1. Introduction
This manual provides detailed instructions for the assembly, installation, operation, and troubleshooting of the Daxtromn Hybrid Solar Inverter. It combines the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support. Please read this manual carefully before installation and operation, and keep it for future reference.
The inverter features a comprehensive LCD display and easy-to-use buttons for configuring settings such as battery charging current, AC/solar charger priority, and acceptable input voltage ranges for various applications.
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation, follow required specifications to select appropriate cable size.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Strictly follow installation procedures when disconnecting AC or DC terminals.
- A 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Comply with local requirements and regulations.
- NEVER cause AC output and DC input short circuits. Do NOT connect to the mains when DC input short circuits.
- WARNING: Only qualified service persons are able to service this device. If errors persist after troubleshooting, send the inverter/charger to a local dealer or service center.
3. Product Overview
The Daxtromn Hybrid Solar Inverter is a multi-function device designed for various power applications. It features a pure sine wave output, configurable input voltage ranges, adjustable battery charging current, and AC/solar charger priority settings. It is compatible with both mains voltage and generator power, includes auto-restart functionality upon AC recovery, and offers comprehensive protection against overload, over-temperature, and short circuits. The smart battery charger design optimizes battery performance, and a cold start function is included.
The inverter is equipped with a built-in 160A MPPT solar charger and an anti-dust kit for harsh environments. It also supports a dual AC output function and features touch buttons for user interaction.
Figure 1: Product Overview Diagram
- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Touch Function buttons
- Power on/off switch
- AC input
- Main output
- Second output
- PV1 and PV2 input
- WIFI communication/RS-232 port
- Battery communication/RS-485 port
- Battery input
- Anti dust kit
This diagram illustrates the front and side views of the inverter, highlighting the LCD display, indicators, control buttons, and various input/output ports.
Figure 2: Product Display
Various views of the inverter, showcasing its design and physical layout from different angles.
Figure 3: Product Dimensions and Weight
The inverter measures 500mm x 390mm x 136mm and has a net weight of 14.5kg (for 8.2KW model) or 14.7kg (for 10.2KW model).
4. Setup and Installation
4.1 Unpacking and Inspection
Before installation, carefully inspect the unit for any damage. The package should contain:
- The inverter unit x 1
- User manual x 1 (PDF version available at User manual (PDF))
- Ring terminal x 1
- MC4 terminal head x 2
4.2 Mounting the Unit
Select a suitable location for mounting the inverter, considering the following:
- Mount on a solid, non-flammable surface.
- Install at eye level for easy LCD display readability.
- Ensure adequate air circulation: approximately 20 cm clearance to the sides and 50 cm above and below the unit for heat dissipation.
- The ambient temperature should be between 0°C and 55°C for optimal operation.
- The recommended installation position is vertically on a wall.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two M4 or M5 screws into the wall.
4.3 Battery Connection
CAUTION: For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. Refer to the table below for required fuse or breaker size.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for battery connection to reduce risk of injury.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 8.2KW/10.2KW | 1 x 2AWG | 25 | 2 Nm |
Follow these steps for battery connection:
- Remove 18 mm of insulation from positive and negative conductors.
- Use bootlace ferrules on the ends of the wires with a proper crimping tool.
- Connect all battery packs as shown in the diagram below.
- Insert battery wires into inverter connectors and tighten bolts to 2 Nm. Ensure correct polarity at both the battery and inverter/charger.
Figure 4: Battery Connection Diagram
Illustrates connecting four 12V batteries in series to the inverter. Ensure correct polarity and use recommended cable sizes.
WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage in series.
CAUTION: Before making the final DC connection or closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).
4.4 AC Input/Output Connection
CAUTION: Install a separate AC breaker between the inverter and AC input power source (recommended 63A for 8.2KW/10.2KW models). Do NOT mis-connect input and output connectors.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for AC input connection.
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 8.2KW/10.2KW | 10 AWG | 6 | 1.2 Nm |
Follow these steps for AC input/output connection:
- Before connecting, open the DC protector or disconnector.
- Remove 10mm insulation for six conductors. Shorten phase L and neutral conductor N by 3mm.
- Insert AC input wires according to polarities (Ground: yellow-green, L: brown/black, N: blue) and tighten terminal screws.
- Insert AC output wires according to polarities (L: brown/black, N: blue) and tighten terminal screws.
- Ensure all wires are securely connected.
Figure 5: AC Input/Output Connection Diagram
Detailed view of the terminal blocks for AC input and output, indicating proper wire connections and polarities.
4.5 PV Connection
CAUTION: Install a separate DC circuit breaker between the inverter and PV modules. Use appropriate cable for PV module connection.
| Model | Wire Size | Cable (mm²) | Torque Value |
|---|---|---|---|
| 8.2KW/10.2KW | 1 x 10AWG | 6 | 1.2 Nm |
When selecting PV modules, ensure the Open Circuit Voltage (Voc) does not exceed 500Vdc and is higher than the minimum battery voltage. The PV Array MPPT Voltage Range is 90Vdc~450Vdc.
CAUTION: Exceeding the maximum input voltage can destroy the unit! Check the system before wire connection.
Figure 6: PV Connection Diagram
Illustrates the overall solar power system setup, including solar panels, inverter, battery, and connections to AC output and home appliances.
Figure 7: PV Input Voltage Note
Important: If the solar inverter is used without an external battery, the PV input voltage must be above 120V for normal operation. If an external battery is connected, 90V is sufficient.
4.6 Communication Connection
The inverter supports Wi-Fi and GPRS cloud communication (optional) and battery communication.
- Wi-Fi/GPRS Communication: Use the supplied communication cable to connect to the inverter and the Wi-Fi/GPRS module. Download the appropriate app and follow the "Wi-Fi Plug Quick Installation Guideline" or "GPRS RTU Quick Installation Guideline" for setup and registration. Inverter status can then be monitored via mobile app or computer webpage.
- Battery Communication: Communication between the battery and inverter is achieved via the battery communication interface (Baud rate: 9600). The RJ45 connector of the communication cable connects to the BMS port of the inverter, and the other RJ45 connector connects to the RS485 port of the lithium battery. Ensure both lithium battery and inverter are turned off before connecting.
Figure 8: Lithium Battery Communication Cable Interface
Shows the RJ45 connections for BMS communication between the inverter and lithium battery. A-01 connects to BMS port on inverter, A-02 connects to RS485 port of lithium battery.
To enable communication with a lithium battery BMS, press and hold the "ENTER" button, set battery type to "LIB-485" in program 05, then select the matching battery protocol (PYLON or PACE) in Program 43.
5. Operation
5.1 Power ON/OFF
Once the unit is properly installed and batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.
5.2 Operation and Display Panel
The front panel of the inverter features an LCD display, three indicators, and four touch function keys for operation and monitoring.
| LED Indicator | Color | State | Message |
|---|---|---|---|
| INV/AC | Green | Solid On | Output is powered by utility in Line mode. |
| Flashing | Output is powered by battery or PV in battery mode. | ||
| CHG | Green | Solid On | Battery is fully charged. |
| Flashing | Battery is charging. | ||
| FAULT | Red | Solid On | Fault occurs in the inverter. |
| Flashing | Warning condition occurs in the inverter. |
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
5.3 LCD Display Icons
The LCD displays various icons to indicate the inverter's status and information:
- Input Source Information: Icons for AC input and PV input. Displays input voltage, frequency, PV voltage, charger current, charger power, and battery voltage.
- Configuration Program and Fault Information: Indicates setting programs, warning codes (flashing), and fault codes (lighting).
- Output Information: Displays output voltage, frequency, load percentage, load in VA, load in Watt, and discharging current.
- Battery Information: Shows battery status.
- Load Information: Overload indicator.
- Mode Operation Information: Indicates connection to mains, PV panel, load supplied by utility, utility charger circuit working, DC/AC inverter circuit working.
- Mute Operation: Indicates unit alarm is disabled.
5.4 LCD Settings
To enter setting mode, press and hold the "ENTER" button for 3 seconds. Use "UP" or "DOWN" to select programs, and "ENTER" to confirm or "ESC" to exit.
Figure 9: Output Source Priority Setting (Program 01)
This setting configures how the inverter prioritizes power sources for the load. Options include Utility first (01 USB), Solar first (01 SUB, default), SBU priority (01 SBU), and MKS priority (01 ntS).
Figure 10: Off-Grid or Hybrid Mode Setting (Program 37)
This setting determines the inverter's operational mode. "37 OFF" (default) means the inverter operates only in off-grid mode, with solar energy as first priority for loads and then charging. "37 HYd" means hybrid mode, where solar energy provides power to loads first, then charging, and excess energy can be fed to the grid.
Key configurable programs include:
- Program 00: Exit setting mode (GOE for one-button restore, GOK to exit).
- Program 01: Output source priority (Utility first, Solar first (default), SBU priority, MKS priority).
- Program 02: Maximum charging current (10A to 160A).
- Program 03: AC input voltage range (APL for Appliances 90-280VAC, UPS for UPS 170-280VAC).
- Program 05: Battery type (AGM, Flooded, User Defined, LIB). If "LIB-485" is selected, specific battery settings (12, 13, 29) are displayed as percentages.
- Program 06/07: Auto restart when overload/over temperature occurs (enable/disable).
- Program 09/10: Output frequency (50Hz/60Hz) and voltage (220V/230V/240V).
- Program 11: Maximum utility charging current.
- Program 12/13: Battery SOC points for switching to utility/battery mode in SBU/Solar first modes.
- Program 26/27/29: Bulk charging voltage, floating charging voltage, and low DC cut-off voltage (or low SOC shutdown point for LIB-485).
- Program 30-36: Battery equalization settings (enable/disable, voltage, time, timeout, interval, immediate activation).
- Program 37: GRID-tie operation mode (Off-grid or Hybrid).
- Program 41/42/45: Dual output function settings (enable/disable, functional voltage point, maximum second load percentage).
- Program 43: Lithium battery protocol (PYLON or PACE).
5.5 Operating Mode Description
The inverter supports various working modes, including operation without a battery connected and operation with a battery connected. These modes dictate how power is sourced and distributed to connected loads.
Figure 11: Various Working Modes
This diagram illustrates different power flow scenarios for the inverter, both with and without a battery connected, showing how solar, generator, utility, and battery power are utilized to supply home appliances.
The inverter also features RGB lights to indicate the current operating mode:
- Battery Mode: Red Light
- Utility Mode: Blue Light
- PV Mode: Purple Light
5.6 Battery Equalization
The equalization function helps reverse the buildup of negative chemical effects like stratification and removes sulfate crystals from battery plates, optimizing battery performance and lifespan. It is recommended to equalize batteries periodically.
To apply equalization, enable the function in LCD setting program 30. You can then set an equalization interval in program 35 or activate equalization immediately in program 36. The controller will enter the Equalize stage when the set interval is reached or immediately activated.
5.7 Mains and Lithium Battery Activation Function
- After 90 seconds of mains power connection, the inverter will connect to the mains and begin operation.
- If the inverter is in lithium battery mode (Program 05 set to LIB or LIL) and the mains are connected but the battery is not, the mains activation function will automatically enable.
6. Maintenance
6.1 Clearance and Maintenance for Anti-Dust Kit
The inverter comes with a pre-installed anti-dust kit to protect against dust and increase product reliability. The inverter automatically detects this kit and adjusts its internal thermal sensor to manage temperature.
Procedure:
- Loosen the screw on the top of the inverter in a counterclockwise direction.
- Remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and dustproof case. Re-assemble the dust-kit back to the inverter.
NOTICE: The anti-dust kit should be cleaned from dust every one month.
7. Troubleshooting
This section provides guidance for common issues, fault codes, and warning indicators. For persistent errors, contact a qualified service person.
7.1 Fault Reference Codes
When a fault occurs, the LCD will display a fault code. Refer to the table below for explanations and corrective actions.
| Fault Code | Fault Event | What to do |
|---|---|---|
| 01 | Fan is locked when inverter is off. | Return to repair center. |
| 02 | Over temperature | Check air flow, ambient temperature. |
| 03 | Battery voltage is too high | Check battery specifications. |
| 04 | Battery voltage is too low | Re-charge or replace battery. |
| 05 | Output short circuited or over temperature detected by internal converter components. | Check wiring, reduce load. |
| 06 | Output voltage is too high. | Return to repair center. |
| 07 | Overload time out | Reduce connected load. |
| 08 | Bus voltage is too high | Return to repair center. |
| 09 | Bus soft start failed | Return to repair center. |
| 51 | Over current or surge | Restart unit, if error persists, return to repair center. |
| 52 | Bus voltage is too low | Restart unit, if error persists, return to repair center. |
| 53 | Inverter soft start failed | Return to repair center. |
| 55 | Over DC voltage in AC output | Return to repair center. |
| 57 | Current sensor failed | Return to repair center. |
| 58 | Output voltage is too low | Return to repair center. |
| 59 | PV voltage is over limitation | Return to repair center. |
7.2 Lithium Battery Fault Codes
| Fault Code | Fault Event | Fault Condition |
|---|---|---|
| 02 | The battery temperature is too high | Lithium battery charging temperature ≥65°C; Discharge temperature ≥70°C. |
| 03 | The battery voltage is too high | Lithium battery maximum single cell voltage >3.65V; Total voltage of lithium battery >54.6V (48V lithium battery). |
| 04 | The battery voltage is too low | Minimum voltage of a lithium battery cell <2.71V; Total voltage of lithium battery <40.4V (48V lithium battery). |
7.3 Warning Indicators
Warning events are indicated by audible alarms and flashing icons. Refer to the table below for details.
| Warning Code | Warning Event | Audible Alarm |
|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second |
| 03 | Battery is over-charged | Beep once every second |
| 04 | Low battery | Beep once every second |
| 07 | Overload | Beep once every 0.5 second |
| 10 | Output power derating | Beep twice every 3 seconds |
| 15 | PV energy is low. | Beep twice every 3 seconds |
| E9 | Battery equalization | None |
| 6P | Battery is not connected | None |
| Warning Code | Warning Event | Warning Condition |
|---|---|---|
| 04 | The battery voltage is too low | Minimum voltage of a lithium battery cell <2.85V; Total voltage of lithium battery <42V (48V lithium battery). |
| 05 | The battery voltage is too high | Lithium battery maximum single cell voltage >3.55V; Total voltage of lithium battery >54V (48V lithium battery). |
| 06 | The battery is low warning | Remaining battery capacity ≤10% |
8. Specifications
The following tables detail the technical specifications for the Daxtromn Hybrid Solar Inverter (8.2KW and 10.2KW models).
Figure 12: Product Label Specifications
A detailed view of the product label, listing key specifications for the inverter charger, including PV input, Grid/AC output, two load output power, AC input, and battery parameters.
| Feature | 8.2KW | 10.2KW |
|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | |
| Nominal Input Voltage | 230Vac | |
| Low Loss Voltage (UPS) | 170Vac±7V | |
| Low Loss Voltage (Appliances) | 90Vac±7V | |
| Low Loss Return Voltage (UPS) | 180Vac±7V | |
| Low Loss Return Voltage (Appliances) | 100Vac±7V | |
| High Loss Voltage | 280Vac±7V | |
| High Loss Return Voltage | 270Vac±7V | |
| Max AC Input Voltage | 300Vac | |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | |
| Low Loss Frequency | 40±1Hz | |
| Low Loss Return Frequency | 42±1Hz | |
| High Loss Frequency | 65±1Hz | |
| High Loss Return Frequency | 63±1Hz | |
| Output Short Circuit Protection | Circuit Breaker | |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |
| Transfer Time (UPS) | 10ms typical | |
| Transfer Time (Appliances) | 20ms typical | |
| Feature | 8.2KW | 10.2KW |
|---|---|---|
| Rated Output Power | 8.2KW | 10.2KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230Vac±5% | |
| Output Frequency | 50Hz | |
| Peak Efficiency | 93% | |
| Overload Protection | 3s@≥150% load; 5s@101%~150% load | |
| Surge Capacity | 2* rated power for 5 seconds | |
| Nominal DC Input Voltage | 48Vdc | |
| Cold Start Voltage | 46.0Vdc | |
| Low DC Warning Voltage (<50% load) | 44.0Vdc | |
| Low DC Warning Voltage (≥50% load) | 42.0Vdc | |
| Low DC Warning Return Voltage (<50% load) | 45.0Vdc | |
| Low DC Warning Return Voltage (≥50% load) | 44.0Vdc | |
| Low DC Cut-off Voltage (<50% load) | 41.0Vdc | |
| Low DC Cut-off Voltage (≥50% load) | 40.0Vdc | |
| High DC Recovery Voltage | 62Vdc | |
| High DC Cut-off Voltage | 63Vdc | |
| No Load Power Consumption | 70W | 75W |
| Feature | 8.2KW | 10.2KW |
|---|---|---|
| Full Load | 8200W | 10200W |
| Maximum Main Load | 8200W | 10200W |
| Second Load Range | 1640W~5740W | 2040W~7140W |
| Main Load Cut Off Voltage | 52VDC | |
| Main Load Return Voltage | 54VDC | |
| Feature | 8.2KW | 10.2KW |
|---|---|---|
| Charging Algorithm | 3-Step | |
| AC Charging Current (Max) | 140Amp | 140Amp |
| Bulk Charging Flooded Battery | 58.4V | |
| Voltage AGM / Gel Battery | 56.4V | |
| Floating Charging Voltage | 54Vdc | |
| MPPT Solar Charging Mode IMax.PV (PV1 Channel) | 18A | |
| MPPT Solar Charging Mode IMax.PV (PV2 Channel) | 18A | |
| Nominal PV Voltage | 360Vdc | |
| PV Array MPPT Voltage Range | 90Vdc~450Vdc | |
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| Max Charging Current (AC charger plus solar charger) | 160Amp | |
| Feature | 8.2KW | 10.2KW |
|---|---|---|
| Nominal Output Voltage | 220/230/240 VAC | |
| Feed-in Grid Voltage Range | 195~253VAC | |
| Feed-in Grid Frequency Range | 50±1Hz/60±1Hz | |
| Nominal Output Current | 35.6A | 44.3A |
| Power Factor Range | ≥0.99 | |
| Maximum Conversion Efficiency (DC/AC) | 98% | |
| Feature | 8.2KW | 10.2KW |
|---|---|---|
| Safety Certification | CE | |
| Operating Temperature Range | -10°C to 50°C | |
| Storage Temperature | -15°C~60°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Dimension (D*W*H), mm | 500*390*136mm | |
| Net Weight, kg | 14.5 | 14.7 |
8.1 Approximate Back-up Time Table
The following table provides approximate backup times based on load and battery capacity. Note that actual backup time depends on battery quality, age, and type.
| Model | Load (W) | Backup Time @ 100Ah (min) | Backup Time @ 200Ah (min) |
|---|---|---|---|
| 8.2KW / 10.2KW | 500 | 613 | 1288 |
| 1000 | 268 | 613 | |
| 1500 | 158 | 402 | |
| 2000 | 111 | 271 | |
| 2500 | 90 | 215 | |
| 3200 | 76 | 182 | |
| 3500 | 65 | 141 | |
| 4000 | 50 | 112 | |
| 4500 | 44 | 100 | |
| 5000 | 40 | 90 | |
| 10.2KW | 6200 | 36 | 80 |
| 7200 | 32 | 70 | |
| 8200 | 28 | 60 | |
| 9200 | 24 | 50 | |
| 10200 | 20 | 40 |
9. User Tips
- Grid Feedback: This inverter is a hybrid solar inverter and can feed power back to the grid. Ensure local regulations are met for grid-tie operation.
- PV Panel Flexibility: You can connect two strings of solar panels with different specifications to this inverter.
- BMS Compatibility: For optimal battery life and safety, ensure both your inverter and external battery have BMS (Battery Management System) functions to allow communication and automatic parameter adjustments. Supported BMS protocols include PACE and PYLON.
- PV Input Voltage (No Battery): If operating the inverter without an external battery, the voltage from the solar panels must be above 120VDC for the inverter to function correctly.
- PV Input Voltage (With Battery): If operating with an external battery, the PV input voltage can be as low as 90VDC.
- Dual AC Output: The inverter has a dual AC output function. If the main AC input/grid is unavailable and the battery voltage is low, the main AC output will automatically cut off, and only the second AC output will be powered by the battery or PV. DO NOT CONNECT THE SECOND OUTPUT TO THE GRID.
- Parallel/Series Connection: This inverter does not support parallel or series connection with other inverters.
10. Warranty and Support
The Daxtromn Hybrid Solar Inverter comes with a 1-year warranty.
For detailed technical support, troubleshooting beyond the scope of this manual, or warranty claims, please contact your local dealer or authorized service center.
A comprehensive user manual in PDF format is available for download: User manual (PDF).
The product is CE certified, ensuring compliance with European safety standards.