1. Introduction
The JIKONG JK-PB2A16S10P V19 LCD Household Energy Inverter BMS is an intelligent battery management system designed for large-capacity series lithium battery packs. It offers comprehensive features including voltage acquisition, high-current active balancing, overcharge and over-temperature protection, coulomb metering, Bluetooth communication, and host computer monitoring.
This protection board is suitable for various battery types, including lithium iron phosphate (LiFePO4), ternary lithium (Li-ion), and lithium titanate (LTO) batteries. It utilizes energy transfer active balancing technology with independent intellectual property rights, achieving a maximum continuous 2A balance current. This high-current active equalization technology ensures battery consistency, improves battery range, and delays battery aging.
The BMS features a compact size, simple operation, and full functionality, making it ideal for high-power energy storage, base station backup power supplies, and solar power station battery packs.
2. Key Features
- Active Equalization: Up to 2A continuous active balancing current for enhanced battery consistency and lifespan.
- Wide Compatibility: Supports 7-16S Li-ion, 8-16S LiFePO4, and 14-16S LTO battery strings.
- Comprehensive Protection: Includes charge/discharge overvoltage, overcurrent, overtemperature, low temperature, and short circuit protection.
- Intelligent Communication: Features Bluetooth, RS485, and CAN communication interfaces.
- Monitoring & Control: Mobile APP (Android/iOS) and PC software for real-time monitoring, parameter modification, and charge/discharge switch control.
- Display Interface: Reserved interface for optional LCD display to view battery information conveniently.
- Heating Function: Standard heating function for low-temperature environments (10A current) to maintain battery activity.
- Dry Contact Function: Two dry contacts for controlling external alarms or fans based on battery status.
- Intelligent Sleep Mode: Reduces self-consumption during standby by automatically turning off the protection board.
- Charge Current Limiting: Limits charging current to approximately 10A during overcurrent conditions to protect the battery.
- Parallel Function: Supports monitoring of up to 16 BMS units via RS485 bus for large-scale energy storage systems.
3. Specifications
3.1. General Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 20-70 | V |
| Standby Power Consumption | 12 | mW |
| Operating Power Consumption | 1100 | mW |
| Operating Temperature | -30 to 70 | °C |
| Maximum Number of Collection Strings | 16 | S |
| Maximum Balancing Current | 2 | A |
| Maximum Charging Current | 300 | A |
| Maximum Discharge Current | 300 | A |
| Maximum Instantaneous Current | 600 | A |
| Maximum Internal Loop Resistance | 0.25 | mΩ |
| Protective Plate Size | 300*100*24 | mm |
| Finished Weight | 1000 | g |
3.2. Battery Type Compatibility
| Battery Type | Number of Adaptive Battery Strings |
|---|---|
| Ternary Lithium Battery (Li-ion) | 7-16S |
| Lithium Iron Battery (LiFePO4) | 8-16S |
| Lithium Titanate Battery (LTO) | 14-16S |
3.3. LCD Display Dimensions
The optional LCD display comes in two sizes:
- Large LCD: 187mm x 120mm (display area 154mm x 86mm)
- Small LCD: 136.5mm x 95.4mm (display area 96.5mm x 55.4mm)

Figure: Large LCD Display Dimensions (187mm x 120mm)

Figure: Small LCD Display Dimensions (136.5mm x 95.4mm)
4. Package Contents
The standard package for the JK-PB2A16S10P BMS includes the following items:
- 1 x Packing Box
- 1 x BMS Unit
- 1 x Interface Board
- 1 x Adapter
- 1 x RJ45 Network Cable (400mm)
- 1 x Switch (500mm)
- 1 x Heating Adapter Cable (170mm)
- 1 x Cells Total B+ Cable (500mm)
- 2 x Sampling Line A (900mm)
- 2 x Sampling Line B (900mm)
- 2 x Sampling Line C (900mm)
- 2 x Adapter Cable A (300mm)
- 2 x Adapter Cable B (300mm)
- 2 x Adapter Cable C (300mm)
- 1 x 4.3LCD-TTL-P (Optional, if selected)

Figure: Package Contents
Video: Unboxing and overview of the JK BMS V19.
5. Setup and Installation
5.1. Safety Precautions
- Before starting, ensure all balance cables are properly connected.
- Verify that the P- and B- connections are correct.
- Ensure the protection board is securely fixed to the battery pack.
- Incorrect connections can lead to abnormal operation or damage to the device.
5.2. Wiring Method
The wiring method varies depending on the number of battery cells in your pack. Refer to the diagrams below for 16-string and 8-string configurations.

Figure: Wiring methods for 16-string and 8-string cells
5.3. Interface Board Connections
The interface board provides various ports for communication, display, and control. Familiarize yourself with the layout and pin definitions:

Figure: Interface Board Diagram with Ports
Key Interface Definitions:
- P1 (Interface Board Interface): Connects to the main BMS board.
- P4 (URAT Display Interface): For connecting the optional LCD display.
- P5 (Display Interface): For connecting the optional LCD display.
- P6, P7, P8, P9 (Acquisition Interface): For connecting NTC temperature probes and battery cell voltage sampling lines.
- P10 (Heating Interface): For connecting the heating element (HT-).
- P11 (Power Input): For connecting the main power input (B+).
- RS485-1: For communication with inverters.
- RS485-2: For parallel connection of BMS units and communication with upper computer.
- CAN: For CAN communication.
- Dry Contact: For controlling external devices like alarms or fans.
- Dip Switch: Used to set the communication address for parallel operation (0-15).
5.4. Device Activation
The BMS does not have a power-on control switch. It is designed for charging activation. After completing the battery assembly and all connections, connect a charger (voltage 2V higher than battery voltage) to activate the BMS.
Alternatively, if you have an optional display screen or button, you can activate the BMS by inserting the cable into the display interface and pressing the button.
6. Operating Instructions
6.1. APP Installation
To install the mobile APP, scan the QR code below. The Android APP requires Android Version 7 or higher.

Figure: Mobile APP Link QR Code
6.2. Parameter Setting and Monitoring
The JIKONG BMS APP (for Android/iOS) and PC software allow you to monitor battery status and configure various parameters. Connect to the BMS via Bluetooth (for APP) or RS485/CAN (for PC software).

Figure: PC Software Interface for BMS Monitoring

Figure: APP Interface for Inverter Communication Protocols
Key Operations:
- Active Equalization: Set the balance trigger pressure difference (mV) in the APP. Balancing automatically activates when the voltage difference between any two strings exceeds the set value and turns off when it falls below. The default balance current is 2A. It is recommended that the balance current not exceed 0.2C of the battery capacity.
- Heating Function: If equipped, the heating function can be switched ON/OFF via the APP to warm the battery in low temperatures.
- Dry Contact Function: Configure the dry contacts in the APP to control external alarms or fans based on overtemperature, overcharge, or overdischarge states.
- Charge Current Limiting: Set continuous charging current, overcurrent delay, and release time in the APP. The BMS will limit the charging current to approximately 10A during overcurrent events.
6.3. Parallel Function
The parallel function allows simultaneous monitoring of multiple BMS units via the RS485 bus. To use this feature, you will need a USB to RS485 serial port cable and the JIKONG upper computer software.
- Address Setting: Each BMS unit needs a unique address (0-15) set via the DIP switch on the interface board. BMS with address 0 acts as the host, and 1-15 are slaves.
- Connection: Connect the upper computer to the host BMS via the USB to RS485 cable. Then, connect the host BMS to slave BMS units using RJ45 Ethernet cables for RS485-2 communication.

Figure: BMS with Communication Interfaces
7. Maintenance
- Regular Checks: Periodically inspect all wiring connections for tightness and integrity.
- Software Updates: Keep your mobile APP and PC software updated to the latest versions for optimal performance and new features.
- Intelligent Sleep: Enable the intelligent sleep function in the APP to reduce the BMS's self-consumption when the battery is in standby (charging/discharging current less than 1A for 26 consecutive hours). This helps prolong battery life.
- Cleaning: Ensure the BMS and its components are free from dust and debris to maintain proper heat dissipation.
8. Troubleshooting
The BMS is equipped with various protection functions to ensure battery safety. When a protection is triggered, the BMS will take action (e.g., stop charging/discharging) and will recover once conditions return to normal.
8.1. Protection Functions and Recovery
- Charge Overvoltage Protection: If any cell's voltage exceeds the set overcharge protection voltage during charging, the BMS will stop charging. It will resume once all cell voltages drop below the recovery voltage.
- Discharge Undervoltage Protection: If any cell's voltage drops below the set undervoltage protection voltage during discharge, the BMS will stop discharging. It will resume once all cell voltages rise above the recovery voltage. If a cell voltage drops below the automatic shutdown voltage, the BMS will shut down.
- Charge/Discharge Overcurrent Protection: If the current exceeds the set continuous current for a specified delay, the BMS will stop charging/discharging. It will resume after the overcurrent release time.
- Overtemperature Protection: If the temperature exceeds the set overtemperature protection value, the BMS will stop charging/discharging. It will resume once the temperature drops below the recovery value.
- Low Temperature Protection (Charging): If the temperature drops below the set low temperature protection value during charging, the BMS will stop charging. It will resume once the temperature rises above the recovery value.
- Short Circuit Protection: The BMS will protect against short circuits. If a short circuit occurs, the BMS will stop operation and recover after a set delay. If protection is triggered upon connecting a charger or load, consider increasing the short circuit protection delay in the APP.
8.2. Emergency Switch
In case of issues like over-temperature, over-discharge, over-charge, or dropped strings during normal use, you can activate the emergency switch via the BMS control page in the APP. This will enable both charging and discharging for 30 minutes, providing an emergency use period to prevent critical situations.8.3. LED Indicators
The LED indicators on the BMS provide visual feedback on its status:
| Status | RUN LED | ALM LED | L1-L6 LEDs | Description |
|---|---|---|---|---|
| Power Off | OFF | OFF | OFF | Device is off. |
| Normal (Balance) | Flashing | OFF | Indicates battery capacity | BMS is balancing cells. |
| Normal (Charging) | ON | OFF | Indicates battery capacity | BMS is charging. |
| Normal (Discharging) | ON | OFF | Indicates battery capacity | BMS is discharging. |
| Protection Triggered | Flashing | Flashing | Indicates battery capacity | A protection event (e.g., overcurrent, overtemp) has occurred. |
| Bluetooth Connected | Steady ON | N/A | N/A | Bluetooth connection is active. |
| Bluetooth Disconnected | Blinking | N/A | N/A | Bluetooth is not connected. |
9. User Tips
- Always ensure all connections are secure and correct before powering on the BMS to prevent damage.
- For optimal battery longevity, regularly monitor cell voltages and temperatures via the APP or PC software.
- If experiencing frequent short-circuit protection triggers during charger or load connection, try increasing the 'Short-circuit protection delay' setting in the APP.
- In cold climates, utilize the heating function to maintain battery performance and prevent low-temperature protection from activating.
10. Warranty and Support
For detailed warranty information and technical support, please refer to the official user manual PDF provided by JIKONG. You can access the PDF via this link: JIKONG BMS User Manual (PDF).
For direct inquiries, you may contact JIKONG support:
- Contact Person: Jason Liu
- Phone/WeChat/WhatsApp: +86 13068721990