PowMr PS-3K-110V

Contents

PowMr 2.4KW Pure Sine Wave Hybrid Inverter

Model: PS-3K-110V

User Instruction Manual

1. Introduction

The PowMr PS-3K-110V is a 2.4KW pure sine wave hybrid inverter designed to convert 24VDC to 110V/120VAC. It features a built-in 50A PWM solar charge controller, offering a comprehensive solution for off-grid and backup power systems. Utilizing full digital voltage and current double closed-loop control with advanced SPWM technology, this inverter achieves a charging efficiency of up to 95%.

This inverter is suitable for powering various appliances in home or office environments, including motor-type appliances such as tube lights, fans, refrigerators, and air conditioners. It is specifically designed for single-phase 110V-120V AC output systems.

2. Safety Instructions

Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury.

  • Ensure proper grounding of the inverter.
  • Do not disassemble the inverter; refer all servicing to qualified personnel.
  • Keep the inverter away from flammable materials and moisture.
  • Ensure adequate ventilation around the inverter to prevent overheating.
  • Verify that the battery voltage matches the inverter's input voltage (24VDC).
  • Always disconnect power before performing any wiring or maintenance.
  • The inverter provides comprehensive protection against short circuits, over-voltage, under-voltage, overload, and reverse polarity. However, proper installation is crucial to prevent these conditions.

3. Product Overview

The PowMr PS-3K-110V inverter is built with a sturdy aluminum alloy shell for durability and resistance against impact, oxidation, and deformation. It features an intelligent fan cooling system that adjusts speed based on load and temperature, ensuring efficient heat dissipation and preventing internal component damage.

PowMr 3KVA 110VAC Solar Hybrid Inverter
Figure 3.1: Front view of the PowMr PS-3K-110V Solar Hybrid Inverter.
Product appearance with labeled components
Figure 3.2: Rear and bottom view with labeled connection ports and controls.

3.1 Component Identification (Refer to Figure 3.2)

  • LCD Display: Shows system data and operating status.
  • Function Buttons: For navigating menus and setting parameters.
  • PV Input: Connection terminals for solar panels.
  • Power On/Off Switch: Main power control for the inverter.
  • Circuit Breaker: Overcurrent protection for AC input.
  • AC Input: Connection for utility grid power.
  • AC Output: Connection for household appliances.
  • RS232 Communication Port: For data monitoring and communication.
  • Dry Contact: For external control or signaling.
  • Battery Input: Connection terminals for the battery bank.
Professional LCD Display
Figure 3.3: Detailed view of the LCD display and control buttons.

4. Installation

Proper installation is critical for the safe and efficient operation of your hybrid inverter. Please follow these steps carefully.

4.1 Site Selection

  • Mount the inverter vertically on a wall in a well-ventilated area.
  • Ensure the ambient temperature is within the operating range (refer to specifications).
  • Avoid direct sunlight, moisture, and dust.
  • Maintain sufficient clearance around the inverter for airflow, especially around the cooling fan vents.

4.2 Wiring Diagram (Off-Grid System Example)

The following diagram illustrates a typical off-grid system setup. Consult a qualified electrician for complex installations.

Off-Grid System wiring diagram
Figure 4.1: Off-Grid System Diagram showing connections to PV panels, utility, generator, battery, and home appliances.

4.3 Connection Steps

  1. Battery Connection: Connect the 24V battery bank to the Battery Input terminals (refer to Figure 3.2). Ensure correct polarity (+ to + and - to -).
  2. PV Panel Connection: Connect your solar PV panels to the PV Input terminals. Ensure the maximum open circuit voltage does not exceed 80VDC.
  3. AC Input Connection (Optional): If connecting to a utility grid or generator, connect the AC source to the AC Input terminals.
  4. AC Output Connection: Connect your household appliances or load center to the AC Output terminals.
  5. Communication (Optional): Connect the RS232 port for monitoring software if desired.

WARNING: All wiring must be performed by a qualified professional and comply with local electrical codes. Incorrect wiring can cause severe damage to the inverter, batteries, and connected appliances, and poses a risk of electric shock or fire.

5. Operation

The inverter features an LCD screen and three LED indicators for dynamic display of system data and operating status. Use the function buttons (Up, Down, Enter) to navigate menus and adjust settings.

5.1 Initial Power-Up

  1. After all connections are secure, switch on the battery breaker (if applicable).
  2. Turn on the main power switch on the inverter (refer to Figure 3.2).
  3. The LCD display will light up, and the inverter will perform a self-test.
  4. Observe the LED indicators for status (e.g., AC/Inverter, Charge, Fault).

5.2 Charging Modes

The inverter offers four selectable charging modes:

  • Solar Priority: Solar power is the primary source for charging batteries and supplying loads. Utility power is used only when solar power is insufficient.
  • Utility Priority: Utility power is the primary source. Solar power is used when utility power is unavailable.
  • Solar/Utility Hybrid Charging: Combines solar and utility power for charging, prioritizing solar.
  • Solar Only: Only solar power is used for charging.

5.3 Output Modes

Three output modes can be configured to meet different application needs:

  • PV Priority: Solar power is the primary source for loads. If solar is insufficient, it switches to battery or utility (depending on configuration).
  • Utility Priority: Utility power is the primary source for loads. If utility is unavailable, it switches to battery.
  • Inverter Priority: Battery power (charged by solar or utility) is the primary source for loads.

5.4 Cold Start Function

The inverter features a cold start function, allowing it to automatically restart when AC power recovers after an outage.

Inverter with cold start function
Figure 5.1: Inverter highlighting the cold start function.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

  • Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure cooling vents are free from dust and debris to maintain efficient fan operation.
  • Connections: Annually check all electrical connections for tightness and corrosion. Loose connections can cause overheating and poor performance.
  • Battery Inspection: Regularly inspect your battery bank for any signs of damage, corrosion, or leakage. Ensure battery terminals are clean and tight.
  • Environment: Ensure the installation environment remains within specified temperature and humidity limits.

7. Troubleshooting

The inverter is equipped with multiple protection functions to ensure stable and secure operation. If an issue occurs, the LCD display may show an error code or the fault indicator may light up.

Multiple Protection Functions
Figure 7.1: Inverter's built-in protection mechanisms.

7.1 Common Protection Triggers

  • Short Circuit Protection: Occurs if there is a short circuit in the output wiring or connected appliances. Disconnect loads and check wiring.
  • Over Temperature Protection: Activates if the inverter's internal temperature exceeds safe limits, often due to insufficient ventilation or excessive load. Ensure clear vents and reduce load.
  • Over-Load Protection: Engages if the connected load exceeds the inverter's rated capacity (3000W). Reduce the total load.
  • Low Voltage Protection: Triggers if the battery voltage drops below a safe operating level. Recharge or replace batteries.
  • Over-Voltage Protection: Activates if the input voltage (e.g., from PV panels) exceeds the maximum allowed (80VDC). Check PV array configuration.
  • Reverse Polarity Protection: Prevents damage if battery connections are reversed. Double-check battery wiring.

For specific error codes and detailed troubleshooting steps, please refer to the comprehensive manual provided with your product or contact customer support.

8. Specifications

Feature Specification (PS-3K-110V)
Rated Power 3000VA / 2400W
DC Input Voltage 24VDC
AC Output Voltage 120VAC ±10%
AC Output Frequency 60Hz
Waveform Pure Sine Wave
Max. PV Array Open Circuit Voltage 80VDC
Solar Charger Type PWM
Max. Solar Charge Current 50A
Battery Voltage 24V
Overload Protection 5s @ >150% load; 10s @ 110%~150% load
Surge Capacity 2 * rated power for 5 seconds
Dimensions (L*W*D) 100 x 272 x 355 mm
Product Weight 6.9 kg
Application Home
Work Time 24 hours
Certification CE
Inverter dimensions and specifications
Figure 8.1: Key dimensions and specifications of the PS-3K-110V model.

9. User Tips

Based on common user experiences and product features:

  • For optimal performance and battery life, ensure your 24V battery bank is adequately sized for your expected load and solar input.
  • Regularly monitor the LCD display for system status and any alerts to catch potential issues early.
  • When connecting motor-type appliances, be mindful of their surge power requirements, which can be significantly higher than their running wattage. The inverter's surge capacity is 2 times its rated power for 5 seconds.
  • Keep the inverter's cooling vents clear to prevent overheating, especially during high load operation or in warm environments.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the documentation included with your purchase or contact PowMr customer service directly. Ensure you have your product model number (PS-3K-110V) and purchase details available when seeking support.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.