1. Introduction
This manual provides instructions for the installation, operation, and maintenance of the LEFOO LF18 Series Pressure Switch. This device is designed for use with three-phase electric air compressors or water pumps to regulate system pressure, ensuring operation within preset pressure values. It features a pressure relief valve and a manual switch for convenient control.
2. Specifications
The LEFOO LF18 series pressure switches are available in various configurations. Key specifications are detailed below:
| Attribute | Value |
|---|---|
| Brand | LEFOO |
| Model Series | LF18 (LF18-1H, LF18-4H, etc.) |
| Material | Plastic |
| Type | Other (Pressure Control) |
| Origin | Mainland China |
| High-concerned chemical | None |
Technical Parameters (LF18 Series)
| Model | Pressure Adjustment Range (Kgf/cm²) | Differential Pressure Adjustment Range (Kgf/cm²) | Factory Setting Pressure (Kgf/cm²) | Rated Voltage/Current | Contact Type | Interface Type |
|---|---|---|---|---|---|---|
| LF18 | 1.0-5.0 | 0.5-3.0 | 3.0-8.0 | 400VAC-3/16A/25A | Normally Open | 1/4 or 1/2NPT, G1/4 or G1/2 internal thread |
| LF18 | 2.0-8.0 | 1.0-3.0 | 5.0-8.0 | 400VAC-3/16A/25A | Normally Open | 1/4 or 1/2NPT, G1/4 or G1/2 internal thread |
| LF18 | 3.0-11.0 | 1.4-4.0 | 5.6-7.0 | 400VAC-3/16A/25A | Normally Open | 1/4 or 1/2NPT, G1/4 or G1/2 internal thread |
| LF18 | 4.0-16.0 | 1.8-4.5 | 8.0-10.0 | 400VAC-3/16A/25A | Normally Open | 1/4 or 1/2NPT, G1/4 or G1/2 internal thread |
Pressure Conversion: 1 Kgf/cm² = 14.2 PSI = 1 Bar = 14.5 PSI
Power: Up to 4KW (for LF18-1H model)
3. Setup and Installation
The LEFOO LF18 pressure switch is designed for easy installation on air compressor or water pump systems. Ensure all power is disconnected before beginning installation.
- Select the Correct Model: Choose the appropriate LF18 model (e.g., LF18-1H, LF18-4H) based on your system's pressure requirements and interface type.
- Prepare Connections: Identify the pressure inlet and electrical connections on the switch. The switch typically features a pressure relief valve at the bottom for convenient installation.
- Install Pressure Connection: Connect the pressure switch to your air compressor or water pump system using the appropriate interface type (e.g., 1/4 NPT, G1/4). Ensure a secure, leak-free connection.
- Electrical Wiring: Connect the pressure switch to the three-phase power supply and the air compressor/water pump motor. Refer to the technical parameters for rated voltage and current (e.g., 400VAC-3/16A/25A). Ensure wiring is done by a qualified professional and adheres to local electrical codes.
- Pressure Setting: Adjust the pressure settings according to your system's requirements. The pressure adjustment range and differential pressure adjustment range are listed in the specifications table.
4. Operating Instructions
Once installed and wired correctly, the LEFOO LF18 pressure switch operates automatically to maintain system pressure within the set limits. It also features a manual ON/OFF switch for direct control.
- Power On: Ensure the main power supply to the compressor/pump system is switched on.
- Manual Operation: Use the red ON/OFF button on the top of the switch to manually start or stop the connected equipment.
- Automatic Operation: The pressure switch will automatically start the compressor/pump when the system pressure drops below the lower set point and stop it when the pressure reaches the upper set point.
- Pressure Relief Valve: The integrated pressure relief valve allows for manual depressurization of the system before starting, which can be useful for certain applications or maintenance.
5. Maintenance
Regular maintenance helps ensure the longevity and reliable operation of your LEFOO LF18 pressure switch. Always disconnect power before performing any maintenance.
- Regular Inspection: Periodically check the switch for any signs of wear, damage, or loose connections.
- Cleanliness: Keep the switch free from dust, dirt, and moisture. Use a dry, soft cloth for cleaning.
- Connection Integrity: Verify that all pressure and electrical connections remain tight and secure.
- Pressure Calibration Check: If precise pressure control is critical, periodically verify the switch's calibration against a known accurate pressure gauge.
No specific maintenance schedule or procedures are provided beyond general inspection and cleaning.
6. Troubleshooting
This section provides general guidance for common issues. For complex problems, consult a qualified technician.
- Equipment does not start:
- Check main power supply.
- Ensure the manual ON/OFF button is in the 'ON' position.
- Verify electrical connections are secure.
- Check if the pressure is already above the upper set point.
- Equipment does not stop:
- Check if the pressure is not reaching the upper set point (e.g., due to a leak in the system).
- Verify the pressure setting.
- Ensure the manual ON/OFF button is not stuck.
- Inaccurate Pressure Readings/Control:
- Check for blockages in the pressure sensing line.
- Recalibrate the pressure switch if possible, or replace if faulty.
No specific troubleshooting steps are provided in the product description. The above are general suggestions.
7. User Tips
No specific user tips were available from provided reviews or Q&A for this product.
8. Warranty and Support
Warranty:
- New products come with a 6-month warranty.
- Used products come with a 30-day warranty.
- A 7-day no-reason refund policy is available.
Support:
For any needs or inquiries, you can consult the seller. Support is available 24 hours a day.