DATOUBOSS DT4811B

Contents

DATOUBOSS Solar Hybrid Inverter Instruction Manual

Model: DT4811B (Also applicable to SP-3200 and other variants)

Brand: DATOUBOSS

1. Introduction

This manual provides essential information for the safe and efficient operation of your DATOUBOSS Solar Hybrid Inverter. It covers installation, operation, maintenance, and troubleshooting. The DATOUBOSS hybrid inverter is a multi-function inverter/charger that combines the functions of an inverter, solar charger, and battery charger to provide an uninterrupted power supply with a portable size.

Key features include:

  • Pure sine wave output (THD <3%)
  • User-configurable input voltage range for home appliances and PCs via LCD setting
  • Configurable battery charging current based on applications via LCD setting
  • Configurable AC/Solar charger priority via LCD setting
  • Compatible with mains voltage or generator power
  • Automatic restart while AC recovers
  • Overload, over-temperature, and short circuit protection
  • Intelligent battery charger design for optimized battery performance
  • Cold start function
  • Can be connected to a lithium battery
  • Intelligent fan speed adjustment

Important Note: This inverter operates in OFF-grid mode and does not feed electricity into the grid. Please verify your PV voltage carefully before purchasing and ensure it is compatible with the inverter's MPPT range (e.g., 90-430V for DT4811B, 55-450V for SP-3200).

2. Setup and Installation

2.1 Product Overview and Dimensions

Familiarize yourself with the inverter's appearance and dimensions for proper placement and installation.

DATOUBOSS Inverter Dimensions
Figure 2.1: DATOUBOSS Inverter Dimensions. One unit measures approximately 39cm (15.4in) H x 30.5cm (12in) W x 11cm (4.3in) D. Another unit measures approximately 49cm (19.3in) H x 31cm (12.2in) W x 11.5cm (4.5in) D.

2.2 Component Identification

Identify the various ports, indicators, and controls on your inverter.

Inverter Appearance Description
Figure 2.2: Inverter Appearance Description. Key components include RS-232 communication port, Switch, Liquid crystal display, Status display, Error display, Function keys (ESC, UP, DOWN, ENTER), Charging indicator, AC Output, AC Input, Battery Input, Photovoltaic Input (PV IN), Safety grounding, and Circuit breaker.

2.3 System Connection Diagrams

The following diagrams illustrate how to connect the inverter to form a complete operating system, including photovoltaic modules, generators, batteries, and household loads. Ensure all connections are secure and follow local electrical codes.

Basic System Connection Diagram
Figure 2.3: Basic System Connection Diagram. Shows connections between Photovoltaic modules, Generators, Inverters, Batteries, and various household Loads (e.g., lights, cooker, microwave, washing machine, air conditioner).
Comprehensive System Connection Diagram
Figure 2.4: Comprehensive System Connection Diagram. Illustrates connections including Generator, Utility Grid, Solar Panel, Inverter, Home Loads, Battery, and optional monitoring via CubeWiFi/CubeGPRS, Internet, PVguarder APP, and PVguarder Web.

2.4 Parallel Operation

The inverter supports parallel operation, allowing multiple units to be connected for increased power output. This feature is particularly useful for larger energy demands.

Hybrid Solar Inverter Features
Figure 2.5: Hybrid Solar Inverter Features. Highlights 48V DC to 220V/230V AC conversion, support for parallel operation and grid connection, and a 160A MPPT controller.

3. Operating Instructions

3.1 Powering On/Off

Use the main switch to power on or off the inverter. Ensure all connections are correct before powering on.

3.2 LCD Display and Settings

The comprehensive LCD display allows for user-configurable settings. Use the function keys (ESC, UP, DOWN, ENTER) to navigate menus and adjust parameters such as battery charging current, AC/solar charger priority, and acceptable input voltage.

3.3 Operating Modes

The inverter supports various operating modes, including AC priority and solar charger priority. Configure these settings via the LCD to optimize power usage based on your specific needs.

3.4 Cold Start Function

The inverter is equipped with a cold start function, allowing it to power on even when there is no AC input or solar power, provided the battery has sufficient charge.

3.5 Remote Monitoring with Wi-Fi Module

The optional Wi-Fi module provides convenient remote monitoring and control functions, enhancing the manageability of your solar energy system. Users can monitor system performance, real-time data, and remotely control the inverter from smart devices.

Wi-Fi Module and RS232 Cable
Figure 3.1: Wi-Fi Module and RS232 Cable. The Wi-Fi module allows remote monitoring and control of the inverter via a dedicated app or web interface.

With the Wi-Fi module, you can:

  • Track important information such as the system's power generation, power output, and battery status in real-time.
  • Access data analysis and recording functions to understand historical trends of system performance.
  • Remotely start or shut down the inverter.
  • Manage the distribution and storage of power to maximize system efficiency.

3.6 Compatible Devices

The solar inverter can power a variety of electrical devices in your home or office.

Compatible Devices and Overload Warning
Figure 3.2: Compatible Devices. Examples include Tube Lights, Fans, Refrigerators, and Air Conditioners. Do not Overload!

4. Maintenance

To ensure the longevity and optimal performance of your DATOUBOSS Solar Hybrid Inverter, regular maintenance is recommended:

  • Cleaning: Keep the inverter's exterior clean and free from dust and debris. Ensure ventilation openings are not blocked.
  • Connection Checks: Periodically inspect all electrical connections (PV, battery, AC input/output) to ensure they are tight and free from corrosion.
  • Environment: Ensure the inverter is installed in a well-ventilated area, away from direct sunlight, moisture, and flammable materials.
  • Battery Health: If using external batteries, monitor their health and charge status as recommended by the battery manufacturer.

5. Troubleshooting

The inverter is designed with several protection features to ensure safe operation. If you encounter issues, consider the following:

  • No Power Output: Check AC input, battery connections, and solar panel input. Ensure the inverter is switched on.
  • Overload Protection: If an overload occurs, the inverter will shut down. Reduce the connected load and restart the inverter.
  • Over-temperature Protection: If the inverter overheats, it will shut down. Ensure adequate ventilation and clear any obstructions from the cooling fans.
  • Short Circuit Protection: The inverter will protect itself from short circuits. Identify and resolve any short circuits in the wiring or connected loads.
  • AC Recovery: The inverter features automatic restart when AC power recovers.

For persistent issues, consult a qualified technician or contact DATOUBOSS customer support.

6. Specifications

Below are detailed specifications for the DATOUBOSS Solar Hybrid Inverter models DT4811B and SP-3200.

6.1 DT4811B Model Specifications

DT4811B Detailed Parameters
Figure 6.1: Detailed Parameters for DATOUBOSS DT4811B Inverter.
Table 6.1: DT4811B Technical Specifications
ParameterValue
Capacity11000VA/11000W
Operating Temperature Range10-50°C
ProtectionIP21
Inverter Mode - DC Input48VDC 254.6A
Inverter Mode - AC Output230VAC, 50/60Hz, 47.8A, 1Φ
AC Input - AC Charger54VDC 150A
AC Input - AC Input Voltage/Frequency/Current230VAC, 50/60Hz, 60A, 1Φ
AC Input - AC Output Voltage/Frequency/Current230VAC, 50/60Hz, 47.8A, 1Φ
Solar Mode - Solar Panel Power2x5500W
Solar Mode - Max Charging Current150A
Solar Mode - Solar Voltage Range (Vmp)90-500VDC
Solar Mode - Best Voltage Range (Vmp)300-400VDC
Solar Mode - Max Solar Voltage500VDC

6.2 SP-3200 Model Specifications

SP-3200 Detailed Parameters
Figure 6.2: Detailed Parameters for DATOUBOSS SP-3200 Inverter.
Table 6.2: SP-3200 Technical Specifications
ParameterValue
Model NameSP-3200
Operating Temperature Range0-55°C
Inverter Mode - Rated Power3200VA/3000W
Inverter Mode - DC Input24VDC, 125A
Inverter Mode - AC Output230VAC, 50/60Hz, 13A, 1Φ
AC Charger Mode - DC Output27VDC, Max. 60A, Default 30A
AC Charger Mode - AC Output230VAC, 50/60Hz, 13A, 1Φ
Solar Charger Mode - Rated Power3000W
Solar Charger Mode - Max Charger80A
Solar Charger Mode - Nominal Operating Voltage240VDC
Solar Charger Mode - Max. Solar Voltage (VOC)450VDC
Solar Charger Mode - MPPT Voltage Range55 ~ 450VDC
Ingress ProtectionIP21
Protective ClassClass I

6.3 General Product Specifications

Table 6.3: General Technical Specifications
ParameterValue
TypeDC/AC Inverters
DIY SuppliesElectrical
OriginMainland China, Henan
CertificationCE
ApplicationPump, motor, Industrial, Compressor, Automotive, home, Air Conditioner
PhaseSingle Phase, Three Phase
NetworkWi-Fi
Output CurrentAccording to the load
Output Frequency50Hz/60Hz
Efficiency98%
Output WaveformPure Sine Wave
Nominal AC Output Voltage220/230/240VAC

6.4 DATOUBOSS LiFePO4 Battery Specifications

The inverter is compatible with lithium batteries. Here are specifications for DATOUBOSS LiFePO4 batteries:

12V 100Ah LiFePO4 Battery
Figure 6.3: DATOUBOSS 12V 100Ah LiFePO4 Battery.
Table 6.4: LiFePO4 Battery Specifications
Parameter12A(120A)100AH LiFePO412A(200A)300AH LiFePO4
Capacity1280Wh3840Wh
Battery Size33*17*21.5CM49*26*22CM
Battery Weight10.6KG30KG
Package Size39*23.5*28.5CM56*34*30CM
Package Weight11.8KG30KG

7. User Tips

  • PV Voltage Compatibility: Always ensure your solar panel (PV) voltage is within the specified MPPT range of your inverter model (e.g., 90-430V for DT4811B, 55-450V for SP-3200) for optimal charging and performance.
  • Avoid Overloading: Do not connect loads that exceed the inverter's rated power capacity. Overloading can trigger protection mechanisms and potentially damage the unit or connected appliances.
  • Ventilation: Maintain clear airflow around the inverter to prevent overheating, especially during high power output.
  • Lithium Battery Integration: When connecting lithium batteries, ensure they are compatible with the inverter's battery management system (BMS) and voltage requirements.

8. Warranty and Support

DATOUBOSS products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact DATOUBOSS customer service directly. Ensure you have your product model and serial number ready when seeking support.

9. Product Assembly Video

Watch this video for a visual guide on the assembly process of a DATOUBOSS hybrid inverter.

Video 9.1: Assembly of the SP-3000 Hybrid Inverter. This video demonstrates the internal component placement and casing assembly.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.