1. Introduction
The SUMRY MPS-VIII ECO Series is a multi-functional hybrid solar inverter designed to combine the functions of an inverter, solar charger, and battery charger to offer uninterruptible power support. This series includes models with power ratings of 3.6kW, 4.2kW, and 6.2kW, operating at 24V or 48V DC and providing 230VAC output. It features a pure sine wave output, high PV input voltage range, and built-in MPPT solar charge controller, making it suitable for various on-grid and off-grid applications.


2. Safety Information
Please read all instructions and cautionary markings on the unit and in this manual before installation and operation. This inverter is designed with multiple protection features to ensure safe operation. However, improper installation or use can lead to hazards.
- Ensure all wiring is performed by qualified personnel.
- Do not disassemble the inverter. There are no user-serviceable parts inside.
- Keep the inverter away from flammable materials and moisture.
- Ensure proper ventilation around the inverter to prevent overheating.
- Verify battery voltage and polarity before connecting to the inverter.
- Always disconnect all power sources (PV, AC, Battery) before performing any maintenance or wiring.

3. Product Overview
3.1 Physical Dimensions and Features
The inverter features a compact design with dimensions of 420mm (D) x 310mm (W) x 110mm (H).

3.2 Display and Controls
The inverter is equipped with an LCD display and function buttons for monitoring and configuration. LED indicators provide quick status updates.

LED Indicator Messages:
| LED Indicator | State | Messages |
|---|---|---|
| INV/AC | Solid On | Output is powered by utility in Line mode. |
| Green | Output is powered by battery or PV in battery mode. | |
| CHG | Solid On | Battery is fully charged. |
| Green | Battery is charging. | |
| FAULT | Solid On | Fault occurs in the inverter. |
| Red | Warning condition occurs in the inverter. |
Function Keys:
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4. Specifications
The following table details the technical specifications for the SUMRY MPS-VIII ECO Series Hybrid Solar Inverter models.



| Feature | MPS-VIII 3.6KW | MPS-VIII 4.2KW | MPS-VIII 6.2KW |
|---|---|---|---|
| General | |||
| Phase | 1-phase | ||
| Dimension (D*W*H) | 420*350*110 mm | ||
| Net Weight | 8.0 kgs | 8.0 kgs | 8.9 kgs |
| Operating Temperature | -10°C ~ 50°C | ||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | ||
| Compliance Safety | CE | ||
| PV Input (DC) | |||
| Nominal DC Voltage/Max DC Voltage | 360/500 VDC | ||
| Start-up Voltage/Initial Feeding Voltage | 90VDC/120VDC | ||
| MPPT Voltage Range | 60-450 VDC | ||
| Maximum Input Current | 1/18 A | 1/22 A | 1/18 A, 1/22 A |
| Max PV Input Power | 6200 W | 6200 W | 6500 W |
| Grid-Tie Operation | |||
| Rated Output Power | 3600W/3600VA | 4200W/4200VA | 6200W/6200VA |
| Nominal Output Voltage | 220/230/240 VAC | ||
| Output Voltage Range | 195-253 VAC | ||
| Nominal Output Current | 15.7 A | 18.2 A | 27.0 A |
| Power Factor | >0.99 | ||
| Max Conversion Efficiency (DC/AC) | 98% | ||
| Two-Load Output Power | |||
| Full Load | 3600 W | 4200 W | 6200 W |
| Maximum Main Load | 3600 W | 4200 W | 6200 W |
| Max Second Load (battery mode) | 1200 W | 1400 W | 2067 W |
| Max Load Cut Off Voltage (24V/48V) | 26VDC/52VDC | 26VDC/52VDC | 26VDC/52VDC |
| Max Load Return Voltage (24V/48V) | 27VDC/54VDC | 27VDC/54VDC | 27VDC/54VDC |
| Off-Grid Operation | |||
| AC Start-up Voltage/Auto Restart Voltage | 120-140VAC/180VAC | ||
| Acceptable Input Voltage Range | 90-280VAC or 170-280VAC | ||
| Maximum AC Input Current | 21.1 A | 24.7 A | 36.4 A |
| Frequency Range | 59-61 Hz | ||
| Nominal Output Voltage (Battery Mode) | 220/230/240 VAC | ||
| Output Waveform (Battery Mode) | Pure sine wave | ||
| Efficiency (DC to AC) | 94% | ||
| Battery Charger | |||
| Nominal DC Voltage | 24VDC | 48VDC | 24VDC, 48VDC |
| Maximum Solar Charging Current | 120 A | 80 A | 120 A, 80 A |
| Maximum AC Charging Current | 100 A | ||
| Maximum Solar+AC Charging Current | 120 A | 80 A | 120 A, 80 A |
| Interface | |||
| Communication Port | RS232/RS485/WIFI/GPRS/LITHIUM BATTERY | ||
5. Installation and Setup
Proper installation is critical for the safe and efficient operation of your SUMRY Hybrid Solar Inverter. Ensure all local electrical codes are followed.
5.1 System Architecture
The inverter can be integrated into various solar power systems, including off-grid and on-grid configurations with or without battery backup.


5.2 Connection Ports
Identify the various connection ports on the rear panel of the inverter for proper wiring.

- AC Input: Connect the utility grid or generator AC power source.
- Main Output: Connect to your primary AC loads.
- Second Output: Connect to secondary AC loads, if applicable.
- Battery Communication RS-485 Port: For communication with compatible battery management systems (BMS).
- WIFI Communication RS-232 Port: For WiFi module connection and remote monitoring.
- PV Input: Connect the solar panel array. Ensure correct polarity and voltage within specified limits.
- Battery Input: Connect the battery bank. Ensure correct polarity and voltage (24V or 48V).
5.3 Battery Compatibility
The inverter is compatible with multiple battery types, offering flexibility for your energy storage needs.

- Flooded Batteries
- Gel Batteries
- LiFePO4 Batteries (Lithium Iron Phosphate)
- Lithium Batteries
- AGM/Sealed Batteries
- User Custom Battery settings
6. Operating Instructions
Once installed, the inverter can be operated and monitored via its LCD display and function buttons. For detailed settings and monitoring, refer to the specific communication software or app.
6.1 Powering On/Off
- To Power On: Ensure all connections are secure. Turn on the battery breaker first, then the PV array breaker, and finally the AC input breaker (if connected to grid/generator). The inverter will initiate its startup sequence.
- To Power Off: Reverse the power-on sequence. First, turn off the AC input breaker, then the PV array breaker, and finally the battery breaker.
6.2 Monitoring and Settings
Use the function keys (ESC, UP, DOWN, ENTER) to navigate through the LCD display menus to view operational data and adjust settings. Refer to the LED Indicator Messages and Function Keys table in Section 3.2 for basic understanding.
For advanced monitoring and configuration, connect to the inverter via the RS485 (BMS) or RS232 (WiFi) communication ports using appropriate software or mobile applications.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter.
- Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris.
- Connection Checks: Annually inspect all electrical connections (PV, battery, AC) for tightness and signs of corrosion.
- Environment: Ensure the operating environment remains within specified temperature and humidity ranges.
- Firmware Updates: Check the manufacturer's website for any available firmware updates to improve performance or add features.
8. Troubleshooting
If the inverter is not operating as expected, refer to the LED indicators (Section 3.2) for fault or warning messages. Common issues and basic troubleshooting steps are listed below:
- No Power/Display Off: Check all power connections (battery, AC input). Ensure battery voltage is within the operating range.
- Fault LED On: Refer to the LCD display for specific error codes. This usually indicates an internal fault or a severe external condition. Disconnect all power sources and contact support if the fault persists after restarting.
- Warning LED Flashing: Indicates a non-critical condition that may affect performance. Check for environmental issues (overheating) or input voltage fluctuations.
- No AC Output: Verify AC output connections. Check if the inverter is in a fault state. Ensure sufficient PV input or battery charge.
- Battery Not Charging: Check PV input connections and voltage. Verify battery settings are correct for the connected battery type.
For complex issues, it is recommended to contact qualified technical support.
9. User Tips
- Voltage Compatibility: The inverter's nominal output voltage is 220/230/240VAC. While some systems might use 110V, this inverter is primarily designed for higher voltage AC systems. Ensure your load voltage matches the inverter's output.
- Battery Selection: Utilize the inverter's compatibility with various battery types (Flooded, Gel, LiFePO4, Lithium, AGM) to select the best option for your specific application and budget. Ensure the battery voltage (24V or 48V) matches your inverter model.
- Monitoring: Take advantage of the dual communication ports (RS485 for BMS, RS232 for WiFi) to set up remote monitoring. This allows you to track performance and receive alerts, optimizing your system's efficiency.
10. Warranty and Support
The SUMRY MPS-VIII ECO Series Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use.

For technical support, warranty claims, or service inquiries, please contact SUMRY customer service. Expect a response within 24 hours for your queries.
Manufacturer: Shenzhen Sunray Power Co., Ltd.
Brand: SUMRY
Store: SUMRY Inverter Store