DATOUBOSS DT-4862

Contents

DATOUBOSS DT-4862 Hybrid Solar Inverter

User Manual

1. Introduction

This manual describes the assembly, installation, operation, and troubleshooting of the DATOUBOSS DT-4862 Hybrid Solar Inverter. This multi-function inverter/charger combines the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support. Its comprehensive LCD display offers user-configurable and easy-accessible button operation for settings such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

Key Features:

  • Pure sine wave output.
  • Configurable input voltage range for home appliances and personal computers via LCD setting.
  • Configurable battery charging current based on applications via LCD setting.
  • Configurable AC/Solar Charger priority via LCD setting.
  • Compatible with mains voltage or generator power.
  • Auto restart while AC is recovering.
  • Overload, over temperature, and short circuit protection.
  • Smart battery charger design for optimized battery performance.
  • Cold start function.
  • Supports 48-volt lead-acid and lithium batteries, and can operate without batteries.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  • Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  • CAUTION: To reduce the risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  • Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  • To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  • CAUTION: Only qualified personnel can install this device with a battery.
  • NEVER charge a frozen battery.
  • For optimum operation, follow required specifications to select appropriate cable size.
  • Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts, which could cause an explosion.
  • Strictly follow the installation procedure when disconnecting AC or DC terminals.
  • A 150A fuse is provided as over-current protection for the battery supply.
  • GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Comply with local requirements and regulations.
  • NEVER cause AC output and DC input short circuits. Do NOT connect to the mains when DC input short circuits.
  • Warning!! Only qualified service persons are able to service this device.

3. Setup

3.1 Unpacking and Inspection

Before installation, inspect the unit for any damage. The package should contain:

  • The inverter unit x 1
  • User manual x 1

3.2 Preparation

Before connecting any wires, remove the bottom cover by unscrewing the two screws.

3.3 Mounting the Unit

Consider the following points when selecting an installation location:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install at eye level for easy LCD display reading.
  • Allow approximately 20 cm clearance to the sides and 50 cm above and below for proper air circulation and heat dissipation.
  • The ambient temperature should be between 0°C and 55°C for optimal operation.
  • The recommended installation position is vertically on a wall.
  • Ensure enough space for removing wires.

WARNING: Suitable for mounting on concrete or other non-combustible surfaces only.

Install the unit by screwing three screws:

  • Use M6*80mm expansion bolts for the top two mounting points.
  • Use M4 or M5 screws for the bottom mounting point.

3.4 Battery Connection

CAUTION: For safety and compliance, install a separate DC over-current protector or disconnect device between the battery and inverter.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for battery connection to reduce risk of injury.

Recommended battery cable and terminal size for 48V systems (DT-4862 is 6.2KVA):

Rated CapacityTypical AmperageBattery CapacityWire SizeCable (mm²)Ring Terminal D (mm)Ring Terminal L (mm)Torque Value
6.2KVA124A200AH1*2AWG / 2*4AWG38 / 258.4 / 8.439.2 / 33.25Nm

Steps to implement battery connection:

  1. Assemble battery ring terminals based on recommended cable and terminal size.
  2. Insert the battery wires flatly into the battery connectors of the inverter.
  3. Tighten the bolts with a torque of 2 Nm in a clockwise direction.
  4. Ensure correct polarity at both the battery and the inverter/charger.
  5. Ensure conductors are tightly screwed into the battery terminals.

CAUTION!! Before making the final DC connection or closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) is connected to negative (-).

3.5 AC Input/Output Connection

CAUTION!! Before connecting to an AC input power source, install a separate AC breaker between the inverter and the AC input power source. Recommended breaker spec for 48V system is 63A.

CAUTION!! There are two terminal blocks marked "IN" and "OUT". Do NOT mis-connect input and output connectors.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for AC input connection.

Suggested cable requirement for AC wires (for 6.2KVA):

Rated CapacityGaugeTorque Value
6.2KVA10AWG1.4~1.6Nm

Steps to implement AC input/output connection:

  1. Before making AC input/output connections, ensure the DC protector or disconnector is open.
  2. Remove insulation sleeve 10mm for six conductors. Shorten phase L and neutral conductor N by 3mm.
  3. Insert AC input wires according to polarities (Ground: yellow-green, Line: brown or black, Neutral: blue) indicated on the terminal block and tighten the terminal screws.
  4. Ensure all wires are securely connected.

3.6 PV Connection (Solar Charger Models Only)

CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for PV module connection.

Suggested cable requirement for PV wires:

Typical AmperageGaugeTorque Value
30A12AWG1.4~1.6Nm

PV module selection considerations:

  • The open circuit voltage (Voc) of the PV modules must not exceed the maximum PV array open circuit voltage of the inverter (500Vdc).
  • The maximum supply voltage of the PV modules should be close to the optimal PV access voltage range of the inverter (360-430Vdc) for best performance.
  • If one PV module cannot meet this requirement, connect multiple PV modules in series.

PV Specifications for DT-4862L:

  • MAX. PV Input Power: 8500W
  • MPPT Tracking Range: 60-500Vdc
  • Best Voltage: 360-430V
  • MAX. PV Input Voltage: 500Vdc
  • PV Max Input Current: 27A
  • MAX. PV Charging Current: 120A

Steps to implement PV module connection:

  1. Remove insulation sleeve 10 mm for positive and negative conductors.
  2. (Optional) Put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Check correct polarity of wires from PV modules and PV input connectors.
  4. Connect positive pole (+) of the connection wire to the positive pole (+) of the PV input connector.
  5. Connect negative pole (-) of the connection wire to the negative pole (-) of the PV input connector.
  6. Screw two wires tightly in a clockwise direction (recommended tool: 4mm blade screwdriver).

3.7 Final Assembly

After connecting all wirings, replace the bottom cover and secure it with the two screws.

Comprehensive Wiring Diagram for DATOUBOSS DT-4862 Hybrid Solar Inverter
Figure 3.7.1: Comprehensive Wiring Diagram. Connect generator/grid, solar panels, 48V battery, and household loads. Ensure proper grounding and use recommended cable sizes. Live/positive wire is red, neutral/negative wire is black.
DATOUBOSS DT-4862 Inverter Ports and Display Panel Labels
Figure 3.7.2: Inverter Ports and Display Panel. Rear panel shows AC Input, BMS/RS485, AC Output, Dry Contact, RS232, Parallel Connection, Ground Wire, DC Input, Power Switch, PV Input. Front panel shows LCD display, Status Indicator, Charging Indicator, Fault Indicator, ESC, UP, DOWN, ENTER buttons.

4. Operating Instructions

4.1 Power ON/OFF

Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the bottom of the case) to turn on the unit.

Start-up Steps:

  1. Connect the battery (voltage needs to be beyond 23V) or AC (AC input range depends on output mode).
  2. Mains Power On: Connect to normal AC power, press the switch. The system will automatically turn on. If AC output power priority is set, the panel will display 'AC mode'.
  3. Battery Boot: Connect to battery, press the power-on button. The system will automatically turn on, and the panel will display 'Battery mode'.

Shutdown Steps:

When the system is in battery mode or AC mode output, press the switch again to turn off the system.

4.2 Operation and Display Panel

The front panel includes an LCD display, three indicators (AC/INV, CHG, FAULT), and four function keys (ESC, UP, DOWN, ENTER) to show operating status and input/output power information.

LED Indicators:

  • AC/INV (Green): Solid On = Output powered by utility (Line mode). Flashing = Output powered by battery or PV (Battery mode).
  • CHG (Yellow): Solid On = Battery fully charged. Flashing = Battery charging.
  • FAULT (Red): Solid On = Fault occurs. Flashing = Warning condition occurs.

Function Keys:

  • ESC: To exit setting mode.
  • UP: To go to previous selection.
  • DOWN: To go to next selection.
  • ENTER: To confirm selection in setting mode or enter setting mode.

LCD Display Icons:

The LCD provides detailed information including input source (AC, PV1, PV2), input voltage/frequency, battery voltage, charger current, output voltage/frequency, load percentage, battery level, battery type, overload status, and operational modes (connected to mains, PV, solar charger working, inverter circuit working). A mute icon indicates when the unit alarm is disabled.

4.3 Display Settings