1. Introduction
Thank you for choosing the TIMEMORE Basic 3 Black Mirror Coffee Weighing Platform. This manual provides essential information for the proper setup, operation, and maintenance of your new coffee scale. The Basic 3 is designed for precision coffee brewing, featuring flow rate display, auto-timer, ratio function, and three brewing modes (Regular, Pour-over, Espresso).

2. Product Overview
The Basic 3 features a sleek design with capacitive touch keys and a physical main switch for complete power-off. It comes with a silicone pad for heat protection.

Component Identification:
- Weighing platform: The main surface for placing items to be weighed.
- Silicone pad: Protects the weighing platform from heat and internal components.
- Power switch + Mode toggle button: After powering on, slide the switch (towards the M) to cycle through modes: Regular / Pourover / Espresso.
- TYPE-C charging port: With silicone cover for protection.
- Tare button: Short press to tare weight; Long press to enter sleep mode.
- Ratio button: Short press to record or reset coffee weight; Long press to turn the ratio function on/off.
- Timer button: Short press to start/pause timing; Long press to reset timer; Long press for 4 seconds to turn sound on/off.
- TYPE-C charging cable: Included for charging.

Display Indicators:
- Time: Maximum elapsed time is 59 minutes and 59 seconds (59:59).
- Flow Rate: Current pour rate, displayed in grams per second.
- Weight: Shows weights up to 2kg.
- Ratio: Can be turned on or off in both Regular and Pourover modes.
- Battery indicator: Displays the approximate charge remaining.
- Sound indicator: Indicates that audio feedback is enabled.
- Pourover mode indicator
- Espresso mode indicator
- OZ indicator: Indicates that the selected unit of measurement is ounces. By default, Basic 3 uses grams for weight measurements. Quick press the Tare button 6 times to toggle between units.
PS: These instructions are also available on a transparent, peel-off sticker pre-installed on your Basic 3. Once you have mastered your workflow, feel free to remove this sticker.
3. Setup
For accurate and stable readings, proper setup is crucial. Avoid common mistakes that can lead to unstable measurements.
Initial Setup:
- Placement: Always use the Basic 3 on a hard, flat, and stable surface. Ensure all four feet of the scale rest completely on the same solid surface. No foot should hang over the edge or remain unsupported. Check that the scale does not tilt or rock.
- Silicone Pad: Use the included silicone pad on top of the weighing platform to protect it from heat and its internal components. It is not a cushion for underneath the scale.
- Charging: The scale is not fully charged at the factory. Fully charge it before first use.
Avoiding Unstable Readings:
Incorrect Setup to Avoid:
- Fabric Mats: Do not place the scale on a woven mat, coffee mat, cup coaster, towel, carpet, rubbery fabric, or any other soft or flexible material. These can compress, shift, or cause the scale to rock slightly, leading to inaccurate readings.
- Airflow Interference: Moving air from fans, air conditioners, vents, or open windows can press on the filter paper and brewer, causing the scale reading to drift. If the filter paper sways or trembles, airflow is present. Turn off or redirect nearby fans/AC, move away from vents, and close windows.
- Vibrations: Touching the table, footsteps, closing a door, or operating nearby appliances (grinder, refrigerator, pump) can transmit vibrations. Test on a stable counter without touching it and move the scale away from operating equipment.
- Static Electricity/Electronics: Keep wireless chargers and transmitting devices away during use. Avoid rubbing dry plastic, synthetic cloth, or clothing near the scale, as these can build static charge.

4. Operating Modes
The Basic 3 offers three distinct brewing modes: Regular, Pour-over, and Espresso. You can switch between these modes using the physical toggle switch on the side.

Switching Modes:
After powering on, slide the physical switch (towards the 'M' for Pour-over or 'O' for Espresso) to cycle through modes. The switch automatically rebounds to the middle position to complete one mode switch. Modes cycle in the order of Regular, Pour-over, Espresso.
4.1. Regular Mode
In Regular Mode, the scale functions as a standard weighing and timing device. It includes Ratio, Flow Rate, Timing, and Weighing functions.

4.2. Pour-over Mode
Designed for pour-over coffee, this mode features automatic timing and weighing when weight changes, along with a ratio function.

- Enter Pour-over Mode: Slide the side switch towards 'M'. The Pour-over icon will appear.
- Prepare for Brewing: Place your brew gear and coffee. Short-press the Timer button to start a 3-second countdown.
- Start Pouring: After the countdown, the timer will show [--:--] and the weight will reset to [0.0]. Once you begin pouring, the scale will start the timer.
- During Brewing: The ratio display will update in real time based on the amount of water added.
- Pause/Reset: If you place the brewing equipment back on the scale after a short break, short-press the Timer button once to resume timing and weighing. Press it again to pause. Long-press the Timer button to reset the display and start a new pour-over session.
Note: To account for the bloom, the timer will only stop automatically if the brew lasts more than 40 seconds.

4.3. Espresso Mode
This mode is exclusively designed for real espresso extraction scenarios, featuring automatic flow-rate detection, auto-zero, and timing functions. The Ratio function is disabled in Espresso mode.

- Enter Espresso Mode: Slide the side switch towards 'O'. The Espresso icon will appear, and the timer area will display: ESP.
- Automatic Tare: After 1 second, the scale is ready to use. Place your cup on the platform. Once detected, the scale will automatically tare.
- Automatic Timing & Weighing: When the scale detects a normal espresso flow rate, the timer will start automatically, and weight will track liquid in real time.
- Extraction Complete: When the brew is complete, remove the cup to stop the timer. The final values will blink on the display. Place the cup or wait 10 seconds for the scale to automatically reset.
Important Note on Espresso Mode:
Espresso Mode uses automatic flow-rate detection. If you pour water by hand (e.g., from a kettle), the flow rate will be far greater than a real espresso extraction. The scale will not recognize this as an extraction, remain in the "waiting" state, automatically tare any registered weight to zero, and the timer will not start. This is normal behavior, not a defect.
To confirm Espresso Mode is working: The timer starts counting automatically when active. If the timer stays at 00:00, it's still waiting for a valid extraction flow.

5. Charging and Battery
The Basic 3 is equipped with a large-capacity lithium battery for long-lasting performance.

Battery Specifications:
- Battery Type: Built-in 1600mAh high-capacity rechargeable lithium battery
- Rated Voltage: 3.7 V
- Operating Voltage Range: 3.4 V - 4.25 V
- Approximate Full Charge Time: 3.5 hours
- Battery Life: Approximately 24 hours of continuous use, or 280 uses based on a 5-minute pour-over session.
Charging Method:
- Input: 5 V DC/1 A power input via USB Type-C charging cable.
- Charging Adapter: The scale includes a USB-C charging cable but does not include a charger. Use your own 5V/1A charger.
- Important: Do not use a fast charger. Fast charging will not make the scale charge faster; it only creates extra heat and may damage the battery.
- Battery Maintenance: Recharge the scale periodically even when it is not used for a long time. This helps keep the battery active and supports long-term battery health.
- Low Battery: Avoid fully depleting the battery. If the battery is fully depleted, it may require a low-current charge via a computer USB port before a standard adapter can be used.
6. Maintenance and Care
Proper care will ensure the longevity and accuracy of your TIMEMORE Basic 3 scale.
General Care:
- Cleaning: The scale surface is made of acrylic. Wipe with a soft, damp cloth. Do not use abrasive cleaners or immerse the scale in water.
- Silicone Pad: Always use the included silicone heat-resistant pad on top of the scale before setting down hot items like glass servers. Prolonged direct contact with high temperatures can accelerate aging of the weighing-surface material and may damage the scale's internal precision components.
- Water Resistance: The scale has a water-resistant housing design, certified with an IPX3 waterproof rating (splash-proof surface only). Avoid allowing liquid to enter the charging port or any gaps in the scale body to minimize the risk of water damage. Avoid prolonged exposure to high heat and humidity.
- Disassembly: Basic 3 is calibrated to exact specifications. Unauthorized disassembly may compromise its reliability and usability.

7. Troubleshooting
If you encounter issues with your scale, refer to the following common problems and solutions.
Common Issues and Solutions:
| Symptom | Possible Cause / Solution |
|---|---|
| Scale reading is unstable or drifting |
|
| Display stuck on "8888" after power on | "8888" is the startup self-test display. Do not touch any buttons or the scale surface during startup. An unstable surface can also cause this. Restart the scale on a hard, flat, stable surface, keeping hands away until the normal display appears. |
| Espresso Mode timer does not start / weight keeps resetting to zero | This is normal behavior if a valid espresso flow is not detected. Espresso Mode is flow-sensitive and designed for real espresso extraction. Pouring water by hand (e.g., pour-over style) will not activate the timer as the flow rate is too high. The scale will remain in "waiting" state and auto-tare. The timer will only start automatically with a slow, steady espresso flow. |
| Scale not turning on or low battery indicator | The scale may not be fully charged. Fully charge the scale using a 5V/1A USB Type-C charger. If the battery was fully depleted, it might require a low-current charge via a computer USB port first. |
For the complete guide to all scale modes, please refer to the user manual included with your product (PDF).
8. Specifications

| Feature | Specification |
|---|---|
| Product Name | BLACK MIRROR Basic 3 Coffee Weighing Platform |
| Measure Range | 0.2 g - 2000 g (0.01 oz - 70.55 oz) |
| Precision | 0.1g |
| Weight (approx.) | 300g |
| Size (L x W x H) | 140mm x 120mm x 20mm |
| Storage Temperature | -10°C - 55°C |
| Operating Temperature | On product surface: -10°C - 60°C With included silicone pad: -20°C - 100°C |
| Button Control | Capacitive touch buttons |
| Audio Feedback | Built-in buzzer |
| Power Supply | Built-in 1600mAh high-capacity rechargeable lithium battery |
| Charging Method | 5 V DC/1 A power input via USB Type-C charging cable Built-in intelligent charging management system Charging adapter not included Adapter requirement: 220 V AC/110 V AC to 5 V DC For faster charging, a 5 V DC/2 A adapter is recommended |
Comparison with Basic 2:

The Basic 3 offers enhanced functionality with Espresso Mode and Coffee-to-Water Ratio function, improved precision (0.2g minimum weighing), stronger anti-interference capabilities, and better battery life compared to Basic 2.
9. User Tips
- Initial Charge: Always fully charge the scale before its first use to ensure optimal battery performance.
- Pour-over Timer: Utilize the auto-start timer in Pour-over mode for consistent brewing, as it begins automatically when water is poured.
- Ratio Function: Experiment with the ratio calculator in Pour-over mode to find your preferred coffee-to-water ratio.
- Espresso Mode Testing: If testing Espresso Mode without a machine, pour water in the thinnest, slowest stream possible to mimic an espresso shot and observe the timer for activation.
- Silicone Pad Use: Always use the included silicone pad when placing hot items on the scale to protect the surface and internal components.
- Display Visibility: Note that the digital display on the white scale may be less clear than the black version due to material differences. If display visibility is a priority, the black model is recommended.
10. Warranty and Support
The Basic 3 comes with a limited one-year manufacturer's warranty. This warranty does not cover damage caused by wear and tear or attempts to disassemble the device. Failure to follow the instructions in this manual may void your product warranty.
For further assistance or support, please contact your retailer or the manufacturer directly.
PDF User Manual: A detailed user manual in PDF format is available for download. You can find it by searching for "TIMEMORE Basic 3 User Manual PDF" online or contacting customer support.