MYAMI TPR3005-2D

Contents

MYAMI TPR3005-2D Dual Output DC Power Supply User Manual

Model: TPR3005-2D

1. Introduction

The MYAMI TPR series is a high-precision DC power supply designed for various applications requiring stable and adjustable power. This model, the TPR3005-2D, features dual adjustable outputs and a fixed 5V/3A output, making it versatile for scientific research, educational experiments, electronic production line testing, and communication equipment maintenance. It incorporates voltage stabilization and automatic constant current conversion functions, built with a power loss control circuit, operational amplifier, and a temperature-compensated reference voltage regulator to ensure reliable performance.

Front view of the MYAMI TPR3005-2D dual output DC power supply, showing digital displays for current and voltage for both channels.

Figure 1: Front view of the MYAMI TPR3005-2D DC Power Supply.

2. Safety Instructions

  • Always connect the power supply to a grounded outlet.
  • Do not operate the device in wet or damp conditions.
  • Ensure proper ventilation to prevent overheating. Do not block the ventilation openings.
  • Before making any connections or adjustments, ensure the power supply is turned off.
  • Avoid touching live terminals.
  • In case of smoke, unusual odors, or abnormal operation, immediately disconnect the power supply from the mains and contact qualified service personnel.
  • Only use accessories and cables specified by the manufacturer.

3. Product Overview

3.1. Features

  • Simple and elegant appearance.
  • Easy to operate and cost-effective.
  • Two adjustable channels (CH1, CH2) and one fixed 5V/3A output.
  • Adjustable channels can be used independently, or automatically configured in series or parallel without external connections.
  • Independent two-way constant voltage (CV) and constant current (CC) automatic conversion function.
  • Low ripple noise and high reliability.
  • Equipped with current limiting protection.

3.2. Front Panel Description

The front panel provides all necessary controls and output terminals for operating the power supply.

Detailed diagram of the front panel, labeling all knobs, buttons, and output terminals for Channel 1 (CH1), Channel 2 (CH2), and the fixed 5V/3A output.

Figure 2: Front Panel Layout and Controls.

  • Current Knob (CH1/CH2): Adjusts the current limit for each channel.
  • Voltage Knob (CH1/CH2): Adjusts the output voltage for each channel.
  • Power ON/OFF Button: Toggles the main power to the unit.
  • CH1 Output Terminals: Positive (+), Negative (-), and Ground (GND) for Channel 1.
  • CH2 Output Terminals: Positive (+), Negative (-), and Ground (GND) for Channel 2.
  • INDEP/SERIES/PARALLEL Switch: Selects independent, series, or parallel operation mode for CH1 and CH2.
  • TRACKING Switch: Enables tracking mode for synchronized voltage adjustment.
  • 5V 3A Output: Fixed 5V, 3A output terminals.
  • Digital Displays: Show real-time current (AMP) and voltage (VOLT) for each channel.

4. Technical Specifications

General Specifications
Parameter Value
Model Number TPR3005-2D
Output Voltage (Adjustable) 2 x 0-30V
Output Current (Adjustable) 2 x 0-5A
Fixed Output 5V/3A
Input Voltage 110V / 220V ± 10% (Switchable), 50Hz/60Hz
Efficiency 85%
Cooling Air Cooling
Working Temperature -10 ℃ to 40 ℃
Storage Temperature -10 ℃ to 70 ℃
Relative Humidity (Operating) < 80%
Relative Humidity (Storage) < 70%
Dimensions (L*W*H) 340*260*155mm
Weight 12kg

4.1. Performance Specifications

Voltage Stabilization State
Parameter Value
Voltage Stability ≤ 0.01% + 2mV
Load Stability ≤ 0.2% + 2mV
Recovery Time ≤ 100us
Ripple Noise ≤ 1mVrms (effective value)
Temperature Coefficient ≤ 300PPM/℃
Steady Current State
Parameter Value
Current Stability ≤ 0.1% + 3mA
Load Stability ≤ 0.2% + 3mA
Ripple Noise ≤ 3mArms (effective value)
Display Accuracy
Parameter Value
Voltage Display Accuracy Three digit LED digital display ± 1% ± 1 word
Current Display Accuracy Three digit LED digital display ± 2% ± 1 word
Fixed 5V/3A Output
Parameter Value
Voltage Accuracy 5V ± 3%
Power Effect ≤ 1 × 10-4 + 1mV
Negative Effect ≤ 1 × 10-3
Ripple and Noise ≤ 0.5mvrms

5. Setup and Operation

5.1. Initial Setup

  1. Unpack the power supply and inspect for any damage.
  2. Ensure the input voltage switch (usually located on the rear panel) matches your local mains voltage (110V or 220V).
  3. Connect the power cord to the power supply and then to a grounded electrical outlet.
  4. Press the Power ON/OFF button to turn on the unit. The digital displays should illuminate.

5.2. Independent Operation (CH1 and CH2)

In independent mode, Channel 1 (CH1) and Channel 2 (CH2) operate as two separate power supplies.

  1. Set the INDEP/SERIES/PARALLEL switch to 'INDEP'.
  2. Connect your load to the CH1 output terminals (red for +, black for -).
  3. Adjust the CH1 Voltage Knob to set the desired output voltage.
  4. Adjust the CH1 Current Knob to set the desired current limit.
  5. Repeat steps 2-4 for CH2 if using both channels independently.
The MYAMI multi-channel DC power supply showing its dual adjustable 30V/5A channels and a constant 5V/3A channel, with digital displays.

Figure 3: Independent operation of dual channels.

5.3. Parallel Connection for Increased Current

To combine the current output of both channels, connect them in parallel. This configuration provides a combined output of 0-30V and 0-10A for the TPR3005-2D model.

  1. Ensure the power supply is OFF.
  2. Set the INDEP/SERIES/PARALLEL switch to 'PARALLEL'.
  3. Connect the positive (+) terminal of CH1 to the positive (+) terminal of CH2.
  4. Connect the negative (-) terminal of CH1 to the negative (-) terminal of CH2.
  5. Connect your load to the combined positive and negative terminals (e.g., CH1+ and CH1-).
  6. Turn on the power supply. The MASTER channel (usually CH2) controls the voltage and current for both.
  7. Adjust the MASTER channel's Voltage and Current Knobs to set the desired output.
Wiring diagram illustrating how to connect the two channels of the power supply in parallel for increased current output.

Figure 4: Parallel Wiring Diagram.

5.4. Series Connection for Increased Voltage

To combine the voltage output of both channels, connect them in series. This configuration provides a combined output of 0-60V and 0-5A for the TPR3005-2D model.

  1. Ensure the power supply is OFF.
  2. Set the INDEP/SERIES/PARALLEL switch to 'SERIES'.
  3. Connect the positive (+) terminal of CH1 to the negative (-) terminal of CH2.
  4. Connect your load to the remaining free positive terminal (CH2+) and negative terminal (CH1-).
  5. Turn on the power supply. The MASTER channel (usually CH2) controls the voltage and current for both.
  6. Adjust the MASTER channel's Voltage and Current Knobs to set the desired output.
Wiring diagram illustrating how to connect the two channels of the power supply in series for increased voltage output.

Figure 5: Series Wiring Diagram.

5.5. Using the Fixed 5V/3A Output

The power supply includes a dedicated fixed 5V/3A output for convenience.

  1. Connect your 5V compatible device to the dedicated 5V/3A output terminals.
  2. This output is always active when the power supply is ON and does not require adjustment via the knobs.
The power supply demonstrating its fixed 5V/3A output, with a multimeter connected and showing 5.0V.

Figure 6: Fixed 5V/3A output in use.

6. Maintenance

  • Cleaning: Disconnect the power supply from the mains before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use abrasive cleaners or solvents.
  • Ventilation: Regularly check that the ventilation openings are clear of dust and debris to ensure proper airflow and prevent overheating.
  • Storage: When not in use for extended periods, store the power supply in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Internal Inspection: Internal inspection and maintenance should only be performed by qualified service personnel.

7. Troubleshooting

  • No Power: Check the power cord connection and ensure the mains switch is ON. Verify the input voltage selector (if present) is set correctly.
  • No Output Voltage/Current: Ensure the output terminals are correctly connected to the load. Check if the current limit is set too low for the load.
  • Overload Protection: If the power supply enters constant current (CC) mode unexpectedly or shuts down, it may be due to an overload. Reduce the load or increase the current limit.
  • Unstable Output: Check for loose connections. Ensure the load is within the power supply's specifications.

8. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.