Sugon 3005PM / 3010PM

Contents

Sugon 3005PM / 3010PM DC Power Supply User Manual

Model: 3005PM / 3010PM

Brand: Sugon

1. Introduction

This manual provides detailed instructions for the operation and maintenance of the Sugon 3005PM and 3010PM DC Power Supplies. These professional-grade power sources are designed for applications requiring precise voltage and current control, featuring multiple output channels, USB charging ports, and advanced protection mechanisms. Please read this manual thoroughly before operating the device to ensure safe and efficient use.

2. Safety Information

  • Always connect the power supply to a grounded outlet.
  • Do not operate the device in wet or damp conditions.
  • Ensure proper ventilation to prevent overheating. The unit features a temperature-controlled fan for real-time heat dissipation.
  • Do not open the casing; refer servicing to qualified personnel.
  • Verify voltage and current settings before connecting to a device to prevent damage.
  • Utilize the overcurrent and overvoltage protection features to safeguard connected equipment.

3. Product Overview

3.1 Front Panel Controls and Indicators

Front panel diagram of Sugon DC Power Supply with labels for controls and displays.
Figure 1: Front Panel Layout
  • Digital Display: Shows Power, Current, and Voltage readings.
  • Status Indicator: Lights to show operational status.
  • Voltage Adjustment Knob: Used to set the output voltage.
  • Current Adjustment Knob: Used to set the output current.
  • 8.4V-30V Limited Switch: Restricts maximum voltage output to 8.4V (on some models).
  • Constant Current (C.C.) / Constant Voltage (C.V.) Mode Button: Toggles between constant current and constant voltage modes.
  • ONCE OCP Button (Once Overcurrent Protection): Activates single-event overcurrent protection.
  • CONT OCP Button (Continuous Overcurrent Protection): Activates continuous overcurrent protection.
  • M1, M2, M3, M4 Buttons: Memory/Save keys for storing and recalling settings.
  • Power Switch: Main power control.
  • Positive and Negative Output Ports: Main DC power output terminals (0V-30V).
  • Adjustable USB Output Ports (1-6): USB ports with adjustable voltage output (0V-30V).
  • Fixed 5V/2A USB Output Ports (A, B): Standard 5V USB charging ports.

3.2 Rear Panel Components

Rear panel diagram of Sugon DC Power Supply with labels for cooling fan, AC power input, and fuse box.
Figure 2: Rear Panel Layout
  • Cooling Fan: Ensures efficient heat dissipation during operation.
  • AC Power Input: Connects to the main power supply.
  • Fuse Box: Contains the protective fuse for the unit.

4. Setup

  1. Unpacking: Carefully remove the power supply from its packaging. Inspect for any signs of damage.
  2. Placement: Place the unit on a stable, level surface with adequate ventilation around the cooling fan. Ensure no obstructions block the air vents.
  3. Power Connection: Connect the provided AC power cord to the AC power input on the rear panel and then to a suitable grounded electrical outlet.
  4. Initial Power On: Press the main power switch on the front panel. The digital display should illuminate.

5. Operating Instructions

5.1 Basic Operation (Voltage and Current Regulation)

  1. Adjusting Voltage: Twist the "V" voltage knob to adjust the output voltage. Press the "V" voltage knob to cycle through the digits; the corresponding flashing digit can then be adjusted by twisting the knob.
  2. Adjusting Current: Similarly, twist the "A" current knob to set the output current limit. Press the "A" current knob to select digits for adjustment.
  3. Connecting Load: Connect your device to the positive (red) and negative (black) output ports using appropriate leads.

5.2 Protection Modes

  • Continuous Overcurrent Protection (CONT OCP): Press the CONT OCP button. The indicator light will turn on. In this mode, if an overcurrent condition occurs, the power supply will automatically restore output once the condition is resolved. This is the most commonly used protection method.
  • Once Overcurrent Protection (ONCE OCP): Press the ONCE OCP button. The indicator light will turn on. This mode is suitable for circuits sensitive to multiple current surges. After a single overcurrent event, the indicator flashes, and the power supply stops outputting until the ONCE OCP button is pressed again to reset the function.
  • Constant Current Mode: Press the C.C. button. Both OCP indicators will turn off. In this mode, the power supply maintains a constant current output without overcurrent protection.
  • 8.4V Limited Function: (Available on some models) Use the 8.4V-30V limited switch to restrict the maximum voltage output to 8.4V, minimizing potential damage from operational errors.
Close-up of the 8.4V-30V output transfer switch.
Figure 3: 8.4V-30V Output Transfer Switch

5.3 USB Output Ports

  • Adjustable USB Output (Ports 1-6): These ports provide adjustable voltage output from 0V to 30V. When using these, ensure you set a safe current and voltage range. The output from these ports mirrors the main positive and negative output terminals.
  • Fixed 5V/2A USB Output (Ports A, B): These ports provide a standard 5V, 2A output, suitable for charging mobile phones and other 5V devices.
Image showing a phone and battery charging from the USB ports of the power supply.
Figure 4: Device Charging via USB Ports

5.4 Memory/Save Function

To store current settings (current, voltage, OCP mode, C.C. mode):

  1. Press and hold one of the channel buttons (M1, M2, M3, or M4) for two seconds.
  2. Release the button after hearing two beeps. The settings are now stored in that memory slot.

To recall stored data, press the corresponding memory button (M1-M4) once.

5.5 Display Brightness Adjustment

Image demonstrating display brightness adjustment on the Sugon DC Power Supply.
Figure 5: Display Brightness Adjustment

In normal use state:

  1. Press and hold the memory buttons M1 and M2 simultaneously.
  2. The display will show "0000" in the voltage position, and the current display will show the current brightness level.
  3. Rotate the current knob to adjust the brightness.
  4. Once the desired brightness is set, press the current knob to save and exit.

5.6 Buzzer Settings

In the locked state, long press the current button to toggle the buzzer sound on or off.

5.7 Restore Factory Settings

In the locked state:

  1. Press and hold the memory keys M1 and M2 simultaneously.
  2. After the buzzer rings for a long time and "5E" is displayed, the factory setting parameters for memory keys M1, M2, M3, and M4 will be restored.

5.8 Video Demonstration

Video 1: Product demonstration showing phone charging, voltage/current adjustment, and output connection. The device functions as a rework and soldering station, features a brushless fan for soft air output, supports T12 heating core, and offers precise digital adjustment.

6. Specifications

FeatureSpecification
TypeDC Power Supply
Model3005PM or 3010PM
Voltage Output0-30V
Current Output0-5A (3005PM) / 0-10A (3010PM)
Adjustable USB Output6 ports, 0-30V adjustable
Fixed USB Output2 ports, 5V/2A
DisplayLED Four-digit display (Voltage, Current, Power)
Protection FeaturesOvervoltage (OVP), Overcurrent (OCP), Overload (OPP), High Temperature Protection, Fuse Protection
CoolingTemperature Control Fan
Memory Functions4 stored memories (M1-M4)
MaterialStainless Steel (Casing)
ApplicationComputer Tool Kit, Electrical DIY Supplies, Phone Repair, Laboratory Use

7. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the exterior of the unit. Do not use liquid cleaners or solvents.
  • Ventilation: Regularly check that the cooling fan and vents are free from dust and obstructions to ensure optimal heat dissipation.
  • Fuse Replacement: If the unit fails to power on, check the fuse in the fuse box on the rear panel. Replace with a fuse of the same type and rating if necessary.
  • Storage: Store the power supply in a cool, dry place away from direct sunlight and extreme temperatures when not in use.
Rear view of the power supply showing the temperature control fan and heat dissipation vents.
Figure 6: Temperature Control Fan for Heat Dissipation

8. Troubleshooting

  • No Power: Check the AC power cord connection and the fuse in the fuse box. Ensure the main power switch is ON.
  • No Output Voltage/Current: Verify that the output leads are correctly connected. Check if any OCP mode is active and needs to be reset. Ensure the voltage and current knobs are set to desired values.
  • Overheating: Ensure the cooling fan and vents are clear of obstructions. Reduce the load if operating at maximum capacity for extended periods.
  • Inaccurate Readings: Perform voltage calibration as described in section 5.1.

9. Warranty and Support

This product comes with a standard manufacturer's warranty. For warranty claims, technical support, or service inquiries, please contact your retailer or the manufacturer's customer service department. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.