Mudiro M-S1/M-H1

Contents

Mudiro 8KW Diesel Air Heater User Manual

Models: M-S1, M-H1

1. Introduction

This manual provides comprehensive instructions for the safe and efficient operation, installation, and maintenance of your Mudiro 8KW Diesel Air Heater (Models M-S1, M-H1). Please read this manual carefully before use to understand the product's functions and operational requirements.

1.1 Product Overview

Mudiro Diesel heaters are on-board heating devices independent of the automobile engine, featuring their own fuel lines, circuits, combustion heating devices, and control systems. Originally designed for preheating vehicle engines and cabs in cold environments to prevent cold start wear, these heaters now offer a wider range of applications. They can be used as space heating equipment in tents, indoor spaces, RVs, trucks, campers, boats, cabins, and garages, enhancing comfort for users during travel and daily life.

Mudiro Diesel Air Heater wide application diagram
Figure 1: Wide Application of Mudiro Diesel Air Heater in various environments like cars, trucks, buses, garages, cabins, boats, RVs, and tents.

2. Setup and Installation

2.1 Parts List Confirmation

Before beginning installation, please verify that all components listed below are present in your package.

Diagram showing all accessories included with the Mudiro Diesel Air Heater: Main Engine, LCD Switch, Remote Control, Manual, Exhaust Silencer, Intake and Exhaust Pipe, Air Outlet Pipe, LCD Switch Extension Cord, DC12V Two-Pin Power Cable, Air Filter, Vents, and Installation Parts.
Figure 2: Accessories Display. Includes Main Engine, LCD Switch, Remote Control, Manual, Exhaust Silencer, Intake and Exhaust Pipe, Air Outlet Pipe, LCD Switch Extension Cord, DC12V Two-Pin Power Cable, Air Filter, Vents, and Installation Parts.
  • 1 x Main Engine (Diesel Air Heater Unit)
  • 1 x LCD Switch
  • 1 x Remote Control
  • 1 x User Manual (this document)
  • 1 x Exhaust Silencer
  • 1 x Intake and Exhaust Pipe
  • 1 x Air Outlet Pipe
  • 1 x LCD Switch Extension Cord (1.5m)
  • 1 x DC12V Two-Pin Power Cable
  • 1 x Air Filter
  • 1 x Vents
  • 1 set Installation Parts (screws, clamps, etc.)
  • Optional: 1 x AC Power Adapter (for 100~240V AC input, if purchased with this option)

2.2 Installation Diagram and Power Supply

The installation of this compact heater is relatively straightforward, with many piping installation processes simplified. The primary steps involve installing the exhaust pipe and connecting the AC-DC power supply.

Installation diagram for the Mudiro Diesel Air Heater, showing connections for the exhaust pipe, intake pipe, air outlet pipe, and power supply. The exhaust pipe can be placed downwards or horizontally.
Figure 3: Installation Diagram. The exhaust pipe can be positioned downwards or horizontally.

For power, use a 12V or 24V DC power supply, or an AC to DC adapter (if included/purchased). The discharge current is recommended to be greater than 15A. During startup, the glow plug heats up, and the operating current may reach 12A for 3-5 minutes.

⚠ Critical Safety Warning:

The exhaust pipe operates at extremely high temperatures (up to 400°C / 752°F). During installation, use, maintenance, and disposal of this machine, ensure there are no flammable or explosive materials near the exhaust pipe. Exercise caution to prevent ignition of flammable materials that could cause fire.

This heater MUST be vented outdoors to prevent carbon monoxide poisoning. Always ensure the exhaust pipe is properly directed outside and kept away from children, pets, and dry grass/flammable ground cover.

3. Operating Instructions

3.1 Explanation of Principles (Heat Source, Heating, Control)

3.1.1 Heat Source:

Upon startup, the ignition plug heats for 1-3 minutes. The fan then activates, delivering air to the combustion chamber, while the diesel pump injects diesel. The atomized diesel mixes with air and ignites upon contact with the high-temperature ignition plug, generating significant heat. High-temperature exhaust gases are discharged through the exhaust gas outlet below.

3.1.2 Heating:

Heat from the combustion chamber is rapidly transferred to an aluminum heat exchanger and dissipated into the warm air duct via aluminum fins. An external fan blows air around the heat exchanger, and the heated air is expelled through the warm air outlet.

3.1.3 Control:

The device features an embedded controller. Users can control the heater via the connected switch panel, monitoring status, adjusting settings, and scheduling operations. Remote control is also possible using the provided remote or the Mudiro-developed mobile application.

Image showing three intelligent control methods for the Mudiro Diesel Air Heater: Smart APP Control, Remote Control, and LCD Panel Control.
Figure 4: Three Intelligent Control Methods: Smart APP Control, Remote Control, and LCD Panel Control.

3.2 Blue LCD Bluetooth Switch Instructions

Close-up of the Mudiro Diesel Air Heater's LCD control panel, displaying temperature, voltage, and various icons for settings. The image highlights features like automatic plateau identification, auto start-stop, temperature adjustment, and voice prompts.
Figure 5: Upgrade Bluetooth LCD Switch with features like automatic plateau identification, auto start-stop, temperature adjustment, and voice prompts.

3.2.1 Key Functions:

  • Power Button (⏻): Press and hold to turn the heater on/off.
  • OK Button:
    • Short press: Query working status.
    • Continuous short press: Open corresponding function.
    • Long press: Enter timing and parameter settings.
    • After entering timing/parameter settings, short press to confirm, long press to return to main interface.
  • Up Button (▲): Short press to increase working temperature or oil quantity. Press and hold to open remote control pairing function.
  • Down Button (▼): Short press to lower operating temperature or oil quantity. Press and hold to open manual oil pumping function.

3.2.2 Function Introduction:

  1. Machine Working Status Query Function:
    • Briefly press the OK key once.
    • Displays ambient temperature, shell temperature, set temperature/gear, power supply voltage, altitude, and timed startup/shutdown (if set).
  2. Temperature Control Mode Switching Function:
    • Press the OK key twice in a row.
    • In automatic temperature control mode, the switch displays "AT" and temperature in °C. In manual temperature control mode, it displays "MT" and the L-digit represents the gear.
  3. Voice Type Switching Function:
    • Press the OK key three times in a row.
    • Cycles through four language options for voice broadcast.
  4. Temperature Unit Switching Function:
    • Press the OK key four short times in a row.
    • Switches between Celsius (°C) and Fahrenheit (°F).
  5. Automatic Start-Stop Function:
    • Press the OK key five short times in a row.
    • Enable: Displays "AC-1". Disable: Displays "AC-0".
    • When enabled, if ambient temperature is 2°C or more below set temperature, the machine starts automatically. If ambient temperature is 1°C or more above set temperature, it shuts down automatically.
  6. Extreme Thermal Mode Function:
    • Press the OK key six short times in a row.
    • Turn on: Displays "HO-1". Turn off: Displays "HO-0".
    • When activated, the machine automatically increases fuel pump oil quantity and adjusts the air-oil ratio for rapid heating.
  7. Voice Prompt Function:
    • Press the OK key seven times in a row.
    • After opening, the operation switch provides voice prompts. After closing, there are no voice prompts.
  8. Remote Pairing Function:
    • Long press the "Up" key to enter pairing mode. The switch displays "HF-1" or "HF-2". Select the remote control signal using Up/Down keys. Short press the remote control power key to start. After successful pairing, the switch returns to the main interface.
  9. Manual Oil Pumping Function:
    • Long press the "Down" key to enter manual oil pumping interface. The switch displays "H OF". Short press "Up" to start pumping ("H ON" displayed). When fuel reaches the oil inlet, short press "Down" to stop ("H OF" displayed). Short press "OK" to return to main interface.
    • Note: If too much fuel enters the machine, black smoke may occur during startup.
  10. Timing Settings:
    • Long press the "OK" key to enter timing settings. The alarm clock icon appears.
    • "1 OF" indicates timing startup is set, "OF" means off. Use "Up" to start ("1 ON" displayed). Short press "OK" to confirm.
    • Timing is a countdown mode, max 99 hours 59 minutes. Use "Up"/"Down" to select value, short press "OK" to confirm.
    • After startup time, set shutdown time. "2 OF" indicates shutdown is set, "OF" means off. Use "Up" to start ("2 ON" displayed). Short press "OK" to confirm.
    • Press and hold "OK" to return to main interface after timing settings are complete.

3.3 Bluetooth App Guide

The Mudiro Diesel Air Heater supports control via a dedicated mobile application.

App Download & Bluetooth Connection Guide showing QR codes for iOS and Android apps, and screenshots of the app interface for pairing and control.
Figure 6: App Download & Bluetooth Connection Guide. Scan QR codes for iOS (AirHeater) or Android (Warm Drive) apps.
  • iOS System: Scan the QR code with your iPhone browser or search for "AirHeater" on the App Store.
  • Android System: Scan the QR code with your Android browser or search for "Warm Drive" on Google Play.
  • First-time Connection: Find the corresponding device in the app, click "Confirm Connection". A connection icon will appear on the switch. Press OK on the switch to confirm the connection.

4. Maintenance

Regular maintenance ensures the longevity and efficient operation of your diesel air heater.

  • Periodically check all pipes and connections for leaks or damage.
  • Ensure the air filter is clean and free from obstructions.
  • Inspect the exhaust pipe for any blockages or damage.
  • Keep the heater unit clean and free of dust and debris.
  • For detailed internal component inspection, refer to the "Internal Key Parts Terminology" section and consult a qualified technician if needed.

5. Troubleshooting

The Mudiro diesel heater features an intelligent self-diagnosis system that displays specific error codes (E-01 to E-13) for quick troubleshooting.

5.1 Internal Key Parts Terminology (Read before Repair)

Understanding the internal components can assist in diagnosing issues.

Diagram of the internal key parts of the Mudiro Diesel Air Heater, including Control box, Ignition plug, Safety plug, Air outlet, Heating zone, Combustion chamber, Air inlet, Air fan, and Flame retardant impeller.
Figure 7: Internal Key Parts Terminology. Important components include Control box, Ignition plug, Safety plug, Air outlet, Heating zone, Combustion chamber, Air inlet, Air fan, and Flame retardant impeller.

5.2 Error Codes and Solutions

Fault CodeMachine FailureTreatment Method
E-01Power supply undervoltageInsufficient supply voltage. Power supply voltage needs to be increased.
E-02Power supply overvoltageSupply voltage too high. The supply voltage needs to be reduced.
E-03Glow plugCheck whether the glow plug is open circuit or short circuit.
E-04Oil pump failureCheck the oil pump and harness. Check for wire breakage and short circuit.
E-05The machine is overheatingCheck the temperature sensor on the housing, or if the fan speed is abnormal.
E-06Motor failureCheck magnet polarity, hall sensor position, or loose motor terminal. Move.
E-07Disconnection faultCheck panel connection plug, blue. Loose or broken harness connection.
E-08The flame went outCheck for air or oil in the oil circuit. Blockage due to wax deposition resulting in poor oil supply.
E-09Faulty sensorCheck if the sensor plug is loose, moved, or broken wire, short circuit.
E-10Ignition failedCheck whether the oil circuit is blocked, or the oil inlet is not smooth, the oil pump is stuck, and the secondary ignition fails due to the blockage of the volatile screen caused by the problem. Is often burns.
E-11Altitude sensor failureAltitude sensor failure, please check.
E-12Faulty inlet air temperature sensorAir inlet temperature sensor failure, please check.
E-13Outlet air temperature sensor faultAir outlet temperature sensor failure, please check.

6. Specifications

AttributeValue
Brand NameMudiro
ModelM-S1/M-H1
Item TypeHeating & Fans
Switch TypeLCD Switch
FuelDiesel
Voltage12V / 24V DC / 100~240V AC (with adapter)
Power5-8KW
Shell ColourBlack & Red
Fuel Consumption0.12 L/h - 0.46 L/h
Fuel Tank Capacity5L
Remote Control Distance≤30m
Working Ambient Temperature-40℃ to 40℃
Item Weight9.5kg
Item Dimensions (L x W x H)38cm x 26cm x 25cm
OriginMainland China
CertificationCE, RoHS

7. User Tips

Based on user experiences, here are some helpful tips for optimal use:

  • Exhaust Pipe Management: The provided exhaust pipe might be short or require careful bending. Consider adding material under the heater's legs to raise it from the ground, ensuring the exhaust pipe doesn't touch dry grass or flammable surfaces, especially during summer.
  • Fuel Line Inspection: If the fuel lines are not the green silicone type, it is recommended to replace them for better performance and reliability.
  • Noise Levels: At higher heating settings, the device can become noticeably louder. Adjust settings to balance heat output with desired noise levels.
  • App Connection: If you encounter issues connecting to the app, ensure Bluetooth is enabled on your device and the heater, and try restarting both. Some users have found success without needing store assistance.
  • Power Supply for Startup: For a stable startup, ensure your power source can deliver over 15A, as the glow plug draws up to 12A for 3-5 minutes during ignition.
  • Initial Startup Error: If an error occurs during the very first startup, try restarting the device. Some users reported initial errors that resolved themselves after a restart.

8. Warranty and Support

8.1 Contact Information

For technical assistance, detailed instructions, or operational videos, please contact us. You can send an email to mudiromarketing@gmail.com or reach out to our customer service personnel via the sales platform where you purchased the product.

8.2 FCC Statement

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.