1. Introduction
1.1 Purpose and Scope
This manual describes the assembly, installation, operation, and troubleshooting of the DATOUBOSS 6200W Hybrid Inverter. Please read this manual carefully before installation and operation, and keep it for future reference. It provides safety and installation guidelines, as well as information on tools and wiring.
1.2 Key Features
- Type: DC/AC Inverter
- Capacity: 6200VA/6200W
- Protection Degree: IP54 (Dustproof Model)
- Max. PV Input Power: 8500W
- Max. PV Input Voltage: 500VDC
- MPPT Tracking Range: 60-500VDC
- Full Load MPPT Range: 360-430VDC
- Max Charging Current: 120A
- Max Input Current: 36A
- Maximum Main Load: 6200W
- Waveform: Pure sine wave
- Maximum Conversion Efficiency: 98%
- Lightning and High-Voltage Protection
- Input and Output Safety
- Increased PV Input Current for more power
- EMI Filtering Reduces Interference
- Higher PV Utilization When PV and Mains are Complementary
- Auto restart while AC is recovering
- Overload/Over temperature/short circuit protection
- Smart battery charger design for optimized battery performance
- Cold start function
1.3 Basic System Architecture
The DATOUBOSS Hybrid Inverter combines functions of an inverter, solar charger, and battery charger to provide uninterruptible power support. It can be integrated with a generator or utility power source and PV modules to form a complete energy system. This inverter is capable of powering various home and environmental appliances, including motor-type appliances like tube lights, fans, refrigerators, and air conditioners.

2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for the details.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
- NEVER cause AC output and DC input short circuits. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
3. Installation
3.1 Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the unit and a user manual inside the package.
3.2 Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level in order to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and approximately 50 cm above and below the unit.
- The ambient temperature should be between -10°C and 50°C to ensure optimal operation.
- The recommended installation position is to adhere to the wall vertically.
- Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing three screws:
- 1, 2: Use M6*80mm expansion bolts.
- 3: Use M4 or M5.


3.3 Battery Connection
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed. Please refer to typical amperage in the table below as required fuse or breaker size.
WARNING! All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable and terminal size as below.
Recommended Battery Cable and Terminal Size:
| Rated Capacity | Typical Amperage | Battery Capacity | Wire Size | Cable (mm²) | Ring Terminal D (mm) | Ring Terminal L (mm) | Torque Value |
|---|---|---|---|---|---|---|---|
| 3KVA | 132A | 100AH | 1*4AWG | 22 | 6.4 | 33.2 | 2~3 Nm |
| 3.6KVA | 165A | 200AH | 2*8AWG | 9 | 6.4 | 29.2 | 5 Nm |
| 4KVA | 165A | 200AH | 2*4AWG | 25 | 8.4 | 33.2 | 5 Nm |
| 5.5KVA | 121A | 200AH | 1*2AWG | 34 | 6.4 | 39.2 | 2~3 Nm |
| 6.2KVA | 124A | 200AH | 1*2AWG | 38 | 8.4 | 39.2 | 5 Nm |
| 11KVA | 228A | 250AH | 1*3/0AWG | 85 | 8.4 | 54 | 5 Nm |
Follow these steps to implement battery connection:
- Assemble battery ring terminal based on recommended battery cable and terminal size.
- Insert the battery wires flatly into battery connectors of inverter and make sure the bolts are tightened with a torque of 2 Nm in clockwise direction. Make sure polarity at both the battery and the inverter/charger is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.
WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.
CAUTION!! Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).
3.4 AC Input/Output Connection
CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure the Inverter can be disconnected during maintenance and fully protected from over current of AC input. The recommended spec of breaker is 32A for 24V system and 63A for 48V system.
CAUTION!! There are two terminal blocks with "IN" and "OUT" markings. Please do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.
Suggested Cable Requirement for AC Wires:
| Rated Capacity | Gauge | Torque Value |
|---|---|---|
| 3KVA | 12AWG | 1.2~1.6Nm |
| 3.6KVA | 12AWG | 1.2~1.6Nm |
| 4KVA | 12AWG | 1.2~1.6Nm |
| 5.5KVA | 10AWG | 1.4~1.6Nm |
| 6.2KVA | 10AWG | 1.4~1.6Nm |
| 11KVA | 8AWG | 1.4~1.6Nm |
Please follow below steps to implement AC input/output connection:
- Before making AC input/output connection, be sure to open DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. And shorten phase L and neutral conductor N3 mm.
- Insert AC input wires according to polarities indicated on the terminal block and tighten the terminal screws. Be sure to connect the PE protective conductor (Ground) first.
- Ground (yellow-green)
- L (brown or black)
- N (blue)
WARNING: Be sure that the AC power source is disconnected before attempting to hardwire it to the unit.
- Make sure the wires are securely connected.
CAUTION: Appliances such as air conditioners are required at least 2~3 minutes to restart because it's required to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check the manufacturer of the air conditioner if it's equipped with a time-delay function before installation. Otherwise, this inverter/charger will trigger an overload fault and cut off output to protect your appliance, but sometimes it still causes internal damage to the air conditioner.
3.5 PV Connection (Only apply for the model with solar charger)
CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between the inverter and PV modules.
WARNING! All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.
Typical PV Cable Requirement:
| Typical Amperage | Gauge | Torque Value |
|---|---|---|
| 30A | 12AWG | 1.4~1.6Nm |
PV Module Selection:
When choosing the right PV module, be sure to first consider the following requirements:
The open circuit voltage (Voc) of the PV modules does not exceed the maximum PV array open circuit voltage of the inverter. The maximum supply voltage of the PV modules should be close to the optimal PV access voltage range of the inverter for best performance. If one PV module cannot meet this requirement, it is necessary to connect multiple PV modules in series.
3.6 Final Assembly
After connecting all wirings, please put the bottom cover back by screwing the two screws.
4. Operation
4.1 Power ON/OFF
Once the unit has been properly installed and the batteries are connected, simply press the On/Off switch (located on the button of the case) to turn on the unit.
Steps to Start Up:
Connect the battery that meets the requirements (battery voltage needs to be beyond 23V) or AC (AC needs to confirm the suitable input range depending on the output mode), then you can start up the inverter.
- Mains Power On: Connect to normal AC power, press the switch. The system will automatically turn on. If you set AC output power priority, after waiting for a period of time, the panel will display AC mode, indicating successful machine turn-on, and then enter AC mode.
- Battery Boot: Connect to battery, press the power-on button to establish a working power source. The system will automatically turn on. After waiting for a period of time, the panel will display battery mode, indicating successful machine turn-on, and then enter battery mode.
Shutdown Steps:
When the system is in battery mode or AC mode output, press the switch again, then the system will be turned off.
4.2 LCD Display Icon
The operation and display panel is located on the front panel of the inverter. It includes RGB indicators and an LCD display.

Home Screen:
The LCD is a touch screen. The upper part of the LCD screen displays overall information of the inverter.
- The absence of an icon in the center of the home screen indicates that the system is operating normally. If a gray icon and characters are displayed in the center of the main screen, it means that the inverter has an alarm, and the alarm information will be displayed in characters under this icon (detailed error information can be viewed in the instruction manual alarm menu). If a red icon and characters are displayed in the center of the main screen, it means that the inverter is faulty, and the fault information will be displayed in characters under this icon (detailed error information can be viewed in the instruction manual alarm menu).
- At the top of the screen is the time.
- System Settings icon: Press the Settings button to enter the system settings screen, including battery settings, system working mode, grid settings, basic settings, advanced features, device information.
- The main screen displays information including PV, mains, load, and battery. It also shows the direction of energy flow with arrows. Equivalent power. When approaching the limit value, the color on the panel will change from green to red, making the system information vividly displayed on the main screen.
- Photovoltaic power and load power are always positive.
- The mains power is connected negatively to the grid and obtained positively.
LED Indicator Functions:
| Code | Machine State | Color | Effect | Display |
|---|---|---|---|---|
| 1 | Stand by/Self-test | Colorful | Gradient color display | Breath light |
| 2 | Under DC mode | Blue | Monochrome display (one light keeps flashing) | NO |
| 3 | Under AC/Full charge under AC mode | Green | Monochrome display | NO |
| 4 | Charging under AC mode | Green | Monochrome display | YES |
| 5 | Solar charging | Yellow | Monochrome display | YES |
| 6 | Full charge under solar power | Yellow | Monochrome display | NO |
| 7 | Under the alarm | Red | Monochrome display | YES (recoverable) |
| 8 | Solar energy and AC charging at the same time | Half and half (yellow on top, green on bottom) | Monochrome display | YES |
4.3 Touch Screen Operation Instructions
The touch screen allows for detailed monitoring and configuration of the inverter's parameters. The main menu provides access to various sub-pages:
- Inverter Page: Displays machine type, inverter type, driver version, LCD version, temperatures (boosting, machine, MPPT, inverter, MOS), IAP status.
- PV Page: Shows PV input voltage, current, power for PV1 and PV2, and records daily, monthly, yearly, and total PV power generation.
- Battery Page: Displays battery type, BMS communication function status, battery voltage, charge current, discharge current, bus voltage, and Li Battery Active status.
- BMS Page: Details BMS 485 protocol, SOC, charge/discharge current, BMS temperature, discharge/charge limit voltage, and charge limit current.
- Load Page: Shows dual status, output, load percent, active power, and apparent power.
- Mains Page: Displays AC input frequency, input voltage, and AC input power.
- External CT Detail Page: Shows frequency, input voltage, and AC input power at the CT detection point.
- System Settings Menu: Accesses various settings categories:
- System Work Mode: Configures ECO function, output priority (SUB, SBU), output type (SIG, PAL, 3P1, 3P2, 3P3), clear generation, and reset factory settings.
- Grid Setting: Configures input voltage range (APL/UPS), grid-connected regulation mode, grid feed enable/current, external CT function, zero export to CT, AC CHA open/stop time.
- Charge Setting: Configures charge source priority (CSO, SNU, OSO), max utility charge current, max charge current, solar supply priority.
- Basic Setting: Configures output voltage/frequency, alarm control, overload bypass/restart, MIP cut off buzzer, over temp restart, auto back menu.
- Battery Setting: Configures battery type (AGM/FLD/USE/LIA/PYL/TQF/GRO/LIB/LIC), bulk charging voltage, float charging voltage, battery cut-off voltage, battery low voltage, BMS function switch, BMS SOC settings, battery equalization settings.
- Advanced Function: Configures dual mode, dual output, output open/stop time, DC to AC voltage, AC to DC voltage.
- Device Info: Displays system time, backlight settings, and RGB switch.
5. Maintenance
Regular maintenance is crucial for the longevity and optimal performance of your DATOUBOSS Hybrid Inverter. Always ensure the unit is disconnected from all power sources (AC, DC, PV) before performing any maintenance tasks.
- Cleaning: Periodically clean the exterior of the inverter to prevent dust buildup, especially around ventilation openings. Use a dry, soft cloth. Do not use liquid cleaners.
- Ventilation: Ensure that the inverter's ventilation openings are clear and unobstructed to allow for proper heat dissipation. Maintain the recommended clearances around the unit as specified in the installation section.
- Wiring Inspection: Periodically check all wiring connections (battery, AC input/output, PV) for tightness and signs of wear or damage. Loose connections can lead to overheating and system malfunctions.
- Battery Health: Monitor battery voltage and performance through the LCD display. Ensure batteries are not frozen and are charged according to recommended parameters.
- Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure your inverter is running with the latest features and bug fixes.
6. Troubleshooting
6.1 Fault and Alarm Description
The inverter provides various fault and alarm codes to help diagnose issues. Alarms typically cause the red LED to flash and display a code on the LCD, but the inverter does not enter fault mode. Faults indicate a more serious issue, causing the red LED to stay on and the inverter to enter fault mode.
Warning Codes:
| Warning Code | Warning Event | Audible Alarm |
|---|---|---|
| 01 | Fan locked when inverter starts | Beeps three times every 1 second |
| 02 | Over temperature | None |
| 03 | Battery overcharge | Beeps once every 1 second |
| 04 | Low battery | Beeps once every 1 second |
| 07 | Overload | Beeps once every 0.5 seconds |
| 10 | Output power derating | Beeps twice every 3 seconds |
| 15 | Low PV energy | Beeps twice every 3 seconds |
| 16 | High AC input during bus soft start (>280VAC) | None |
| 60 | Power feedback protection | None |
| 61 | Communication interruption (Battery) | Beeps immediately if communication fails after successful connection. |
| 69 | Battery status does not allow charging | None |
| 70 | Battery status requires charging | None |
| 71 | Battery status does not allow discharging | None |
Fault Codes:
| Fault Code | Fault Event | Explanation/Possible Cause | Action |
|---|---|---|---|
| 01 | Fan locked when inverter shuts down | Fan malfunction | Replace fan. |
| 02 | Over temperature or poor NTC connection | Internal temperature too high | Check for blocked airflow or high ambient temperature. |
| 03 | Battery overvoltage | Battery voltage too high | Check battery specifications and quantity. |
| 04 | Battery undervoltage | Battery voltage too low | Charge battery or replace battery. |
| 05 | Output short circuit or internal overheating detected | Output short circuit or internal converter component temperature exceeds 120°C | Check wiring, remove abnormal loads. |
| 06 | Output overvoltage | Output voltage too high | Return to service center. |
| 07 | Overload timeout | Inverter overloaded (105%), or derated output power exceeded by load. | Reduce connected load. |
| 08 | Bus overvoltage | Bus voltage too high | Return to service center. |
| 09 | Bus soft start failure | Bus soft start failed | Return to service center. |
| 51 | Overcurrent or surge | Overcurrent detected | Restart device. If error persists, return to service center. |
| 52 | Bus undervoltage | Bus voltage too low | Return to service center. |
| 53 | Inverter soft start failure | Inverter soft start failed | Return to service center. |
| 55 | DC voltage in AC output | DC component detected in AC output | Return to service center. |
| 57 | Current sensor fault | Current sensor malfunction | Return to service center. |
| 58 | Output undervoltage | Output voltage too low | Return to service center. |
| 59 | PV voltage out of limit | PV input voltage exceeds specifications | Reduce the number of series PV modules. |
7. Technical Specifications
The following table provides detailed technical specifications for the DATOUBOSS 6200W Hybrid Inverter (Model DT4862BF).
| Feature | Specification | |
|---|---|---|
| Input | Input Type | L+N+PE |
| Rated Input Voltage | 220/230/240VAC | |
| Voltage Range | 90-280VAC±3V (APL Mode), 170-280VAC±3V (UPS Mode) | |
| Frequency Range | 50Hz/60Hz (Auto-adaptive) | |
| Rated Power (Battery Inverter) | 6200W | |
| Output | Rated Power (PV Inverter) | 8500W |
| Output Voltage | 220/230/240VAC±5% | |
| Output Frequency | 50/60Hz±0.1% | |
| Waveform | Pure Sine Wave | |
| Peak Power | 12400VA | |
| Grid-tied Operation | Feed-in Grid Voltage Range | 170-265VAC |
| Feed-in Grid Frequency Range | 49-51Hz/59-61Hz | |
| Efficiency | Nominal Output Current | 26.9A |
| Power Factor Range | >0.99 | |
| Maximum Conversion Efficiency (DC/AC) | 98% | |
| Battery | Rated Voltage | 48Vdc |
| Constant Voltage Charging (Adjustable) | 56.4Vdc | |
| Float Charging Voltage (Adjustable) | 54Vdc | |
| Charger | PV Charging Method | MPPT |
| Max. PV Input Power | 8500W | |
| MPPT Input Voltage Range | 60-500Vdc | |
| Max. PV Input Voltage | 500Vdc | |
| Max. PV Input Current | 27A | |
| Max. Charging Current | 120A | |
| General | Weight | 23.2KG |
| Operating Temperature | -10°C to 50°C | |
| Protection Degree | IP54 | |
8. Warranty and Support
For warranty information, technical support, or service inquiries, please contact DATOUBOSS Official Store directly. Ensure you retain your purchase records for any warranty claims.
A detailed user manual in PDF format is available for download. Please refer to the official product page or contact customer support for the PDF link: User Manual (PDF)