1. Introduction
This manual provides essential information for the safe and efficient operation of your Sumry MAX Series Hybrid Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference. The MAX Series Hybrid Inverter is designed to integrate solar power, utility power, and battery power to provide continuous power supply.

2. Key Features
- Pure sine wave solar inverter (on/off Grid capability)
- Output power factor 1.0
- Wi-Fi & GPRS available for iOS and Android monitoring
- Inverter can operate without a battery
- One-key restoration to factory settings
- Built-in Lithium battery automatic activation
- High PV input voltage range (90-500VDC)
- Built-in anti-dust kit for harsh environments
- Smart battery charge design to optimize battery life
- Dual output capability
- Dual PV input capability
- Touch button interface
- Built-in 160A MPPT solar charger (for 8.2kW and 10.2kW models)
- On/Off Grid Work Mode
- Dual communication ports for Battery communication and Wi-Fi communication
3. Installation and Connections
Proper installation is crucial for the safe and efficient operation of the inverter. It is recommended that installation be performed by a qualified electrician.
3.1 Rear Panel Connections Overview

The rear panel provides all necessary connection points for PV input, AC input/output, battery, and communication interfaces. Ensure all connections are secure and correctly polarized.
3.2 Mounting the Inverter
- Choose a suitable location that is well-ventilated, dry, and away from direct sunlight or heat sources.
- Ensure the mounting surface can support the weight of the inverter (approximately 16kg).
- Allow sufficient clearance around the inverter for proper airflow and cooling.
- Mount the inverter vertically using appropriate fasteners.
3.3 Wiring Instructions
- Battery Connection: Connect the battery bank to the BATTERY terminals, ensuring correct polarity (+ to + and - to -).
- PV Input Connection: Connect the solar panel arrays to the PV1 and PV2 input terminals. Observe correct polarity and ensure the PV voltage is within the specified MPPT range (90-450VDC) and maximum DC voltage (500VDC).
- AC Input Connection: Connect the utility grid power to the AC IN terminals.
- AC Output Connection: Connect your loads to the MAIN OUT and SECOND OUT terminals.
- Communication Connections: Connect Wi-Fi module, RS232, RS485, or BMS cables as required for monitoring and battery communication.
WARNING: All wiring must comply with local and national electrical codes. Disconnect all power sources before making any electrical connections.
4. Operation
The inverter features a user-friendly LCD display and touch buttons for monitoring and configuration.
4.1 LCD Display Overview

The LCD provides real-time status and operational data. Refer to the following key for understanding the display icons:
| No. | Icon | Description |
|---|---|---|
| 1 | PV | PV input |
| 2 | AC | AC input |
| 3 | INPUTBATTEMP | Input voltage, input frequency, PV voltage, battery voltage, charger current |
| 4 | 8.8 | Setting programs |
| 5 | 8.8 | Flashing with warning code, lighting with fault code |
| 6 | OUTPUTBATTLOAD | Output voltage, output frequency, load percent, load in VA, load in watt and discharging current |
| 7 | Load level | Load level (e.g., 25%, 50%, 75%, 100%) |
| 8 | DC/AC inverter circuit is working | DC/AC inverter circuit is working |
| 9 | CHARGING | Battery level |
| 10 | Utility charger circuit is working | Utility charger circuit is working |
| 11 | Unit connects to the PV panel | Unit connects to the PV panel |
| 12 | Unit connects to the mains | Unit connects to the mains |
| 13 | BYPASS | Load is supplied by utility power |
| 14 | Unit alarm is disabled | Unit alarm is disabled |
| 15 | OVER LOAD | Overload |
4.2 Basic Operation
- Power On/Off: Use the main power button (usually located on the front or side) to turn the inverter on or off.
- Mode Selection: The inverter supports various operating modes (e.g., Grid-tie with backup, Off-grid, Battery priority). These modes can typically be configured via the LCD panel or monitoring software.
- Monitoring: Use the Wi-Fi/GPRS module and associated app (iOS/Android) to monitor the inverter's performance, battery status, and energy flow remotely.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter.
- Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris. The built-in anti-dust kit helps in harsh environments, but regular checks are still recommended.
- Connection Checks: Annually inspect all electrical connections (PV, AC, Battery) for tightness and signs of corrosion.
- Battery Health: If using external batteries, monitor their health and charge cycles. The smart battery charge design helps optimize battery life.
- Software Updates: Keep the inverter's firmware updated as recommended by the manufacturer to ensure optimal performance and access to new features.
CAUTION: Disconnect all power sources before performing any maintenance or cleaning.
6. Troubleshooting
This section provides basic troubleshooting steps for common issues. For more complex problems, contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter not powering on | No AC input, battery disconnected, or low battery voltage. | Check AC input connection, ensure battery is connected and charged, verify main power switch is ON. |
| No power output to loads | Overload, fault condition, or output breaker tripped. | Reduce load, check LCD for fault codes (icon 5), reset output breaker. |
| PV input not detected | PV panels disconnected, low PV voltage, or fault in PV array. | Check PV connections and polarity, ensure sufficient sunlight, verify PV voltage is within operating range. |
| Overload warning (icon 15) | Connected loads exceed inverter's capacity. | Immediately reduce the connected load. |
| Communication issues (Wi-Fi/BMS) | Loose cable, incorrect settings, or network problem. | Check communication cable connections, verify Wi-Fi network, consult app instructions for settings. |
If the problem persists after attempting these solutions, please contact customer support.
7. Technical Specifications
Detailed specifications for the Sumry MAX Series Hybrid Inverter models.
| MODEL | MAX 8.2KW | MAX 10.2KW |
|---|---|---|
| Phase | 1-phase | |
| Maximum PV Input Power | 5400W+5400W | |
| Rated Output Power | 8200W/8200VA | 10200W/10200VA |
| Maximum Solar Charging Current | 160A | 160A |
| GRID-TIE OPERATION | ||
| PV Input (DC) | ||
| Nominal DC Voltage / Maximum DC Voltage | 360VDC/500VDC | |
| Start-up Voltage / Initial Feeding Voltage | 90VDC/120VDC | |
| MPPT Voltage Range | 90VDC~450VDC | |
| Number of MPPT Trackers / Maximum Input Current | 2/28A | |
| GRID OUTPUT (AC) | ||
| Nominal Output Voltage | 220/230/240VAC | |
| Output Voltage Range | 195~253VAC | |
| Nominal Output Current | 35.6A | 44.3A |
| Power Factor | >0.99 | |
| Feed-in Grid Frequency Range | 49~51±1Hz | |
| EFFICIENCY | ||
| Maximum Conversion Efficiency (DC/AC) | 98% | |
| TWO LOAD OUTPUT POWER | ||
| Full Load | 8200W | 10200W |
| Maximum Main Load | 8200W | 10200W |
| Maximum Second Load (battery mode) | 2733W | 3400W |
| Main Load Cut Off Voltage | 44VDC | 44VDC |
| Main Load Return Voltage | 52VDC | 52VDC |
| OFF-GRID OPERATION | ||
| AC Input | ||
| AC Start-up Voltage / Auto Restart Voltage | 120-140VAC/180VAC | |
| Acceptable Input Voltage Range | 90-280VAC or 170-280VAC | |
| Maximum AC Input Current | 40A | 50A |
| Nominal operating frequency | 50/60Hz | |
| Surge power | 16400W | 20400W |
| PV Input (DC) | ||
| Maximum DC Voltage | 500VDC | |
| MPPT Voltage Range | 90VDC~450VDC | |
| Number of MPPT Trackers / Maximum Input Current | 1/27A | |
| BATTERY MODE OUTPUT (AC) | ||
| Nominal Output Voltage | 220/230/240VAC | |
| Output Waveform | Pure sine wave | |
| Efficiency (DC to AC) | 94% | |
| BATTERY & CHARGER | ||
| Nominal DC Voltage | 48VDC | 48VDC |
| Maximum Solar Charging Current | 160A | 160A |
| Maximum AC Charging Current | 140A | 140A |
Additional Specifications:
- Origin: Mainland China
- Place of Origin: Guangdong, China
- Input Voltage: 220/230VAC
- Output Voltage: 220/230VAC
- Output Frequency: 50HZ/60HZ
- Output Type: Single
- Size: 530/390/130 mm
- Type: DC/AC Inverters
- Inverter Efficiency: 98%
- Weight: 16KG
- Color: White
- MPPT voltage range: 90-450VDC
- Certificate: CE
- OEM/ODM: Available, 20 years experience
- Output wave form: Pure sine wave inverter
- Operating Temperature: -10℃-50℃
8. Warranty and Support
8.1 Warranty Information
The Sumry MAX Series Hybrid Inverter comes with a 1-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.
Note: The warranty does not cover damage caused by improper installation, misuse, unauthorized modifications, or natural disasters.
8.2 Technical Support
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact our support team:
- WhatsApp: +86 15802523190
- WeChat: +86 15802523190
- Email: 2293200068@qq.com
When contacting support, please have your inverter model number and a detailed description of the issue ready.