1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your Haier Central Air Conditioning Wire Controller. This device is designed to provide manual control over multi-connected duct central air conditioning systems in a home environment. Please read this manual thoroughly before installation and use to ensure proper function and safety.

Figure 1: Front view of the Haier YR-E17 Wire Controller
2. Safety Information
- Installation should only be performed by qualified personnel to prevent electrical shock or damage to the unit.
- Ensure the power supply to the central air conditioning unit is disconnected before performing any installation or wiring.
- Do not expose the controller to water or excessive moisture.
- Do not attempt to repair or modify the unit yourself. Contact a qualified technician for service.
3. Package Contents
Verify that all items are present in the package:
- Haier Central Air Conditioning Wire Controller (Model YR-E17 or 0150401331J)
- Mounting screws (if included)
4. Setup and Installation
This wire controller is designed for wall mounting and requires connection to your central air conditioning system. Professional installation is highly recommended.
4.1. Physical Installation
- Prepare the Mounting Location: Choose a suitable indoor wall location, away from direct sunlight, drafts, or heat sources, and at an appropriate height for easy access.
- Access Wiring Terminals: Carefully remove the front panel of the controller to expose the mounting holes and wiring terminals. The video below demonstrates how to access the internal components.
- Mount the Controller: Use appropriate screws to securely mount the back plate of the controller to the wall. Ensure it is level.
Video 1: Product demonstration showing removal of the back panel to access wiring.
4.2. Wiring
The controller draws power and communicates with the central air conditioning unit via its wiring connections. Refer to the wiring diagram provided with your central AC unit and the labels on the controller's circuit board for correct connections. The back of the controller features a dedicated connector for this purpose.

Figure 2: Detailed back view showing wiring terminal area (Model YR-E17 shown)
- Identify the communication and power wires from your central air conditioning system.
- Connect these wires to the corresponding terminals on the controller's circuit board. Pay close attention to polarity and terminal labels (e.g., R12, TXD, R13, GND, DRIVE).
- Once wiring is complete, carefully reattach the front panel to the controller.
4.3. Initial Power-Up
After installation and wiring are complete, restore power to your central air conditioning system. The controller's display should illuminate, indicating it is receiving power and ready for operation.
5. Operating Instructions
The Haier Wire Controller provides a simple interface for managing your central air conditioning system.
5.1. Basic Controls
The front of the controller features a display screen and a single circular button, which serves as the primary interface for navigation and selection.
- Power On/Off: Press and hold the circular button for a few seconds to turn the unit on or off.
- Mode Selection: Short press the circular button to cycle through available operating modes (e.g., Cool, Heat, Fan, Auto).
- Temperature Adjustment: When a temperature setting is displayed, rotate the circular button (if it has a rotary function) or press it repeatedly to adjust the desired temperature.
- Fan Speed: In fan mode, use the circular button to select desired fan speed (e.g., Low, Medium, High, Auto).
5.2. Display Information
The display screen shows current operating status, including:
- Current Room Temperature
- Set Temperature
- Operating Mode Icon
- Fan Speed Indicator
- Error Codes (if any)
6. Maintenance
To ensure optimal performance and longevity of your wire controller, follow these simple maintenance guidelines:
- Cleaning: Regularly wipe the surface of the controller with a soft, dry cloth. Do not use abrasive cleaners, solvents, or chemical sprays, as these can damage the display or casing.
- Avoid Obstructions: Ensure that the air vents on the sides or back of the controller are not blocked, as this can affect temperature sensing.
7. Troubleshooting
If you encounter issues with your wire controller, try the following basic troubleshooting steps:
- No Display/No Power: Check if the central air conditioning unit has power. Verify all wiring connections are secure and correct.
- Incorrect Temperature Reading: Ensure the controller is not exposed to direct heat sources, cold drafts, or excessive moisture.
- Controller Not Responding: Try turning off the power to the central AC unit for a few minutes, then restore power to reset the controller.
- System Not Responding to Commands: Verify that the central AC unit itself is functioning correctly. Check for any error codes displayed on the controller.
If the problem persists after attempting these steps, contact a qualified HVAC technician for assistance.
8. Specifications
| Feature | Specification |
|---|---|
| Model Numbers | YR-E17, 0150401331J |
| Type | Air Conditioning Fitting, Air Conditioner Parts |
| Application | Home |
| Certification | CE |
| Origin | Mainland China |
| Electric | No (Power supplied by AC unit) |
| High-concerned chemical | None |
| Package Length | 35 cm |
| Package Width | 15 cm |
| Package Height | 10 cm |
| Package Weight | 1.9 kg |
9. User Tips
- Language Settings: Upon initial setup or if the display language is unfamiliar, check the controller's settings menu (if available) to select your preferred language.
10. Warranty and Support
For warranty information, please refer to the terms and conditions provided by the seller, Qiwen Accessories Store, at the time of purchase. For technical support or service inquiries, please contact the seller or a certified Haier service center.