.6A. This ensures battery consistency, extends battery life, and delays aging. It is suitable for various applications such as small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage, base station backup power supplies, and solar power stations.
2. Package Contents
Upon opening your JIKONG BMS package, please verify that all the following items are included:
- JK-BD6A20S10P BMS x 1
- NTC (Negative Temperature Coefficient) Sensor x 1 (40cm long)
- Sampling Line B x 1 (70cm long)
- Sampling Line A x 1 (70cm long)
- 4.3-inch V15 Display x 1
- Display Cable x 1
3. Specifications
3.1. Basic Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 20-100 | V |
| Operating Power Consumption | <800 | mW |
| Operating Temperature | -30-70 | °C |
| Maximum Number of Collection Strings | 24 | String |
| Maximum Balancing Current | 0.6 | A |
| Maximum Charging Current | 100 | A |
| Maximum Discharge Current | 100 | A |
| Maximum Instantaneous Current | 200 | A |
| Maximum Internal Loop Resistance | 0.702 | mΩ |
| Protective Plate Size | 162*102*20.4 | mm |
| Finished Weight | 360 | g |
3.2. Default Parameters (JK-BD6A20S-10P)
| Parameter | Li-ion (Default) | LiFePO4 (Default) | LTO (Default) | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Maximum Balancing Current | 0.6 | 0.6 | 0.6 | A |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 30 | 30 | 30 | S |
| Charge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-circuit Protection Delay | 1500 | 1500 | 1500 | µS |
| Short Circuit Protection Release Time | 60 | 60 | 60 | S |
| Charging Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Charging Overtemperature Restore Temperature | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery Temperature | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection Temperature | -20 | -20 | -20 | °C |
| Charging Low Temperature to Restore Temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection Temperature | 100 | 100 | 100 | °C |
| MOS Overtemperature Protection Recovery Temperature | 80 | 80 | 80 | °C |
| Device Address | 0 | 0 | 0 | / |
3.3. Dimensions
The JIKONG JK-BD6AxxS-10P series protection board has dimensions of 162mm (length) × 102mm (width) × 20.4mm (thickness).
4. Setup & Installation
4.1. Wiring Instructions
The JK-BD6AxxS-10P series protection board is suitable for 7-24 series lithium battery packs. The specific wiring method varies depending on the number of cells in your battery pack. Always ensure correct polarity and secure connections.
For detailed wiring diagrams and interface definitions, please refer to the official PDF user manual. Ensure all balance cables are properly connected and the P- and B- terminals are correctly wired before powering on.
4.2. Device Activation
Before powering on the protection board, double-check all connections, especially the balance cables and the P- and B- terminals, to ensure they are correct and secure. Incorrect connections can lead to malfunctions or damage.
The BMS does not have a power-on control switch. It is designed for charging activation: connect the charger (with a voltage 2V higher than the battery voltage) to activate the BMS after battery assembly. Alternatively, if you have the optional display screen and button, you can activate the device by inserting the cable into the display interface and pressing the button.
4.3. APP Installation
The mobile APP for the JIKONG BMS supports both Android and iOS operating systems. To install the APP, scan the QR code below. An Android device requires a minimum of Android Version 7.
5. Operating Instructions
The JIKONG BMS offers a range of functions accessible via the mobile APP and optional display. Below are key operational aspects:
5.1. Active Equalization
The BMS actively balances cells by transferring energy from higher-voltage cells to lower-voltage cells. Before using this function, set basic battery parameters (cell count, capacity) in the APP. You can adjust the balance trigger voltage difference (mV) in the APP settings. When enabled, balancing automatically starts if the voltage difference between any two cells exceeds the set value and stops when it falls below. The default balance current is 0.6A, adjustable based on battery capacity (recommended not to exceed 0.2C).
5.2. GPS and Display Interface
The BMS includes interfaces for optional GPS modules and display screens. The GPS interface allows for battery location tracking, while the display interface (e.g., 4.3-inch V15 Display) provides real-time battery information. Users can select these options based on their needs.
5.3. Heating Function
For low-temperature environments, the BMS supports an optional heating function using a resistance heater or heating film. This prevents reduced battery activity and charging/discharging issues due to cold. The designed heating current is 4A. Control the heating function via the BMS control page in the APP. It is recommended to install a normally closed temperature switch (45°C to 65°C) in series with the heating circuit as a secondary protection.
5.4. Alarm Function
The BMS supports an optional alarm function to notify users of potential safety risks such as over-temperature, overcharge, or over-discharge conditions.
5.5. Protection Functions
- Charge Overvoltage Protection: Standard feature. Protects against overcharging by shutting off charging if any cell's voltage exceeds the set overvoltage protection value. Charging resumes when all cell voltages drop below the recovery voltage.
- Discharge Undervoltage Protection: Standard feature. Protects against over-discharging by shutting off discharge if any cell's voltage falls below the set undervoltage protection value. Discharge resumes when all cell voltages rise above the recovery voltage. If any cell voltage drops below the automatic shutdown voltage, the BMS will shut down.
- Charge Overcurrent Protection: Standard feature. Protects against excessive charging current. If the charging current exceeds the set continuous charging current for a specified delay, charging is stopped. It resumes after the overcurrent release time.
- Discharge Overcurrent Protection: Standard feature. Protects against excessive discharge current. If the discharge current exceeds the set continuous discharge current for a specified delay, discharge is stopped. It resumes after the overcurrent release time. (Note: Max continuous discharge current should not exceed 100A).
- Overtemperature Protection: Standard feature for both charge and discharge. Shuts down operation if temperature exceeds set limits and resumes when temperature drops to recovery levels.
- Low Temperature Protection: Standard feature for charging. Shuts down charging if temperature falls below set limits and resumes when temperature rises to recovery levels.
- Short Circuit Protection: Standard feature. Protects against short circuits. Users can adjust the short circuit protection delay and recovery time via the APP. If a short circuit occurs during charging or discharging, the BMS will temporarily shut down and attempt to recover after the set time.
5.6. Emergency Switch
The BMS includes a standard emergency switch function. If issues like over-temperature, over-discharge, over-charge, or cell string drops occur, activating the emergency switch via the APP's BMS control page will enable both charging and discharging for 30 minutes. This provides a temporary operational window, even if a single cell reaches the automatic shutdown voltage, to prevent critical failures.
5.7. Intelligent Sleep
The intelligent sleep function is standard and can be enabled/disabled via the APP. Its purpose is to reduce the BMS's energy consumption by entering a low-power state if the charging/discharging current is less than 1A for 26 consecutive hours. The BMS can be reactivated by pressing a button (if equipped) or by connecting a charger.
5.8. Communication Functions
The BMS supports optional CAN and RS485 communication functions. Users can configure the address and communication protocol via the APP based on their specific requirements and scenarios. Refer to the JIKONG Protection Board Communication Protocol document for detailed information.
5.9. Parameter Setting
Detailed instructions for setting various parameters are available in the "Instructions for Setting Protection Board Parameters" section of the full user manual PDF.
6. Maintenance
The JIKONG Smart BMS is designed for robust and reliable operation with minimal maintenance. Regular checks should include:
- Visual Inspection: Periodically inspect the BMS and all connected wiring for any signs of damage, corrosion, or loose connections.
- Software Updates: Keep the mobile APP updated to the latest version to ensure optimal performance and access to new features or bug fixes.
- Environmental Conditions: Ensure the BMS operates within its specified temperature range (-30°C to 70°C) and is protected from moisture and excessive dust.
No user-serviceable parts are inside the BMS unit. Do not attempt to open or repair the device yourself, as this will void the warranty and may cause damage or injury.
7. Troubleshooting
This section provides guidance on common issues and their potential solutions. For complex problems, refer to the detailed PDF manual or contact JIKONG customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| BMS not activating/powering on | Incorrect wiring (balance cables, P-/B-), charger voltage too low, or button not pressed (if applicable). | Verify all wiring connections. Ensure charger voltage is 2V higher than battery. Press activation button if using display. |
| Balancing not occurring | Balancing function disabled in APP, or cell voltage difference is below trigger threshold. | Enable balancing in APP. Check and adjust balance trigger voltage difference. |
| Charging/Discharging stops unexpectedly | Overvoltage, undervoltage, overcurrent, or overtemperature protection triggered. | Check battery voltage, current, and temperature via APP. Allow conditions to return to normal or activate emergency switch if critical. |
| Short circuit protection frequently triggered | High peak current from charger/load, or actual short circuit. | Verify external wiring for actual shorts. Increase short circuit protection delay in APP if peak currents are causing false triggers. |
| Bluetooth connection issues | APP not updated, Bluetooth disabled on phone, or interference. | Ensure APP is latest version. Check phone's Bluetooth settings. Reduce distance to BMS. |
If you encounter persistent issues, please consult the comprehensive JIKONG BMS User Manual (PDF) for more detailed troubleshooting steps or contact JIKONG customer support.
8. User Tips
- Always ensure your battery cells are closely matched in voltage and internal resistance before connecting to the BMS for optimal balancing performance.
- Regularly check the BMS status and battery parameters via the mobile APP to monitor health and prevent potential issues.
- When setting up, double-check all wiring connections multiple times to avoid costly damage from incorrect installation.
- If using the heating function, consider the recommended temperature switch for added safety and efficiency.
9. Support & Further Information
For comprehensive details, including advanced parameter settings, communication protocols, and detailed wiring diagrams, please refer to the official JIKONG BMS user manual in PDF format:
View JIKONG BMS User Manual (PDF)