1. Product Features and Appearance
1.1. Product Features
- Support wide power supply working range: default 9~36V.
- Display content: battery total voltage, battery power, single series voltage display.
- Supports TTL/CMOS levels with a maximum baud rate of 921600bps.
- Chinese/English/Thai/Vietnamese switchover is supported.
- Support display interface customization: language customization, logo customization, interface customization.
1.2. Display Appearance
1.3. External Interfaces
- User interface: Used for power supply and serial port signal connection, socket type HY2.0mm-6P vertical stick.
- Key extension interface: Used to control BMS startup and shutdown, socket type GH1.25-6P vertical sticker.
- TF Card Interface: Connects a TF card for offline download and interface translation.
Pin Definition (User Interface)
| Number | Name | Definition | Number | Name | Definition |
|---|---|---|---|---|---|
| 1 | K- | Activation signal negative electrode | 4 | TXD | Serial Port Output |
| 2 | K+ | Activate the positive signal | 5 | RXD | Serial Port Input |
| 3 | GND | GND | 6 | VIN | Power Supply |
Pin Definition (Key Extension Interface)
| Number | Name | Definition | Number | Name | Definition |
|---|---|---|---|---|---|
| 1 | K- | Activation signal negative electrode | 4 | TXD | Serial Port Output |
| 2 | K+ | Activate the positive signal | 5 | RXD | Serial Port Input |
| 3 | GND | GND | 6 | VIN | Power Supply |
2. Setup and Connection
This section outlines the basic steps for connecting your JIKONG LCD Display to a compatible BMS unit.
2.1. Unpacking
Carefully unpack the display and its accessories. The standard package includes:
2.2. Cable Connection
The display connects to the BMS via a 50cm cable. Ensure the connectors are properly aligned before inserting to avoid damage.
2.3. Visual Guide: Connection and Basic Operation
The following video demonstrates the connection process and basic user interface interaction. While the video features a 4.3-inch screen, the connection principles are similar for the 7.0-inch model.
Video 1: Demonstration of connecting the display to a BMS and basic touch screen operation (featuring a 4.3-inch model).
3. Operating Instructions
3.1. APP Operation Instructions
To configure the display via the JIKONG BMS APP, navigate to the "Parameter Setting" page and change the "Serial port 3 protocol" to "015-JK BMS PBxx SERIES LCD Protocol V1.0".
3.2. Display Interface Operation Description
3.2.1. Battery Interface
The battery string screen displays the current voltage and current of the battery string, the number of online battery packs, the charging and discharging status of the entire battery string, and the highest and lowest cell temperature.
3.2.2. Battery Pack Interface
In parallel mode, by selecting the battery pack, you can display different battery pack design capacity, remaining capacity, charging and discharging status of each battery pack, voltage of each cell and other parameters. Up to 16 battery packs can be displayed.
3.2.3. Protocol Selection Interface
Through protocol selection, you can select the corresponding 485 protocol and CAN protocol to ensure appropriate communication with your BMS.
4. Troubleshooting (Fault Alarm Interface)
When the alarm icon lights up on the display, the number shown below it indicates the fault code. Refer to the table below for fault code descriptions.
| Fault Code | Alarm Description |
|---|---|
| 1 | Single cell undervoltage alarm |
| 2 | Single cell overvoltage alarm |
| 3 | Overcurrent alarm |
| 4 | MOS overtemperature alarm |
| 5 | Battery overtemperature alarm |
| 6 | Short circuit alarm |
| 7 | Internal communication failure alarm |
| 8 | Balancing line resistance too high alarm |
| 9 | Cell string loss |
5. Specifications
5.1. Overall Parameters
| Parameter | Data |
|---|---|
| Display category | TFT |
| Display size | 7-inch |
| Size/Resolution | 1024*600 |
| Backlight type/brightness | LED / 200 cd/m² |
| Viewing Angle L/R/U/D | 60°/60°/50°/40° |
5.2. Power Supply
| Parameter | Min | Max |
|---|---|---|
| Supply voltage (with power reverse protection) | 9V | 36V |
| Power dissipation | 2.7W (12V@225mA) | |
5.3. Operating Environment and Reliability Parameters
| Parameter | Test Environment | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Operating Temperature | At 12V voltage, 60% humidity | -10 | - | 60 | °C |
| Storage Temperature | - | -20 | - | 70 | °C |
| Operating Humidity | 25°C | 10% | 60% | 90% | RH |
5.4. Product Dimensions
5.5. Cable Diagram
The standard cable length is 0.5 meters, and can be customized if necessary.
6. Maintenance
To ensure the longevity and optimal performance of your JIKONG LCD Display, follow these general maintenance guidelines:
- Cleaning: Use a soft, dry, lint-free cloth to clean the screen. For stubborn smudges, lightly dampen the cloth with water or a screen-safe cleaner. Avoid harsh chemicals or abrasive materials.
- Environmental Conditions: Operate and store the display within the specified temperature and humidity ranges to prevent damage.
- Connections: Periodically check all cable connections to ensure they are secure and free from corrosion or damage.
- Software Updates: Keep the associated BMS APP and display firmware updated as recommended by JIKONG to benefit from performance improvements and new features.
- Physical Protection: Avoid dropping the device or subjecting it to strong impacts. Protect the screen from scratches.
7. Certifications and Support
7.1. Product Certifications
The JIKONG BMS display holds the following certifications, ensuring compliance with international standards:
- CE
- FCC
- RoHS
7.2. Further Documentation
A detailed PDF user manual is available for download, providing more in-depth information on operation and maintenance. You can access it via the following link: JIKONG 7-inch Display Screen Operation and Maintenance Manual (PDF).
7.3. Technical Support
For technical assistance, warranty claims, or any other inquiries, please contact JIKONG customer support through their official channels or the vendor from whom you purchased the product.