JIKONG JK-LCD-7.0-TTL-P

Contents

JIKONG JK LCD Display 7.0 Inch Smart Touch Screen User Manual

Model: JK-LCD-7.0-TTL-P

For PB Series V19 Version Energy Storage Smart Inverter BMS JKBMS Accessory

1. Product Features and Appearance

1.1. Product Features

  • Support wide power supply working range: default 9~36V.
  • Display content: battery total voltage, battery power, single series voltage display.
  • Supports TTL/CMOS levels with a maximum baud rate of 921600bps.
  • Chinese/English/Thai/Vietnamese switchover is supported.
  • Support display interface customization: language customization, logo customization, interface customization.

1.2. Display Appearance

JIKONG 7.0 Inch LCD Display with 50cm cable and compatible BMS models
Figure 1: JIKONG 7.0 Inch LCD Display with 50cm cable, compatible with JK-PB1A16S10P V19, JK-PB1A16S15P V19, JK-PB2A16S15P V19, JK-PB2A16S20P V19, JK-PB2A16S30P V19.
Screenshot of the Battery Interface on the JIKONG display
Figure 2: Example of the Battery Interface showing voltage, current, capacity, and cell status.

1.3. External Interfaces

Back view of the 7.0 inch display showing connectors and dimensions
Figure 3: Back view of the 7.0 inch display showing Display Cable Connector, Switch Key Connector, and adhesive area. Dimensions are 187mm width, 120mm height.
  • User interface: Used for power supply and serial port signal connection, socket type HY2.0mm-6P vertical stick.
  • Key extension interface: Used to control BMS startup and shutdown, socket type GH1.25-6P vertical sticker.
  • TF Card Interface: Connects a TF card for offline download and interface translation.

Pin Definition (User Interface)

Number Name Definition Number Name Definition
1 K- Activation signal negative electrode 4 TXD Serial Port Output
2 K+ Activate the positive signal 5 RXD Serial Port Input
3 GND GND 6 VIN Power Supply

Pin Definition (Key Extension Interface)

Number Name Definition Number Name Definition
1 K- Activation signal negative electrode 4 TXD Serial Port Output
2 K+ Activate the positive signal 5 RXD Serial Port Input
3 GND GND 6 VIN Power Supply

2. Setup and Connection

This section outlines the basic steps for connecting your JIKONG LCD Display to a compatible BMS unit.

2.1. Unpacking

Carefully unpack the display and its accessories. The standard package includes:

Packing list showing the display, cable, and packing box
Figure 4: Packing List - 7.0 inch Display Screen, 50CM Cable, and Packing Box.

2.2. Cable Connection

The display connects to the BMS via a 50cm cable. Ensure the connectors are properly aligned before inserting to avoid damage.

JIKONG V19 PB Serial BMS connected to 7.0 Inch Touch Screen Display via UART Connector
Figure 5: JIKONG V19 PB Serial BMS connected to the 7.0 Inch Touch Screen Display via the UART Connector.

2.3. Visual Guide: Connection and Basic Operation

The following video demonstrates the connection process and basic user interface interaction. While the video features a 4.3-inch screen, the connection principles are similar for the 7.0-inch model.

Video 1: Demonstration of connecting the display to a BMS and basic touch screen operation (featuring a 4.3-inch model).

3. Operating Instructions

3.1. APP Operation Instructions

To configure the display via the JIKONG BMS APP, navigate to the "Parameter Setting" page and change the "Serial port 3 protocol" to "015-JK BMS PBxx SERIES LCD Protocol V1.0".

3.2. Display Interface Operation Description

3.2.1. Battery Interface

The battery string screen displays the current voltage and current of the battery string, the number of online battery packs, the charging and discharging status of the entire battery string, and the highest and lowest cell temperature.

Screenshot of the Battery Interface on the JIKONG display
Figure 6: Battery Interface showing overall battery status.

3.2.2. Battery Pack Interface

In parallel mode, by selecting the battery pack, you can display different battery pack design capacity, remaining capacity, charging and discharging status of each battery pack, voltage of each cell and other parameters. Up to 16 battery packs can be displayed.

Screenshot of the Battery Pack Interface showing individual battery pack details
Figure 7: Battery Pack Interface displaying detailed information for individual battery packs.

3.2.3. Protocol Selection Interface

Through protocol selection, you can select the corresponding 485 protocol and CAN protocol to ensure appropriate communication with your BMS.

Screenshot of the Protocol Selection Interface for RS485 and CAN protocols
Figure 8: Protocol Selection Interface for configuring RS485 and CAN communication.

4. Troubleshooting (Fault Alarm Interface)

When the alarm icon lights up on the display, the number shown below it indicates the fault code. Refer to the table below for fault code descriptions.

Fault Code Alarm Description
1 Single cell undervoltage alarm
2 Single cell overvoltage alarm
3 Overcurrent alarm
4 MOS overtemperature alarm
5 Battery overtemperature alarm
6 Short circuit alarm
7 Internal communication failure alarm
8 Balancing line resistance too high alarm
9 Cell string loss

5. Specifications

5.1. Overall Parameters

Parameter Data
Display category TFT
Display size 7-inch
Size/Resolution 1024*600
Backlight type/brightness LED / 200 cd/m²
Viewing Angle L/R/U/D 60°/60°/50°/40°

5.2. Power Supply

Parameter Min Max
Supply voltage (with power reverse protection) 9V 36V
Power dissipation 2.7W (12V@225mA)

5.3. Operating Environment and Reliability Parameters

Parameter Test Environment Min Typ Max Unit
Operating Temperature At 12V voltage, 60% humidity -10 - 60 °C
Storage Temperature - -20 - 70 °C
Operating Humidity 25°C 10% 60% 90% RH

5.4. Product Dimensions

Detailed dimensions of the 7.0 inch display
Figure 9: Detailed dimensions of the 7.0 inch display (187mm x 120mm overall, 154.08mm x 85.92mm LCD/VA area).

5.5. Cable Diagram

The standard cable length is 0.5 meters, and can be customized if necessary.

Diagram of the 50cm connection cable
Figure 10: Diagram of the 50cm connection cable.

6. Maintenance

To ensure the longevity and optimal performance of your JIKONG LCD Display, follow these general maintenance guidelines:

  • Cleaning: Use a soft, dry, lint-free cloth to clean the screen. For stubborn smudges, lightly dampen the cloth with water or a screen-safe cleaner. Avoid harsh chemicals or abrasive materials.
  • Environmental Conditions: Operate and store the display within the specified temperature and humidity ranges to prevent damage.
  • Connections: Periodically check all cable connections to ensure they are secure and free from corrosion or damage.
  • Software Updates: Keep the associated BMS APP and display firmware updated as recommended by JIKONG to benefit from performance improvements and new features.
  • Physical Protection: Avoid dropping the device or subjecting it to strong impacts. Protect the screen from scratches.

7. Certifications and Support

7.1. Product Certifications

The JIKONG BMS display holds the following certifications, ensuring compliance with international standards:

  • CE
  • FCC
  • RoHS
Image showing RoHS, FCC, and CE certifications
Figure 11: Product certifications including RoHS, FCC, and CE.

7.2. Further Documentation

A detailed PDF user manual is available for download, providing more in-depth information on operation and maintenance. You can access it via the following link: JIKONG 7-inch Display Screen Operation and Maintenance Manual (PDF).

7.3. Technical Support

For technical assistance, warranty claims, or any other inquiries, please contact JIKONG customer support through their official channels or the vendor from whom you purchased the product.