1. Introduction
This manual provides essential information for the safe and efficient operation of your Junsun Wallbox Type 2 EV Charger. Please read it thoroughly before installation and use to ensure proper functionality and safety.
2. Safety Precautions
2.1. Installation Safety
- Installation is restricted to properly trained, qualified, and authorized electrical professionals.
- First commissioning and maintenance must comply with existing standards and installation regulations.
- Always cut off power supply before connecting external power supply to charger input. Do not connect the line with electricity.
- No extension cables must be used when connecting an electric vehicle to an electric vehicle power supply.
- Repair or replacement of the charger shall not be carried out without authorization, and only by the manufacturer. Do not modify the charger without authorization.
- Do not remove safety signs, warning labels, nameplates, or signage.
2.2. Electrical Hazards/Fire Hazards
- When using the charger, please read the relevant tips and instructions of the vehicle carefully.
- It is necessary to regularly check whether there is damage on the socket or charging cable (including the charging cable) of the charger and check if the housing is broken.
- If the charger is damaged, it must be turned off and replaced immediately.
- Only connect electric vehicles or their charging equipment; do not connect other loads (e.g., power tools).
- When pulling the charging gun, please hold the plug, not the cable.
- Do not bend, squeeze, or tilt the charging gun to avoid mechanical damage. Avoid contact with heat, dirt, or water.
- Ensure adequate external ventilation system if charging in indoor areas where toxic or explosive gases may be produced.
- Avoid dropping the charger or strong mechanical impact, otherwise it may destroy the electrical safety of the equipment causing potential safety hazards.
- It is strictly forbidden to use in an environment with combustible materials or explosive gases, otherwise there is a risk of explosion.
- Do not let conductive objects such as metal foreign objects fall into the inside of the charger, otherwise accidents may occur.
- The PE (Protective Earth) end of the charger must be reliably connected.
3. Package Contents
The package typically contains the following items:
- The charger x1
- Empty Gun Holder x1
- Card x2
- Screw x9
- Expansion Screws x4
- Specification x1
- Certificate Of Conformity x1
- Packing List x1

Image: Overview of the Junsun EV charger package contents.
4. Installation
4.1. Mounting the Charger
The charger is designed for hanging installation. Follow these steps:
- Fix the back panel to the wall using small screws.
- Fix the entire machine to the back panel on the wall using small screws.

Image: Step-by-step diagram for wall mounting the EV charger.
4.2. Wiring Steps
Connect the input wire connectors L, N, and PE of the plug to the corresponding hollow open L, N, and PE ends of the distribution box.

Image: Wiring diagram illustrating how to connect the charger to the electrical distribution box.
5. Operation
5.1. Charging Steps
- Ensure the charging station is correctly connected to the power supply.
- Insert the charging gun into the vehicle's gun slot.
- Start charging using card swiping or APP code scanning.
- The normal charging of the vehicle is completed.
- Click on the app or swipe to end charging.
- Unplug the charging gun and return it to its original position.

Image: Visual guide for the EV charger usage steps.
5.2. Indicator Description and Status
The charger features an indicator light and a display screen to show its current status. Below is a summary of the indicator behavior for different operating states:
- Idle State: Indicator light is always green. The display shows 0.000 kWh, 0.00 kW, 226.8 V, 0.00 A, and 00:00:00. Road light is green constantly on.
- Connected State: Indicator light flashes green. The display shows 0.000 kWh, 0.00 kW, 226.8 V, 0.00 A, and 00:00:00. Road light is green constantly on.
- Delay State: Indicator light is always blue. The display shows 56.703 kWh, 7.05 kW, 226.8 V, 31.1 A, and 08:06:12. Road lights transition from blue to yellow, always on.
- Charging State: Indicator light flashes blue. The display shows 56.703 kWh, 7.05 kW, 226.8 V, 31.1 A, and 08:06:12. Charging light flashes green. Road lights show a blue flow.
- Charging Finish State: Indicator light is always blue. The display shows 56.703 kWh, 7.05 kW, 226.8 V, 31.1 A, and 08:06:12. Charging light is green always on. Road light is blue constantly on.
- Fault State: Indicator light flashes red. The display shows E01 (example fault code), 0.000 kWh, 0.00 kW, 226.8 V, 0.00 A, and 08:06:12. Road light is red constantly on.

Image: Detailed view of the charger's display and indicator light behavior for different operating states.
Indicator Light State Table
| Operating State | Red | Green | Blue | Code |
|---|---|---|---|---|
| Idle (no Wi-Fi connect) | / | Flash | / | / |
| Idle | / | Always on | / | / |
| Insert charging gun | / | Flash | / | / |
| Charging | / | / | Flash | / |
| Charging finish | / | / | Always on | / |
| Over-voltage protection | Flash 1 time | / | / | E01 |
| Under-voltage protection | Flash 2 time | / | / | E02 |
| Over current protection | Flash 3 time | / | / | E03 |
| PCB main board over-temp protection | Flash 4 time | / | / | E04 |
| Ground protection | Flash 5 time | / | / | E05 |
| CP voltage protection | Flash 6 time | / | / | E06 |
| Relay fault | Flash 7 time | / | / | E07 |
| Leakage protection | Flash 8 time | / | / | E08 |
| E-stop button | Flash 15 time | / | / | E15 |
| Card reader fault | Flash 16 time | / | / | E16 |
| Ammeter fault | Flash 17 time | / | / | E17 |
| Swipe stop | / | / | / | S1 |
| APP stop | / | / | / | S2 |
| Fully charged stop | / | / | / | S3 |
| Car stop | / | / | / | S4 |
| Under-balance stop (operational version) | / | / | / | S5 |
| Charge interruption (operational version) | / | / | / | S6 |
6. Specifications
The Junsun Wallbox EV Charger is available in various configurations. Key specifications include:
| Feature | Specification |
|---|---|
| Touchscreen | Yes |
| Operating Temperature | -30℃~+50℃ |
| Wireless Support | No |
| Cable Length | 4m/5m (optional) |
| IP Rating (Charger) | IP65 |
| Voltage | 195V~220V |
| Current | 6-8-10-13-16-20-24-32A (Optional) |
| Material | TPU |
| Charger Type | Type 2 |
| Power (W) | 1.3~7KW (Optional) |
| Weight | 2.8~4kg |
| Leakage protection | AC30mA/AC30mA+DC 6mA (Optional) |
| Plug | Schuko/CEE (Optional) |
| CEE power plug IP Rating | IP44 |
| Control box Protection Degree | IP65 |
| Plug Protection Degree | IP55 |
| Frequency | 50/60HZ |
| Rated Power | 3.5kw&7kw (Optional) |
| Phase | 1 Phase |
| Charging Type | Type2 IEC 62752 |
Physical Dimensions
Control box dimensions: 18.6cm (width) x 35.4cm (height) x 11.1cm (depth).
Cable length from control box to gun head: 3.5m / 4.5m / 7.5m / 9.5m (Custom made options available).

Image: Dimensions of the charger and cable length options.

Image: Compatibility chart for various electric vehicle models.
7. Maintenance
Regularly inspect the charging cable and plug for any signs of wear, damage, or corrosion. Ensure the control box and charging gun are clean and free from dirt, dust, and moisture. Do not attempt to open or repair the unit yourself; contact qualified service personnel for any issues.
The charger is designed to withstand various environmental conditions:
- Rainy environment: IP65 rated for protection against water jets.
- Heavy snow environment: Withstands temperatures down to -30°C.
- Sunscreen prevention: Withstands temperatures up to +50°C.

Image: Environmental resistance features of the charger.
8. Troubleshooting
If you encounter any issues with your Junsun EV Charger, refer to the table below for possible causes and suggested solutions.
| Fault Name | Possible Cause | Exclusion Suggestions |
|---|---|---|
| AC overvoltage | AC input voltage too high |
|
| AC undervoltage | AC input voltage too low | Check background monitoring data. If long-term undervoltage (175Vac), adjust input undervoltage protection point down to 90 Vac via configuration software. |
| AC overcurrent | Excessive AC input current |
|
| Over Temp | The temp inside the AC pile is too high | Check installation environment for other heating devices. Ensure ambient temperature is below 50°C. |
| Excessive leakage current | Excessive ground leakage current |
|
| Ground Fault | Poor grounding of input/output or reverse connection of input L/N |
|
| Abnormal communication (internet mode) | Poor communication in the background of the communication pile |
|
| Abnormal connection of charging gun | Abnormal connection of charging gun CC/CP |
|
9. User Tips
Based on common user inquiries and experiences, consider the following tips:
- Power Reduction: If you purchase an 11KW or 22KW charger but your car does not support 3-Phase power, the device will automatically reduce the power to support a maximum of 3.5KW or 7KW to protect your vehicle.
- Last Current Value: The charger remembers the last charging current value used.
- Scheduling: While direct timer setting is not available, you can schedule charging for up to 5 hours.
- Grounding: The charger supports grounding.
- Compatibility: This product is suitable for all Type 2 interface EV models. For Tesla vehicles, an IEC 62752 adapter may be needed.
- Plug Diameter: A 3.5KW charger can use a standard household socket. For 7KW (blue connector), the diameter is 55mm. For 11KW (red connector), it's 55mm. For 22KW (red connector), it's 63mm.
- Leakage Protection: 3.5KW and 7KW models have AC 30mA protection. 11KW and 22KW models have AC 30mA + 6mA DC leakage protection.
10. Warranty and Support
The product comes with a 2-year quality guarantee and replacement/repair within 365 days. For detailed warranty information or technical support, please refer to the official product documentation or contact Junsun customer service. A PDF user manual is available for download for more comprehensive information.
For a comprehensive guide, please refer to the User Manual (PDF).

Image: Product certifications for quality assurance.