1. Introduction
This manual provides detailed instructions for the safe and efficient operation of your Aideepen XY6530S/XY6550S CNC Adjustable Step-Down Power Module. This device functions as a constant voltage/constant current regulated power supply with MPPT (Maximum Power Point Tracking) capabilities, suitable for various applications including solar charging.
2. Key Features
- Supports firmware upgrades and serial communication.
- Full-view 1.8-inch high-brightness true-color LCD with customizable color schemes and 4-way rotation support.
- Comprehensive protection mechanisms including input reverse polarity protection and output backflow prevention.
- Display board features a gold-plated design for oxidation resistance, enhanced conductivity, and durability.
- Intelligent temperature-controlled PWM stepless speed fan with low noise and a large-area heat sink.
- Supports standard Modbus protocol for serial communication.
- Independent dual serial ports, serial port TTL, and on-board 485 communication.
- Integrated fire-retardant shell with double-buckle design for enhanced safety and secure fixation.
- Silicone buttons with indicators for comfortable touch and clear status.
- Network control anytime, anywhere via LAN penetration, real-time communication, remote control via external network, email notification, and cloud record.
- Compatible with PC host computer software and Mobile APP Sinilink control (Android/iOS).
- Newly upgraded to support global weather systems and global WiFi time synchronization systems.
3. Specifications
| Parameter | XY6530S | XY6550S |
|---|---|---|
| Product Name | Digital DC Step-Down Power Supply | |
| Input Voltage | 12.00~75.00V | 12.00~70.0V |
| Output Voltage | 0~65.0V | |
| Output Current | 0~30.00A | 0~50.00A |
| Power Output | 2000W | 3250W |
| Voltage Resolution | 0.01V | |
| Current Resolution | 0.01A | |
| Accuracy of Voltage | ±0.5% + 1 word | |
| Accuracy of Current | ±0.5% + 3 word | |
| Stored Data Sets | 10 groups | |
| Soft Start | YES | |
| Screen Size | 1.8-Inch Full-View High-Brightness True Color LCD | |
| Output Ripple Typical Value | vpp-200mv | |
| MPPT Function | Support MPPT solar charging (YES) | |
| Buzzer | YES | |
| Number of Buttons | 5 | |
| Efficiency of Conversion | About 95% | |
| Screen Instrument Dimensions | 86*45*28mm | |
| Bare Board Size | 126*85.5*43mm | |
| Bare Board Weight (with packaging) | 276g (330g) | |
| Product Weight (with packaging) | 315g (425g) | |
| Bare Board Package Dimensions | 170*134*52mm | |
| Product Package Dimensions | 245*122*75mm | |
4. Package Contents
The package includes:
- 1 x Adjustable Power Supply
- 1 x Meter Head
- 1 x Cable
Note: When purchasing a bare device, switches, potentiometers, and dial switches will be welded on. If a set with a screen meter is purchased, they are not welded by default.

5. Setup and Installation
5.1 Bare Board Configuration
The bare board can be used independently. It supports MPPT and analog 0.3-10V control. Serial communication and on-board 485 communication can be used simultaneously. The output voltage is adjustable from 0-65V, and the output current is adjustable from 0-50A.

5.2 Analog Control
The device supports 0.3-10V analog control, with the measurement range configurable via software. Note that analog control is only available in the numerical control screen mode.
5.3 Potentiometer Mode and Digital Control Meter Mode
Flip the switch up to light up the green indicator light to enter potentiometer mode. Conversely, flip it down to operate in the digital control meter mode.
5.4 Setting Constant Current via Dip Switch
The constant current value can be set via a dip switch, offering a total of 16 gears to meet most scenarios. This eliminates the need for a multimeter's current range for measurement, preventing potential burnout due to insufficient range of most multimeters' 10A gear.
5.5 MPPT Solar Charging Setup
The unit supports MPPT solar charging. An external temperature probe can be connected for over-temperature protection. Attach the external temperature probe to the battery, and the unit will automatically stop charging in case of over-temperature.

Precaution:
- Ensure the unit is OFF before connecting the battery.
- Avoid reverse polarity connection to prevent device damage or fire hazards.
- Turn on the output ONLY after the battery icon appears on the screen to initiate charging.
6. Operation
6.1 Display and Navigation
The device features a 1.8-inch Full-View High-Brightness True Color LCD. The rotary encoder allows for quick and smooth page turning. The display supports customizable color schemes and 4-way rotation.



6.2 Setting Voltage and Current
There are three ways to set voltage and current:
- Quick Setup Mode:
a. Briefly press the V-SET/I-SET button to enter voltage/current setting mode.
b. Use the SW button or encoder button to move between digits.
c. Rotate the encoder to adjust the voltage/current value. Once set, briefly press V-SET/I-SET to save and exit. - Encoder Mode:
a. Briefly press the encoder button to activate the parameter (voltage/current) you want to set.
b. Press the encoder button to switch between full selection and digit selection. In full selection, all digits are highlighted. Rotate the encoder to switch between setting voltage or current. In digit selection, the selected digit is highlighted. Rotate the encoder to adjust the value.
c. To finish, either hold the encoder button/SW button for 2 seconds or wait 6 seconds without any button press. All settings are saved automatically. - Remote Control Mode:
Use the infrared remote control or 433M wireless remote control module to set voltage and current directly with the remote's numeric keypad.


6.3 CV CC CW Features Introduction

- When the constant power function is not turned on: The power supply operates in Constant Voltage (CV) and Constant Current (CC) modes, automatically switching based on the load.
a. If the load current is less than the set constant current value, the power supply is in CV mode, where the output voltage is the set CV, and the current is adaptive. - When the constant power function is turned on: The constant current value defaults to the maximum value, and the constant voltage value (CV) serves as the initial voltage (set to a reasonable value based on actual conditions). After the power supply is turned on, the equivalent resistance R of the load is calculated using Ohm's law (R=U/I). Then, the corresponding voltage can be calculated based on the set constant power value using the power formula P=U/R. At this point, the constant power point algorithm automatically follows, and constant power is achieved.
Constant Power Switch and Constant Power Value Setting
- In the system parameter settings UI, select the CW option. Turn ON to enable constant power, and turn OFF to disable constant power.
- After enabling constant power, briefly press ISET on the main interface to modify the value of constant power.
6.4 Lock Function
To lock the buttons and prevent accidental changes, hold the encoder button for more than 2 seconds. To unlock, hold the encoder button for more than 2 seconds again.
6.5 Quickly Recall Data Sets
The device supports storing and recalling up to 10 data sets.
- Recall M1 Data Set: Hold the V-SET button to quickly load the M1 data set.
- Select Data Set: Hold the I-SET button to open the data set selection window. Rotate the encoder to choose the data set you want. Then, either hold I-SET or briefly press the SW/encoder button to load the selected data set. The interface will show the currently loaded data set.
6.6 Quickly Adjust System Parameters in the Status Bar
On the main screen, briefly press the SW button to select a status bar parameter. Rotate the encoder to switch between parameters. Briefly press the SW button or encoder button to adjust the parameter or open the parameter setting interface. Use the encoder to set the value. To save and exit, either hold the SW button/encoder button or wait 6 seconds without any button press. All settings are saved automatically.

6.7 Network Control
The module supports network control via LAN penetration and real-time communication over an external network. It also supports email notifications and cloud record keeping. Control is possible through a PC host computer or the Mobile APP Sinilink, compatible with Android and iOS devices.

6.8 Global Weather and WiFi Time Synchronization
The device is newly upgraded to support global weather systems and global WiFi time synchronization, enhancing its utility and convenience.

6.9 Commercial Software
A complete set of complementary commercial software is available for use. This multi-serial port host software offers:
- Unlimited Device Connectivity: Supports multi-serial port communication, allowing up to 247 devices to be connected to a single serial port. By utilizing multiple serial ports, it enables the control of over a thousand devices in a clustered environment.
- Batch Control: Allows for batch control of all devices under a specific account, including voltage, current, switches, and other parameters, greatly improving efficiency.
- Administrative Accounts: Management accounts can be added for secure and controlled access to voltage and current settings, ensuring only authorized personnel make changes to critical parameters.

7. Firmware Upgrade
The device supports firmware upgrades to experience new features. Currently, it supports firmware upgrades through its WiFi module. In the future, it will also be possible to upgrade through multi-serial port host computer software (under development).

Important:
- Do not power off during the product upgrade process.
- If the product upgrade fails, you can press and hold the power button to power on the product and force it into the upgrade mode.
8. Protection Mechanisms
The device is equipped with comprehensive protection features:
| Protection Type | Description |
|---|---|
| Anti-reverse | YES |
| Output Reverse Current Protection | YES |
| Input Under-Voltage (LVP) | 10-75.00V, default 10V |
| Over-Voltage (OVP) | 0-67.00V, default 67.00V |
| Over-Current (OCP) | 0-32A, default 32A |
| Over-Power (OPP) | 0-2100W, default 2000W |
| Over-Temperature (OTP) | 60-110°C, default 110°C |
| Over-Time Out (OHP) | 1 minute - 99 hours 59 minutes, off by default |
| Over-Capacity (OAH) | 0-4200KAh, off by default |
| Over-Energy (OWH) | 0-4200KWh, off by default |
| External Over-Temperature (ETP) | 0-110°C, off by default |
9. User Tips
- Always ensure all connections are secure before powering on the device.
- Familiarize yourself with the various display modes and parameter settings to optimize performance for your specific application.
- Utilize the remote control or app for convenient adjustments, especially in setups where direct access to the module is limited.
- Regularly check for firmware updates to benefit from new features and improvements.
10. Maintenance
- Keep the device clean and free from dust and debris to ensure proper airflow and cooling.
- Avoid exposing the module to excessive moisture or extreme temperatures.
- Periodically check all wiring for signs of wear or damage.
- Ensure the heat sink is clear of obstructions for efficient heat dissipation.
11. Troubleshooting
- No Power: Check input voltage connections and ensure the power source is active. Verify the ON/OFF button is pressed.
- Incorrect Output: Double-check voltage and current settings. Ensure the load is properly connected.
- Over-Temperature Warning: Check for obstructions around the fan and heat sink. Reduce load if necessary. Verify external temperature probe connection if used.
- Display Issues: If the display is unresponsive, try restarting the device. If issues persist, refer to the firmware upgrade section for potential solutions.
- Communication Problems: Verify serial port connections and settings. For network control, ensure WiFi/LAN connections are stable and app settings are correct.
12. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.
A detailed user manual in PDF format is available for download: User Manual (PDF)
13. Video Demonstration
Watch this video for a practical demonstration of the power module's features and operation, including setting voltage/current, resetting data, navigating parameters, and remote control.