LEIRONG LP8000

Contents

Leirong LP8000 High Flow Peristaltic Pump Instruction Manual

Model: LP8000-Brushed geared motor

1. Product Overview

The Leirong LP8000 is a high-flow DC motor peristaltic pump designed for precise and stable fluid transfer. It features a robust design with a waterproof pump head, low noise operation, and a double-bearing drive for extended life and reliability. The pump is suitable for a wide range of applications requiring accurate liquid dispensing.

Leirong LP8000 Peristaltic Pump

Figure 1: Leirong LP8000 Peristaltic Pump

Key Features:

  • High Flow Rate: Up to 8000 ml/min.
  • Low Noise Operation: Stable performance with minimal sound output.
  • Durable Drive: Double bearing drive for long service life and reliability.
  • Waterproof Pump Head: Designed for enhanced durability and safety.
  • Easy Tube Replacement: Compact card slot structure allows for quick and easy pump tube changes.
  • Machined Rollers: Small gap design prevents damage to the pump tube.
  • Transparent Shell: Allows visual inspection of the pump's operation.
  • Motor Options: Available with Stepper motor or DC motor (24V Brushed geared motor).

Product Video Overview:

Video 1: Overview of the LP8000 DC Motor Peristaltic Pump and its features.

2. Setup and Installation

This section provides instructions for the physical installation of the LP8000 peristaltic pump. Ensure all components are present and undamaged before proceeding.

2.1 Model Definition

The model number LP8000 is typically followed by codes indicating the motor type, tube material, and installation mode. For example, LP8000-G24-S73T-A.

  • G24: Refers to a 24V DC gear motor.
  • S: Indicates Silicone Tube; N: Indicates Norprene Tube.
  • 73T/82T: Specific tube species/dimensions.
  • A: Refers to Installation Mode A.
Model Definition Diagram

Figure 2: Diagram illustrating the model definition components.

2.2 Physical Installation (Mode A)

The pump is designed for easy integration into various systems. Follow the dimensions and opening sizes provided for secure mounting.

Installation Method A Diagram

Figure 3: Installation Mode A diagram with dimensions and opening size. The pump is mounted from the rear using screws.

Installation Steps:

  1. Prepare the mounting surface according to the provided dimensions (Figure 3).
  2. Ensure the opening size matches the diagram for proper fit.
  3. Secure the pump using appropriate M5 screws (equipped with M5x20 upper screw).
Product Size Diagram

Figure 4: Overall product dimensions (Length: 187.6mm, Width: 99.8mm, Height: 140.6mm).

2.3 Electrical Connection

The LP8000 pump operates on 24V DC. Connect the red wire to the positive (+) terminal and the black wire to the negative (-) terminal of your 24V DC power supply. Ensure the power supply is stable and provides the necessary current (e.g., 3A for 24V operation).

DC Motor with 24V label and carbon brush detail

Figure 5: DC Motor detail showing 24V rating and replaceable carbon brush.

3. Operation

Once installed and connected, the pump is ready for operation. The flow rate is determined by the pump tube type and the motor's rotational speed. The pump can be controlled via full speed or PWM speed regulation.

3.1 Flow Rate Parameters

The flow rate varies based on the pump tube material and dimensions (ID×OD). Refer to the table below for typical flow rates at 24V.

Table 1: Flow Rate Parameters (24V)
Tube Materials Silicone tube Norprene
Tube Species S73T S82T N73T N82T
ID×OD 9.6×16 12.7×19.1 9.6×16 12.7×19.1
Flow rate (ml/min) 5800 8000 4500 5300

Note: Suggested working conditions: Ambient temperature 0-50℃, relative humidity <80%. Data obtained from LEIRONG's laboratory and are for reference only. Flow rates may vary based on liquid properties, pressure, and pipeline length.

3.2 Applications

The LP8000 pump is versatile and can be used in various applications:

  • Beverage Machines (e.g., milk tea machines, tea drinking machines)
  • Soup Mixers
  • Filling Machines
  • Ice Cream Machines
  • Distributors
  • Water and Fertilizer Machines
  • Popcorn Machines
  • 3D Printing
  • Analytical Instruments
  • Inkjet Coding Printing
  • Water Quality Sampling
  • Hydroponics
  • Food Portioning
Collage of various applications for the peristaltic pump

Figure 6: Examples of LP8000 applications.

4. Maintenance

Regular maintenance, especially pump tube replacement, is crucial for optimal performance and longevity of your LP8000 peristaltic pump.

4.1 Pump Tube Selection and Life

The choice of pump tube material depends on the liquid being transferred and desired lifespan. The pump's design ensures that liquid only touches the pump tube, maintaining hygiene.

Pump Tube Selection Table

Figure 7: Table detailing pump tube materials, characteristics, temperature ranges, and approximate service life.

Pump Tube Life Testing Method: LP8000 peristaltic pump, speed: 430r/min, temperature 20 ℃, Test liquid: water, continuous operation test. The slower the rotational speed of the peristaltic pump, the longer the service life of the pump tube. The service life of the pump tube may vary depending on the operating conditions, pipeline pressure, and liquid corrosiveness.

4.2 Changing the Pump Tube

The LP8000 features a card slot structure for easy and stable pump tube replacement.

Steps for changing the pump tube

Figure 8: Visual guide for pump tube replacement.

  1. Unscrew the screws and carefully remove the pump cover.
  2. Remove the old pump tube from its position.
  3. Lock one joint of the new tube into the card slot. Rotate the sync disk to fit the tube, then clamp the other joint.
  4. Install the pump cover and secure it with screws to complete the tube change.

5. Troubleshooting

This section provides basic troubleshooting steps for common issues. For more complex problems, please contact customer support.

  • Pump not starting: Check electrical connections, ensure 24V DC power supply is active. Verify motor is correctly installed.
  • Reduced flow rate: Inspect pump tube for wear, kinks, or blockages. Ensure the correct tube species is used for the application. Check for proper seating of the pump tube in the card slot structure.
  • Unusual noise: Check for foreign objects in the pump head. Ensure the pump tube is correctly installed and not rubbing excessively. Verify the motor is securely mounted.
  • Leakage: Ensure pump tube connections are secure and the pump cover is properly tightened. Inspect the pump tube for any damage or punctures.

6. Specifications

Detailed technical specifications for the Leirong LP8000 Peristaltic Pump.

Table 2: General Specifications
Item Value
Model Number LP8000 DC motor
Brand Name LEIRONG
Origin China Mainland
Flow Range ≤8000 ml/min
Pressure Low Pressure
Power Source Electric
Motor Type Brushed geared motor
Control Mode Fullspeed / PWM speed regulation
Voltage 24V
Weight 1510g
Pump Tube Silicone tube / Norprene tube
Roller 3-roller
Noise ≤72dB
Power 72W
Certification CE, RoHS
Application Metering
Theory Rotary Pump
Structure Peristaltic Pump
Standard or Nonstandard Nonstandard

7. User Tips

Based on general usage and product characteristics, here are some tips for optimizing your experience with the LP8000 pump:

  • Tube Compatibility: Always ensure the selected pump tube material is compatible with the liquid being pumped to prevent degradation and ensure accurate flow.
  • Regular Inspection: Periodically check the pump tube for signs of wear, especially if pumping abrasive or corrosive liquids, to maintain consistent performance and prevent leaks.
  • Cleanliness: As liquid only contacts the pump tube, ensure the tubes are clean and sterile for applications requiring high hygiene standards.
  • Speed Control: Utilize PWM speed regulation for precise flow control in applications requiring variable dispensing rates.

8. Warranty and Support

LEIRONG is committed to providing stable and reliable fluid solutions. For any inquiries or support, please refer to the official channels.

  • Manufacturer: Lei Rong Fluid Tech (Shanghai) Co.,Ltd.
  • Certifications: CE, RoHS, ISO9001.
  • Contact Information: For technical support or service, please refer to the contact details provided on the official LEIRONG website or the product brochure.
  • User Manual (PDF): A detailed user manual in PDF format is available for download. View User Manual (PDF)

© 2023 LEIRONG. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.