PowMr POW-HVM4.2K-24V-E, POW-HVM6.2K-48V-E

Contents

PowMr Hybrid Solar Inverter User Manual

Models: POW-HVM4.2K-24V-E & POW-HVM6.2K-48V-E

1. Introduction

This manual describes the assembly, installation, operation, and troubleshooting of the PowMr Hybrid Solar Inverter. Please read this manual carefully before installation and operation. Keep this manual for future reference.

This multi-function inverter/charger combines the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support in a portable size. Its comprehensive LCD display offers user-configurable and easy-to-access button operation for settings such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

1.1 Features

  • Pure sine wave inverter output.
  • Configurable input voltage range for home appliances and personal computers via LCD settings.
  • Configurable battery charging current based on applications via LCD settings.
  • Configurable AC/Solar Charger priority via LCD settings.
  • Compatible with mains voltage or generator power.
  • Auto restart while AC is recovering.
  • Overload, over temperature, and short circuit protection.
  • Smart battery charger design for optimized battery performance.
  • Cold start function.
  • RS485 communication with BMS to adjust charging current according to battery demand.
  • Can work with or without batteries.
  • Intelligent fan speed adjustment based on temperature, load, and charging current.
  • Built-in MPPT with an operating voltage range of 60V-500V (Max PV Input).
  • RGB lamp displays different colors according to inverter status.
  • WIFI remote monitoring (optional).
  • Offline upgrade function; firmware can be upgraded through the COM port.
  • Grid-connected capability.
  • Built-in anti-dust kit for harsh environments.
  • In battery-free mode, PV systems deliver a better user experience when powering loads.
  • Equipped with lithium battery activation function.

PowMr Hybrid Solar Inverter showing key features
Figure 1: PowMr Hybrid Solar Inverter with key specifications.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  3. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  4. CAUTION – Only qualified personnel can install this device with battery.
  5. NEVER charge a frozen battery.
  6. For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
  7. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  8. Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for details.
  9. One piece of 150A fuse is provided as over-current protection for the battery supply.
  10. GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
  11. NEVER cause AC output and DC input short circuits. Do NOT connect to the mains when DC input short circuits.
  12. Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.

3. Setup (Installation)

3.1 Unpacking and Inspection

Before installation, please inspect the unit. Ensure nothing inside the package is damaged. You should have received the inverter unit and a user manual.

3.2 Preparation

Before connecting any lines, remove the screws under the machine and remove the bottom cover plate.

3.3 Mounting the Unit

Consider the following points when selecting where to install:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level to allow the LCD display to be read at all times.
  • For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and 50 cm above and below the unit.
  • The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  • The recommended installation position is to be adhered to the wall vertically.
  • Ensure other objects and surfaces are left with enough space from the machine to ensure adequate heat dissipation and that there is enough room to remove the wires.

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Install the unit by screwing two M6 screws.

3.4 Battery Connection

CAUTION:

For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed. Please refer to typical amperage in the specifications table for required fuse or breaker size.

WARNING!

All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable as below:

ModelWire SizeCable (mm²)Torque value (max)
4.2KW/6.2KW1 x 2AWG252 Nm

Follow these steps to implement battery connection:

  1. Remove insulation sleeve 18 mm for positive and negative conductors.
  2. Suggest putting bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Connect all battery packs as shown in the diagram below.
  4. Insert the battery wires flatly into battery connectors of the inverter and make sure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Ensure polarity at both the battery and the inverter/charger is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.

Battery compatibility and charging current
Figure 2: Inverter compatibility with various battery types and maximum charging current.

WARNING: Shock Hazard

Installation must be performed with care due to high battery voltage in series.

CAUTION!!

Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).

3.5 AC Input/Output Connection

CAUTION!!

Before connecting to AC input power source, please install a separate AC breaker between the inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from overcurrent of AC input. The recommended spec of AC breaker is 32A for 4.2KW and 50A for 6.2KW.

CAUTION!!

There are two terminal blocks with “IN” and “OUT” markings. Please do NOT mis-connect input and output connectors.

WARNING!

All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.

ModelGaugeCable (mm²)Torque Value
4.2KW12 AWG41.2 Nm
6.2KW10 AWG61.2 Nm

Follow these steps to implement AC input/output connection:

  1. Before making AC input/output connection, be sure to open DC protector or disconnector first.
  2. Remove insulation sleeve 10mm for six conductors. And shorten phase L and neutral conductor N 3 mm.
  3. Insert AC input wires according to polarities indicated on terminal block and tighten the terminal screws. (L→LINE (brown or black), N→Neutral (blue))

WARNING:

Be sure that AC power source is disconnected before attempting to hardwire it to the unit.

  1. Then, insert AC output wires according to polarities indicated on terminal block and tighten terminal screws. (L→LINE (brown or black), N→Neutral (blue))
  2. Make sure the wires are securely connected.

CAUTION:

Appliances such as air conditioners require at least 2-3 minutes to restart because it's required to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check the manufacturer of the air conditioner if it's equipped with a time-delay function before installation. Otherwise, this inverter/charger will trigger an overload fault and cut off output to protect your appliance, but sometimes it still causes internal damage to the air conditioner.

3.6 PV Connection

CAUTION:

Before connecting to PV modules, please install separately a DC circuit breaker between the inverter and PV modules.

WARNING!

It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.

ModelWire SizeCable (mm²)Torque value (max)
4.2KW/6.2KW1 x 12AWG41.2 Nm

PV Module Selection:

When selecting proper PV modules, please be sure to consider below parameters:

  1. Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
  2. Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
INVERTER MODEL4.2KW6.2KW
Max. PV Array Open Circuit Voltage500Vdc
PV Array MPPT Voltage Range60Vdc~450Vdc
IMax.PV27A

Rear panel connections for AC, Battery, PV, and Communication
Figure 3: Rear panel connections for AC, Battery, PV, and Communication.

3.7 Final Assembly

After connecting all wirings, please put the bottom cover back by screwing two screws.

3.8 Communication Connection

1. **Wi-Fi cloud communication (option):** Use the supplied communication cable to connect to the inverter and Wi-Fi module. Download the APP from the App Store and refer to the "Wi-Fi Plug Quick Installation Guideline" to set up the network and register. The inverter status will be shown by mobile phone APP or a webpage. (Note: WiFi module needs to be purchased separately if not included).
Remote monitoring via SMARTESS app
Figure 4: Remote monitoring and control via the SMARTESS app.

2. **GPRS cloud communication (option):** Use the supplied communication cable to connect to the inverter and GPRS module, and then apply external power to the GPRS module. Download the APP from the App Store and refer to the "GPRS RTU Quick Installation Guideline" to set up the network and register. The inverter status will be shown by mobile phone APP or a webpage.

3. **Battery communication:** The communication between the battery and the inverter can be realized through the battery communication interface, allowing the inverter and the lithium battery to exchange information (Baud rate: 9600).

4. **Lithium battery and inverter connection:** If choosing a lithium battery for the inverter, only lithium batteries that have been matched with BMS communication protocol are allowed.

  1. Connect the battery according to the recommended battery cable specifications.
  2. Insert the ring terminal of the battery cable into the battery connector of the inverter flatly, and ensure that the bolts are tightened with a torque of 2-3 Nm. Make sure that the polarities of the battery and inverter are connected correctly, and that the ring terminal is tightened with the battery terminal.
  3. Connect one side of the RJ45 cable to the BMS communication port of the inverter.
  4. Insert the other side of the RJ45 cable into the RS485 communication port on the lithium battery.

NOTE:

If you choose a lithium battery, please make sure to connect the battery and inverter with the BMS communication cable, and select the battery type as "LIB-485" mode.

In order to communicate with the lithium battery BMS, you should press the "ENTER" button for a long time, and set the battery type as "LIB-485" in program 05. Then select the matching battery protocol in Program 43.

Pin numberPort definitions
1RS485B
2RS485A
3NG
4NG
5NG
6NG
7RS485A
8RS485B

4. Operating

4.1 Power ON/OFF

Once the unit has been properly installed and the batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.

4.2 Operation and Display Panel

The operation and display panel, shown below, is on the front panel of the inverter. It includes three indicators, four function keys, and an LCD display, indicating the operating status and input/output power information.

LED IndicatorColorStatusMessages
INV/ACGreenSolid OnOutput is powered by utility in Line mode.
FlashingOutput is powered by battery or PV in battery mode.
CHGGreenSolid OnBattery is fully charged.
FlashingBattery is charging.
FAULTRedSolid OnFault occurs in the inverter.
FlashingWarning condition occurs in the inverter.
Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

LED patterns for different working modes
Figure 5: RGB LED patterns indicating different working modes.

4.3 LCD Display Icons

The LCD display provides detailed information about the inverter's status. Here's a breakdown of the icons:

IconFunction description
Indicates the AC input.
Indicates the PV input.
8.8.8Indicates input voltage, input frequency, PV voltage, charger current, charger power, battery voltage.
8.8.8Indicates the setting programs.
8.8.8Indicates the warning and fault codes.
8.8.8Indicates output voltage, output frequency, load percent, load in VA, load in Watt and discharging current.
Battery Information
OVER LOADIndicates overload.
Indicates unit connects to the mains.
Indicates unit connects to the PV panel.
AC BYPASSIndicates load is supplied by utility power.
Indicates the utility charger circuit is working.
Indicates the DC/AC inverter circuit is working.
Indicates unit alarm is disabled.

4.4 LCD Setting

After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use the “UP” or “DOWN” button to select setting programs, then press “ENTER” to confirm or “ESC” to exit. Detailed settings are available in the full PDF manual.

4.5 Operating Mode Description

The inverter supports various operating modes including Standby, Line Mode, Grid-Tie, and Battery Mode. Each mode has specific behaviors for power sourcing and charging. For detailed descriptions and settings, please refer to the full PDF manual.

Multiple Charging and Output Modes Diagram
Figure 6: Diagram illustrating multiple charging and output modes.

5. Maintenance

5.1 Clearance and Maintenance for Anti-Dust Kit

Every inverter is installed with an anti-dust kit from the factory. The inverter automatically detects this kit and activates an internal thermal sensor to adjust the internal temperature. This kit also keeps dust out of your inverter and increases product reliability in harsh environments.

  1. Loosen the screw in a counterclockwise direction on the top of the inverter.
  2. Remove the dustproof case and take out the air filter foam.
  3. Clean the air filter foam and dustproof case. After cleaning, re-assemble the dust-kit back to the inverter.

NOTICE:

The anti-dust kit should be cleaned every one month.

6. Troubleshooting

This section provides common problems, their possible causes, and recommended solutions. If errors persist after following these steps, please contact your local dealer or service center for maintenance.

ProblemLCD/LED/BuzzerExplanation / Possible causeWhat to do
Unit shuts down automatically during startup process.LCD/LEDs and buzzer will be active for 3 seconds and then complete off.The battery voltage is too low (<1.91V/Cell)1. Re-charge battery.
2. Replace battery.
No response after power on.No indication.1. The battery voltage is far too low. (<1.4V/Cell)
2. Internal fuse tripped.
1. Contact repair center for replacing the fuse.
2. Re-charge battery.
3. Replace battery.
Input voltage is displayed as 0 on the LCD and green LED is flashing.Input protector is trippedCheck if AC breaker is tripped and AC wiring is connected well.
Mains exist but the unit works in battery mode.Green LED is flashing.Insufficient quality of AC power. (Shore or Generator)1. Check if AC wires are too thin and/or too long.
2. Check if generator (if applied) is working well or if input voltage range setting is correct. (UPS/Appliance)
Green LED is flashing.Set "Solar First" as the priority of output source.Change output source priority to Utility first.
When the unit is turned on, internal relay is switched on and off repeatedly.LCD display and LEDs are flashingBattery is disconnected.Check if battery wires are connected well.
Fault code 07Overload error. The inverter is overload 110% and time is up.Reduce the connected load by switching off some equipment.
Output short circuited.Check if wiring is connected well and remove abnormal load.
Fault code 05Temperature of internal converter component is over 120°C.Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.
Fault code 02Internal temperature of inverter component is over 100°C.Return to repair center.
Buzzer beeps continuously and red LED is on.Fault code 03Battery is over-charged.Check if specifications and quantity of batteries are met.
The battery voltage is too high.Replace battery.
Fault code 01Fan faultReplace the fan.
Fault code 06/58Output abnormal (Inverter voltage below 190Vac or is higher than 260Vac)1. Reduce the connected load.
2. Return to repair center.
Fault code 08/09/53/57Internal components failed.Return to repair center.
Fault code 51Over current or surge.Restart the unit, if the error happens again, please return to repair center.
Fault code 52Bus voltage is too low.
Fault code 55Output voltage is unbalanced.

Inverter protection features
Figure 7: Inverter's 360° protection system.

7. Specifications

7.1 Line Mode Specifications

INVERTER MODEL4.2KW6.2KW
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage230Vac
Low Loss Voltage170Vac±7V (UPS); 90Vac±7V (Appliances)
Low Loss Return Voltage180Vac±7V (UPS); 100Vac±7V (Appliances)
High Loss Voltage280Vac±7V
High Loss Return Voltage270Vac±7V
Max AC Input Voltage300Vac
Nominal Input Frequency50Hz / 60Hz (Auto detection)
Low Loss Frequency40±1Hz
Low Loss Return Frequency42±1Hz
High Loss Frequency65±1Hz
High Loss Return Frequency63±1Hz
Output Short Circuit ProtectionCircuit Breaker
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)

7.2 Inverter Mode Specifications

INVERTER MODEL4.2KW6.2KW
Rated Output Power4.2KW6.2KW
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac±5%
Output Frequency50Hz
Peak Efficiency93%
Overload Protection3s@≥150% load; 30s@101%~150% load
Surge Capacity2* rated power for 3 seconds
Nominal DC Input Voltage24Vdc48Vdc
Cold Start Voltage23.0Vdc46.0Vdc
No Load Power Consumption25W50W

7.3 Two Load Output Power

INVERTER MODEL4.2KW6.2KW
Full Load4200W6200W
Maximum Main Load4200W6200W
Second Load Range840W~2940W1240W~4340W
Main Load Cut Off Voltage22VDC44VDC
Main Load Return Voltage26VDC52VDC

7.4 Charge Mode Specifications

INVERTER MODEL4.2KW6.2KW
Utility Charging Mode
Charging Algorithm3-Step
AC Charging Current (Max)100Amp (@VI/P=230Vac)
Bulk Charging Voltage (Flooded Battery)29.258.4
Bulk Charging Voltage (AGM / Gel Battery)28.256.4
Floating Charging Voltage27Vdc54Vdc
MPPT Solar Charging Mode
Max. PV Array Power6200W8000W
Nominal PV Voltage240Vdc360Vdc
PV Array MPPT Voltage Range60Vdc~450Vdc
Max. PV Array Open Circuit Voltage500Vdc
Max Charging Current (AC charger plus solar charger)120Amp

7.5 General Specifications

INVERTER MODEL4.2KW6.2KW
Safety CertificationCE
Operating Temperature Range-10°C to 50°C
Storage temperature-15°C~60°C
Humidity5% to 95% Relative Humidity (Non-condensing)
Dimension (D*W*H), mm423×344×112
Net Weight, kg7.28.2

7.6 Approximate Back-up Time Table

For detailed backup time estimations based on load and battery capacity, please refer to the full PDF manual. Note that backup time depends on the quality, age, and type of battery.

8. User Tips

  • Voltage Stabilization: The inverter provides an output voltage regulation of 230Vac±5% in inverter mode, which offers a degree of voltage stabilization for connected appliances. However, it is not a dedicated voltage stabilizer and its primary function is power conversion and management.
  • Battery Compatibility: Ensure you select the correct battery type in the LCD settings (Program 05) for optimal performance and safety, especially for Lithium-ion batteries which may require BMS communication.
  • Monitoring: Utilize the optional Wi-Fi or GPRS modules and the 'SMARTESS' app for remote monitoring of your inverter's status and performance.

9. Warranty and Support

This product comes with a 1-year warranty.

For technical support, service, or warranty claims, please contact:

SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
Tel/Fax: +86755-28219903
Email: support@powmr.com
Web: www.powmr.com
Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

For a complete and detailed user manual, please refer to the official PDF document: PowMr Hybrid Inverter User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.