SUMRY ECO-PRO Series

Contents

SUMRY ECO-PRO Series Hybrid Inverter User Manual

Models: ECO-PRO 3.6KW, ECO-PRO 4.2KW, ECO-PRO 6.2KW

1. Introduction

This manual provides essential information for the safe and efficient operation of your SUMRY ECO-PRO Series Hybrid Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference. This inverter is designed to integrate solar power, utility power, and battery power to provide a continuous and reliable power supply for your home or business.

For detailed diagrams and comprehensive instructions, please refer to the official user manual PDF: View User Manual (PDF).

2. Product Overview

The SUMRY ECO-PRO Series Hybrid Inverter is a versatile power solution for both on-grid and off-grid applications. It features a pure sine wave output, ensuring compatibility with sensitive electronics. Key features include:

  • Pure sine wave solar inverter (on/off Grid)
  • WIFI & GPRS connectivity for iOS and Android monitoring
  • Ability to run without a battery
  • One-key restoration to factory settings
  • Built-in lithium battery automatic activation
  • Integrated 120A MPPT solar charge controller (for 3.6KW/4.2KW/6.2KW models)
  • High PV input voltage range (90~450VDC)
  • Built-in anti-dust kit for harsh environments
  • Smart battery charge design to optimize battery life
  • Dual output capability
  • Removable LCD display and key for flexible installation
Front view of the SUMRY ECO-PRO Series Hybrid Inverter
Front view of the inverter.
Rear view of the SUMRY ECO-PRO Series Hybrid Inverter showing connection ports
Rear view showing AC In, Main Out, Second Out, Battery, and PV In ports.
Side view of the SUMRY ECO-PRO Series Hybrid Inverter
Side view of the inverter.

3. Technical Specifications

MODELECO-PRO 3.6KWECO-PRO 4.2KWECO-PRO 6.2KW
Phase1-phase
Maximum PV Input Power6200W6200W6500W
Rated Output Power3600W/3600VA4200W6200W/6200VA
Maximum Solar Charging Current120A120A120A
GRID-TIE OPERATION
PV Input (DC)
Nominal DC Voltage/Maximum DC Voltage360VDC/500VDC
Start-up Voltage/Initial Feeding Voltage60VDC/90VDC
MPPT Voltage Range60VDC~450VDC
Number Of MPPT Trackers/Maximum Input Current1/23A1/23A1/23A
GRID OUTPUT (AC)
Nominal Output Voltage200/230/240VAC
Output Voltage Range195.5~253VAC
Nominal Output Current15.7A18.2A27.0A
Power Factor>0.99
Feed-in Grid Frequency Range49~51±1Hz
EFFICIENCY
Maximum Conversion Efficiency (Solar/AC)98%
OFF-GRID OPERATION
AC INPUT
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage220/230/240VAC
Output WaveformPure sinewave
Efficiency (DC to AC)94%
BATTERY & CHARGER
Nominal DC Voltage24VDC24VDC48VDC
Maximum Solar Charging Current (Solar to AC)120A120A120A
Maximum AC Charging Current100A100A100A
PHYSICAL
Dimension (D x W x H)420*310*110 mm
Carton Dimension (D x W x H)500*415*180 mm
Net Weight (kgs)8.88.99.8
Gross Weight (kgs)1010.111
Operating Temperature-10℃ to 50℃
Output Frequency50HZ/60HZ
CertificationCE

4. LCD Display Interface

The inverter features an intuitive LCD display to monitor system status and configure settings. Below is a diagram explaining the various indicators and their functions:

Diagram of the inverter's LCD display with numbered labels pointing to different indicators and their descriptions.
LCD Display Indicators Overview
No.Icon/IndicatorDescription
1PVPV input
2ACAC input
3INPUTBATTEMPInput voltage, input frequency, PV voltage, battery voltage, charger current
48.8Setting programs
58.8 (flashing/solid)Flashing with warning code, lighting with fault code
6OUTPUTBATTLOADOutput voltage, output frequency, load percent, load in VA, load in watt and discharging current
7100% 25%Load level
8Inverter iconDC/AC inverter circuit is working
9CHARGINGBattery level
10Utility iconUtility charger circuit is working
11PV panel iconUnit connects to the PV panel
12Mains iconUnit connects to the mains
13BYPASSLoad is supplied by utility power
14Alarm disabled iconUnit alarm is disabled
15OVERLOADOverload

5. Setup and Installation

Important Safety Information: Installation should only be performed by qualified personnel. Ensure all power sources are disconnected before installation. Refer to the full PDF manual for detailed wiring diagrams and safety precautions.

5.1. Mounting the Inverter

  • Choose a suitable location: The inverter should be mounted indoors, in a well-ventilated area, away from direct sunlight, heat sources, and moisture.
  • Ensure adequate clearance around the unit for proper airflow.
  • Use appropriate mounting hardware to secure the inverter firmly to a vertical surface.

5.2. Wiring Connections

The rear panel of the inverter provides connection points for AC input, main AC output, secondary AC output, battery, and PV input. Follow these general guidelines:

  • Battery Connection: Connect the battery bank to the "BATTERY" terminals, ensuring correct polarity (positive to positive, negative to negative).
  • PV Input Connection: Connect the solar panel array to the "PV IN" terminals. Verify that the PV voltage is within the specified range (90-450VDC).
  • AC Input Connection: Connect the utility grid power to the "AC IN" terminals.
  • AC Output Connections: Connect your primary loads to the "MAIN OUT" terminals and secondary loads to the "SECOND OUT" terminals.
  • Ensure all connections are tight and secure to prevent loose contacts and potential hazards.
Rear view of the inverter showing AC In, Main Out, Second Out, Battery, and PV In ports for wiring.
Rear panel connections for wiring.

6. Operating Instructions

6.1. Initial Startup

  1. After all connections are made and verified, switch on the battery breaker.
  2. Switch on the PV array breaker (if applicable).
  3. Switch on the AC input breaker (if applicable).
  4. Turn on the inverter's power switch. The LCD display will light up, and the inverter will begin its startup sequence.
  5. Monitor the LCD display for any error codes or warnings.

6.2. LCD Display and Settings

Use the buttons below the LCD display to navigate through the menus and adjust settings. Refer to Section 4 for an explanation of the display indicators.

  • Monitoring: The display shows real-time data such as input/output voltage, frequency, battery status, load level, and charging current.
  • Setting Programs: Access setting programs (indicated by '8.8' on the display) to configure parameters like output voltage, charging priority, and battery type.
  • Warning/Fault Codes: If a warning or fault occurs, the display will flash with a corresponding code. Consult the troubleshooting section or the full PDF manual for details.

6.3. WIFI & GPRS Monitoring

The inverter supports remote monitoring via WIFI and GPRS. Download the dedicated app for iOS or Android devices and follow the in-app instructions to connect your inverter for real-time data and remote control capabilities.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter. Always disconnect all power sources before performing any maintenance.

  • Cleaning: Periodically clean the inverter's exterior with a dry cloth. Ensure ventilation openings are free from dust and debris. The built-in anti-dust kit helps, but regular checks are still recommended.
  • Connections: Annually check all wiring connections for tightness and signs of corrosion.
  • Battery Health: Monitor battery voltage and temperature regularly. Ensure the battery charging parameters are correctly set for your battery type to optimize battery life.
  • Environment: Ensure the installation environment remains within the specified operating temperature range (-10℃ to 50℃) and free from excessive humidity.

8. Troubleshooting

If you encounter issues with your inverter, refer to the following common troubleshooting steps. For complex problems or persistent errors, consult the full PDF manual or contact technical support.

Common Issues and Solutions:

  • Inverter not turning on:
    • Check battery connections and voltage.
    • Ensure the inverter's power switch is ON.
    • Verify AC input power is present.
  • No AC output:
    • Check AC output wiring and circuit breakers.
    • Verify the inverter is not in fault mode (check LCD display).
    • Ensure the load is not exceeding the inverter's rated output power.
  • PV input not detected:
    • Check PV array connections and voltage.
    • Ensure PV input voltage is within the MPPT range (90-450VDC).
  • Overload warning:
    • Reduce the connected load.
    • Check for short circuits in the load wiring.

If the LCD display shows a flashing warning code or a solid fault code, refer to the detailed error code explanations in the comprehensive user manual (PDF).

9. User Tips

  • Regularly check the inverter's display for operational status and any alerts.
  • Optimize battery settings for your specific battery type to maximize lifespan and performance.
  • Keep the inverter's ventilation clear to prevent overheating, especially in warmer climates.
  • Utilize the WIFI/GPRS monitoring feature for convenient remote management and performance tracking.

10. Warranty and Support

The SUMRY ECO-PRO Series Hybrid Inverter comes with a 1-year warranty. For warranty claims or technical support, please contact your point of purchase or the manufacturer directly. Ensure you have your product model number and purchase details available.

For further assistance, you may refer to the contact methods mentioned in the introduction or the official user manual PDF.

© 2024 SUMRY. All rights reserved.

Documents and downloads