1. Introduction

The SUNSHINE P4 PRO is an advanced intelligent regulated DC power supply designed for precision applications, particularly in phone repairing and electronics. It features a 30V/6A high-frequency output, four-level memory for storing settings, dual-port charging capabilities, high-refresh current curve visualization, and upper computer sharing for enhanced control and analysis.

SUNSHINE P4 PRO Intelligent Regulated Power Supply front view
Figure 1: SUNSHINE P4 PRO Intelligent Regulated Power Supply. This image shows the main unit with its display and control buttons, highlighting its intelligent features and specifications like 30V/6A output, four-level memory, and protection mechanisms.

2. Safety Precautions

  • Always ensure the power supply is connected to a properly grounded outlet.
  • Do not operate the device in wet or damp conditions.
  • Avoid short-circuiting the output terminals.
  • Ensure proper ventilation to prevent overheating.
  • Do not attempt to open or repair the unit yourself. Refer to qualified service personnel.
  • Verify voltage and current settings before connecting to a device to prevent damage.
  • The unit includes built-in overcurrent, overvoltage, and short circuit protection.
Intelligent Overvoltage and Overcurrent Protection
Figure 2: Intelligent Overvoltage and Overcurrent Protection. This image illustrates the multi-layer protection mechanisms built into the device, including overcurrent, overvoltage, and short circuit protection, ensuring safer operation.

3. Product Components and Interface

The SUNSHINE P4 PRO features an intuitive interface with a color display and various control buttons and ports.

Front Panel Diagram of SUNSHINE P4 PRO
Figure 3: Front Panel Diagram. This diagram labels the key components and interfaces of the power supply, including the display screen, control buttons, output ports, and charging ports.
  • Display Screen: Shows real-time voltage, current, power, energy, and status.
  • M1, M2, M3, M4 Buttons: Memory buttons for storing and recalling four adjustable data sets.
  • V/C Button: Voltage/Current switch, also functions as a curve time base switch.
  • LOCK Button: Locks the current settings to prevent accidental changes.
  • OCP Button: Overcurrent Protection activation/deactivation.
  • OVP Button: Overvoltage Protection activation/deactivation.
  • ON/OFF Button (Output): Toggles the power output to the terminals.
  • Rotary Encoder: Used for voltage and current adjustment.
  • Main Power Switch: Rocker switch on the side for turning the unit ON/OFF.
  • Type-C Charging Port: Supports various fast-charging protocols (PD3.0/PPS/QC2.0/QC3.0/IP 5V.2.4A/AFC/FCP/SCP/HSCP).
  • USB-A Charging Port: Supports various fast-charging protocols (QC2.0/QC3.0/IP 5V.2.4A/AFC/FCP/SCP/HSCP).
  • Positive Output Plug Interface (Red): For positive output connection.
  • Negative Output Plug Interface (Black): For negative output connection.
  • Ground Plug Interface (Green): For ground connection.
Dual-port Charging USB-C and USB-A
Figure 4: Dual-port Charging. This image highlights the integrated USB-C and USB-A charging ports, compatible with multiple device protocols for real-time detection of fast-charging voltage and current.

4. Setup Instructions

  1. Unpacking: Carefully remove the power supply and all accessories from the packaging. Verify that all components are present (power supply unit, power cable, test leads, user manual).
  2. Placement: Place the unit on a stable, level surface with adequate ventilation around it. Ensure no vents are blocked.
  3. Power Connection: Connect the provided power cable to the power input on the rear of the unit and then to a grounded AC power outlet.
  4. Initial Power On: Flip the main power switch (located on the side) to the 'ON' position. The display screen should light up.
  5. Output Connections: Connect the test leads to the positive (red), negative (black), and ground (green) output plug interfaces as required for your application. Connect the other end of the test leads to your device.
  6. Software Installation (Optional): For advanced features like host computer screen projection and current curve visualization, install the dedicated software on your computer. Refer to the official SUNSHINE website or the provided QR code in the manual for software download and installation instructions.
SUNSHINE P4 PRO package contents
Figure 5: Package Contents. This image displays the SUNSHINE P4 PRO unit along with its accessories, including the power cable, test leads, and documentation.

5. Operating Instructions

5.1. Setting Voltage and Current

  1. Ensure the output is OFF (ON/OFF button is red).
  2. Rotate the Rotary Encoder to adjust the desired voltage. Press the encoder to switch between adjusting voltage and current.
  3. Rotate the Rotary Encoder to adjust the desired current limit.
  4. Press the V/C button to switch between voltage and current display modes or to adjust the curve time base when in curve visualization mode.
  5. Once settings are confirmed, press the ON/OFF button to enable the output. The button will turn green.
Setting Voltage and Current on SUNSHINE P4 PRO
Figure 6: Setting Voltage and Current. A close-up of the display showing the set voltage (30.00V) and current (6.000A), indicating the high-frequency output capability.

5.2. Memory Functions (M1-M4)

The unit allows you to store and recall up to four sets of voltage and current settings.

  • To Store Settings: Set your desired voltage and current. Long-press one of the M1-M4 buttons until the display indicates the settings are saved.
  • To Recall Settings: Short-press one of the M1-M4 buttons to load the stored settings.
Four Storage Channels M1-M4
Figure 7: Four Storage Channels. This image highlights the M1, M2, M3, and M4 buttons, indicating the unit's ability to store and recall four adjustable data sets.

5.3. Protection Functions (OCP, OVP)

  • Overcurrent Protection (OCP): Press the OCP button to enable or disable overcurrent protection. When enabled, the output will shut down if the current exceeds the set limit.
  • Overvoltage Protection (OVP): Press the OVP button to enable or disable overvoltage protection. When enabled, the output will shut down if the voltage exceeds a safe threshold.

5.4. Lock Function

Press the LOCK button to lock the current settings on the display, preventing accidental adjustments during operation.

5.5. Dual-Port Charging

The integrated Type-C and USB-A ports can be used to charge compatible devices. Connect your device to the appropriate port. The power supply will automatically detect the fast-charging protocol and display real-time voltage and current.

5.6. Upper Computer Function (Software Control)

Connect the power supply to your computer via a USB cable. Launch the dedicated software (e.g., RELIFE QUICK). This allows for:

  • Large-screen high-definition sharing and display of parameters.
  • Customization and adjustment of various parameters directly from the software interface.
  • Visualization of high-refresh current curves for detailed fault analysis.
SUNSHINE P4 PRO connected to computer with software
Figure 8: Host Computer Screen Projection. The power supply connected to a computer displaying the RELIFE QUICK software interface, demonstrating customizable adjustments and data visualization.
High-refresh Current Curve visualization
Figure 9: High-refresh Current Curve. This image shows the software interface displaying a detailed current curve, which helps in analyzing subtle current fluctuations for fault diagnosis.

6. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the exterior of the unit. Do not use abrasive cleaners or solvents.
  • Ventilation: Regularly check that the ventilation openings are clear of dust and debris.
  • Storage: When not in use for extended periods, store the power supply in a dry, dust-free environment.
  • Cable Inspection: Periodically inspect the power cord and test leads for any signs of damage. Replace if necessary.
  • Software Updates: Check the official SUNSHINE website for any available software or firmware updates to ensure optimal performance and new features.

7. Troubleshooting

ProblemPossible CauseSolution
Unit does not power on.No power from outlet; power cable loose; main power switch OFF.Check power outlet; ensure power cable is securely connected; flip main power switch to ON.
No output voltage/current.Output ON/OFF button is OFF; OCP/OVP activated; short circuit at output.Press output ON/OFF button; check for OCP/OVP indicators and reset; inspect connections for short circuits.
Incorrect voltage/current reading.Faulty test leads; incorrect settings.Replace test leads; re-verify voltage and current settings.
Software connection issues.USB cable not connected; driver issues; software not updated.Ensure USB cable is connected; install/update USB drivers; update software to the latest version.

8. Specifications

FeatureDetail
BrandSUNSHINE
Product NameDigital controlled DC power supply
ModelP4 Pro
Product Size115*270*165mm
Package Size340*210*260mm
Net Weight≈ 3.8kg
Gross Weight≈ 4.5kg
Voltage Range0~30V
Current Range0~6A
Load Effect≤0.01%+2mV/≤0.02%+10mA
Power Effect≤0.01%+3mV/≤0.1%+3mA
Output Resolution10mV/1mA
Setting Accuracy (25°C+15°C)≤0.5%+20mV/≤0.5%+5mA
Ripple (20-20m)≤2mVrms/≤3mArms
Output Temperature Coefficient150ppm
Readback Resolution1mV/1mA
Read Temperature Coefficient≤100ppm+10mV/≤100ppm+5mA
Response Time (10% rated load)≤100mS
USB-C OutputPD3.0/PPS/QC2.0/QC3.0/IP 5V.2.4A/AFC/FCP/SCP/HSCP
USB-A OutputQC2.0/QC3.0/IP 5V.2.4A/AFC/FCP/SCP/HSCP
MaterialMetal
TypeCombination
ApplicationPhone Repairing Tool Set
DIY SuppliesElectrical
Detailed Specifications Table for SUNSHINE P4 PRO
Figure 10: Detailed Specifications. A comprehensive table outlining the technical specifications of the SUNSHINE P4 PRO power supply.

9. User Tips

  • For sensitive electronics, always start with lower voltage and current settings and gradually increase them while monitoring the device.
  • Utilize the memory functions (M1-M4) to quickly switch between frequently used voltage/current presets for different repair tasks.
  • When using the upper computer software, take advantage of the current curve visualization to identify subtle anomalies in device behavior, which can be crucial for diagnosing complex faults.
  • Keep the firmware updated to benefit from performance improvements and new features.

10. Warranty and Support

For detailed warranty information and technical support, please refer to the official SUNSHINE documentation or contact the seller. A comprehensive user manual in PDF format is available for download:

Download User Manual (PDF)

© 2023 SUNSHINE. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.