1. Introduction
This multi-function inverter/charger combines the functions of an inverter, a PWM solar charger, and a battery charger to provide uninterruptible power support. Its comprehensive LCD display offers user-configurable and easy-accessible button operations for settings such as battery charging current, AC/Solar charger priority, and acceptable input voltage based on different applications.
Important Note: The battery capacity of the correct matching system is determined according to the specific usage requirements of the load and application scenarios. Incorrect sizing can lead to insufficient battery capacity or excessive waste of power generation. Please refer to the manual recommendation or consult a qualified professional.
2. Product Features
- Pure sine wave inverter output.
- Built-in PWM solar charge controller.
- Configurable input voltage range for home appliances and personal computers via LCD setting.
- Configurable battery charging current based on applications via LCD setting.
- Configurable AC/Solar charger priority via LCD setting.
- Compatible with mains voltage or generator power.
- Automatic restart while AC power is recovering.
- Overload, over temperature, and short circuit protection.
- Smart charging system optimizes battery performance.
- Cold start function.
3. Product Overview
The PowMr Hybrid Solar Inverter is designed for efficient power management in off-grid or hybrid solar systems. Below are visual representations of the unit and its components.




4. Setup
4.1 Physical Installation
Mount the inverter in a dry, well-ventilated area, away from direct sunlight and heat sources. Ensure sufficient clearance around the unit for proper airflow. The inverter is designed for wall mounting.
4.2 Wiring Connections
Refer to the connection diagrams below for proper wiring. All wiring should be performed by a qualified electrician to ensure safety and compliance with local electrical codes.

- Power On/Off Switch: Main power control for the inverter.
- AC Input: Connect to utility grid or generator AC power.
- AC Output: Connect to household appliances/loads.
- PV Input: Connect to solar PV panels. Max PV Array Open Circuit Voltage is 80V.
- DC Input: Connect to battery bank.
- Input Breaker: Overcurrent protection for AC input.
- COM Port: Communication port (e.g., RS232).
- NC/NO Contacts: Dry contacts for external control or monitoring.

4.3 Battery Connection
The inverter operates on a 24VDC battery system. Ensure your battery bank is correctly configured for 24V. Only use sealed lead-acid batteries or sealed GEL/AGM lead-acid batteries.

5. Operating Instructions
5.1 LCD Display and Buttons
The inverter features a comprehensive LCD display and function buttons (ESC, UP, DOWN, ENTER) for monitoring and configuration. The display shows real-time system status, including input/output voltage, battery charge level, and operational mode. Indicators for charging, fault, and general status are also present.

5.2 User-Configurable Settings
Through the LCD interface and function buttons, users can configure various parameters:
- Input Voltage Range: Adjust for home appliances or personal computers.
- Battery Charging Current: Set the charging current based on battery type and capacity.
- AC/Solar Charger Priority: Define whether AC or solar power takes precedence for charging.
Consult the detailed user manual (physical copy or digital version) for step-by-step instructions on navigating the menu and adjusting these settings.
6. Specifications
Below are the technical specifications for the PowMr PS-3K Hybrid Solar Inverter:

| Category | Parameter | PS-3K-110V | PS-3K-220V |
|---|---|---|---|
| General | Rated Power | 3000VA/2400W | |
| Input Voltage Waveform | Sinusoidal (utility or generator) | ||
| Input | Voltage | 120VAC | 230VAC |
| Frequency Range | 50Hz/60Hz (Auto Sensing) | ||
| Output | AC Voltage Regulation | 120VAC | 230VAC |
| Surge Power | 6000VA | ||
| Waveform | Pure Sine Wave | ||
| Battery & AC Charger | Battery Voltage | 24VDC | |
| Float Voltage | 27VDC | ||
| Overcharge Protection | 30VDC | ||
| AC Charging Current | 20A/30A | ||
| Solar Controller | Charging Current (PWM) | 50A | |
| Max PV Array Open Circuit Voltage | 80V | ||
| Max PV Power Input | 1200W | ||
| Standby Power Consumption | 2W | ||
| Physical | Dimensions (L*W*H) | 42cm*8cm*33cm | |
| Weight | 8KG | ||
| Certification | CE | ||
7. Maintenance
To ensure optimal performance and longevity of your PowMr Hybrid Solar Inverter, follow these maintenance guidelines:
- Regular Cleaning: Keep the inverter's exterior clean and free from dust and debris. Use a dry cloth; do not use liquids.
- Ventilation: Ensure that the ventilation openings are not blocked to prevent overheating.
- Cable Connections: Periodically check all cable connections for tightness and signs of corrosion. Loose connections can lead to power loss or overheating.
- Battery Health: Monitor your battery bank's health according to the battery manufacturer's recommendations. Ensure proper charging and discharge cycles.
- Environmental Conditions: Operate the inverter within its specified temperature and humidity ranges.
8. Troubleshooting
If you encounter issues with your inverter, refer to the fault indicator on the LCD display (Figure 2) for error codes or messages. Common issues and general troubleshooting steps include:
- No Power Output: Check the input breaker (Figure 5, item 6), battery connections, and ensure the inverter is switched on. Verify AC input from utility or generator.
- Battery Not Charging: Check solar panel connections (PV Input, Figure 5, item 4) and AC input (Figure 5, item 2). Ensure solar panels are receiving adequate sunlight. Verify battery charging current settings.
- Overload Warning: Reduce the load connected to the inverter. The inverter has overload protection (see Product Features).
- Over Temperature Warning: Ensure proper ventilation around the inverter. Clear any obstructions from air vents.
- Short Circuit: Immediately disconnect all loads and check for any short circuits in the wiring or connected appliances.
For persistent issues, consult the full user manual or contact customer support.
9. User Tips
- Software Updates: While the new package may not include a CD disc, software for monitoring or configuration might be available. Contact customer service if you require the software.
- System Sizing: Always ensure your battery bank and solar array are appropriately sized for your energy consumption to maximize efficiency and system lifespan.
- Safety First: Always disconnect power sources before performing any maintenance or wiring adjustments.
10. Support