1. Introduction
This PowMr POW-HVM10.2M is a multi-function grid-tied inverter/charger, combining the functionalities of an inverter, solar charger, and battery charger. It is designed to provide uninterruptible power support in a portable size. The unit features a comprehensive LCD display and user-configurable, easy-to-access button operations for settings such as battery charging current, AC/solar charger priority, and acceptable input voltage, catering to various applications.
1.1 Key Features
- Pure sine wave solar inverter (on/off Grid).
- Inverter running without battery.
- Output power factor 1.0.
- High PV input voltage range (90 ~ 500VDC).
- WIFI & GPRS available for IOS and Android (optional module).
- Built-in anti-dust kit for harsh environments.
- Built-in 160A MPPT solar charge controller.
- Smart battery charging design to optimize battery life.
- One-click restoration to factory settings.
- Dual AC output and dual PV input.
- Built-in Lithium battery automatic activation.
- Touch button interface.
1.2 Basic System Architecture
The following diagram illustrates the basic system architecture for this inverter/charger. It includes connections to PV panels, a generator, utility grid, battery, and household loads.
1.3 Product Overview
The inverter features a clear LCD display, status indicators, charging indicator, fault indicator, and function buttons for easy control and monitoring. The rear panel includes various connection ports for AC input/output, PV input, and communication.
2. Safety Instructions
This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with battery.
- Never charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to INSTALLATION section in this manual for the details.
- Over-current for the loads is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to connect with local requirements and regulation to install this inverter.
- Never cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
3. Setup
3.1 Unpacking and Inspection
Before installation, carefully inspect the unit. Ensure no damage occurred during transit. The package should contain:
- The inverter unit x 1
- User manual x 1
- Ring terminal x 1
- MC4 terminal head x 2
Watch the unboxing video for a visual guide:
3.2 Preparation
Before connecting any cables, remove the screws located under the machine and detach the bottom cover plate.
3.3 Mounting the Unit
When selecting a mounting location, consider the following:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level for optimal LCD display visibility.
- Ensure proper air circulation for heat dissipation; allow approximately 20 cm clearance to the sides and 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C for optimal operation.
- The recommended installation position is vertically on a wall.
- Ensure sufficient space around the machine for heat dissipation and wire management.
The unit should be installed by screwing two M4 or M5 screws into a concrete or other non-combustible surface.
3.4 Battery Connection
Follow these steps for battery connection:
- Remove 18 mm of insulation sleeve from positive and negative conductors.
- Attach bootlace ferrules to the ends of positive and negative wires using a proper crimping tool.
- Connect all battery packs as shown in the diagram below.
- Insert the battery wires flatly into the inverter's battery connectors. Ensure bolts are tightened with a torque of 2 Nm in a clockwise direction. Verify correct polarity at both the battery and the inverter/charger, and ensure conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.
WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.
CAUTION: Before making the final DC connection or closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).
3.5 AC Input/Output Connection
Before connecting to the AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter is securely disconnected during maintenance and fully protected from over-current. The recommended AC breaker for 10.2KW is 80A.
There are two terminal blocks with "IN" and "OUT" markings. Do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by a qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 8.2KW/10.2KW | 10 AWG | 6 | 1.2 Nm |
Follow these steps to implement AC input/output connection:
- Before making AC input/output connection, be sure to open DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. And shorten Phase L and neutral conductor N 3 mm.
- Insert AC input wires according to the indicated on terminal block and tighten the terminal screws. Be sure to connect PE (yellow-green), L (brown or black), and N (blue) conductors correctly.
WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
Then, insert AC output wires according to polarities indicated on terminal block and tighten terminal screws. L=LINE (brown or black), N=Neutral (blue).
Make sure the wires are securely connected.
3.6 PV Connection
PV module selection:
- Open circuit voltage (Voc) of PV modules must not exceed max. PV array open circuit voltage of inverter.
- Open circuit voltage (Voc) of PV modules should be higher than min. battery voltage.
| INVERTER MODEL | 8.2KW/10.2KW |
|---|---|
| Max. PV Array Open Circuit Voltage | 500VDC |
| PV Array MPPT Voltage Range | 90VDC~450VDC |
CAUTION: Exceeding the maximum input voltage can destroy the unit! Check the system before wire connection.
3.7 Communication Connection
The inverter supports various communication options:
- Wi-Fi cloud communication (option): Use a Wi-Fi module to connect to the inverter. Download the APP and register to set up network and monitoring. The inverter status can be viewed via mobile phone APP or web.
- GPRS cloud communication (option): Use a GPRS module to connect to the inverter. Download the APP and register to set up network and monitoring. The inverter status can be viewed via mobile phone APP or web.
- Battery communication: The communication between the battery and the inverter is realized through the battery communication interface, allowing information exchange (Baud rate: 9600).
3.7.1 Lithium battery and inverter connection:
Use power cables and communication cables for lithium batteries and inverters. Ensure correct installation of positive and negative positions. The RJ45 connector of the communication cable connects to the BMS port of the inverter, and the other RJ45 connector connects to the RS485 port of the lithium battery. Before connecting, ensure both the lithium battery and inverter are turned off. It is recommended to install a circuit breaker for the power cables of the lithium battery and the inverter battery interface to prevent sparks.
4. Operating
4.1 Power ON/OFF
Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the button of the case) to turn on the unit.
4.2 Operation and Display Panel
The operation and display panel on the front of the inverter includes three indicators, four function keys, and an LCD display, providing operating status and input/output power information.
| LED Indicator | Messages |
|---|---|
| INV/AC (Green Solid On) | Output is powered by utility in Line mode. |
| INV/AC (Green Flashing) | Output is powered by battery or PV in battery mode. |
| CHG (Green Solid On) | Battery is fully charged. |
| CHG (Green Flashing) | Battery is charging. |
| FAULT (Red Solid On) | Fault occurs in the inverter. |
| FAULT (Red Flashing) | Warning condition occurs in the inverter. |
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4.3 LCD Display Icons
The LCD display provides detailed information about input source, configuration, faults, output, and battery status through various icons and values.
4.4 LCD Setting
Press and hold the ENTER button for 3 seconds to enter setting mode. Use UP/DOWN buttons to navigate and ENTER to confirm. Press ESC to exit.
Key settings include:
- Program 00: Exit setting mode
- Program 01: Output source priority (Utility first, Solar first, SBU priority, MKS priority)
- Program 02: Maximum charging current (10A to 160A)
- Program 03: AC input voltage range (Appliances, UPS)
- Program 05: Battery type (AGM, Flooded, User Defined, LIB-485)
- Program 06: Auto restart when overload occurs
- Program 07: Auto restart when over temperature occurs
- Program 09: Output frequency (50Hz, 60Hz)
- Program 10: Output voltage (220V, 230V, 240V)
- Program 11: Maximum utility charging current (2A to 140A)
- Program 12: Setting voltage point back to utility source (42V to 51V)
- Program 13: Setting voltage point back to battery mode (48V to 58V)
- Program 16: Charger source priority (Solar first, Solar and Utility, Only Solar)
- Program 18: Alarm control (On/Off)
- Program 19: Auto return to default display screen
- Program 20: Backlight control (On/Off)
- Program 22: Beeps while primary source is interrupted
- Program 23: Overload bypass
- Program 25: Record fault code
- Program 26: Bulk charging voltage (C.V voltage)
- Program 27: Floating charging voltage
- Program 29: Low DC cut-off voltage
- Program 30: Battery equalization (Enable/Disable)
- Program 31: Battery equalization voltage
- Program 33: Battery equalized time
- Program 34: Battery equalized timeout
- Program 35: Equalization interval
- Program 36: Equalization activated immediately
- Program 37: GRID-tie operation (Off grid, Hybrid)
- Program 38: GRID-tie current
- Program 39: Led pattern light (Off/On)
- Program 41: Dual output (Disable/Use)
- Program 42: Enter the dual output functional voltage point
- Program 43: Lithium battery protocol (PYLON, PACE)
- Program 44: Delayed grid access (Disable/Enable)
- Program 46: Maximum Second Load (20%~70%)
4.5 Operating Mode Description
The inverter supports various operating modes, including Line mode, Stationary mode, Battery mode, and Grid-Tie Operation. Each mode has specific input and output characteristics, which are displayed on the LCD.
4.6 Battery Equalization Description
Battery equalization helps reverse the buildup of negative chemical effects like stratification and sulfation, which can reduce battery capacity. The function is added into the charge controller. It's recommended to equalize batteries periodically.
To apply equalization, enable the function in monitoring LCD setting program 30. Then, you can either set an equalization interval in program 35 or activate equalization immediately in program 36.
In the Equalize stage, the controller supplies power to charge the battery until it reaches the equalization voltage. Constant-voltage regulation maintains this voltage. If the battery does not reach equalization voltage within the timeout, the charge controller will extend the time or stop equalization and return to float stage.
4.7 Mains and Lithium Battery Activation Function
- After 90 seconds of mains power connection to the inverter, the machine connects to the mains and starts working.
- If the inverter is in lithium battery mode (item 05 is LIP or LIL), and the mains are connected but the battery is not, the mains activation function is automatically enabled.
5. Maintenance
5.1 Clearance and Maintenance for Anti-Dust Kit
Every inverter comes with a factory-installed anti-dust kit. This kit helps keep dust out of the inverter and increases product reliability in harsh environments. The inverter automatically detects this kit and adjusts its internal thermal sensor to maintain optimal temperature.
- Step 1: Loosen the screw on the top of the inverter in a counterclockwise direction.
- Step 2: Remove the dustproof case and take out the air filter foam.
- Step 3: Clean the air filter foam and dustproof case. After cleaning, re-assemble the dust-kit back into the inverter.
NOTICE: The anti-dust kit should be cleaned from dust every one month.
6. Troubleshooting
6.1 Fault Reference Code
If the inverter experiences a fault, an error code will be displayed. Refer to the table below for common fault codes and their descriptions.
| Fault Code | Fault Event | What to do |
|---|---|---|
| 01 | Fan is locked when inverter is off. | 1. Re-charge battery. 2. Replace battery. |
| 02 | Over temperature | Check if AC wires are too thin and/or too long. |
| 03 | Battery voltage is too high | 1. Contact repair center for replacing the fuse. 2. Re-charge battery. 3. Replace battery. |
| 04 | Battery voltage is too low | Check if AC breaker is tripped and AC wiring is connected well. |
| 05 | Output short circuited or over temperature is detected by internal converter components. | Reduce the connected load by switching off some equipment. |
| 06 | Output voltage is too high. | Check if wiring is connected well and remove abnormal load. |
| 07 | Overload time out | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. |
| 08 | Bus voltage is too high | Return to repair center. |
| 09 | Bus soft start failed | Check if spec and capacity of batteries can meet requirements. |
| 51 | Over current or surge | Replace the fan. |
| 52 | Bus voltage is too low | 1. Reduce the connected load. 2. Return to repair center. |
| 53 | Inverter soft start failed | Return to repair center. |
| 55 | Over DC voltage in AC output | Restart the unit, if the error happens again, please return to repair center. |
| 57 | Current sensor failed | |
| 58 | Output voltage is too low | |
| 59 | PV voltage is over limitation |
6.2 Warning Indicator
The inverter provides warning indicators for various conditions. Refer to the table below for details.
| Warning Code | Warning Event | Audible Alarm | Icon flashing |
|---|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second | 01 |
| 03 | Battery is overcharged | Beep once every second | 03 |
| 04 | Low battery | Beep once every second | 04 |
| 07 | Overload | Beep once every 0.5 second | 07 |
| 10 | Output power derating | Beep twice every 3 seconds | 10 |
| 15 | PV energy is low. | Beep twice every 3 seconds | 15 |
| E9 | Battery equalization | None | E9 |
| bP | Battery is not connected | None | bP |
7. Specifications
7.1 Table 1 Line Mode Specifications
| INVERTER MODEL | 8.2KW | 10.2KW |
|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | |
| Nominal Input Voltage | 230Vac | |
| Low Loss Voltage | 170Vac±7V (UPS); | 90Vac±7V (Appliances) |
| Low Loss Return Voltage | 180Vac±7V (UPS); | 100Vac±7V (Appliances) |
| High Loss Voltage | 280Vac±7V | |
| High Loss Return Voltage | 270Vac±7V | |
| Max AC Input Voltage | 300Vac | |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | |
| Low Loss Frequency | 40±1Hz | |
| Low Loss Return Frequency | 42±1Hz | |
| High Loss Frequency | 65±1Hz | |
| High Loss Return Frequency | 63±1Hz | |
| Output Short Circuit Protection | Circuit Breaker | |
| Efficiency (Line Mode) | >95% ( Rated R load, battery full charged ) | |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | |
7.2 Table 2 Inverter Mode Specifications
| INVERTER MODEL | 8.2KW | 10.2KW |
|---|---|---|
| Rated Output Power | 8.2KW | 10.2KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230Vac±5% | |
| Output Frequency | 50Hz/60Hz | |
| Peak Efficiency | 93% | |
| Overload Protection | 3S @ ≥150% load; 5S @ 101% ~ 150% load | |
| Surge Capacity | 2 * rated power for 5 seconds | |
| Nominal DC Input Voltage | 48VDC | |
| Cold Start Voltage | 46.0VDC | |
| No Load Power Consumption | 75W | |
7.3 Table 3 Two Load Output Power
| INVERTER MODEL | 8.2KW | 10.2KW |
|---|---|---|
| Full Load | 8200W | 10200W |
| Maximum Main Load | 8200W | 10200W |
| Second Load Range | 1640W~5740W | 2040W~7140W |
| Main Load Cut Off Voltage | 52VDC | |
| Main Load Return Voltage | 54VDC | |
7.4 Table 4 Charge Mode Specifications
| INVERTER MODEL | 8.2KW | 10.2KW |
|---|---|---|
| Charging Algorithm | 3-Step | |
| AC Charging Current (Max) | 140Amp | 140Amp |
| Bulk Charging Flooded Battery Voltage | 58.4 | |
| AGM / Gel Battery Voltage | 56.4 | |
| Floating Charging Voltage | 54Vdc | |
| Max. PV Array Power | PV1 Channel: 5400W | PV1 Channel: 5400W |
| PV2 Channel: 5400W | PV2 Channel: 5400W | |
| IMax.PV | PV1 Channel: 18A | PV2 Channel: 18A |
| Nominal PV Voltage | 360Vdc | |
| PV Array MPPT Voltage Range | 90Vdc~450Vdc | |
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| Max Charging Current (AC charger plus solar charger) | 160Amp | |
7.5 Table 5 Grid-Tie Operation
| INVERTER MODEL | 8.2KW | 10.2KW |
|---|---|---|
| Nominal Output Voltage | 220/230/240 VAC | |
| Feed-in Grid Voltage Range | 195~253VAC | |
| Feed-in Grid Frequency Range | 50±1Hz/60±1Hz | |
| Nominal Output Current | 35.6A | 44.3A |
| Power Factor Range | >0.99 | |
| Maximum Conversion Efficiency (DC/AC) | 98% | |
7.6 Table 6 General Specifications
| INVERTER MODEL | 8.2KW | 10.2KW |
|---|---|---|
| Safety Certification | CE | |
| Operating Temperature Range | -10°C to 50°C | |
| Storage temperature | -15°C~60°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Dimension (D*W*H), mm | 500*390*136mm | |
| Net Weight, kg | 14.5 | 14.7 |
8. User Tips
- When installing, ensure all components are securely connected and check polarity carefully to avoid damage.
- Regularly clean the anti-dust kit (monthly) to maintain optimal performance and extend the inverter's lifespan, especially in harsh environments.
- Familiarize yourself with the LCD display icons and settings to effectively monitor and configure your solar power system.
9. Warranty and Support
The PowMr 10.2KW Hybrid Solar Inverter comes with a 1-year warranty from the store.
For technical support or warranty claims, please contact PowMr directly:
- Email: support@powmr.com
- Web: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China
- Tel/Fax: +86 755-28219903
A user manual in PDF format is also available for download: User manual (PDF)
10. Frequently Asked Questions (FAQ)
- Q: Does this model have a PEN relay?
- A: The provided specifications do not explicitly mention a PEN relay. Please consult the detailed wiring diagrams in the manual or contact technical support for specific relay configurations.