1. Introduction and Safety Information
Thank you for purchasing the DATOUBOSS Solar Hybrid Inverter. This manual provides important information, guidelines, and instructions for the installation, operation, and maintenance of your inverter. Please read this manual carefully before use and keep it for future reference.
1.1. Copyright Statement
DATOUBOSS is committed to technological innovation and providing better products and services. Product design and technical specifications are subject to change without prior notice. The product is subject to the actual item.
1.2. Safety Instructions
This section contains critical safety information. Please read and save this manual for future reference.

Image 1: Safety Symbols and their meanings.
- DANGER: Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
- WARNING: Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
- CAUTION: Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
- NOTICE: Provides tips for product operation.
1.3. General Safety Guidelines
- Always install the inverter in compliance with local requirements and regulations.
- Be careful with high voltage. Turn off all power switches before and during installation to avoid electric shock.
- To ensure optimal performance, select appropriate cable sizes and necessary protective devices.
- Do not connect or disconnect any wires while the inverter is operating.
- Do not open the terminal cover while the inverter is operating.
- Ensure the inverter is properly grounded.
- Avoid short-circuiting AC output and DC input.
- Do not disassemble the unit. All repairs and maintenance should be performed by a professional service center.
- Do not charge frozen batteries.
WARNING: This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take practical measures to reduce the interference.
2. Product Overview
The DATOUBOSS 12V 1800W Solar Hybrid Inverter is designed to provide reliable power for various applications, integrating solar charging, AC charging, and inverter functions into one unit. It supports battery-less operation and features ultra-fast transfer time.
2.1. Product Appearance

Image 2: Various views of the inverter.
2.2. Dimensions and Wall Mounting
The inverter is designed for wall-mounted installation. Ensure sufficient space around the unit for proper ventilation.

Image 3: Product dimensions (Height: 310mm, Width: 250mm, Depth: 91mm).
For wall mounting, use M4x6 screws to fix the wall bracket to the machine. For the inverter itself, use M6 expansion screws (user-supplied) at the specified mounting hole distances. Refer to the diagram for mounting hole positions.
2.3. Control Panel and Interfaces
The inverter features an LCD display, LED indicators, and functional buttons for operation and monitoring. Various connection terminals are located on the unit.

Image 4: Detailed view of the control panel and connection interfaces.
Key Components:
- LCD Display
- LED Indicators (AC, INV, CHG, FAULT)
- Function Buttons (DOWN, ESC, ENTER, UP)
- Power On/Off Switch
- Battery Connection Terminals
- PV Input Terminals
- AC Input (Grid) Terminal
- AC Output (Load) Terminal
- RS485-2 Communication Interface (BMS)
- RS485-1 Communication Interface (External Communication/WIFI)
NOTICE: The images may differ slightly from the actual product. Refer to the appendix for detailed interface definitions.
3. Setup Instructions
3.1. Unpacking and Inspection
Upon opening the package, check for the following:
- User manual (including warranty card and certificate of conformity).
- Optional accessories (if applicable).
- Inspect the inverter for any damage during transit. Do not power on if damaged or if parts are missing. Contact your carrier and dealer immediately.
NOTICE:
- Retain the original packaging for future transport.
- This product is heavy; handle with care during transport.
3.2. Installation Environment
- Install the unit in a well-ventilated area, away from water, flammable gases, and corrosive substances.
- The inverter is wall-mounted; ensure both side air inlets and bottom air outlets are unobstructed.
- Maintain an ambient temperature between -10°C and 50°C.
- If the unit is moved from a cold to a warm environment, condensation may occur. Wait until the unit is completely dry inside and out before installation to avoid electric shock.
- If the unit has been stored for a long time, ensure it is completely dry inside and free of corrosive substances before use.
3.3. Electrical Connection Precautions
When making electrical connections, adhere to all applicable national regulations for electrical safety.
DANGER:
- Before making electrical connections, cover the photovoltaic panels with opaque material or disconnect the DC side circuit breaker. Exposed to sunlight, photovoltaic arrays will generate dangerous voltages.
- When installing batteries, confirm the positive and negative terminals and turn off the battery.
- All installation operations must be performed by a qualified electrician.
- The installer must be trained and have fully read and understood the safety instructions in this manual.
3.4. Wiring Steps
Use appropriate cable sizes, not less than national electrical safety standards. Generally, cable sizes are selected based on a current density of ≤5A/mm², and connection cable length should be minimized to reduce losses.
3.4.1. System Connection Diagram

Image 5: General wiring diagram for the hybrid inverter system.
NOTICE:
- When connecting the inverter to batteries and PV input cables, pay attention to polarity; do not reverse connections.
- If connecting to a generator, start the generator first. Once stable, connect the inverter's AC input to the generator output, then start the inverter. After the inverter operates normally, connect user loads.
- It is recommended that the generator capacity be ≥3 times the rated capacity of the inverter.
3.4.2. Battery Input Connection
Connect the battery cables to the BATTERY terminals on the inverter. Ensure correct polarity (+ to + and - to -) to avoid damaging the product. Use a circuit breaker with appropriate breaking capacity between the battery and the inverter.
- Strip about 10mm of insulation from the positive and negative battery wires.
- Verify correct polarity before connecting.
- Connect the positive (+) cable to the BATTERY+ terminal and the negative (-) cable to the BATTERY- terminal.
- Ensure connections are secure and there are no short circuits between positive and negative terminals.
3.4.3. AC Input and Output Connection
CAUTION: Do not connect input and output terminals incorrectly.
Connect AC input and output cables as follows:
- Before connecting AC input and output, ensure the battery circuit breaker is off.
- Strip about 10mm of insulation from the 5 wires.
- Connect the AC cables to the INPUT and OUTPUT terminals according to polarity. Ensure the ground wire (PE) is connected first.
DANGER: Ensure the AC power supply is completely disconnected before connecting AC wires.
IMPORTANT: Ensure the live and neutral wire sequence for AC input and output cables is correct.
3.4.4. PV Input Connection
Connect solar panel input as follows:
- Strip about 10mm of insulation from the positive and negative PV wires.
- Verify correct polarity before connecting.
- Connect the positive (+) cable to the SOLAR+ terminal and the negative (-) cable to the SOLAR- terminal.
- Ensure connections are secure and there are no short circuits.
- The open-circuit voltage/short-circuit current of the PV array must be lower than the maximum PV input voltage/current of the inverter.
3.4.5. Assembly
Once all wiring is complete, secure the bottom cover back onto the inverter.
4. Operation
4.1. Display and Control Panel
The control panel consists of an LCD display, LED indicators, and function buttons.
4.1.1. LED Indicators
The four LEDs indicate the operating status and faults.
| Name | Description |
|---|---|
| AC (Green) | Solid: Inverter operates in grid mode output. Flashing: Inverter operates in battery priority mode, grid input detected normally. Off: Other states. |
| INV (Green) | Solid: Inverter operates in inverter mode output. Off: Other states. |
| CHG (Yellow) | Solid: Constant voltage charging, float charging, or fully charged. Flashing: Constant current charging. Off: Other states. |
| FAULT (Red) | Solid: Inverter protection. Flashing: Inverter alarm. Off: Inverter normal. |
4.1.2. Function Buttons
| Button | Function |
|---|---|
| DOWN | Decrease parameter value or navigate to previous page. |
| ESC | Exit setting mode without saving. |
| ENTER | Confirm selection or enter/save settings in setting mode. |
| UP | Increase parameter value or navigate to next page. |
4.2. LCD Screen Description
The LCD screen displays various operating parameters and settings. Use the UP/DOWN buttons to navigate through different display pages. The manual (pages 7-12 of the PDF) provides detailed descriptions of each display page (e.g., output voltage, frequency, battery voltage, PV input, etc.).
4.3. Function Settings
To enter the function setting mode, press and hold the ENTER button for more than 2 seconds. Use UP/DOWN to select the desired setting, then press ENTER to modify. Press ESC to exit without saving, or ENTER to save and exit.
The manual (pages 9-12 of the PDF) details various settings from A0 to A30, including:
- A0: Output Priority Setting: GRD (Grid Priority), PV (PV Priority), PBG (Battery Priority).
- A1: Bulk Charging Voltage Setting
- A2: Float Charging Voltage Setting
- A3: Battery Low Voltage Protection Setting
- A4: Battery Low Voltage Alarm Setting
- A5: Battery Low Voltage Recovery Setting
- A6: Grid to Inverter Battery Voltage Setting
- A7: Inverter to Grid Battery Voltage Setting
- A8: Frequency Setting: 50Hz/60Hz.
- A9: Output Voltage Setting: 220V/230V/240V.
- A10: Charging Priority Setting: SNU (Solar and Utility), OSO (Solar Only), CSO (Solar First).
- A11: Battery-less Mode Setting: bC (Battery Connected), bNC (Battery Not Connected).
- A12: Utility Charging Current Setting
- A13: Max Charging Current Setting
- A14: Utility Input Range Setting: UPS (165V-280V), APL (120V-280V).
- A15: Operating Mode Setting: GRD (Hybrid Mode), GRE (Grid-tied Feed-in Mode), DIS (Off-grid Mode).
- A16: Grid-tied Current Setting
- A17: Li-ion Battery BMS Communication Protocol Setting
- A18: BMS Communication Address Setting
- A19: Shutdown SOC Setting
- A20: Low Voltage Recovery SOC Setting
- A21: Inverter to Grid Battery SOC Setting
- A22: Grid to Inverter Battery SOC Setting
- A23: Charge Cut-off SOC Setting
- A24: Battery Low Voltage Restart Setting
- A25: Overload Restart Setting
- A26: Over-temperature Restart Setting
- A27: Inverter Host Communication Address Setting
- A28: Neutral Grounding Setting
- A29: Power Generation Clear Setting
- A30: One-key Restore Factory Settings
NOTICE: When setting battery parameters, ensure the logical relationships between voltage and SOC values are maintained to avoid errors (e.g., A1 > A2 > A6 > A5 > A7 > A4 > A3 for voltage, and A23 > A22 > A20 > A21 > A19 for SOC).
4.4. Output Priority and Operating Modes
The inverter supports various operating modes to suit different power requirements. The inverter will detect grid fluctuations for approximately 1 minute. If grid fluctuations do not exceed the AC input range during this period, the inverter will connect to the grid. This prevents frequent switching when the grid is unstable.
4.4.1. Grid-tied Mode (GRD/GRE)
In this mode, the inverter can feed excess solar power back into the grid.
- Utility Priority: Utility and PV simultaneously provide power to the load. Battery provides power only when utility is unavailable. PV is prioritized for battery charging, and any excess power is fed to the grid.
- PV Priority: Utility and PV simultaneously provide power to the load. Battery provides power only when utility is unavailable. PV is prioritized for load, then battery charging, and any excess power is fed to the grid.
4.4.2. Battery Priority Mode (PBG) - Off-grid Operation
PV will prioritize providing power to the load. If PV is insufficient or unavailable, the battery will supplement the load. When the battery discharge voltage reaches the set value, it will switch to utility power for the load.
4.4.3. Battery-Free Mode (bNC)
If no battery is connected, the inverter must be set to bNC (A11). In this mode, output priority cannot be set to Battery Priority. It will operate in Grid-tied or Hybrid mode.
- Grid-tied Mode: PV power is prioritized for the load. If PV is insufficient, utility supplements. If PV power exceeds the load, excess power is fed to the grid. If utility is unavailable, it operates on PV. If PV is insufficient, output is shut down.
- Hybrid Mode: Similar to grid-tied mode, with PV prioritized for load and utility supplementing.
- Off-grid Mode (Not Recommended): If PV power is insufficient, output will be unstable and may shut down.
5. Maintenance
The inverter requires minimal maintenance. Standard valve-regulated lead-acid batteries are low-maintenance and only need to be kept charged for optimal lifespan.
5.1. General Maintenance Tips
- If the inverter is not used for a long time, it is recommended to charge the battery every three months.
- Under normal conditions, battery life is 3-5 years. Replace batteries if they show signs of poor performance. Battery replacement must be performed by a professional.
- Batteries should not be replaced individually. When replacing multiple batteries, follow the battery manufacturer's instructions.
- Under normal conditions, charge and discharge the battery once every three months. Discharge until shutdown, then charge for at least 12 hours.
- In high-temperature areas, charge and discharge the battery once every two months. Standard charging time should not be less than 12 hours.
DANGER:
- Before replacing batteries, turn off the inverter and disconnect AC input and PV input lines.
- Do not wear metal objects like rings or watches.
- Use insulated tools. Do not place tools or other metal objects on the battery.
- Do not short-circuit or reverse battery polarity.
WARNING:
- Do not dispose of batteries in fire; they may explode.
- Do not open or damage batteries; released electrolyte is harmful to eyes and skin, and may be poisonous.
5.2. Dust Filter Disassembly and Assembly
To clean the dust filter:
- Remove the two screws securing the left and right dust filter covers.
- Remove the dust filter covers and dust filters.
- Clean the dust filters.
- Reassemble the dust filters and covers in reverse order.
- Secure the covers with the two screws.

Image 6: Dust filter components.
NOTICE: In environments with poor air quality, dust filters can easily become clogged. Regularly clean the dust filters to prevent affecting internal airflow, which could trigger over-temperature protection and impact the inverter's performance and lifespan.
6. Troubleshooting
When the inverter experiences a fault, the red FAULT LED will flash or remain solid, and a fault code will be displayed on the LCD. Refer to the table below for fault codes and solutions.
6.1. Fault Code Table
| Fault Code | Fault Information | Solution |
|---|---|---|
| 40 | EEPROM Read/Write Error | Contact supplier. |
| 41 | Main Controller Communication Error | Contact supplier. |
| 42 | Parameter Setting Anomaly | Check if parameters are set incorrectly or restore factory settings. |
| 43 | Reference Voltage Anomaly | Internal power supply unstable, restart unit. |
| 44 | BUS Soft Start Failure | Check if battery or utility voltage is too low. |
| 45 | Hardware Overcurrent | Check if output load is overloaded or non-linear. |
| 46 | Short Circuit Fault | Check if output has a short circuit, remove abnormal load. |
| 47 | Inverter Fault | If inductive load impact is too high, disconnect and reconnect. If not resolved, contact supplier. |
| 48 | Battery Overvoltage Alarm | Check if battery voltage is too high, battery cell count is correct. |
| 49 | Battery Overvoltage Protection | Check if battery voltage is too high, battery cell count is correct. |
| 50 | Battery Undervoltage Protection | Check if battery voltage is too low, battery cell count is correct. |
| 51 | Battery Undervoltage Alarm | Check if battery voltage is too low, battery cell count is correct. |
| 52 | BUS Overvoltage Fault | Check if battery or input voltage is too high. |
| 53 | BUS Undervoltage Fault | Check if battery or utility voltage is too low. |
| 54 | Overload Alarm | Check if output load is overloaded, reduce load appropriately. |
| 55 | Inverter Heatsink Over-temperature | Check if cooling fan is normal, ambient temperature is too high, or inverter vents are blocked. |
| 56 | DC/DC Heatsink Over-temperature | Check if cooling fan is normal, ambient temperature is too high, or inverter vents are blocked. |
| 57 | MPPT Heatsink Over-temperature | Check if cooling fan is normal, ambient temperature is too high, or inverter vents are blocked. |
| 58 | PV1 Overvoltage | Check if PV1 input voltage exceeds operating range. |
| 59 | PV2 Overvoltage | Check if PV2 input voltage exceeds operating range. |
| 60 | Utility Overvoltage | Check if input utility voltage is too high. |
| 61 | Frequency Anomaly | Check if utility frequency is normal. |
| 62 | Remote Shutdown | Confirm if a remote shutdown command was sent. |
| 63 | Li-ion Battery Communication Error | Check if inverter and Li-ion battery communication protocol matches, and if connection cable is correct. |
| 64 | Li-ion Battery Cell/Total Voltage Too High | Check if Li-ion battery cell voltage and total voltage are too high. |
| 65 | Li-ion Battery Cell/Total Voltage Too Low | Check if Li-ion battery cell voltage and total voltage are too low. |
| 66 | Li-ion Battery Discharge Overcurrent | Check if load is too large. |
| 67 | Li-ion Battery Charge Overcurrent | Appropriately reduce the maximum charging current set for the inverter. |
| 68 | Li-ion Battery Over-temperature | Check if Li-ion battery is overheating. Restart after cooling down. |
7. Specifications
The following table provides detailed technical specifications for the DATOUBOSS 12V 1800W Solar Hybrid Inverter (Model DT-1218M-A).
7.1. General Specifications
| Parameter | Value |
|---|---|
| Model Number | DT-1218M-A (DT-1218) |
| Rated Power | 1800W |
| Output Type | SINGLE |
| Output Voltage | 230V (220V/230V/240V settable) |
| Output Frequency | 50/60Hz |
| Output Waveform | Pure Sine Wave |
| Transfer Time | 10ms (typical) |
| Conversion Efficiency | ≥94% (Peak) |
| MPPT Tracking Efficiency | ≥99.9% |
| Display | LCD + LED |
| Noise Level | ≤55dB |
| Protection Class | IP20 |
| Cooling Method | Intelligent Fan Control |
| Operating Temperature | -10°C ~ 50°C |
| Storage Temperature | -15°C ~ 60°C |
| Humidity | 0% ~ 95% (non-condensing) |
| Weight | 4kg (Net), 5kg (Gross) |
| Dimensions (L*W*H) | 310x250x91mm |
| Certification | CE, FCC, RoHS |
| Is Smart Device | Yes |
| Supports | Battery-Free Mode |
7.2. PV Input Specifications
| Parameter | Value |
|---|---|
| Max PV Input Power | 2500W |
| Max PV Input Voltage (Voc) | 300VDC |
| MPPT Tracking Range | 30-240VDC |
| Max PV Charging Current | 100A |
| MPPT Tracking Channels | 1 |
7.3. Battery Specifications
| Parameter | Value |
|---|---|
| Battery Voltage | 12VDC |
| Battery Type | Valve-regulated lead-acid battery / Lithium battery (customizable) |
| Battery Voltage Range | 10.5-15VDC (default) |
| Max AC Charging Current | 65A |
NOTICE: Specifications are subject to change without prior notice.
8. User Tips and FAQ
8.1. Peak Load and Appliance Compatibility
The inverter has a rated power of 1800W. For inductive loads like refrigerators or motors, the starting power can be 2-3 times the rated power. When selecting the inverter capacity for such appliances, consider their starting power. For example, a refrigerator's compressor might draw significantly more power at startup than its running wattage. Ensure the inverter's peak power handling capacity is sufficient for these surge loads.
8.2. WiFi Module Compatibility
The inverter supports external communication via RS485-1 for WIFI monitoring. The manual refers to a "WIFI data collector" as an optional accessory. For specific compatible WiFi modules, refer to the "WIFI Communication Interface Appendix" (page 18 of the PDF manual) and the dedicated WIFI data collector user manual. The official website for monitoring is solar.siseli.com, and the app is "Solar of Things" available on Android and iOS app stores.
9. Warranty and Support
The product comes with a warranty. Please refer to the "Product Warranty Card" on page 18 of the comprehensive PDF manual for detailed warranty terms, duration, and conditions. Keep your warranty card and purchase receipt as proof of purchase.
9.1. Warranty Coverage
The warranty typically covers defects in materials and workmanship under normal use and maintenance. It does not cover damage due to incorrect installation, improper operation, unauthorized repairs, modifications, misuse, neglect, water damage, or natural disasters.
9.2. Technical Support
For any technical issues, troubleshooting assistance, or repair services, please contact your dealer or the DATOUBOSS customer service. Do not attempt to disassemble or repair the inverter yourself, as this will void the warranty and may cause further damage or injury.
NOTICE: A comprehensive user manual in PDF format is available for download. This document contains additional detailed information, including RS485 communication protocols and specific WIFI data collector instructions. You can find the PDF link here: User Manual (PDF).