DATOUBOSS DT4860BF

DATOUBOSS 48V 6000W Hybrid Inverter User Manual

Model: DT4860BF (PV6000W)

Brand: DATOUBOSS

1. Introduction

This manual describes the assembly, installation, operation, warning code, and fault code of this unit. Please read this manual carefully before installations and operations. Keep this manual for future reference.

1.1. Purpose and Scope

This manual provides safety and installation guidelines as well as information on tools and wiring.

1.2. Key Features

  • Pure sine wave inverter
  • Built-in MPPT solar charge controller
  • Configurable input voltage range for home appliances and personal computers via LCD setting
  • Configurable battery charging current based on applications via LCD setting
  • Configurable AC/Solar Charger priority via LCD setting
  • Compatible to mains voltage or generator power
  • Auto restart while AC is recovering
  • Overload / Over temperature / short circuit protection
  • Inverter running without battery
  • Lithium battery activation function
  • Cold start function
  • Parallel connection quantity up to 12 units for 6KVA and 12KVA models (Battery must be connected)
  • Intelligent fan control greatly reduces fan noise

1.3. Basic System Architecture

The inverter/charger is designed to offer uninterruptible power support. A complete running system typically includes:

  • The DATOUBOSS Hybrid Inverter
  • PV modules (optional)
  • Generator or Utility power source

This inverter can power various appliances in home or office environments, including motor-type appliances such as tube lights, fans, refrigerators, and air conditioners.

Diagram showing the basic system architecture of the solar inverter connecting to PV, battery, grid, and various loads.
Basic System Architecture: PV, Battery, Grid, and Load connections.
Diagram illustrating a home power system with solar panels, battery, grid connection, and the inverter powering various household appliances.
Home Power System Diagram: Solar Inverter, Battery, and Grid Integration.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  • Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  • CAUTION: To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  • Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  • To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  • CAUTION: Only qualified personnel can install this device with battery.
  • NEVER charge a frozen battery.
  • For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
  • Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  • Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for the details.
  • Fuse is provided as over-current protection for the battery supply.
  • GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
  • NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
  • WARNING: Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
  • WARNING: This series of off-grid inverters provides a backfeed function without grid-tie protection. If enabled, implement protective measures prior to operation. The customer assumes full liability for any accidents resulting from the use of this function.

2.1. Warning Marks

MarkNameInstructionAbbreviation
DangerSerious physical injury or even death may occur if not following relevant requirements.Danger
WarningPhysical injury or damage to the device may occur if not following relevant requirements.Warning
Forbid (Electrostatic sensitive)Damage may occur if relevant requirements are not followed.Forbid
Hot temperatureDo not touch the base of the inverter as it will become hot.Hot
iNoteFor procedures taken for ensuring proper operation.Note

3. Setup and Installation

3.1. Unpacking and Inspection

Upon receiving the inverter, carefully unpack the unit and inspect it for any damage that may have occurred during transit. Report any damage to the carrier immediately.

3.2. Product Overview and Connections

Familiarize yourself with the inverter's components and connection ports before installation.

Front, left, and right side views of the inverter, with a detailed diagram of the top panel showing communication, battery, PV, AC input/output, and dry contact ports.
Product Overview: Front, Side Views, and Top Panel Connections.
Detailed view of the inverter's top panel, labeling the communication connection port, switch, dry contact port, battery connection port, PV input connection port, AC output/generator port, and AC input port.
Detailed Top Panel Connections.

Key Components and Ports:

  1. LCD display
  2. Charging indicator
  3. Fault or warning indicator
  4. Utility bypass/Inverter indicator
  5. ESC button
  6. UP button
  7. Down button
  8. Enter button
  9. Switch
  10. Parallel connection-CAN port
  11. PV input connection port
  12. AC output/Generator port
  13. AC input port
  14. Communication connection port
  15. Dry contact port
  16. Battery+ connection port
  17. Battery- connection port

3.3. BMS Communication Port Pin Definition

NO.BMS (4KVA)BMS (6KVA/12KVA)RS-232
1NCRS485-BRS232-TXD
2NCRS485-ARS232-RXD
3NCVSSVDD
4NCNCVSS
5NCNCNC
6VSSVSSNC
7RS485-ARS485-ANC
8RS485-BRS485-BVSS

3.4. Mounting the Unit

The inverter should be mounted in a location that complies with all safety guidelines, ensuring proper ventilation and protection from environmental factors. Refer to the full PDF manual for detailed mounting instructions.3.5. Wiring Connections

All wiring should be performed by qualified personnel, adhering to local electrical codes and regulations. Ensure all power sources are disconnected before making any connections.

  • Battery Connection: Connect the battery bank to the designated Battery+ and Battery- terminals. Ensure correct polarity.
  • AC Input/Output Connection: Connect the AC input from the utility grid or generator, and the AC output to your loads.
  • PV Connection: Connect the solar PV modules to the PV input connection port. Observe maximum voltage and current ratings.
  • Dry Contact Signal: Utilize the dry contact port for external control or monitoring signals as needed.
  • Grounding: The inverter must be connected to a permanent grounded wiring system.

4. Operation

4.1. Power On/Off

Follow the specific power-on and power-off sequences outlined in the full manual to ensure safe operation and prevent damage to the unit or connected equipment.

4.2. LCD Display and Control Panel

The inverter features a comprehensive LCD display and control buttons for monitoring and configuration.

Close-up view of the inverter's LCD display and control buttons: ESC, UP, DOWN, ENTER.
LCD Display and Control Buttons.
Diagram of the Smart LCD Display Screen, highlighting Fault Indicator, Battery Indicator, Utility/Inverter Indicator, and the ESC, UP, DOWN, ENTER buttons.
Smart LCD Display Screen: Indicators and Controls.

The LCD provides real-time information and allows users to configure various settings, including:

  • Battery charging current
  • AC/Solar charger priority
  • Acceptable input voltage range
  • Charging modes (AC power first, Solar priority, Solar power and AC power first, Solar only)
  • Discharge modes (SUB Solar First, USB Utility First, SBU Battery First)
Diagram showing four charging modes (AC power first, Solar priority, Solar power and AC power first, Solar only) and three discharge modes (SUB Solar First, USB Utility First, SBU Battery First) to maximize energy use.
Charging and Discharge Modes for Energy Optimization.

5. Specifications

The DATOUBOSS 48V 6000W Hybrid Inverter (Model DT4860BF) features robust specifications for reliable performance.

Summary of key specifications for the DATOUBOSS 6000W Hybrid Inverter, including Rated Output Power (6000W), Max. PV Input Power (8000W), DC Input (48V 125A), Max. PV Input Current (27A), AC Output (230VAC 50/60Hz 26.1A), Max. Solar Voltage (500V), Operating Temperature (-10 to 55°C), DC Max. Charging/Discharging Current (120A/125A), and Ingress Protection (IP54).
Key Specifications of the DATOUBOSS 6000W Hybrid Inverter.

5.1. Line Mode Specifications

ModelDT-4840BFDT-4860BFDT-48120BF
Rated Output Power4000VA/4000W6000VA/6000W12000VA/12000W
Nominal DC Input Voltage24V48V48V
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage230Vac
Low Line Voltage Disconnect90Vac±3V (for Home Appliances: APL) / 170Vac±3V (for Computers: UPS)
Low Loss Voltage Re-connect100Vac±3V (for Home Appliances: APL) / 180Vac±3V (for Computers: UPS)
High Line Voltage Disconnect280Vac±3V
High Line Voltage Re-connect270Vac±3V
Max AC Input Voltage280Vac±3V
Nominal Input Frequency50Hz/60Hz (Auto detection)
Low Line Frequency Disconnect40±1Hz
Low Line Frequency Re-connect42±1Hz
High Frequency Disconnect65±1Hz
High Frequency Re-connect63±1Hz
Output Voltage WaveformAs same as input waveform
Output Short Circuit ProtectionLine mode: Circuit Breaker; Battery mode: Electronic Circuits
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time (Single unit)10ms typical (UPS); 20ms typical (Appliances)
Transfer Time (Parallel)50ms typical
Pass Through Without BatteryYes
Max. Bypass Overload Current28A40A70A
Max. Bypass Input Current28A50A90A
Max. Inverter/Rectifier Current18.2A/4000W27.3A/6000W54.5A/12000W

5.2. Utility Charge Mode Specifications

ModelDT-4840BFDT-4860BFDT-48120BF
Nominal Input Voltage230Vac
Input Voltage Range90-280Vac
Nominal Output VoltageDependent on battery type
Max. Grid Charge Current100A120A210A
Charge Current Regulation10A-Max. Grid Charge Current (Adjustable unit is 1A)
Over Charge ProtectionYes
Grid charging Current (I.max/I.min)100A/25A120A/30A210A/50A

5.3. Solar Charging & Grid Charging Specifications

ParameterValue
Max. PV Open Circuit Voltage500V
PV voltage range85V-450V
Max. Input Power (DT-4840BF / DT-4860BF / DT-48120BF)6000W / 8000W / 16000W
Max. Solar Charging Current (DT-4840BF / DT-4860BF / DT-48120BF)120A / 120A / 210A
Max. Charging Current (PV+Grid) (DT-4840BF / DT-4860BF / DT-48120BF)120A / 120A / 210A
Max. PV Input Current (DT-4840BF / DT-4860BF / DT-48120BF)15A / 27A / 27A+27A
Min. Startup Voltage (DT-4840BF / DT-4860BF / DT-48120BF)80V / 75V / 75V

5.4. Charge Algorithm

The inverter uses a three-stage charging algorithm:

  • Boost CC (Constant current stage)
  • Boost CV (Constant voltage stage)
  • Float FV (Constant voltage stage)

The adjustable time for each stage depends on the battery bank size, with a minimum of 1 hour and a maximum of 12 hours.

5.5. Battery Type Setting

Battery TypeBoost CC/CVFloat
AGM28.2V/56.4V27V/54V
Flooded29.2V/58.4V27V/54V
Self-definedAdjustable, up to 30V/60V
Lithium

6. Maintenance

Regular maintenance is crucial for the longevity and optimal performance of your DATOUBOSS Hybrid Inverter. Always disconnect all power sources before performing any maintenance or cleaning.

  • Cleaning: Keep the inverter's exterior clean and free of dust. Use a dry cloth for cleaning. Do not use liquid cleaners.
  • Ventilation: Ensure that the ventilation openings are clear and unobstructed to prevent overheating.
  • Connection Checks: Periodically inspect all wiring connections for tightness and signs of corrosion.
  • Battery Health: Monitor battery health and ensure they are within their recommended operating parameters.

The inverter is designed with an IP54 dustproof rating, offering professional protection for stable output in harsh outdoor environments.

Image highlighting the IP54 dustproof model with features like overload protection, short circuit protection, overvoltage protection, and new IP54 dust protection.
New IP54 Dustproof Model: Professional Protection and Stable Output.

7. Troubleshooting

The inverter is equipped with various protection features, including overvoltage, overload, short circuit, and surge protection with EMI filtering.

Diagram illustrating surge protection with EMI filtering, showing the inverter connected to various household appliances and solar panels.
Surge Protection with EMI Filtering.

In case of a fault or warning, the LCD display will show relevant indicators. Refer to the full user manual for a detailed Warning Code Table and Fault Code Table to diagnose and resolve issues.

If errors persist after following the troubleshooting steps, please contact a qualified service center or your local dealer for assistance. Only qualified service personnel should attempt repairs.

8. User Tips

  • Battery-Free Operation: This inverter supports battery-free operation, allowing direct conversion of photovoltaic (PV) power to AC power for loads. This can reduce initial investment and battery usage.
  • Optimize PV Input: The inverter supports up to 8000W Max. PV Input Power and 27A Max. Solar Current, improving PV utilization efficiency.
  • Flexible Upgrades: The system allows for adding batteries later to expand energy storage capacity and improve off-grid self-sufficiency.
  • Multiple Scenarios: Suitable for various applications including RVs, outdoor camping, home use, yachts, agriculture, and emergency power.
Diagram explaining battery-free operation, where the inverter directly converts DC power from PV modules to AC power for loads without needing battery storage.
Battery-Free Operation Explained.
Illustrations of various usage scenarios for the DATOUBOSS 48V 6000W Solar Inverter, including RVs, outdoor camping, home use, yachts, agriculture, and emergency power.
Multiple Usage Scenarios.

9. Warranty and Support

For detailed warranty information and technical support, please refer to the complete user manual or contact DATOUBOSS Official Store. The full user manual (PDF) can be accessed here.

Related Documents - DT4860BF

Preview EASUN POWER IGrid SV II 6KW On-Grid Inverter with Energy Storage - Technical Specifications
Detailed technical specifications and selection guide for the EASUN POWER IGrid SV II 6KW On-Grid Inverter with Energy Storage. Features include pure sine wave output, hybrid operation modes, and parallel capabilities.
Preview DATOUBOSS DT2430 Solar Hybrid Inverter - Important Usage Instructions
Essential safety and usage guidelines for the DATOUBOSS DT2430 Solar Hybrid Inverter, including proper handling and operation based on detailed online introductions.
Preview DATOUBOSS DT4855U 5500W Off-Grid Hybrid Solar Inverter User Manual
Comprehensive user manual for the DATOUBOSS DT4855U 5500W Off-Grid Hybrid Solar Inverter. Includes safety instructions, fault code definitions, commissioning steps for parallel systems, and LCD configuration settings.
Preview DATOUBOSS TY-PSW-6000 Pure Sine Wave Inverter User Manual
This document provides detailed specifications, operational instructions, and troubleshooting guidance for the DATOUBOSS TY-PSW-6000 Pure Sine Wave Inverter. It covers product features, panel descriptions, technical specifications, and common problem solutions.
Preview DATOUBOSS 4.2KVA/7.0KVA Wechselrichter/Ladegerät Benutzerhandbuch
Umfassendes Benutzerhandbuch für den DATOUBOSS 4.2KVA/7.0KVA Wechselrichter/Ladegerät, das Installation, Betrieb, Spezifikationen und Fehlerbehebung für Hybrid-Stromsysteme beschreibt.
Preview EASUN POWER Hybrid 3.6KW/5.6KW Inverter/Charger User Manual
Comprehensive user manual for the EASUN POWER Hybrid 3.6KW and 5.6KW Inverter/Charger systems, detailing installation, operation, specifications, troubleshooting, and advanced features like parallel operation and Wi-Fi connectivity for efficient solar energy management.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.