Introduction
This manual provides essential information for the safe and efficient operation of your SUMRY NML series pure sine wave solar inverter. Please read this manual thoroughly before installation and use. The NML series is designed to convert DC power from solar panels or batteries into AC power for various home appliances and personal computers, offering reliable power solutions for off-grid or backup systems.
Key Features
- Pure sine wave solar inverter output, ensuring compatibility with sensitive electronics.
- Integrated 80A MPPT solar charger for efficient solar power utilization.
- Wide PV input voltage range (30-450VDC) for flexible solar panel configurations.
- Built-in anti-dust kit for enhanced durability and protection in harsh environments.
- Smart battery charge design to optimize battery performance and extend lifespan.
- Customizable settings to meet diverse user requirements and power management preferences.
- Prioritizes solar energy supply directly to the load, maximizing renewable energy use.
Image: Banner highlighting key features of the inverter.
Setup and Installation
Proper installation is crucial for the safe and efficient operation of your solar inverter. All wiring should be performed by a qualified electrician and comply with local electrical codes. Please follow these guidelines carefully.
1. System Overview

Image: Diagram illustrating the connection of solar modules, generator, utility grid, battery packs, and home appliances to the SUMRY NML solar inverter.
The diagram above shows a typical setup for the NML solar inverter. It can integrate power from solar modules, a generator, and the utility grid to charge battery packs and power home appliances, providing a versatile energy solution.
2. Physical Installation
Ensure the inverter is mounted in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Maintain adequate clearance around the unit for proper airflow to prevent overheating.



3. Electrical Connections
Refer to the system diagram and the rear view image for correct wiring. Always ensure power sources are disconnected before making any electrical connections.
- Battery Connection: Connect the battery bank to the inverter's battery terminals. Ensure correct polarity (positive to positive, negative to negative) to avoid damage.
- PV Input Connection: Connect the solar panel array to the PV input terminals. Observe the MPPT voltage range (30-450VDC) and maximum open circuit voltage (400VDC) to prevent overvoltage.
- AC Input Connection: Connect the utility grid or generator AC input to the inverter's AC input terminals.
- AC Output Connection: Connect your home appliances or load to the AC output terminals.
- Grounding: Ensure the inverter chassis is properly grounded according to local electrical codes for safety.
Operation
The inverter features an intuitive LCD display for monitoring system status and adjusting settings. Familiarize yourself with the display icons for effective operation.
LCD Display and Indicators

Image: Detailed explanation of the inverter's LCD display icons and their meanings.
| Icon/Indicator | Description |
|---|---|
| PV input | Indicates power input from solar panels. |
| AC input | Indicates power input from AC source (utility/generator). |
| Input Voltage, Input Frequency, PV Voltage, Battery Voltage, Charger Current | Displays various input and battery parameters. |
| Setting Programs | Used to navigate and adjust inverter settings. |
| Output Voltage, Output Frequency, Load Percent, Load in VA, Load in Watt, Discharging Current | Displays various output and load parameters. Flashing indicates a warning code. |
| Load Level | Visual representation of the current load on the inverter. |
| DC/AC Inverter Circuit is Working | Indicates the inverter is actively converting DC to AC. |
| Battery Level | Shows the current charge level of the battery. |
| Utility Charger Circuit is Working | Indicates the utility grid is charging the battery. |
| Unit Connects to the PV Panel | Indicates solar panels are connected and providing power. |
| Unit Connects to the Mains | Indicates the inverter is connected to the utility grid. |
| Load is Supplied by Utility Power | Indicates the load is currently being powered by the utility grid (bypass mode). |
| Unit Alarm is Disabled | Indicates that audible alarms are turned off. |
| Overload | Indicates the inverter is experiencing an overload condition. |
Power On/Off
- To Power On: Ensure all connections are secure. Press and hold the power button until the display illuminates and the system initializes.
- To Power Off: Disconnect all loads from the inverter. Press and hold the power button until the display turns off and the unit powers down completely.
Maintenance
Regular maintenance ensures the longevity and optimal performance of your SUMRY NML solar inverter. Perform these checks periodically:
- Cleaning: Periodically clean the exterior of the inverter with a dry, soft cloth. Ensure ventilation openings are free from dust and debris. The built-in anti-dust kit helps, but regular visual checks are recommended.
- Connection Checks: Annually check all electrical connections for tightness and signs of corrosion. Loose connections can lead to poor performance or safety hazards.
- Battery Health: Monitor battery voltage and performance regularly. Follow the battery manufacturer's guidelines for specific maintenance procedures and replacement schedules.
- Environmental Conditions: Ensure the operating environment remains within the specified temperature and humidity ranges (-10℃ to 50℃, 5%-95% non-condensing humidity) to prevent damage and ensure efficient operation.
Troubleshooting
If the inverter is not functioning as expected, refer to the LCD display for any flashing warning codes or overload indicators. The table below outlines common issues and their potential solutions:
- No Power/Display Off: Check battery connections for secure fit and correct polarity. Verify battery voltage is within the operational range. If using AC input, ensure the utility grid or generator is supplying power.
- Overload Indication: If the 'Overload' icon is displayed, reduce the connected load immediately. The inverter's surge power capacity is 4000VA for NML-2000-12 and 6400VA for NML-3200-24. Exceeding this can cause shutdown.
- Warning Codes: If the display is flashing with a warning code, consult the full product manual (if available) for specific code interpretations. These typically indicate issues with input voltage, frequency, or internal faults.
- No Solar Charging: Verify PV panel connections are secure. Ensure the PV input voltage is within the MPPT range (30-450VDC). Check for any shading on solar panels that might reduce output.
For persistent issues or problems not covered here, contact customer support.
Technical Specifications
Image: Banner indicating the technical parameters section.
| Parameter | VICTOR NML-2000-12 | VICTOR NML-3200-24 |
|---|---|---|
| RATED POWER | 2000VA/1600W | 3200VA/3000W |
| AC Input | ||
| Voltage | 230VAC | |
| Selectable Voltage Range (Personal Computers) | 170-280VAC | |
| Selectable Voltage Range (Home Appliances) | 90-280VAC | |
| Frequency Range | 50Hz/60Hz (Auto sensing) | |
| AC Output | ||
| AC Voltage Regulation | 230VAC ±5% | |
| Surge Power | 4000VA | 6400VA |
| Efficiency (Peak) PV to INV | 98% | |
| Efficiency (Peak) Battery to INV | 94% | |
| Transfer Time | 10ms | |
| BATTERY | ||
| Battery Voltage | 12V | 24V |
| Floating Charge Voltage | 13.5V | 27V |
| Overcharge Protection | 16V | 32V |
| SOLAR CHARGER & AC CHARGER | ||
| Solar Charger Type | MPPT | |
| Maximum PV Array Power | 3000W | |
| MPPT Range @ Operating Voltage | 30-450VDC | |
| Maximum PV Array Open Circuit Voltage | 400VDC | |
| Maximum Solar Charge Current | 80A | |
| Max Input Current | 1/13A | |
| Maximum AC Charge Current | 60A | |
| Maximum Charging Current (Solar+AC) | 80A | |
| PHYSICAL | ||
| Dimension, D*W*H (mm) | 357/273/95 | |
| Carton Dimension D*W*H (mm) | 435/335/165 | |
| Net WEIGHT (kgs) | 4.6 | 4.8 |
| Gross WEIGHT (kgs) | 5.6 | 5.8 |
| ENVIRONMENT | ||
| Humidity | 5%-95% Relative Humidity (Non-condensing) | |
| Operating Temperature | -10℃-50℃ | |
| STANDARD | ||
| Compliance Safety | CE | |
User Tips
To get the most out of your SUMRY NML solar inverter, consider the following user tips:
- Load Management: Always be mindful of the total power consumption of your connected appliances. Avoid connecting loads that exceed the inverter's rated power or surge capacity to prevent damage and ensure stable operation.
- Battery Sizing: Ensure your battery bank is adequately sized for your power consumption needs. A larger battery bank will provide longer backup time during outages or periods of low solar generation.
- Solar Panel Orientation: Optimize the angle and direction of your solar panels for maximum sunlight exposure throughout the day and across seasons. This will maximize energy harvest and charging efficiency.
- Regular Monitoring: Periodically check the LCD display for system status, battery charge, load levels, and any alerts. This proactive monitoring helps ensure continuous optimal performance and allows for early detection of potential issues.
- Ventilation: Keep the area around the inverter clear to ensure proper airflow. Good ventilation is essential for dissipating heat and maintaining the inverter's efficiency and lifespan.
Warranty and Support
The SUMRY NML Solar Inverter comes with a 1-year warranty. For technical support, warranty claims, or any inquiries, please contact your vendor or the manufacturer directly using the information below.
Contact Information:
- Whats-App: +86 158-0252-3190
- We-Chat: +86 158-0252-3190
- Email: 229-320-0068@qq.com
When contacting support, please provide your specific model number (e.g., VICTOR NML-2000-12 or VICTOR NML-3200-24) and purchase details to facilitate a quicker resolution.