Sumry MAX Series 8.2kw /10.2kw

Contents

Sumry MAX Series Hybrid Inverter User Manual

Models: 8.2kW / 10.2kW

1. Introduction

This manual provides essential information for the safe and efficient operation of your Sumry MAX Series Hybrid Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference. The MAX Series Hybrid Inverter is designed to integrate solar power, utility power, and battery power to provide continuous power supply.

Front view of the Sumry MAX Series Hybrid Inverter
Figure 1: Front view of the Sumry MAX Series Hybrid Inverter

2. Key Features

  • Pure sine wave solar inverter (on/off Grid capability)
  • Output power factor 1.0
  • Wi-Fi & GPRS available for iOS and Android monitoring
  • Inverter can operate without a battery
  • One-key restoration to factory settings
  • Built-in Lithium battery automatic activation
  • High PV input voltage range (90-500VDC)
  • Built-in anti-dust kit for harsh environments
  • Smart battery charge design to optimize battery life
  • Dual output capability
  • Dual PV input capability
  • Touch button interface
  • Built-in 160A MPPT solar charger (for 8.2kW and 10.2kW models)
  • On/Off Grid Work Mode
  • Dual communication ports for Battery communication and Wi-Fi communication

3. Installation and Connections

Proper installation is crucial for the safe and efficient operation of the inverter. It is recommended that installation be performed by a qualified electrician.

3.1 Rear Panel Connections Overview

Rear panel connections of the Sumry MAX Series Hybrid Inverter showing PV inputs, AC inputs/outputs, battery terminals, WiFi, RS232, and BMS ports.
Figure 2: Rear Panel Connections

The rear panel provides all necessary connection points for PV input, AC input/output, battery, and communication interfaces. Ensure all connections are secure and correctly polarized.

3.2 Mounting the Inverter

  • Choose a suitable location that is well-ventilated, dry, and away from direct sunlight or heat sources.
  • Ensure the mounting surface can support the weight of the inverter (approximately 16kg).
  • Allow sufficient clearance around the inverter for proper airflow and cooling.
  • Mount the inverter vertically using appropriate fasteners.

3.3 Wiring Instructions

  1. Battery Connection: Connect the battery bank to the BATTERY terminals, ensuring correct polarity (+ to + and - to -).
  2. PV Input Connection: Connect the solar panel arrays to the PV1 and PV2 input terminals. Observe correct polarity and ensure the PV voltage is within the specified MPPT range (90-450VDC) and maximum DC voltage (500VDC).
  3. AC Input Connection: Connect the utility grid power to the AC IN terminals.
  4. AC Output Connection: Connect your loads to the MAIN OUT and SECOND OUT terminals.
  5. Communication Connections: Connect Wi-Fi module, RS232, RS485, or BMS cables as required for monitoring and battery communication.

WARNING: All wiring must comply with local and national electrical codes. Disconnect all power sources before making any electrical connections.

4. Operation

The inverter features a user-friendly LCD display and touch buttons for monitoring and configuration.

4.1 LCD Display Overview

LCD display of the Sumry MAX Series Hybrid Inverter with numbered indicators and their descriptions.
Figure 3: LCD Display and Indicators

The LCD provides real-time status and operational data. Refer to the following key for understanding the display icons:

No.IconDescription
1PVPV input
2ACAC input
3INPUTBATTEMPInput voltage, input frequency, PV voltage, battery voltage, charger current
48.8Setting programs
58.8Flashing with warning code, lighting with fault code
6OUTPUTBATTLOADOutput voltage, output frequency, load percent, load in VA, load in watt and discharging current
7Load levelLoad level (e.g., 25%, 50%, 75%, 100%)
8DC/AC inverter circuit is workingDC/AC inverter circuit is working
9CHARGINGBattery level
10Utility charger circuit is workingUtility charger circuit is working
11Unit connects to the PV panelUnit connects to the PV panel
12Unit connects to the mainsUnit connects to the mains
13BYPASSLoad is supplied by utility power
14Unit alarm is disabledUnit alarm is disabled
15OVER LOADOverload

4.2 Basic Operation

  • Power On/Off: Use the main power button (usually located on the front or side) to turn the inverter on or off.
  • Mode Selection: The inverter supports various operating modes (e.g., Grid-tie with backup, Off-grid, Battery priority). These modes can typically be configured via the LCD panel or monitoring software.
  • Monitoring: Use the Wi-Fi/GPRS module and associated app (iOS/Android) to monitor the inverter's performance, battery status, and energy flow remotely.

5. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

  • Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris. The built-in anti-dust kit helps in harsh environments, but regular checks are still recommended.
  • Connection Checks: Annually inspect all electrical connections (PV, AC, Battery) for tightness and signs of corrosion.
  • Battery Health: If using external batteries, monitor their health and charge cycles. The smart battery charge design helps optimize battery life.
  • Software Updates: Keep the inverter's firmware updated as recommended by the manufacturer to ensure optimal performance and access to new features.

CAUTION: Disconnect all power sources before performing any maintenance or cleaning.

6. Troubleshooting

This section provides basic troubleshooting steps for common issues. For more complex problems, contact technical support.

ProblemPossible CauseSolution
Inverter not powering onNo AC input, battery disconnected, or low battery voltage.Check AC input connection, ensure battery is connected and charged, verify main power switch is ON.
No power output to loadsOverload, fault condition, or output breaker tripped.Reduce load, check LCD for fault codes (icon 5), reset output breaker.
PV input not detectedPV panels disconnected, low PV voltage, or fault in PV array.Check PV connections and polarity, ensure sufficient sunlight, verify PV voltage is within operating range.
Overload warning (icon 15)Connected loads exceed inverter's capacity.Immediately reduce the connected load.
Communication issues (Wi-Fi/BMS)Loose cable, incorrect settings, or network problem.Check communication cable connections, verify Wi-Fi network, consult app instructions for settings.

If the problem persists after attempting these solutions, please contact customer support.

7. Technical Specifications

Detailed specifications for the Sumry MAX Series Hybrid Inverter models.

MODELMAX 8.2KWMAX 10.2KW
Phase1-phase
Maximum PV Input Power5400W+5400W
Rated Output Power8200W/8200VA10200W/10200VA
Maximum Solar Charging Current160A160A
GRID-TIE OPERATION
PV Input (DC)
Nominal DC Voltage / Maximum DC Voltage360VDC/500VDC
Start-up Voltage / Initial Feeding Voltage90VDC/120VDC
MPPT Voltage Range90VDC~450VDC
Number of MPPT Trackers / Maximum Input Current2/28A
GRID OUTPUT (AC)
Nominal Output Voltage220/230/240VAC
Output Voltage Range195~253VAC
Nominal Output Current35.6A44.3A
Power Factor>0.99
Feed-in Grid Frequency Range49~51±1Hz
EFFICIENCY
Maximum Conversion Efficiency (DC/AC)98%
TWO LOAD OUTPUT POWER
Full Load8200W10200W
Maximum Main Load8200W10200W
Maximum Second Load (battery mode)2733W3400W
Main Load Cut Off Voltage44VDC44VDC
Main Load Return Voltage52VDC52VDC
OFF-GRID OPERATION
AC Input
AC Start-up Voltage / Auto Restart Voltage120-140VAC/180VAC
Acceptable Input Voltage Range90-280VAC or 170-280VAC
Maximum AC Input Current40A50A
Nominal operating frequency50/60Hz
Surge power16400W20400W
PV Input (DC)
Maximum DC Voltage500VDC
MPPT Voltage Range90VDC~450VDC
Number of MPPT Trackers / Maximum Input Current1/27A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage220/230/240VAC
Output WaveformPure sine wave
Efficiency (DC to AC)94%
BATTERY & CHARGER
Nominal DC Voltage48VDC48VDC
Maximum Solar Charging Current160A160A
Maximum AC Charging Current140A140A

Additional Specifications:

  • Origin: Mainland China
  • Place of Origin: Guangdong, China
  • Input Voltage: 220/230VAC
  • Output Voltage: 220/230VAC
  • Output Frequency: 50HZ/60HZ
  • Output Type: Single
  • Size: 530/390/130 mm
  • Type: DC/AC Inverters
  • Inverter Efficiency: 98%
  • Weight: 16KG
  • Color: White
  • MPPT voltage range: 90-450VDC
  • Certificate: CE
  • OEM/ODM: Available, 20 years experience
  • Output wave form: Pure sine wave inverter
  • Operating Temperature: -10℃-50℃

8. Warranty and Support

8.1 Warranty Information

The Sumry MAX Series Hybrid Inverter comes with a 1-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.

Note: The warranty does not cover damage caused by improper installation, misuse, unauthorized modifications, or natural disasters.

8.2 Technical Support

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact our support team:

  • WhatsApp: +86 15802523190
  • WeChat: +86 15802523190
  • Email: 2293200068@qq.com

When contacting support, please have your inverter model number and a detailed description of the issue ready.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.