ATORCH 150W CC Electronic Load 200V 20A

Contents

ATORCH Electronic Load Battery USB Tester User Manual

Model: 150W CC Electronic Load with 200V 20A

1. Product Overview

The ATORCH Electronic Load Battery USB Tester is a versatile industrial-grade constant current discharge load designed for testing batteries (lead-acid, lithium), USB chargers, power banks, and various DC power supplies. It features real-time monitoring of voltage, current, power, capacity, energy, time, and temperature, with adjustable current and comprehensive protection settings.

ATORCH Electronic Load Battery USB Tester
Figure 1: ATORCH Electronic Load Battery USB Tester - Top View

This image shows the main unit with its large heatsink and red fan, the LCD display, control knobs, and various input/output ports.

2. Package Contents

Please check the package for the following items:

  • ATORCH Electronic Load Battery USB Tester Unit
  • Power Adapter (9V/1A ADP)
  • Alligator Clip Cables (x2)
  • USB Alligator Clip Cable (x1)
  • User Manual (this document)
  • EU Adapter (if applicable)
Package Contents of ATORCH Electronic Load
Figure 2: Package Contents

The image displays the electronic load unit, power adapter, EU adapter, alligator clips, and a small instruction sheet.

3. Setup and Connections

3.1 Safety Warnings

  • Prevent Burning: Before connecting any power source or starting a test, always rotate both current adjustment knobs (coarse and fine) fully counter-clockwise to their minimum (0.00A) position. Slowly increase the current during testing. Instantaneous high current can damage the discharge tube.
  • Electrical Shock Hazard: When testing voltages above 36V, exercise extreme caution to avoid electric shock.
  • Power Limit: Ensure that the product of the voltage and current (power) does not exceed 150W to prevent damage to the device.
  • Multiple Power Sources: Do not connect several power sources simultaneously to avoid over-voltage or over-current damage.

3.2 Powering the Device

The ATORCH Electronic Load can be powered by two methods:

  • DC 5.0 Power Supply: Connect a DC 6-12V power adapter to the DC 5.0 jack input.
  • Micro USB Power Supply: Connect a DC 4-30V power source via the Micro USB port.
Two Power Supply Methods
Figure 3: Power Supply Options

This image illustrates the two ways to power the device: via the DC 5.0 jack or the Micro USB port.

3.3 Interface Overview

Interface Function Instruction
Figure 4: Interface Diagram and Function Instruction

This detailed diagram labels all ports, controls, and display elements of the electronic load.

  • Power Supply Interface: DC6-12V input.
  • Fan Interface: For external cooling fan connection.
  • Multi-purpose USB Port: Supports Qualcomm Quick Charge QC2.0/3.0 trigger, etc.
  • DC Input (+/-): Main terminals for connecting the device under test.
  • DC 5.0 Jack Input: Power input.
  • MINI USB, Micro USB, Type-C USB Inputs: For testing various USB devices and power supplies.
  • DC Output/Current Increase: Output terminals.
  • Current Adjust (Fine/Coarse): Knobs to precisely adjust the discharge current.
  • Alert Speaker: Provides audible warnings.
  • Protection Controlling Signal Output: For external control.
  • Multi-Functional Key: Used for function switching, zero data, and parameter setup.

4. Operating Instructions

4.1 Basic Operation Sequence

  1. Initial Setup: Ensure the device is powered on. Rotate both the fine and coarse current adjustment knobs fully counter-clockwise to their minimum (0.00A) setting.
  2. Connect Device Under Test: Connect the power supply, battery, or charger you wish to test to the appropriate input terminals (DC Input, USB ports) as shown in Figure 4. The input voltage will be displayed.
  3. Reset Data (Optional): Press and hold the Multi-Functional Key to reset all accumulated data (mAh, Wh, time) to zero before starting a new test.
  4. Adjust Current: Slowly rotate the current adjustment knobs clockwise to increase the discharge current to your desired test value. Prioritize using the fine adjustment knob for precise control, and use the coarse knob for larger current adjustments.
  5. Monitor Display: Observe the real-time parameters on the LCD display.

4.2 Display Parameters

Display Parameter Labels
Figure 5: LCD Display Parameters

This image labels each data point on the LCD: Voltage, Capacity, Quantity of electricity, Time, Current, Capacity coefficient, Temperature, and Timing settings.

  • Vol (Voltage): Input voltage in Volts (V).
  • Cur (Current): Discharge current in Amperes (A).
  • Cap (Capacity): Accumulated discharge capacity in Ampere-hours (Ah).
  • Ene (Energy): Accumulated discharge energy in Watt-hours (Wh).
  • Time: Elapsed test time (HH:MM:SS).
  • Temp (Temperature): Device temperature in Celsius (°C).
  • Capacity Coefficient: (1.00) Default.
  • Timing Settings: ON/OFF for timer function.

4.3 Multi-Functional Key Operations

  • Single Click: Switch between display windows or enter setup mode for background light/parameters.
  • Double Click: Clear capacity data.
  • Three Clicks: Clear energy data.
  • Four Clicks: Clear time data.
  • Five Clicks: Activate Auto-Standby Mode & Timer for discharge alert.
  • Press Long: Clear all data (mAh, Wh, Time).
  • Quick 7 Clicks (without load): Reset current data to 0.00A for precise calibration.
  • Press & Hold during Power-On: Enter Background setup window for High&Low Voltage over-load settings. Single/double click to adjust parameters. Long press to reset to default setup.

4.4 Protection Settings

The device features adjustable warning thresholds for safe operation:

Product Warning Settings
Figure 6: Warning Settings and Alarms

This image shows the visual alerts for overvoltage, low voltage, overcurrent, and power overload conditions.

  • Overvoltage Warning: Default >300V. Adjustable from 1V to 300V.
  • Lowvoltage Warning: Default <0.00V. Adjustable from 0.00V to 290V. Essential for battery testing to prevent over-discharge.
  • Overcurrent Warning: Default >1.00A. Adjustable from 0.2A to 100A.
  • Power Overload Warning: Default >9.50W. Adjustable from 1.00W to 185W.

When a set threshold is exceeded, the tester will emit a rapid alarm sound and display a warning message, reminding the user to stop the discharge process.

4.5 Specific Test Scenarios

  • Battery Capacity Test: Connect the battery to the DC Input terminals. Set a low voltage discharge limit to protect the battery. The capacity (Ah) will be accumulated. Formula: Capacity (Ah) = Time (H) x Current (A).
  • PD Charger Test: This load does not have a built-in PD trigger function. To test PD chargers, it must be combined with an external PD trigger. Alternatively, a USB to Type-C data cable can be used for basic testing.
PD Charger Test Method
Figure 7: PD Charger Testing Diagram

This diagram illustrates how to connect a PD charger for testing, emphasizing the need for a PD trigger.

5. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Heat Dissipation: The cooling fan automatically starts when the current exceeds 0.5A or the temperature rises above 45°C. Ensure the fan is not obstructed during operation. The device can be modified for enhanced heat dissipation if required for prolonged high-power tests.
Enhanced Heat Dissipation
Figure 8: Device Back with Heat Sinks

This image shows the underside of the PCB with additional heat sinks, indicating potential for modification to improve cooling.

6. Troubleshooting

  • Device Not Powering On: Check the power supply connection and ensure it meets the voltage requirements (DC 6-12V for DC 5.0 jack, DC 4-30V for Micro USB).
  • No Current Adjustment: Ensure both current knobs are not at their minimum position. Check connections to the device under test.
  • Overload/Overheat Alarm: If the alarm sounds, immediately reduce the current or disconnect the load. Check the protection settings and ensure the test parameters are within the device's limits (max 150W). Allow the device to cool down if it's overheating.
  • Inaccurate Readings: Ensure proper connections. If current readings are consistently off, perform the 7-click current reset (without load) for calibration. Avoid calibrating voltage or current without standard instruments.

7. Specifications

ParameterValue
Supply Voltage InterfaceDC6-12V / DC 5.0 or Micro USB
Voltage Measure Range0.00V~200V (Accuracy: 0.05V)
Current Adjustable Range0.00A~20A (Accuracy: 0.05V)
Capacity Measure Range0~999.999Ah (Accuracy: 0.01Ah)
Power Cumulative Range0~9999.9Wh (Accuracy: 0.01Wh)
Power Measure Range0~2999.99W (Accuracy: 0.01W)
Impedance Measure Range1~999.9 Ohm (Accuracy: 0.01)
Temperature Range0~99°C (Accuracy: 1°C)
Max Timing999:59:59 (H:M:S)
Cooling Fan Power<150W / <180W (Fan can be changed)
Fan Controlling TypeAuto-start when current >0.5A or temp >45°C
Input/Output InterfacesUSB bit/alligator + USB
Refresh Time>500ms/time
Measure RateAbout 2s/time
Protecting Voltage Setting Range1~300V
Low Voltage Setting Range0~149V
Protecting Current Setting Range0.2~100A
Protecting Power Setting Range185W
Display TypeLCM module, black font, white backlit, Chinese&English
Size160mm x 96mm x 58mm
Consumption Current<1.5A
Operating Temperature-10~60°C
Operating Humidity10~80% (Non-condensing)
Operating Pressure80~106kPa
Device Dimensions
Figure 9: Device Dimensions

The image shows the dimensions of the unit: 156mm length, 96mm width, and 58mm height (including fan).

8. User Tips

  • Start Low, Go Slow: Always begin tests with current knobs at minimum and increase gradually to prevent sudden overloads.
  • Monitor Temperature: For prolonged high-power discharge tests, keep an eye on the device's temperature and ensure adequate ventilation.
  • Battery Protection: When testing batteries, always set a low voltage discharge limit to prevent irreversible damage from over-discharge.
  • Correct Power Supply: Use a stable and appropriate power supply for the electronic load itself to ensure accurate and reliable operation.

9. Warranty and Support

For warranty information and technical support, please refer to the seller's policies or contact the point of purchase. Keep your proof of purchase for any warranty claims.

© 2023 ATORCH. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.