DOOYA DM59M-80/15, DM59M-120/9

Contents

DM59M Series Tubular Motor Instruction Manual

Models: DM59M-80/15, DM59M-120/9

1. Product Overview

The DM59M series tubular motors are designed for rolling shutter doors, offering reliable and efficient operation. These motors are suitable for various applications requiring automated opening and closing of shutters. This manual provides essential information for the safe and effective installation, operation, and maintenance of your DM59M-80/15 or DM59M-120/9 tubular motor.

Video 1: Product demonstration of the DM59M series tubular motor.

2. Safety Instructions

  • Read all instructions carefully before installation and operation.
  • Installation must be performed by a qualified electrician or technician.
  • Ensure the power supply is disconnected before performing any installation, maintenance, or repair work.
  • Do not allow children to play with the remote control or operate the shutter.
  • Keep hands and loose clothing clear of the shutter and motor during operation.
  • Ensure the motor is correctly grounded to prevent electrical shock.

3. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your tubular motor. Refer to the wiring diagrams and motor specifications for correct connections and limit settings.

3.1 Unpacking and Inspection

  • Carefully remove the motor from its packaging.
  • Inspect the motor for any signs of damage during transit. Do not install if damaged.
  • Verify that all components listed in the packing list are present.
DM59M-80/15 Tubular Motor in its packaging

Image 1: DM59M-80/15 Tubular Motor as received in its protective packaging.

DM59M-120/9 Tubular Motor in its packaging

Image 2: DM59M-120/9 Tubular Motor as received in its protective packaging.

3.2 Mounting the Motor

Mount the tubular motor securely within the rolling shutter's tube or housing according to the shutter system's design. Ensure the motor is level and properly aligned to prevent undue stress on the mechanism.

3.3 Electrical Wiring

Connect the motor to the power supply and control unit as per the wiring diagram provided on the motor label. Ensure all connections are secure and insulated.

Close-up of DM59M-80/15 motor head showing wiring diagram and limit adjustment screws

Image 3: DM59M-80/15 Motor head with wiring diagram (L, N, Up, Down, Earth) and limit adjustment screws.

Close-up of DM59M-120/9 motor head showing wiring diagram and limit adjustment screws

Image 4: DM59M-120/9 Motor head with wiring diagram (L, N, Up, Down, Earth) and limit adjustment screws.

Wiring Key:

  • L: Live (Phase)
  • N: Neutral
  • Up: Control wire for upward movement
  • Down: Control wire for downward movement
  • Earth: Ground connection

3.4 Setting Limit Switches

The motor features adjustable limit switches to define the upper and lower stopping points of the shutter. Use the adjustment screws on the motor head (indicated by '+' and '-' symbols) to set these limits. Turn the screws to fine-tune the travel range. Refer to the specific instructions for your remote control system for programming the remote with the motor.

4. Operating Instructions

The DM59M series motors are designed for remote control operation. Once installed and limits are set, use your compatible remote control to operate the shutter.

  • Up Button: Press to raise the shutter.
  • Down Button: Press to lower the shutter.
  • Stop/Middle Button: Press to stop the shutter at any desired position.

Ensure a clear line of sight between the remote control and the receiver (if external) or the motor's integrated receiver for optimal performance.

5. Maintenance

Regular maintenance ensures the longevity and smooth operation of your tubular motor.

  • Annual Inspection: Check the motor and shutter mechanism annually for wear and tear, loose connections, or obstructions.
  • Cleaning: Keep the motor and surrounding area free from dust and debris. Do not use harsh chemicals or abrasive cleaners.
  • Lubrication: The motor itself is generally maintenance-free. However, ensure that the rolling shutter's tracks and moving parts are clean and adequately lubricated as per the shutter manufacturer's recommendations.
  • Power Supply: Periodically check the power cable for any damage. Replace immediately if damaged.

6. Troubleshooting

If you encounter issues with your tubular motor, refer to the following common troubleshooting steps:

ProblemPossible CauseSolution
Motor does not respond to remote control.No power, remote battery low, remote not paired, receiver fault.Check power supply, replace remote battery, re-pair remote, inspect receiver.
Shutter stops prematurely or does not reach full open/close.Limit switches incorrectly set, obstruction in shutter path.Adjust limit switches, remove any obstructions.
Motor makes unusual noise.Mechanical issue with shutter, motor fault.Inspect shutter mechanism for damage or misalignment. If motor fault, contact support.
Motor overheats and stops.Overuse, excessive load, ventilation issue.Allow motor to cool down. Reduce frequency of operation. Check for obstructions increasing load.

If the problem persists after attempting these solutions, please contact customer support.

7. Specifications

Below are the technical specifications for the DM59M series tubular motors:

FeatureDM59M-80/15DM59M-120/9
Voltage230V/240V
Frequency50/60Hz
Current1.0A1.2A
Power100W150W
Torque80N.m120N.m
Speed15r/min9r/min
Duty CycleS3-4min
Insulation ClassH
DIY Supplies CategoryElectrical
OriginMainland China
CertificationNONE

8. Warranty and Support

For warranty information and technical support, please refer to the documentation provided by your retailer or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.

9. User Tips

  • Professional Installation: For safety and optimal performance, it is highly recommended to have the motor installed by a certified professional.
  • Remote Control Pairing: If you are using a new remote control or experiencing issues, ensure it is correctly paired with the motor according to the remote control's specific instructions.
  • Regular Checks: Periodically check the shutter's movement for any signs of friction or obstruction, which can put strain on the motor.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.