1. Introduction
The Siglent SDS800X HD series digital storage oscilloscopes are designed for high-performance test applications, offering a bandwidth range of 70 MHz to 200 MHz. These oscilloscopes are suitable for testing and debugging a wide range of precision electronic equipment. The series supports two to four analog channels with optional expansion to meet diverse test requirements. With a sampling rate of up to 2 GSa/s and a waveform capture rate of 500,000 wfm/s, the series ensures fast capture of transient signals. The 12-bit vertical resolution combined with the 100 Mpts storage depth provides clear and detailed waveform data, making it a powerful assistant for engineers in circuit design and troubleshooting.

Figure 1.1: Siglent SDS804X HD Digital Storage Oscilloscope in use.
2. Setup
2.1 Unpacking and Inspection
Carefully unpack the oscilloscope and all accessories. Verify that all items listed below are present and in good condition. If any item is missing or damaged, contact your supplier immediately.

Figure 2.1: Standard accessories included with the oscilloscope.
- Host: The main oscilloscope unit.
- Passive Probe (1 set/Channel): For signal input.
- Power Cord * 1: For connecting the oscilloscope to mains power.
- USB Cable * 1: For connecting to a computer or other USB devices.
- Guidelines & Certificate * 1: Documentation and quality assurance.
2.2 Power Connection
- Ensure the oscilloscope's power switch is in the OFF position.
- Connect the provided power cord to the AC power input on the rear panel of the oscilloscope.
- Plug the other end of the power cord into a grounded AC power outlet.
2.3 Initial Power On
- Press the power button located on the front panel to turn on the oscilloscope.
- The device will perform a self-test and display the boot screen.
- Once the boot sequence is complete, the main waveform display will appear.
2.4 Probe Connection
- Connect the passive probes to the BNC input connectors on the front panel (CH1, CH2, CH3, CH4).
- Ensure the probe is securely twisted onto the BNC connector.
- For accurate measurements, it is recommended to compensate the probes before use. Refer to the full user manual for probe compensation procedures.
2.5 Connecting External Devices
The oscilloscope features USB 2.0 Host ports for connecting external devices such as a USB mouse, keyboard, or USB storage devices. A USB 2.0 Device port is available for connecting the oscilloscope to a PC. The 10M/100M LAN port allows for network connectivity and remote control via a web server.
Video 2.1: Product demonstration showing unboxing, power-on, and basic operation.
3. Operating Instructions
3.1 User Interface and Controls
The SDS800X HD series features a 7-inch capacitive touch screen with 1024x600 resolution, providing an intuitive user experience. Physical knobs and buttons are also available for precise control.
- Touch Screen: Supports multi-touch gestures for zooming and scaling waveforms.
- Vertical Controls: Knobs and buttons for adjusting vertical scale (Volts/div) and position for each channel.
- Horizontal Controls: Knobs for adjusting time base (Sec/div) and horizontal position.
- Trigger Controls: Buttons and knobs for setting trigger level, mode (Auto, Normal, Single), and type.
- Quick Action Buttons: Such as Run/Stop, Auto Setup, Default Setup.
3.2 Basic Waveform Display and Adjustment
- Auto Setup: Press the 'Auto Setup' button for the oscilloscope to automatically adjust vertical, horizontal, and trigger settings to display a stable waveform.
- Adjusting Vertical Scale: Rotate the 'Volts/div' knob for the desired channel to change the vertical sensitivity.
- Adjusting Horizontal Scale: Rotate the 'Sec/div' knob to change the time base.
- Positioning Waveforms: Use the 'Position' knobs for vertical and horizontal adjustments to move the waveform on the screen.
3.3 Measurements and Analysis
The oscilloscope offers a wide range of measurement and analysis tools:
- Parameter Measurements: Includes over 50 different types of measurements (horizontal, vertical, miscellaneous, and CH delay). Measurements can be performed within a specified gate period.
- Parameter Statistics: Displays current, maximum, minimum, value, standard deviation, and mean value. A histogram is available to show the probability distribution of a parameter. Trend and Track functions are available for parameter value vs. time.
- History Mode: Records up to 80,000 frames of waveforms, allowing playback to observe unusual events.
- Sequence Mode: Segmented memory stores up to 80,000 segments, capturing fast events with minimal dead time.

Figure 3.1: Parameter measurements and statistics functions.

Figure 3.2: History Mode and Sequence Mode for waveform capture.
3.4 Trigger Functions
The SDS800X HD series supports a variety of trigger types to capture specific events:
- Edge, Slope, Pulse width, Window, Runt, Interval, Dropout, Pattern, Video, Qualified, Nth edge, Delay, Setup/Hold time, and Serial Trigger.

Figure 3.3: High waveform update rate, deep record length, and trigger options.
3.5 Advanced Features
- 12-bit High Resolution: Provides enhanced vertical resolution for observing waveform overall and details simultaneously.
- Low Noise Floor: Only 70 µVrms at 200 MHz bandwidth.
- 0.5% DC Gain Accuracy.
- Optional Font Size: To meet different observation needs.
- Search and Navigate: Events flagged by the user can be recalled automatically.
- Serial Bus Decode: Supports I2C, SPI, UART, CAN, LIN protocols, displaying decoded characters in a tabular form.
- Hardware-based High-Speed Mask Test: Performs up to 80,000 Pass/Fail decisions each second using user-defined test templates.
- Advanced Math Functions: Includes FFT, integration, differentiation, square root, and more. Formula Editor is available for complex operations.
- Optional Modules: Bode Plot, Power Analysis, Digital Channels (MSO), and USB Arbitrary Waveform Generator (AWG).

Figure 3.4: Comparison of 8-bit and 12-bit vertical resolution.

Figure 3.5: User interface and font size options.

Figure 3.6: Search, Serial Bus Decode, and Mask Test functions.

Figure 3.7: Optional Bode Plot, Power Analysis, Digital Channels/MSO, and USB AWG module.
4. Maintenance
4.1 Cleaning
To clean the oscilloscope, use a soft cloth dampened with a mild detergent solution. Do not use abrasive cleaners or solvents that could damage the instrument's casing or screen. Ensure the device is powered off and unplugged before cleaning.
4.2 Storage
When not in use, store the oscilloscope in a dry, dust-free environment away from direct sunlight and extreme temperatures. Use the original packaging or a suitable carrying case for protection during transport.
4.3 Calibration
For optimal performance and measurement accuracy, periodic calibration by qualified personnel is recommended. Refer to the full user manual or contact Siglent support for calibration intervals and procedures.
5. Troubleshooting
This section provides basic troubleshooting steps for common issues. For more detailed troubleshooting guides and error codes, please refer to the comprehensive user manual PDF available for download.
- No Power: Check the power cord connection to both the oscilloscope and the AC outlet. Ensure the power outlet is functional.
- No Waveform Display: Check probe connections to the input channels and the circuit under test. Ensure the input signal is within the oscilloscope's measurement range. Try using the 'Auto Setup' function.
- Distorted Waveform: Verify probe compensation. Check the probe's attenuation setting (1X/10X) matches the oscilloscope's channel setting. Ensure the signal source is stable.
- Unresponsive Touch Screen: Try restarting the oscilloscope. If the issue persists, use an external mouse for navigation.
For further assistance, consult the official user manual PDF: Siglent SDS800X HD Series User Manual (PDF)
6. Specifications
The following table outlines the key specifications for the Siglent SDS800X HD series oscilloscopes.

Figure 6.1: Key performance specifications for SDS800X HD series.

Figure 6.2: Detailed function introduction and parameters.
| Feature | Specification |
|---|---|
| Vertical Resolution | 12-bit |
| Screen Size | 7-inch capacitive touch screen |
| Screen Resolution | 1024x600 |
| Interfaces | SBUS, USB 2.0 Host x2, USB 2.0 Device, 10M/100M LAN, Auxiliary Output (TRIG OUT, PASS/FAIL) |
| Dimensions (L*W*H) | 312mm * 133mm * 151mm |
| Net Weight | 2.6kg |
| Gross Weight | 3.8kg |
7. Warranty and Support
7.1 Warranty Information
This Siglent oscilloscope comes with a 2-year warranty from the date of purchase. Please retain your proof of purchase for warranty claims. The warranty covers defects in materials and workmanship under normal use.
7.2 Technical Support
For technical inquiries, troubleshooting assistance, or service requests, please contact your authorized Siglent distributor or the seller. Provide your product model and serial number for faster service.
8. User Tips
- Power Plug Compatibility: The power cable provided may vary by region. If the plug type is not compatible with your local outlets, a suitable adapter can be used.
- Display Size: The oscilloscope features a 7-inch display, offering a clear view of waveforms and settings.
- Probe Compensation: Always compensate your probes before making critical measurements to ensure accuracy. Refer to the full user manual for detailed instructions.
- External Peripherals: Utilize the USB ports to connect a mouse and keyboard for enhanced navigation and data entry, especially when performing complex analysis or data logging.