1. Introduction
The JIKONG V20 Smart BMS (Battery Management System) is an intelligent protection board designed for large capacity series lithium battery packs. It offers comprehensive management and protection features to ensure the safety and longevity of your battery system.

Image: JIKONG Smart BMS V20 Version highlighting APP support for iOS/Android/HarmonyOS, various functions (BT/RS485/UART/Display/HEAT/CANBUS/ACC/Parallel), Active Balanced Method, 0.6A Balance Current, and compatibility with 8S-32S Li-ion/LiFePo4/LTO Battery Types.
Key functionalities include voltage acquisition, high current active balancing, overcharge, over-discharge, overcurrent, and over-temperature protection. It also features a coulomb meter, Bluetooth communication, and optional GPS remote capabilities. This BMS is compatible with LiFePo4, ternary lithium (Li-ion), and LTO battery types.
Utilizing energy transfer active balancing technology, the BMS achieves a continuous balance current of 0.6A to 1A, significantly improving battery consistency, extending range, and delaying battery aging. A dedicated mobile application (available for Android and iOS) allows users to monitor battery status, modify parameters, and control charge/discharge switches via Bluetooth. Its compact size, ease of operation, and full functionality make it suitable for a wide range of applications, including electric vehicles, energy storage systems, and industrial equipment.

Image: Wide range of application scenarios for the JIKONG BMS, including E-bikes, Electric Tricycles, Low Speed Quads, Forklifts, Cleaning Cars, Tourist Cars, Industrial Drones, Scooters, RV Energy Storage, Lithium Batteries, Power Banks, and Storage Batteries.
Video: JIKONG Active Balance BMS overview, demonstrating balanced cell voltage difference improvement, 24-hour real-time balancing, 0A~2A balanced current, smart management via Bluetooth, compatibility with various string numbers, and 6 major protection features.
1.1. Key Features and Protections
The JIKONG Smart BMS integrates a rich set of features and six security protections to safeguard your battery system:

Image: Diagram illustrating the rich interfaces of the JIKONG BMS, including CAN, RS485, BT (Bluetooth), NTC, LCD, HEAT, Soft Switch, SOC Indicator, Key Switch, Active Equalizer, and ACC. It also shows customized interfaces for Heating, Temperature, Balance with Acquisition, Parallel, Buzzer, UART, RS485/CAN, ACC, and Display.

Image: Overview of the six security protections provided by the JIKONG BMS: Overcharge Protection (prevents over-charging, affects battery life), Short Circuit Protection (automatic protection), Over Discharge Protection (prevents battery from running out), Overcurrent Protection (prevents current from exceeding battery range), ALL-IN Protection (prevents cable drop or poor contact), and Over Temp Protection (prevents battery from over-heating).

Image: Diagram showing the six security protections in action with battery cells: Overcharge Protection, Short Circuit Protection, Over Discharge Protection, Overcurrent Protection, Balance Protection, and Over Temperature Protection.
2. Specifications
The JIKONG V20 Smart BMS is available in different configurations, primarily distinguished by continuous charge/discharge current ratings (100A and 150A). Below are the general specifications and default parameters.
General Product Specifications
| Feature | Specification |
|---|---|
| Brand Name | JIKONG (SMART JKBMS) |
| Type | LIFEPO4 Battery BMS, Active Balanced BMS |
| Usage Scenario | Power BMS, 3C Digital BMS |
| Battery Type Compatibility | Li-ion / LiFePo4 / LTO |
| Battery Strings | 7S-32S (Li-ion/LiFePo4), 12S-32S (LTO) |
| Working Voltage Range | 20-130V |
| Balance Method | Active Balance |
| Balance Current | 0.6A (Default) |
| Charge/Discharge Port | Common Port BMS |
| Continuous Discharge Current | 100A (for 10P model), 150A (for 15P model) |
| Continuous Charge Current | 100A (for 10P model), 150A (for 15P model) |
| Maximum Instantaneous Current | 200A (for 10P model), 300A (for 15P model) |
| Conductive Resistance in Main Circuit | 0.9mΩ |
| Internal Loop Resistance | 1.532 mΩ (100A), 0.895 mΩ (150A) |
| Operating Power Consumption | ≤1050 mW |
| Operating Temperature | -30°C to 70°C |
| Temperature Sensor | Yes (NTC) |
| Communication Interfaces | BT (Bluetooth), RS485, UART, CAN (optional), LCD (optional) |
| Protection Functions | Overcharge, Over Discharge, Overcurrent, Short Circuit, Over Temperature, Low Temperature |
| BMS Dimensions (L*W*H) | 251.3mm * 101.5mm * 15.6mm |
| Finished Weight | 708g (100A), 710g (150A) |
| Certifications | CE, FCC, RoHS |
Default Parameters
| Parameter | Li-ion (Default) | LiFePo4 (Default) | LTO (Default) | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Maximum Balancing Current | 1 | 1 | 1 | A |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 30 | 30 | 30 | S |
| Charging Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-circuit Protection Delay | 5 | 5 | 5 | uS |
| Charging Overtemperature Protection | 70 | 70 | 70 | °C |
| Charging Overtemperature Restore | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection | -20 | -20 | -20 | °C |
| Charging Low Temperature Restore | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection | 100 | 100 | 100 | °C |
| MOS Overtemperature Recovery | 80 | 80 | 80 | °C |
| Discharge Precharge Time | 5 | 5 | 5 | S |

Image: Detailed product specification table for JK-BD6A32S-10P and JK-BD6A32S-15P models, including number of battery strings, balance method, current ratings, and protection functions. Also shows a general wiring diagram for Load and Charger connections.

Image: Product dimensions for the JIKONG BMS, showing length (251mm), width (102mm), and thickness (15.6mm).

Image: Certificates of Compliance for RoHS, FCC, and CE, indicating the product meets international safety and environmental standards.
3. Setup and Installation
Proper installation and wiring are crucial for the safe and effective operation of your JIKONG Smart BMS. Please follow these instructions carefully.
3.1. Packing List
Before beginning installation, please verify that all components are present in your package:

Image: Packing list for the JIKONG BMS, including 1x BMS (251.3*101.5*15.6mm), 1x NTC (long 40cm), 1x Switch (long 50cm), 4x M6 Screws, 1x CANBUS line (long 28cm), 3x Sampling lines (long 75cm), 1x Heating line (long 17cm), and a Packing Box.
3.2. Wiring Diagram
The following diagram illustrates the general wiring method for the JK-BD6A32S-10P/15P series protection board, suitable for 7-32 series lithium battery packs. Ensure all connections are secure and correct before powering on.

Image: Wiring diagram for the JIKONG BMS (JK-BD6A32S-10P/15P-32S), showing connections for Load, Charger, Protection board heating wire, Heater element, Temperature control switch, Temperature probe, and battery cells (B+ to B-).
Important Wiring Notes:
- Ensure that the last power cord (B+) is connected to the main positive pole of the battery.
- The total voltage of the battery pack must be greater than 20V (for default BMS) or 10V (for 4S BMS) before initial startup.
- Verify that the balance cable connections are correct and that P- and B- are correctly connected.
- Ensure the protection board is securely fixed to the battery core.
3.3. Connector Definitions
The BMS features various connectors for different functions. Refer to the table below for detailed pin definitions:
| Connector | Pin No. | Name | Definition |
|---|---|---|---|
| P1 (HY2.0-15P) Balance & Acquisition Interface | 1 | B- | Total negative battery |
| 2 | B1 | The first battery positive | |
| ... | ... | ... | |
| 15 | B14 | The fourteenth battery positive | |
| P2 (HY2.0-11P) Balance & Acquisition Interface | 1 | B15 | The fifteenth battery positive |
| ... | ... | ... | |
| 9 | B23 | The twenty-third battery positive | |
| P3 (HY2.0-8P) Balance & Acquisition Interface | 1 | B26 | The twenty-sixth battery positive |
| ... | ... | ... | |
| 7 | B32 | The thirty-second battery positive | |
| 8 | B+ | Protection board power supply, connected to the battery | |
| P4 (HY2.0-4P) 4 External Temperature Sensor Interface | 1 | T3A | Third temperature sensor pin A |
| 2 | T3B | Third temperature sensor pin B | |
| 3 | T4A | Fourth temperature sensor pin A | |
| 4 | T4B | Fourth temperature sensor pin B | |
| P5 (HY2.0-4P) Temperature Interface | 1 | T1A | First temperature sensor pin A |
| 2 | T1B | First temperature sensor pin B | |
| 3 | T2A | Second temperature sensor pin A | |
| 4 | T2B | Second temperature sensor pin B | |
| P6 (M3-PCB Terminals) Heating Interface | 1 | HT- | Heater element negative electrode |
| P7 (A1254WF-2A) Buzzer Interface | 1 | GND | Buzzer power negative |
| 2 | VCC | Buzzer power supply positive | |
| P8 (1.25T-4PWT) UART Interface | 1 | GND | Power/signal ground |
| 2 | RX | UART_RX, 3.3V | |
| 3 | TX | UART_TX, 3.3V | |
| 4 | VGPS | Power output, voltage close to B+ | |
| P9 (A1254WF-4A) Communication Interface | 1 | CAN_L | CAN signal negative terminal |
| 2 | CAN_H | CAN signal positive terminal | |
| 3 | RS485_A | RS485 signal positive terminal | |
| 4 | RS485_B | RS485 signal negative terminal | |
| P10 (A1254WF-6A) Display Interface | 1 | K- | Activation signal negative electrode |
| 2 | K+ | Activate the positive signal | |
| 3 | GND | Power negative terminal | |
| 4 | B | Display RS485 signal negative | |
| 5 | A | Display RS485 signal positive | |
| 6 | VCC | Display power output | |
| P11 (A1254WF-7A) ACC Interface | 1 | 5V+ | Internal 5V (+) |
| 2 | CD+ | Positive Terminal of Charge Enable Signal | |
| 3 | CD- | Negative Terminal of Charge Enable Signal | |
| 4 | NULL | Null | |
| 5 | ACC- | Discharge Enable Signal Negative | |
| P12 (A1254WF-3A) Parallel Interface | 1 | P-status | Parallel module status signal |
| 2 | P-EN | Parallel module enable signal, output low level Turn on parallel module | |
| 3 | GND | Signal ground |
Image: Schematic diagram of the JK-BD6A32S-10P/8P connector, illustrating the physical layout of the connectors on the BMS board.

Image: Top-down view of the JIKONG BMS board, highlighting the various connectors and their labels (P-, B-, B+, etc.) for wiring reference.
3.4. APP Installation and Activation
The JIKONG Smart BMS is managed via a mobile application. To install the app:
- Scan the QR code below to download the official JIKONG BMS app. (Android Version 7 minimum is required for the Android APP).
- Alternatively, search for "JIKONG BMS" in the Apple App Store (for iOS) or "JK BMS" in the Google Play Store (for Android).

Image: QR code for downloading the JIKONG BMS mobile application.
Device Activation:
- After connecting all wires, power on the protection board. The BMS is designed for charging activation mode; the charger voltage must be 2V higher than the battery voltage to activate.
- Alternatively, if equipped with a display screen and button, insert the display cable into the interface and press the button to activate.
- Ensure your mobile phone's Bluetooth is turned on. Open the APP, click the top left corner to search for devices, and connect to the device name using the default password:
1234.
4. Operating Instructions
The JIKONG Smart BMS offers a range of intelligent functions to manage and protect your battery pack. Most functions are configurable and monitored via the mobile application.
4.1. APP Operation Overview
The mobile APP provides real-time monitoring and control over your BMS. After connecting via Bluetooth (default password: 1234), you can:
- View battery working status (voltage, current, temperature, etc.).
- Modify various working parameters of the protection board.
- Control charge and discharge switches.
- Set the number of strings and battery type (Li-ion, LiFePo4, LTO) during initial setup.

Image: Screenshots of the JIKONG BMS mobile APP interface, showing device list, real-time data display (voltage, balance status, temperature), basic settings, advanced settings, and modification options for battery type and parameters.
The APP displays the highest voltage in blue and the lowest voltage in red for easy identification of cell imbalances.
4.2. LCD Display (Optional)
For models equipped with an LCD display, you can view key battery information directly on the screen. The display typically shows voltage, current, state of charge (SOC), and error codes.

Image: JIKONG 2.3 inch LCD Display showing battery status, voltage, current, and error codes. It comes with an active switch and a 50cm cable, with an optional 300cm extend cable.
4.3. Smart Energy Working Mode Switching
The BMS intelligently switches between different working modes to optimize energy management and battery protection:

Image: Diagram illustrating the smart energy working mode switching of the JIKONG BMS, including Storage Mode (low power consumption), Normal Working Mode (full functionality when charger is inserted), Standby Mode (automatic entry after set time if no charge/discharge), and Shutdown Mode (automatic shutdown below shutdown voltage or to prevent power waste).
- Storage Mode: In transportation, storage, or wireless transmission off mode, the BMS is in storage mode, which does not consume battery pack current.
- Normal Working Mode: When the charger is inserted in the storage mode and off mode, the BMS will immediately return to the normal working mode, and all the protection functions, equalization functions and communication functions will return to normal working.
- Standby Mode: When the battery pack is in the static state (no charge and discharge current and no equilibrium current), the BMS will automatically enter the standby state after the set time (1-30 days can be set) is exceeded.
- Shutdown: To prevent the BMS from wasting power for a long time and damaging the battery pack, the BMS has an automatic shutdown voltage, and the BMS automatically shuts down when a cell falls below the shutdown voltage.
4.4. Active Balancing
The BMS employs active equalization to transfer energy from high-voltage cells to low-voltage cells, ensuring battery consistency. Users can set the balance trigger pressure difference (in mV) in the APP. Balancing automatically activates when the voltage difference between any two strings exceeds the set value and turns off when it falls below. The default balance current is 0.6A/1A. If not needed, the balancing function can be disabled in the APP.
4.5. Heating Function (Optional)
For models with the "Heat" configuration, the BMS supports an optional heating function to prevent performance degradation in low temperatures. This uses a resistance heater or heating film to warm the battery. The designed heating current is 10A. Users can control this function via the APP based on ambient temperature. It is recommended to use a normally closed temperature switch (45°C to 65°C) in series with the heating circuit as a secondary protection.
Heating Conditions:
- Battery temperature is lower than the low-temperature protection temperature for charging.
- Connecting an external heating film will activate heating via the APP, consuming battery power.
- Heating via the charger depends on the protection board hardware and charger compatibility.
4.6. ACC/Charger Detection (Optional)
This function enables discharge and charge based on ACC and charger signals. Two methods are available for enabling discharge (applying 4.5V-15V between ACC+ and ACC- or shorting ACC+ to 5V+) and charging (applying 4.5V-15V between CD+ and CD- or shorting CD+ to 5V+). Only one method should be used for each.
4.7. Alarm Function (Optional)
For models with alarm functionality, the BMS will trigger an external alarm when it detects safety risks such as over-temperature, overcharge, or over-discharge.
4.8. Battery Pack Parallel Function (Optional)
This function supports parallel connection of battery packs, suitable for energy storage applications. It requires synchronous use with parallel modules and disabling the "charging current limiting" function in the APP.
4.9. Discharge Precharge Function (Optional)
The BMS can be configured with a discharge precharge function. The default precharge time is 5 seconds. Users can enable or disable this function as needed; setting the time to 0 disables it.
4.10. Intelligent Sleep (Standard)
The intelligent sleep function allows the BMS to enter a low-power state when the charging and discharging current is less than 1A for 26 consecutive hours. This reduces the BMS's own energy consumption. It can be reactivated by pressing a button (if equipped) or by connecting a charger.
4.11. Communication Functions (Optional)
The BMS supports optional CAN and RS485 communication. Users can configure the address and communication protocol via the APP. A reserved UART interface also allows for optional GPS module configuration for battery positioning.
5. Maintenance
To ensure the optimal performance and longevity of your JIKONG Smart BMS and battery pack, regular maintenance is recommended:
- Regular Monitoring: Periodically check the battery status and parameters via the mobile APP to identify any anomalies early.
- Cleanliness: Keep the BMS board and connectors clean and free from dust, moisture, and corrosive substances. Use a soft, dry cloth for cleaning.
- Connection Integrity: Periodically inspect all wiring and connectors for looseness, corrosion, or damage. Ensure all connections are tight and secure.
- Software Updates: Check for and install any available firmware or APP updates to benefit from improved features and bug fixes.
- Environmental Conditions: Operate the BMS within its specified temperature range (-30°C to 70°C). Avoid extreme temperatures and high humidity.
- Storage: If the battery pack with the BMS is to be stored for an extended period, ensure it is in a safe, dry place and consider activating the intelligent sleep function to minimize power consumption.
6. Troubleshooting
This section provides solutions to common issues you might encounter with your JIKONG Smart BMS.
6.1. Common Issues and Solutions

Image: FAQ section from the manual, detailing troubleshooting steps for issues like "Do not turn on", "Inaccurate voltage", "Inaccurate current", "Inaccurate capacity", and "The designed string number is inconsistent with the actual string number".
- BMS Does Not Turn On:
- Ensure the last "B+" line of the cable is connected to the positive pole of the battery.
- Start up after charging and ensure the charger voltage is greater than 4V of the battery pack voltage.
- Check if the charger has voltage output.
- Inaccurate Voltage Reading:
Measure the actual total pressure of the battery pack with a multimeter and input this value into the "voltage calibration" setting on the parameter setting page in the APP.
- Inaccurate Current Reading:
The B- and P- of the protection board use two 7AWG wires, which need to be connected in parallel. Otherwise, it will lead to current error. Measure the actual current of the battery pack with a clamp meter and input this value into the "current calibration" setting on the parameter setting page. A larger actual current will result in higher calibration accuracy.
- Inaccurate Capacity:
An initial capacity estimated based on monomer voltage when the protection board is first powered on is inaccurate. After the protection board is discharged to the cut-off voltage and then fully charged, the capacity will be calibrated. The charging process must not be interrupted during this calibration.
- Designed String Number Inconsistent with Actual String Number:
- Check if the "unit quantity" in the parameter setting is correct.
- If there is no voltage in two or more strings in the middle, check if the acquisition cable has fallen off.
7. User Tips
- Initial Setup: Always double-check all wiring connections, especially the B+ and B- terminals, before powering on the BMS for the first time. Incorrect wiring can cause damage.
- APP Customization: Take advantage of the mobile APP to fine-tune parameters like balance trigger voltage, protection thresholds, and heating settings to match your specific battery chemistry and usage patterns.
- Cold Weather Operation: If operating in cold environments, ensure your BMS model supports the heating function and utilize it to maintain optimal battery performance and prevent low-temperature charging issues.
- Regular Checks: Periodically review the real-time data in the APP to catch any potential issues with individual cells or overall battery health before they become critical.
- Firmware Updates: Keep your BMS firmware updated to benefit from the latest features, improvements, and bug fixes.
8. Warranty and Support
JIKONG products are designed for reliability and performance. For any technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact JIKONG customer support. Ensure you have your product model and purchase details ready for efficient service.
For further documentation, including a detailed user manual in PDF format, please refer to the official JIKONG resources. A PDF version of the user manual is available here.