yieryi THE01888S-RS485

Contents

Yieryi RS485 Soil Multi-Parameter Sensor User Manual

Model: THE01888S-RS485 | Brand: Yieryi

1. Introduction

The Yieryi THE01888S-RS485 is a state-of-the-art 7-in-1 soil multi-parameter sensor designed for comprehensive soil analysis. This robust device accurately measures soil temperature, volumetric water content (moisture), electrical conductivity (EC), pH value, nitrogen (N), phosphorus (P), potassium (K), and salinity. Equipped with RS485 Modbus-RTU protocol and an IP68 waterproof rating, it offers high accuracy, fast response, and durable performance, making it ideal for various applications in farming, gardening, greenhouses, and scientific research.

Yieryi RS485 Soil Multi-Parameter Sensor showing 8-in-1 measurement capabilities

Figure 1: Yieryi RS485 Soil Multi-Parameter Sensor with its 8-in-1 measurement capabilities.

Diagram illustrating the eight parameters measured by the soil sensor

Figure 2: Visual representation of the eight soil parameters measured by the sensor.

2. Specifications

Table of detailed measurement parameters, ranges, accuracy, resolution, and physical specifications of the soil sensor

Figure 3: Detailed specifications of the THE01888S-RS485 Soil Multi-Parameter Sensor.

General Specifications:

  • Model Number: THE01888S-RS485
  • Brand Name: yieryi
  • Origin: Mainland China
  • Display Type: DIGITAL (when connected to a display unit)
  • Certification: CE
  • Is Smart Device: Yes
  • With Backlight Or Not: Yes (when connected to a display unit)
  • Battery Included: No
  • High-concerned chemical: None

Measurement Parameters:

  • Soil Temperature
  • Soil Volumetric Water Content
  • Soil Electrical Conductivity (EC)
  • Soil PH Value
  • Soil Nitrogen (N)
  • Phosphorus (P)
  • Potassium (K)
  • Soil Salinity

Performance:

  • Output Signal: RS485 (Standard Modbus-RTU Protocol)
  • Default Device Address: 01
  • Communication Parameters: Baud Rate 9600; Parity Bit None; Data Bits 8; Stop Bits 1
  • Key Features: Isolation Function, High Accuracy, Fast Response, Good Sealing, Wide Application Range, Interchangeable

Physical Characteristics:

  • Probe Length: 55mm
  • Probe Diameter: 3mm
  • Probe Material: 316L Stainless Steel
  • Sealing Material: ABS Engineering Plastic + Epoxy Resin
  • Waterproof Rating: IP68
  • Cable Specification: Standard 2 Metres (Customizable up to 1200 Metres)
  • Dimensions: 128mm (length) x 46mm (width) x 10mm (thickness of main body), 56mm (probe length)
Diagram showing the dimensions of the soil sensor and its 2-meter cable

Figure 4: Physical dimensions of the sensor and cable length.

3. Package Contents

Upon opening your package, please verify that all items are present and in good condition:

  • 1 × THE01888S-RS485 Soil Multi-Parameter Sensor
  • 1 × User Manual

4. Setup and Connection

The Yieryi RS485 Soil Multi-Parameter Sensor utilizes the Modbus-RTU protocol via an RS485 interface for data transmission. It can be integrated into various monitoring systems.

Power Supply:

The sensor requires a 9-24V DC power supply. Ensure the power source is stable and within the specified voltage range.

Wiring Connections:

The sensor typically comes with a multi-core cable for connection. The standard wiring for RS485 communication involves:

  • Power (VCC): Connect to the positive terminal of the 9-24V DC power supply.
  • Ground (GND): Connect to the negative terminal of the 9-24V DC power supply.
  • RS485 A (Data+): Connect to the A terminal of your RS485 interface.
  • RS485 B (Data-): Connect to the B terminal of your RS485 interface.

Connection Scenarios:

The sensor can be connected in single or multiple configurations to various devices:

System Framework Diagram showing single and multiple sensor connections to PLC, microcontroller, and computer via RS485 to USB

Figure 5: System Framework Diagram for single and multiple sensor connections.

  1. Single Connection: The sensor can be directly connected to a PLC (Programmable Logic Controller) or a microcontroller. For PC monitoring, an RS485 to USB converter is required.
  2. Multiple Connections: Multiple sensors can be combined on a single RS485 bus. Theoretically, one bus can accommodate up to 254 RS485 sensors. Each sensor must have a unique device address (default is 01, but can be changed). The bus can then connect to a PLC, microcontroller, or a PC via an RS485 to USB converter.

PC Software Connection:

For real-time monitoring on a computer, you will need an RS485 to USB converter and compatible upper computer software (customer-provided).

Diagram showing connection of RS485 sensor to PC via 485 to USB converter for real-time monitoring

Figure 6: Connecting the RS485 sensor to a PC for real-time monitoring.

The sensor configuration tool provided by Yieryi can be used for configuration and testing. Note that only one device can be connected when using this configuration software.

5. Operating Instructions

The sensor offers two primary methods for taking measurements:

Diagram illustrating rapid measurement and buried surveying methods for the soil sensor

Figure 7: Rapid measurement and buried surveying methods.

Rapid Measurement Method:

  1. Select a suitable measurement location, avoiding rocks and similar hard objects.
  2. Excavate the surface soil according to the required measurement depth.
  3. Maintain the original looseness of the soil below.
  4. Grip the sensor tightly and insert it vertically into the soil.
  5. Do not shake it left or right during insertion.
  6. It is recommended to calculate the average of multiple readings within a small range of one measurement point for better accuracy.

Buried Surveying Method:

  1. Dig a pit with a diameter greater than 20cm vertically.
  2. Insert the sensor steel needle into the pit according to the measurement needs.
  3. Fill and compact the pit to ensure the steel needle is in close contact with the soil.
  4. Allow the sensor to stabilize for a period of time.
  5. Continuous long-term measurement and recording can then be carried out.

Data Transmission and Viewing:

The sensor data can be accessed and monitored through various platforms:

Diagrams showing data transmission to mobile phones, computers, and tablets via network collector or environmental monitoring host

Figure 8: Data transmission and viewing options.

  • Via Network Collector: The device can be uploaded to a free cloud platform through a network collector (which can monitor 8 elements) to achieve remote real-time monitoring on mobile phones, computers, and tablets.
  • Via Environmental Monitoring Host: Alternatively, it can be uploaded to a free cloud platform through an environmental monitoring host (which can monitor 32 elements) for remote real-time monitoring.
  • Via PC Software: As described in the Setup section, connect the RS485 sensor to a PC via a 485 to USB converter and use customer-provided upper computer software for real-time monitoring.
  • Via Microcontroller/PLC: The equipment can view data through the customer's own microcontroller or PLC using the Standard Modbus RTU protocol.

Video 1: Demonstration of the soil sensor in use, showing connection to a smartphone and real-time data monitoring via an app.

6. Precautions

To ensure accurate readings and prolong the life of your sensor, please observe the following precautions:

Six visual precautions for using the soil sensor, including proper insertion, avoiding direct sunlight, ensuring soil moisture, waterproofing, stabilization time, and cleaning

Figure 9: Important precautions for sensor usage.

  1. The steel needle must be fully inserted into the soil during measurement.
  2. Avoid direct exposure of strong sunlight to the transmitter, which may cause excessive temperature. Pay attention to lightning protection when using outdoors.
  3. When measuring parameters such as pH, conductivity, nitrogen, phosphorus, and potassium, it is necessary to keep the soil moist (at least 20%).
  4. The transmitter has a protection level of IP68 and can be completely submerged in water.
  5. After inserting the sensor into the soil, it cannot immediately read the value. The value can only be read after it stabilizes. The waiting time varies for different soils, and the data can only be read after it stabilizes after being inserted into the soil for about 3-5 minutes.
  6. Among the 4 probes, there is one probe with a dark color, which belongs to a special alloy and is prone to wear and tear. After use, the probe should be cleaned thoroughly.

7. Maintenance

Proper maintenance ensures the longevity and accuracy of your Yieryi soil sensor:

  • Cleaning: After each use, especially when measuring in different soil types or after buried surveying, thoroughly clean the steel probes. Use a soft cloth and clean water to wipe off any soil residue. Pay special attention to the dark-colored alloy probe.
  • Storage: Store the sensor in a clean, dry place away from direct sunlight and extreme temperatures when not in use.
  • Inspection: Periodically inspect the cable for any signs of damage, cuts, or fraying. Ensure the sensor body and probe connections are secure.
  • Calibration: While the sensor is designed for high accuracy, refer to your specific data acquisition system or software for any recommended calibration procedures.

8. Troubleshooting

Here are some common questions and troubleshooting tips for the Yieryi RS485 Soil Multi-Parameter Sensor:

Q: Can the sensor test moisture for various hay types like wheat straw and clover?
A: Yes, the sensor supports code selection (CD01-CD03) for wheat straw, clover, soapwort, and other hay types, allowing for specific moisture measurements.
Q: How can accurate readings be ensured in cold environments?
A: The sensor features built-in automatic temperature compensation, enabling it to adapt to temperatures ranging from -10°C to 60°C for stable and reliable results.
Q: Does the sensor have an auto power-off function?
A: Yes, the sensor automatically shuts off after 5 minutes of inactivity to conserve power. It also supports manual power-off at any time.
Q: Why are my readings unstable or inaccurate?
A: Ensure the steel probes are fully inserted into the soil and are in good contact. For pH, EC, and NPK measurements, the soil must be moist (at least 20%). Allow 3-5 seconds for the sensor to stabilize after insertion before taking a reading. Also, check for any physical damage to the probes or cable.
Q: The sensor is not communicating with my device.
A: Verify all wiring connections (VCC, GND, RS485 A, RS485 B) are correct. Check the power supply voltage (9-24V DC). Ensure the communication parameters (Baud Rate 9600, Parity Bit None, Data Bits 8, Stop Bits 1) are correctly configured on your receiving device. If using multiple sensors, confirm each has a unique Modbus address.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the seller or refer to the official Yieryi website. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.