HICOMDATA MINI 6-Port Intelligent Switch PCBA

Contents

HICOMDATA MINI 6-Port Intelligent Switch PCBA User Manual

Model: MINI 6-Port Intelligent Switch PCBA

1. Overview

The HICOMDATA MINI 6-Port Intelligent Switch PCBA is a Web Smart L2-managed switch designed for flexible networking. It features 4 adaptive RJ45 ports (10M/100M/1000M/2.5Gbps) and 2 SFP+ ports (1000M/2.5G/10Gbps). This device provides Layer 2 functionality for network management and configuration through a web-based interface.

The Web Smart system comprises a Web server integrated on the device and a Web client (browser) used to access and manage the device. This manual details the configuration and operation of the switch's features via its web interface.

HICOMDATA MINI 6-Port Intelligent Switch PCBA front view

Figure 1: HICOMDATA MINI 6-Port Intelligent Switch PCBA

Play video
Watch video online

Video 1: Product Overview

2. Setup and Initial Configuration

2.1. Powering On the Device

Important Safety Information:

  • Always power down and disconnect the power cord before servicing or wiring the switch.
  • Do not disconnect modules or cables unless the power is off.
  • The device supports specific voltage as listed on its nameplate. Use only the designated power components.
  • Disconnect the power cord before installation or cable wiring.

To power on, connect the AC power connector on the back panel of the switch to an external power source using the included power cord. Verify that the power LED illuminates.

2.2. Connecting to the Network

To connect the switch to your network:

  1. Connect an Ethernet cable from your computer to one of the switch's RJ45 ports.
  2. Ensure the port LED lights up, indicating an active connection.
  3. Repeat for additional devices as needed.

Note: Use CAT-5E or better Ethernet cables. The maximum cabling distance is 100 meters (328 feet). The switch ports automatically adjust to the characteristics (MDI/MDI-X, speed, duplex) of the connected device.

Switch PCBA with port labels: 2 SFP+ ports and 4 RJ45 ports, plus DC power interface

Figure 2: Switch PCBA Port Layout

2.3. Starting the Web-based Configuration Utility

To access the web-based configuration utility:

  1. Disable any pop-up blockers in your browser.
  2. Open a web browser (e.g., Chrome).
  3. Configure your host's IP address and subnet mask to be in the same network segment as the switch's default IP. The factory default IP address is 192.168.2.1 with a network mask of 255.255.255.0.
  4. Enter the switch's IP address (192.168.2.1) into the browser's address bar and press Enter.

2.4. Logging In

The default username is admin and the default password is admin.

  1. Enter the default username and password.
  2. If this is your first login, it is recommended to change your password immediately.

If an incorrect username or password is entered, an error message will appear. The application logs out after five minutes of inactivity. To log out manually, click the 'Logout' button in the top right corner of the page.

3. Web Smart Configuration and Operation

The web interface is divided into two main sections: a left-hand menu bar for navigation and a right-hand content area for configuration and display. The content area includes a port status bar at the top, language switch, and 'Logout' button, with the main configuration options below.

3.1. System Settings

3.1.1. Device Info

This page displays essential device information, including MAC address, IP address, firmware version, and date.

3.1.2. IP Settings

This page allows you to view and configure the device's management IP address. The default static IP is 192.168.2.1. If DHCP is enabled, the device will obtain an IP from an upstream device.

Tip: Changing the IP may cause a brief disconnection. If using automatic IP acquisition, ensure the upstream device provides the configured IP for web management.

3.1.3. User Management

Change the username and password for web interface login here. Passwords must be 6-16 characters and can include letters, numbers, and special characters: <=>[]!@#$*().

3.1.4. Device Management

This section provides options to:

  • Save Configurations: Prevents configurations from being lost after reboot.
  • Reboot: Restarts the device. Unsaved configurations will revert to default.
  • Restore Factory Settings: Restores both saved and unsaved configurations to factory defaults and restarts the device.

3.2. Switch Settings

3.2.1. Port Settings

View and configure connection status, rate, duplex, and flow control for all ports. You can configure ports individually or in batches.

Configuration: Select the port(s), configure properties (Admin Status, Speed/Duplex, Flow Control), and click 'Apply'.

Display: Shows current and effective attributes for each port.

3.2.2. Trunk Group Setting (Port Aggregation)

This page manages aggregation groups. You can add or clear groups and modify member ports. Supports LACP and static aggregation modes. Load balancing algorithms include source MAC, destination MAC, or both, and source/destination IP.

Tips:

  • Groups require 2-4 member ports.
  • Ports with ingress/egress rate limiting cannot be members.
  • Inconsistent rate/duplex/negotiation/flow control states prevent membership.
  • Ports already in another group cannot be added.
  • Ports in different VLANs cannot be members.
  • A maximum of two aggregation groups can be created.

Manage LACP state, system/port priority, and timeout. Used in conjunction with Port Aggregation. Displays aggregation group ID, port, priority, timeout, and status when LACP is enabled.

3.2.4. Loop Prevention

Configure and monitor loop control. If enabled, a loop will block the affected port. The port automatically recovers once the loop is released.

3.2.5. Port-based Mirroring

Configure port mirroring to forward input/output packets from source ports to a destination port for network monitoring.

Tips:

  • Source and destination ports cannot be the same.
  • Only one mirror group is supported.

3.2.6. Port Isolation

Configure isolation for device ports. You can select ports and add them to an isolation table.

3.2.7. Bandwidth Control

Configure exit/entry rate limits for each port.

Tips:

  • Speed limit configuration should be a multiple of 16. If not, it will be set to the next lower multiple of 16 (e.g., 100Kbit/sec becomes 96Kbit/sec).
  • Speed limit range: 0-24999999 Kbit/sec.

3.2.8. MAC Constraint

Configure MAC address learning restrictions for ports. Set events (flooding/discarding) and the maximum number of MAC addresses learned. If exceeded, the configured event is triggered, and the port will stop receiving/flooding excess traffic.

Tip: Entry limits range from 0-4160.

3.3. VLAN

Add or delete VLAN members and configure port VLANs.

3.3.1. Static VLAN

Add new VLAN members by entering a VLAN ID and optional name. You can also change a VLAN name by entering a duplicate ID with a new name. Delete VLAN members by selecting them and clicking 'Delete'.

Tips:

  • Up to 32 VLAN members can be configured.
  • A VLAN ID bound to a port cannot be deleted.
  • The default VLAN 1 cannot be changed or deleted.

3.3.2. VLAN Settings

Configure port VLANs (Access, Trunk, Permit VLAN, Native VLAN). Select the port, VLAN type, and relevant VLANs, then click 'Apply'.

Tip: Native VLANs do not have a VLAN tag.

3.4. QoS (Quality of Service)

3.4.1. Priority Selection

Configure priority weights for Port, 1Q, ACL, and DSCP. The priority with the highest weight takes effect.

Tip: Weight configuration range is 1-4.

3.4.2. DSCP Remapping

Configure DSCP priority and priority remapping.

3.4.3. Priority to Queue

Configure the priority of configuration and the corresponding queue ID.

3.4.4. Port-based Priority

Configure the priority for specific ports.

3.4.5. Queue Weight

Configure priority queues and their corresponding weights.

Tip: Weights are divided into strict priority and queue share (range 1-15).

3.5. IGMP (Internet Group Management Protocol)

3.5.1. IGMP Configuration

Enable/disable IGMP and configure static routing ports. After configuration, the port can forward traffic without joining a multicast group. Displays learned multicast IPv4 addresses, ports, and VLAN IDs.

3.6. MAC Address

Search for MAC addresses based on VLAN ID. Displays information about the searched MAC address, VLAN ID, address type, and port.

Tip: The waiting process during search may interrupt communication with the device.

3.6.2. Static MAC

Add static MAC addresses by entering a MAC address, VLAN ID, and port number. Static MAC entries can be deleted.

Tip: Up to 32 static MAC addresses can be configured.

3.7. Security

3.7.1. Storm Control

Configure storm control for ports. Select the type of storm control, port(s), and enable/disable it. When enabled, enter the rate at which storm control is configured.

Tip: Speed limit range 1-250000kbs/sec.

4. Maintenance

4.1. Monitoring

4.1.1. Port Statistics

This page displays data statistics and status for device ports, including received and sent packets. Click 'Clear' to recalculate the information.

4.1.2. Cable Diagnostic

Perform cable detection to understand the status of the corresponding port's cable (e.g., short circuit, disconnected). Check all ports and click 'Apply' to view detection results.

4.1.3. PoE (Power over Ethernet)

Tip: Some models support PoE functionality.

PoE Global Info: Displays global information on device PoE functionality.

PoE Port Status: Configure PoE power supply status, priority, and limited power for configured ports. Displays current power supply status for PoE ports.

Tip: Turning off port PoE will stop power delivery to that port.

4.2. Tools

4.2.1. Firmware Upgrade

To upgrade firmware:

  1. Click 'Enter Loading Mode'.
  2. Select the firmware file (XX.bin) from your computer.
  3. The switch will restart after the upgrade is complete.

4.2.2. Configuration Management

Backup and restore device configurations.

  • Backup: Click 'Backup' to generate an XX.bin file of the current configuration, which you can save.
  • Restore: Select a backed-up XX.bin file to import a configuration. The device's configuration will match the imported file.

5. Troubleshooting

5.1. Frequently Asked Questions

Question 1: Unable to log in to the device manager web management interface. What should I do?

Refer to the following steps:

  1. Confirm that the PC network cable is properly connected to the device port, and the corresponding indicator is flashing.
  2. Check if the network segment of the PC network card is in the same network segment as the switch's default IP (192.168.2.1).
  3. Use the ping command to test connectivity between your computer and the device.

Question 2: What if you forget your device username and password? How to restore the factory configuration?

If you forget the login password, long-press the reset key on the panel for 5 seconds while the device is powered on. The device will then restore to factory settings after restarting.

6. Specifications

Table of Product Parameters including Brand, Model, Ports, Bandwidth, MAC Address, Transmission Distance, Power, Environment, Size, Weight, and Certifications.

Figure 3: Product Parameters Table

General Specifications
AttributeValue
Brand NameHICOMDATA
ModelHK-ES3027M-2P4-W / HK-S207CW-62TS-SE (PCBA)
Switch TypeEthernet
Transmission Rate10000 Mbps
Switch Capacity60Gbps
Communication ModeFull-Duplex & Half-Duplex
FunctionLACP, QoS, VLAN Support
VLANYES
PackageYes
CertificationCE, FCC, RoHS, WEEE
OriginMainland China
Product Size (L*W*H)93mm*62mm*15mm
N.W/G.W (kg)0.05kg
Image showing the compact size of the switch PCBA with dimensions: Long: 93mm, Height: 15mm, Wide: 62mm.

Figure 4: Compact Size and Dimensions

7. User Tips

  • For optimal performance, ensure all connected cables are of high quality (CAT-5E or better) and within the recommended length limits.
  • Regularly check port statistics and perform cable diagnostics, especially if experiencing connectivity issues.
  • Always back up your configuration before performing firmware upgrades or major configuration changes.
  • If you encounter persistent issues, consider restoring to factory settings as a last resort, but remember to save your current configuration first if you wish to revert.

8. Warranty and Support

For detailed information regarding warranty, technical support, and further documentation, please refer to the official user manual PDF provided by HICOMDATA. A PDF version of the user manual is available for download and contains comprehensive guides and documents.

Reference: HICOMDATA MINI 6-Port Intelligent Switch PCBA User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.