POWLAND SMG II 6.2K-WIFI-PL

Contents

POWLAND 6.2KW 48V Hybrid Solar Inverter User Manual

Model: SMG II 6.2K-WIFI-PL | Brand: POWLAND

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your POWLAND 6.2KW 48V Hybrid Solar Inverter. Please read this manual thoroughly before installation and operation to ensure optimal performance and safety.

POWLAND 6.2KW 48V Hybrid Solar Inverter main product image

Main product image of the POWLAND 6.2KW 48V Hybrid Solar Inverter.

2. Product Features

  • Lithium battery activation function by PV or Utility
  • Compatible work with LiFePO4 battery via RS485
  • Pure sine wave output
  • Power factor 1.0
  • PV input Voltage 60Vdc-500Vdc
  • Built-in MPPT 60A/100A/120A
  • Capable to work without battery
  • Detachable dust cover for harsh environment
  • WiFi remote monitoring optional
  • Support multiple output priority: UTL (Utility), SOL (Solar), SBU (Solar-Battery-Utility), SUB (Solar-Utility-Battery)
  • EQ function to optimize battery performance and extend lifecycle

3. Product Overview

3.1. Front Panel and Indicators

POWLAND Hybrid Solar Inverter front panel with LCD and function keys

Front panel of the POWLAND Hybrid Solar Inverter, highlighting the LCD display and function keys. The table below details the LED indicators and function key descriptions.

LED IndicatorMessages
AC / INV (Green Solid On)Output is powered by utility in Line mode.
AC / INV (Green Flashing)Output is powered by battery or PV in battery mode.
CHG (Green Solid On)Battery is fully charged.
CHG (Green Flashing)Battery is charging.
FAULT (Red Solid On)Fault occurs in the inverter.
FAULT (Red Flashing)Warning condition occurs in the inverter.
Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode
Detailed LCD Display and Indicators

Detailed view of the LCD display and its indicators. The table below explains each numbered indicator.

No.Description
1PV input
2AC input
3Input voltage, input frequency, PV voltage, battery voltage, charger current
4Setting programs
5Flashing with warning code, Lighting with fault code
6Output voltage, output frequency, load percent, load in VA, load in watt and discharging current
7Load level
8DC/AC inverter circuit is working
9Battery level
10Utility charger circuit is working
11Unit connects to the PV panel
12Unit connects to the mains
13Load is supplied by utility power
14Unit alarm is disabled
15Overload

3.2. Rear Panel Connections

POWLAND Hybrid Solar Inverter rear panel with connection ports

Rear panel of the inverter, showing the various connection ports. The numbered labels indicate their functions.

  1. Wire outlet hole (RS232/RS485 communication port)
  2. Power on/off switch
  3. Grounding
  4. AC input
  5. AC output
  6. PV input
  7. Battery input

4. Setup and Installation

4.1. Mounting the Unit

Inverter mounting diagram with clearances

This diagram illustrates the recommended mounting clearances for the inverter to ensure proper ventilation and operation.

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level in order to allow the LCD display to be read at all times.
  • The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  • The recommended installation position is to be adhered to the wall vertically.
  • Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.

CAUTION: SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

4.2. PV Panel Wiring Method

Solar photovoltaic panel wiring diagram for series and parallel connections

This diagram shows the wiring methods for solar photovoltaic panels in series and parallel configurations.

  • In series: Increase the voltage of the system in series. This voltage needs to be less than the hybrid inverter PV maximum input voltage Voc/inverter. The entire photovoltaic system should use the same type of photovoltaic panel.
  • In parallel: Parallel increases the current of the system. This current should not exceed the maximum PV input current of the hybrid inverter.
  • PV cable dimensions: 6-8A/mm².

4.3. Battery Connection

Battery connection diagram for 48V system

This diagram illustrates how to connect multiple 12V batteries to form a 48V system for the 6.2KW model.

Connect all battery packs as shown in the chart. The 6.2KW model supports a 48VDC system.

5. Operating Modes

Off Grid Inverter System Diagram showing power flow

This diagram illustrates the operation of the off-grid inverter, showing how it can supply power to loads during power failure and how it mixes solar, battery, and utility power.

This inverter must work with a battery. Please ensure that it is connected to the battery before you connect solar panels.

  • Operation with battery connected: Solar Power and AC Power available.
  • Operation with battery connected (no AC power): Solar Power and AC Power not available.

6. WI-FI Monitoring

WiFi monitoring module and SmartESS app QR codes

This image shows the WiFi monitoring module and QR codes for downloading the SmartESS app for iOS and Android devices, enabling remote monitoring of the inverter.

WiFi & GPRS are available for iOS and Android. Download the SmartESS app using the provided QR codes for remote monitoring.

7. Specifications

A detailed user manual in PDF format is available for download at: POWLAND 6.2KW Hybrid Solar Inverter User Manual (PDF)

MODELISolar-SMG-II-6.2KW-Wifi-PL
Capacity6.2KVA/6.2KW
Parallel CapabilityNO
Lithium Battery activationYES (By PV or Utility)
Lithium Battery communicationYES (RS485)
INPUT
Nominal Voltage230VAC
Acceptable Voltage Range170-280VAC (For personal Computer); 90-280VAC (For Home Appliances)
Frequency50/60 Hz (Auto sensing)
OUTPUT
Nominal Voltage220/230VAC ±5%
Surge Power12400VA
Frequency50/60Hz
WaveformPure Sine wave
Transfer Time10ms (For personal Computer); 20ms (For Home Appliances)
Peak Efficiency (PV to INV)96%
Peak Efficiency (Battery to INV)93%
Overload Protection5s@ >= 140% load; 10s@110%~140% load
Crest Factor3:1
Admissible Power Factor0.6~1 (inductive or capacitive)
BATTERY
Battery Voltage48VDC
Floating Charge Voltage54VDC
OverCharge Protection63VDC
Charging MethodCC/CV
SOLAR CHARGER & AC CHARGER
Solar Charger TypeMPPT
Max.PV Array Power6500W
Max.PV Array Open Circuit Voltage500VDC
PV Array MPPT Voltage Range60VDC~500VDC
Max. Solar Input Current27A
Max. Solar Charge Current120A
Max.AC Charge Current80A
Max. Charge Current (PV+AC)120A
PHYSICAL
Dimensions, D x W x H (mm)438*295*105
Package Dimensions, D x W x H (mm)560*375*185
Net Weight (Kg)9
Communication InterfaceRS232+RS485
ENVIRONMENT
Operating Temperature Range(-10°C to 50°C)
Storage Temperature(-15°C~50°C)
Humidity5% to 95% Relative Humidity (Non-condensing)

Product specifications are subject to change without further notice.

8. Safety and Protection

Inverter protection features icons

The inverter is equipped with multiple protection features to ensure safe and reliable operation.

  • Overload Protection
  • Overheating Protection
  • Battery Protection
  • High/Low Voltage Protection
  • Short Circuit Protection
  • Overcurrent Protection
  • Anti-Reverse Protection
  • Power Failure Protection

9. Maintenance

Regular maintenance ensures the longevity and efficient operation of your inverter. Please follow these guidelines:

  • Dust Removal: Regularly inspect the inverter for dust accumulation, especially on the detachable dust cover and ventilation grilles. Clean as needed to ensure proper airflow and prevent overheating.
  • Connection Check: Periodically check all electrical connections (PV, AC, Battery) to ensure they are secure and free from corrosion.
  • Environmental Check: Ensure the operating environment remains within the specified temperature and humidity ranges.

10. Troubleshooting

This section provides basic troubleshooting steps for common issues. For more complex problems, refer to the full user manual or contact technical support.

10.1. Fan Noise

Problem: The inverter fan is making continuous noise.

Possible Cause & Solution: The fan typically operates under load to dissipate heat. If it's constantly noisy without heavy load, it might indicate a high internal temperature or a fault. Check the ambient temperature and ensure proper ventilation around the unit. Ensure the detachable dust cover is clean and not obstructing airflow. If the noise persists or occurs without significant load, consult the full user manual or contact support.

11. User Tips

  • Fan Operation: The inverter's fan is designed to run when necessary to cool the internal components, especially under load. It's normal for the fan to be audible during operation.
  • Battery Compatibility: The inverter is compatible with LiFePO4 batteries via RS485 communication, which can help optimize battery performance and extend its lifespan.

12. Warranty and Support

For detailed warranty information, technical assistance, or service requests, please refer to the official product documentation provided with your inverter or contact POWLAND customer service directly. Ensure you have your product model number and purchase details ready when contacting support.

13. Product Video

This video provides an unboxing and overview of the POWLAND 6.2KW Hybrid Solar Inverter, showcasing its components and design.

Play video
Watch video online
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.