1. Introduction
1.1 Purpose
This manual describes the assembly, installation, operation, and troubleshooting of the PowMr Hybrid Solar Inverter. Please read this manual carefully before installations and operations. Keep this manual for future reference.
1.2 Scope
This manual provides safety and installation guidelines as well as information on tools and wiring for the PowMr Hybrid Solar Inverter.
1.3 Features
- Pure sine wave inverter output.
- Configurable input voltage range for home appliances and personal computers via LCD setting.
- Configurable battery charging current based on applications via LCD setting.
- Configurable AC/Solar Charger priority via LCD setting.
- Compatible with mains voltage or generator power.
- Automatic restart while AC is recovering.
- Overload, over temperature, and short circuit protection.
- Smart battery charger design for optimized battery performance.
- Cold start function.
- RS485 for communication with BMS to adjust charging current according to battery demand.
- Can operate with or without batteries.
- Intelligent fan speed adjustment based on temperature, load, and charging current.
- Built-in MPPT with an operating voltage range of 60V~450V and an open circuit voltage of 500Voc.
- RGB lamp displaying different colors according to inverter status (optional).
- WIFI remote monitoring (optional).
- Offline upgrade function; firmware can be upgraded through COM port.
- Grid-connected capability.
- Built-in anti-dust kit for harsh environments.
- In battery-free mode, PV systems can power loads directly.
- Equipped with lithium battery activation function.
1.4 Basic System Architecture
The inverter/charger supports a hybrid power system configuration, integrating solar power, utility/generator input, battery storage, and providing power to home appliances.

1.5 Product Overview
The PowMr Hybrid Solar Inverter is a compact, multi-functional unit designed for efficient power management. It features a clear LCD display for user interaction and various ports for connectivity.




2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION – Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation, follow required specifications to select appropriate cable sizes. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Refer to the INSTALLATION section of this manual for details.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
- NEVER cause AC output and DC input short circuits. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
3. Setup
3.1 Unpacking and Inspection
Before installation, inspect the unit. Be sure that nothing inside the package is damaged. You should have received the unit and a user manual.
3.2 Preparation
Before connecting all lines, remove the screws under the machine and remove the bottom cover plate.
3.3 Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and approximately 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to adhere to the wall vertically.
- Make sure that other objects and surfaces are left with enough space from the machine to ensure adequate heat dissipation and that there is enough room to remove the wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two M6 screws.
3.4 Battery Connection
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. It's still requested to have over-current protection installed. Please refer to typical amperage in the table below for required fuse or breaker size.
WARNING! All wiring must be performed by qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable size as below.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 4.2KW | 1 x 2AWG | 25 | 2 Nm |
Follow these steps to implement battery connection:
- Remove insulation sleeve 18 mm for positive and negative conductors.
- Suggest putting bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Connect all battery packs as shown in the diagram.
- Insert the battery wires flatly into battery connectors of the inverter and make sure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Ensure polarity at both the battery and the inverter/charger is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.

WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage in series.
CAUTION!! Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).
3.5 AC Input/Output Connection
CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between the inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from overcurrent of AC input. The recommended spec of AC breaker is 32A for 4.2KW.
CAUTION!! There are two terminal blocks with “IN” and “OUT” markings. Please do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 4.2KW | 12 AWG | 4 | 1.2 Nm |
Follow these steps to implement AC input/output connection:
- Before making AC input/output connection, be sure to open DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. Shorten phase L and neutral conductor N by 3 mm.
- Insert AC input wires according to polarities indicated on the terminal block and tighten the terminal screws. (L→LINE (brown or black), N→Neutral (blue)).
WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
- Then, insert AC output wires according to polarities indicated on the terminal block and tighten terminal screws. (L→LINE (brown or black), N→Neutral (blue)).
- Make sure the wires are securely connected.

CAUTION: Appliances such as air conditioners require at least 2-3 minutes to restart. If a power shortage occurs and recovers quickly, it can damage connected appliances. Check if your air conditioner has a time-delay function. Otherwise, the inverter/charger may trigger an overload fault.
3.6 PV Connection
CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between the inverter and PV modules.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.
| Model | Wire Size | Cable (mm²) | Torque Value (max) |
|---|---|---|---|
| 4.2KW | 1 x 12AWG | 4 | 1.2 Nm |
PV Module Selection:
When selecting proper PV modules, please be sure to consider these parameters:
- Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
| INVERTER MODEL | 4.2KW |
|---|---|
| Max. PV Array Open Circuit Voltage | 500Vdc |
| PV Array MPPT Voltage Range | 60Vdc~450Vdc |
| IMax.PV | 27A |
PV Module Wire Connection:
- Remove insulation sleeve 10 mm for positive and negative conductors.
- Suggest putting bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Check correct polarity of wire connection from PV modules and PV input connectors. Then, connect positive pole (+) of connection wire to positive pole (+) of PV input connector. Connect negative pole (-) of connection wire to negative pole (-) of PV input connector. Recommended tool: 4mm blade screwdriver.

3.7 Final Assembly
After connecting all wirings, please put the bottom cover back by screwing two screws.
3.8 Communication Connection
Wi-Fi Cloud Communication (optional):
Use the supplied communication cable to connect to the inverter and Wi-Fi module. Download the APP and install it from the APP store. Refer to the "Wi-Fi Plug Quick Installation Guideline" to set up the network and register. The inverter status will be shown by the mobile phone APP or webpage of a computer.
GPRS Cloud Communication (optional):
Use the supplied communication cable to connect to the inverter and GPRS module, and then apply external power to the GPRS module. Download the APP and install it from the APP store. Refer to the “GPRS RTU Quick Installation Guideline" to set up the network and register. The inverter status will be shown by the mobile phone APP or webpage of a computer.
Battery Communication:
Communication between the battery and the inverter can be realized through the battery communication interface, allowing the inverter and the lithium battery to exchange information (Baud rate: 9600).
Lithium Battery and Inverter Connection:
If choosing a lithium battery for the inverter, only lithium batteries that have been matched with BMS communication protocol are allowed.
- Connect the battery according to the recommended battery cable specifications.
- Insert the ring terminal of the battery cable into the battery connector of the inverter flatly, and ensure that the bolts are tightened with a torque of 2-3 Nm. Make sure that the polarities of the battery and inverter are connected correctly, and that the ring terminal is tightened with the battery terminal.
- Connect one side of the RJ45 cable to the BMS communication port of the inverter.
- Insert the other side of the RJ45 cable into the RS485 communication port on the lithium battery.
NOTE:
If you choose a lithium battery, please make sure to connect the battery and inverter with the BMS communication cable, and select the battery type as "LIB-485" mode.
Communication And Setting Of Lithium Battery:
- Connect the RJ45 communication cable between the inverter and battery. Please confirm that the lithium battery BMS port's PIN is corresponding to the inverter BMS communication port. The inverter BMS port's PIN definition is as below:
| Pin number | Port definitions |
|---|---|
| 1 | RS485B |
| 2 | RS485A |
| 3 | NG |
| 4 | NG |
| 5 | NG |
| 6 | NG |
| 7 | RS485A |
| 8 | RS485B |
In order to communicate with the lithium battery BMS, you should press the "ENTER" button for a long time, and set the battery type as "LIB-485" in program 05. Then select the matching battery protocol in Program 43.
4. Operation
4.1 Power ON/OFF
Once the unit has been properly installed and the batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.
4.2 Operation and Display Panel
The operation and display panel, located on the front of the inverter, includes three indicators, four function keys, and an LCD display, indicating the operating status and input/output power information.

LED Indicator
| LED Indicator | Messages |
|---|---|
| INV/AC (Green, Solid On) | Output is powered by utility in Line mode. |
| INV/AC (Green, Flashing) | Output is powered by battery or PV in battery mode. |
| CHG (Green, Solid On) | Battery is fully charged. |
| CHG (Green, Flashing) | Battery is charging. |
| FAULT (Red, Solid On) | Fault occurs in the inverter. |
| FAULT (Red, Flashing) | Warning condition occurs in the inverter. |
Function Keys
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4.3 LCD Display Icons
The LCD display provides various icons to indicate the inverter's status and information.
Input Source Information
- AC Input Icon: Indicates the AC input.
- PV Input Icon: Indicates the PV input.
- Numeric Display: Indicates input voltage, input frequency, PV voltage, charger current, charger power, battery voltage.
Configuration Program and Fault Information
- Setting Programs Icon: Indicates the setting programs.
- Warning/Fault Codes Icon: Indicates warning and fault codes.
- Warning (flashing): Flashing with warning code.
- Fault (lighting): Lighting with fault code.
Output Information
- Numeric Display: Indicates output voltage, output frequency, load percent, load in VA, load in Watt, and discharging current.
Battery Information
- Battery Icon: Indicates battery status.
Load Information
- Overload Icon: Indicates overload.
Mode Operation Information
- Mains Connection Icon: Indicates unit connects to the mains.
- PV Panel Connection Icon: Indicates unit connects to the PV panel.
- AC BYPASS Icon: Indicates load is supplied by utility power.
- Utility Charger Circuit Icon: Indicates the utility charger circuit is working.
- DC/AC Inverter Circuit Icon: Indicates the DC/AC inverter circuit is working.
Mute Operation
- Mute Icon: Indicates unit alarm is disabled.
4.4 LCD Setting
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use the UP or DOWN buttons to select setting programs, and the ENTER button to confirm the selection or ESC button to exit.
Detailed settings for various parameters such as charging current, input voltage range, power saving mode, battery type, auto restart functions, output frequency, output voltage, utility charging current, voltage points, and battery equalization can be found in the full PDF user manual.
4.5 Display Setting
The LCD display information can be switched by pressing the UP or DOWN key. Information includes input voltage, input frequency, PV voltage, charging current, charging power, battery voltage, output voltage, output frequency, load percentage, load in Watt, load in VA, load in Watt, DC discharging current, and main CPU Version.
4.6 Operating Mode Description
The inverter supports various operating modes:
- Standby Mode: The inverter is not turned on yet, but can charge batteries without AC output.
- Line Mode: The unit provides output power from the mains and charges the battery.
- Grid-Tie Operation: When working in Grid-Tie mode, the unit will flash.
- Battery Mode: The unit provides output power from the battery.
4.7 Battery Equalization
The equalization function helps reverse the buildup of negative chemical effects like stratification and removes sulfate crystals, which can reduce battery capacity. It is recommended to equalize the battery periodically.
How to Apply Equalization Function
You must enable the battery equalization function in monitoring LCD setting program 30 first. Then, you may apply this function by either:
- Setting the equalization interval in program 35.
- Activating equalization immediately in program 36.
When to Equalize
In the float stage, when the setting equalization interval is reached, or equalization is active immediately, the controller will start to enter the Equalize stage.
Equalize Charging Time and Timeout
In the Equalize stage, the controller supplies power to charge the battery until the battery voltage reaches the equalization voltage. Constant-voltage regulation maintains the battery voltage at the equalization voltage until the set battery equalized time is reached. If the battery voltage doesn't rise to the equalization voltage point when the equalized time expires, the charge controller will extend the equalized time until the battery voltage achieves the equalization voltage. If the battery voltage is still lower than the equalization voltage when the equalized timeout setting is over, the charge controller will stop equalization and return to the float stage.
4.8 Mains and Lithium Battery Activation Function
- After 90 seconds of mains power connection to the inverter, the machine connects to the mains and starts to work.
- If the inverter is in lithium battery mode (item 05 is Llb or Llb-485), and the mains are connected but the battery is not, the mains activation function is automatically enabled.
5. Maintenance
5.1 Clearance and Maintenance for Anti-Dust Kit
Every inverter is already installed with an anti-dust kit from the factory. The inverter will automatically detect this kit and activate an internal thermal sensor to adjust the internal temperature. This kit also keeps dust out of your inverter and increases product reliability in harsh environments.
Maintenance Steps:
- Loosen the screw in a counterclockwise direction on the top of the inverter.
- Remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and dustproof case. After cleaning, re-assemble the dust-kit back to the inverter.
NOTICE: The anti-dust kit should be cleaned from dust every one month.
6. Troubleshooting
This section provides guidance on common issues and their solutions. For persistent errors, contact customer support.
6.1 Fault Reference Code
| Fault Code | Fault Event |
|---|---|
| 01 | Fan is locked when inverter is off. |
| 02 | Over temperature |
| 03 | Battery voltage is too high |
| 04 | Battery voltage is too low |
| 05 | Output short circuited or over temperature is detected by internal converter components. |
| 06 | Output voltage is too high. |
| 07 | Overload time out |
| 08 | Bus voltage is too high |
| 09 | Bus soft start failed |
| 51 | Over current or surge |
| 52 | Bus voltage is too low |
| 53 | Inverter soft start failed |
| 55 | Over DC voltage in AC output |
| 57 | Current sensor failed |
| 58 | Output voltage is too low |
| 59 | PV voltage is over limitation |
6.2 Warning Indicator
| Warning Code | Warning Event | Audible Alarm |
|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second |
| 03 | Battery is over-charged | Beep once every second |
| 04 | Low battery | Beep once every second |
| 07 | Overload | Beep once every 0.5 second |
| 10 | Output power derating | Beep twice every 3 seconds |
| 15 | PV energy is low. | Beep twice every 3 seconds |
| 16 | AC voltage is over limitation | Beep twice every 3 seconds |
| E9 | Battery equalization | None |
| 6P | Battery is not connected | None |
7. Specifications
7.1 Line Mode Specifications
| Parameter | Value (4.2KW) |
|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Nominal Input Voltage | 230Vac |
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) |
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) |
| High Loss Voltage | 280Vac±7V |
| High Loss Return Voltage | 270Vac±7V |
| Max AC Input Voltage | 300Vac |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
| Low Loss Frequency | 40±1Hz |
| Low Loss Return Frequency | 42±1Hz |
| High Loss Frequency | 65±1Hz |
| High Loss Return Frequency | 63±1Hz |
| Output Short Circuit Protection | Circuit Breaker |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
7.2 Inverter Mode Specifications
| Parameter | Value (4.2KW) |
|---|---|
| Rated Output Power | 4.2KW |
| Output Voltage Waveform | Pure Sine Wave |
| Output Voltage Regulation | 230Vac±5% |
| Output Frequency | 50Hz |
| Peak Efficiency | 93% |
| Overload Protection | 3s@≥150% load; 30s@101%~150% load |
| Surge Capacity | 2* rated power for 3 seconds |
| Nominal DC Input Voltage | 24Vdc |
| Cold Start Voltage | 23.0Vdc |
| No Load Power Consumption | 25W |
| Saving Mode Power Consumption | < 10W |
7.3 Two Load Output Power
| Parameter | Value |
|---|---|
| Full Load | 4200W |
| Maximum Main Load | 4200W |
| Second Load Range | 840W~2940W |
| Main Load Cut Off Voltage | 22VDC |
| Main Load Return Voltage | 26VDC |
7.4 Charge Mode Specifications
| Parameter | Value |
|---|---|
| Charging Algorithm | 3-Step |
| AC Charging Current (Max) | 100Amp (@VI/P=230Vac) |
| Bulk Charging Voltage (Flooded Battery) | 29.2 |
| Bulk Charging Voltage (AGM / Gel Battery) | 28.2 |
| Floating Charging Voltage | 27Vdc |
| Parameter | Value |
|---|---|
| Max. PV Array Power | 6200W |
| Nominal PV Voltage | 240Vdc |
| PV Array MPPT Voltage Range | 60Vdc~450Vdc |
| Max. PV Array Open Circuit Voltage | 500Vdc |
| Max Charging Current (AC charger plus solar charger) | 120Amp |
7.5 General Specifications
| Parameter | Value |
|---|---|
| Safety Certification | CE |
| Operating Temperature Range | -10°C to 50°C |
| Storage temperature | -15°C~60°C |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) |
| Dimension (D*W*H), mm | 423×344×112 |
| Net Weight, kg | 7.2 |
7.6 Approximate Back-up Time Table
| Load (W) | Backup Time @ 24Vdc 100Ah (min) | Backup Time @ 24Vdc 200Ah (min) |
|---|---|---|
| 300 | 449 | 1100 |
| 600 | 222 | 525 |
| 900 | 124 | 303 |
| 1200 | 95 | 227 |
| 1500 | 68 | 164 |
| 1800 | 56 | 126 |
| 2100 | 48 | 108 |
| 2400 | 35 | 94 |
| 2700 | 31 | 74 |
| 3200 | 28 | 67 |
| 3600 | 25 | 60 |
| 4200 | 22 | 53 |
Note:
- Backup time depends on the quality of the battery, age of battery, and type of battery. Specifications of batteries may vary depending on different manufacturers.
- The final interpretation right of this product belongs to the company.
8. User Tips
- Proper Sizing: Ensure your solar panel array and battery bank are correctly sized for your energy needs and compatible with the inverter's specifications (e.g., PV array MPPT voltage range, max charging current).
- Regular Cleaning: Adhere to the monthly cleaning schedule for the anti-dust kit to maintain optimal performance and prolong the inverter's lifespan, especially in dusty environments.
- Monitor LCD Settings: Regularly check and adjust LCD settings for charging current, AC/Solar priority, and input voltage range to match your specific application and battery type for efficient operation.
- Battery Compatibility: When using lithium batteries, ensure they are compatible with the BMS communication protocol and correctly configured in the inverter's settings (LIB-485 mode).
- Safety First: Always follow safety instructions, especially regarding wiring and disconnections, and ensure installation is performed by qualified personnel to prevent electric shock or fire hazards.
9. Warranty and Support
9.1 Warranty Information
All PowMr products come with a 1-year warranty from the date of purchase. Please retain your proof of purchase for warranty claims.

9.2 Contact Information
For technical support, warranty claims, or any inquiries regarding your PowMr Hybrid Solar Inverter, please contact us:
- Email: support@powmr.com
- Website: www.powmr.com
- Tel/Fax: +86755-28219903
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China
You can also refer to the official user manual PDF for more detailed information: User Manual (PDF)